Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Scand Cardiovasc J ; 51(3): 143-152, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28335644

RESUMO

OBJECTIVES: The objective of this pilot study was to describe the impact of paced heart rate on left ventricular (LV) mechanical dyssynchrony in synchronous compared to dyssynchronous pacing modes in patients with heart failure. METHODS: Echocardiography was performed in 14 cardiac resynchronization therapy (CRT) patients at paced heart rates of 70 and 90 bpm in synchronous- (CRT), and dyssynchronous (atrial pacing + wide QRS activation) pacing modes. LV dyssynchrony was quantified using the 12-segment standard deviation model (Ts-SD) derived from Tissue Doppler Imaging. In addition, cardiac cycle intervals were assessed using cardiac state diagrams and stroke volume (SV) and filling pressure were estimated. RESULTS: Ts-SD decreased significantly with CRT at 90 bpm (25 ± 12 ms) compared to 70 bpm (35 ± 15 ms, p = .01), but remained unchanged with atrial pacing at different paced heart rates (p = .96). The paced heart rate dependent reduction in Ts-SD was consistent when Ts-SD was indexed to average Ts and systolic time interval. Cardiac state diagram derived analysis of cardiac cycle intervals demonstrated a significant reduction of the pre-ejection interval and an increase in diastole with CRT compared to atrial pacing. SV was maintained at the higher paced heart rate with CRT pacing but decreased with atrial pacing. DISCUSSION: Due to the small sample size in this pilot study general and firm conclusions are difficult to render. However, the data suggest that pacing at higher heart rates acutely reduces remaining LV dyssynchrony during CRT, but not during atrial pacing with dyssynchronous ventricular activation. These results need confirmation in a larger patient cohort.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Frequência Cardíaca , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Pressão Ventricular
2.
Cardiovasc Ultrasound ; 14: 2, 2016 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-26729298

RESUMO

BACKGROUND: Contrast agents are used in resting echocardiography to opacify the left ventricular (LV) cavity and to improve LV endocardial border delineation in patients with suboptimal image quality. If a wider use of contrast-enhanced echocardiography would be adopted instead of the current selective approach, diagnoses such as myocardial ischemia and LV structural abnormalities could potentially be detected earlier. The aim was therefore to retrospectively investigate if contrast-enhanced echocardiography beyond the current recommendations for contrast agent usage affects assessment of wall motion abnormalities, ejection fraction (EF) and detection of LV structural abnormalities. A secondary aim was to evaluate the user dependency during image analysis. METHODS: Experienced readers (n = 4) evaluated wall motion score index (WMSI) and measured EF on greyscale and contrast-enhanced images from 192 patients without indications for contrast-enhanced echocardiography. Additionally, screening for LV structural abnormalities was performed. Repeated measurements were performed in 20 patients by the experienced as well as by inexperienced (n = 2) readers. RESULTS: Contrast analysis resulted in significantly higher WMSI compared to greyscale analysis (p < 0.003). Of the 83 patients, classified as healthy by greyscale analysis, 55% were re-classified with motion abnormalities by contrast analysis. No significant difference in EF classification (≥55%, 45-54%, 30-44%, < 30%) was observed. LV structural abnormalities, such as increased trabeculation (n = 21), apical aneurysm (n = 4), hypertrophy (n = 1) and thrombus (n = 1) were detected during contrast analysis. Intra- and interobserver variability for experienced readers as well as the variability between inexperienced and experienced readers decreased for WMSI and EF after contrast analysis. CONCLUSIONS: Contrast-enhanced echocardiography beyond current recommendations for contrast agent usage increased the number of detected wall motion and LV structural abnormalities. Moreover, contrast-enhanced echocardiography increased reproducibility for assessment of WMSI and EF.


Assuntos
Meios de Contraste , Ecocardiografia sob Estresse/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Ecocardiografia sob Estresse/normas , Europa (Continente) , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/normas , Interpretação de Imagem Assistida por Computador/normas , Masculino , Variações Dependentes do Observador , Guias de Prática Clínica como Assunto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos
3.
Eur J Anaesthesiol ; 33(9): 653-61, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27254026

RESUMO

BACKGROUND: Neoadjuvant chemoradiotherapy might improve oncological outcome compared with chemotherapy after surgery for oesophagus or gastrooesophageal junction cancer. However, radiotherapy may induce cardiovascular side-effects that could increase the risk of perioperative adverse effects and postoperative morbidity. OBJECTIVES: The aim of this study was to compare the perioperative haemodynamics in patients undergoing oesophagectomy following neoadjuvant chemotherapy or chemoradiotherapy for cancer. DESIGN: A prospective single-centre cohort study within a randomised multi-centre trial. SETTING: A Swedish University Hospital from January 2009 to March 2013. PATIENTS: A total of 31 patients (chemotherapy 17, chemoradiotherapy 14) included in a multi-centre trial randomising chemotherapy vs. chemoradiotherapy and operated at Karolinska University Hospital, Huddinge. INTERVENTIONS: Cisplatin and 5-fluorouracil, either with or without concurrent radiotherapy (40 Gy), were given prior to surgery. Cardiac function was assessed with LiDCOplus (LiDCO Ltd, London, United Kingdom), echocardiography, troponin T and N-terminal pro-B-type natriuretic peptide, before, during and after surgery. MAIN OUTCOME MEASURES: The primary outcome was the interaction effect of the neoadjuvant treatment on stroke volume index during the perioperative period. Secondary outcomes were the interaction effects of oxygen delivery index, cardiac index, echocardiography and biochemical markers. RESULTS: The groups were matched regarding comorbidities, but patients in the chemoradiotherapy group were older (66 vs. 60 years P = 0.03). Haemodynamic values changed in a similar way in both groups during the study period. The chemoradiotherapy group had a lower cardiac index before surgery (2.9 vs. 3.4 l min m, P = 0.03). On the third postoperative day, both groups displayed a hyperdynamic state compared with baseline, with no increase in troponin T, and a similar increase in N-terminal pro-B-type natriuretic peptide. CONCLUSION: Neoadjuvant chemoradiotherapy for oesophageal or gastrooesophageal junction cancer seems to induce only a marginal negative effect on cardiac function compared with neoadjuvant chemotherapy. This difference did not remain when patients' haemodynamics were challenged by surgery. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01362127.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Quimiorradioterapia/métodos , Neoplasias Esofágicas/terapia , Hemodinâmica/fisiologia , Terapia Neoadjuvante/métodos , Assistência Perioperatória/métodos , Idoso , Estudos de Coortes , Neoplasias Esofágicas/sangue , Neoplasias Esofágicas/fisiopatologia , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Estudos Prospectivos , Resultado do Tratamento
4.
J Physiol ; 593(8): 1901-12, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-25630680

RESUMO

KEY POINTS: A hallmark of mitral stenosis (MS) is the markedly altered left ventricular (LV) loading. As most of the methods used to determine LV performance in MS patients are influenced by loading conditions, previous studies have shown conflicting results. The present study calculated LV elastance, which is a robust method to quantify LV function. We demonstrate that LV loading in MS patients is elevated but normalizes after valve repair and might be a result of reflex pathways. Additionally, we show that the LV in MS is less compliant than normal due to a combination of right ventricular loading and the valvular disease itself. Immediately after valve dilatation the increase in blood inflow into the LV results in even greater LV stiffness. Our findings enrich our understanding of heart function in MS patients and provide a simple reproducible way of assessing LV performance in MS. ABSTRACT: Left ventricular (LV) function in rheumatic mitral stenosis (MS) remains an issue of controversy, due to load dependency of previously employed assessment methods. We investigated LV performance in MS employing relatively load-independent indices robust to the altered loading state. We studied 106 subjects (32 ± 8 years, 72% female) with severe MS (0.8 ± 0.2 cm(2) ) and 40 age-matched controls. MS subjects underwent simultaneous bi-ventricular catheterization and transthoracic echocardiography (TTE) before and immediately after percutaneous transvenous mitral commisurotomy (PTMC). Sphygmomanometric brachial artery pressures and TTE recordings were simultaneously acquired in controls. Single-beat LV elastance (Ees ) was employed for LV contractility measurements. Effective arterial elastance (Ea ) and LV diastolic stiffness were measured. MS patients demonstrated significantly elevated afterload (Ea : 3.0 ± 1.3 vs. 1.5 ± 0.3 mmHg ml(-1) ; P < 0.001) and LV contractility (Ees : 4.1 ± 1.6 vs. 2.4 ± 0.5 mmHg ml(-1) ; P < 0.001) as compared to controls, with higher Ea in subjects with smaller mitral valve area (≤ 0.8 cm(2) ) and pronounced subvalvular fusion. Stroke volume (49 ± 16 to 57 ± 17 ml; P < 0.001) and indexed LV end-diastolic volume (LVEDVindex : 57 ± 16 to 64 ± 16 ml m(-2) ; P < 0.001) increased following PTMC while Ees and Ea returned to more normal levels. Elevated LV stiffness was demonstrated at baseline and increased further following PTMC. Our findings provide evidence of elevated LV contractility, increased arterial load and increased diastolic stiffness in severe MS. Following PTMC, both LV contractility and afterload tend to normalize.


Assuntos
Ventrículos do Coração/fisiopatologia , Hemodinâmica/fisiologia , Estenose da Valva Mitral/fisiopatologia , Função Ventricular Esquerda/fisiologia , Adulto , Ecocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Estenose da Valva Mitral/diagnóstico por imagem , Volume Sistólico/fisiologia , Adulto Jovem
5.
Am Heart J ; 167(6): 876-83, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24890538

RESUMO

BACKGROUND: Pulmonary capillary wedge pressure (PCWP) is routinely used as an indirect measure of the left atrial pressure (LAP), although the accuracy of this estimate, especially under pathological hemodynamic conditions, remains controversial. OBJECTIVES: The aim of this prospective study was to investigate the reliability of PCWP for the evaluation of LAP under different hemodynamic conditions. METHODS: Simultaneous left and right heart catheterization data of 117 patients with pure mitral stenosis, obtained before and immediately after percutaneous mitral comissurotomy, were analyzed. RESULTS: A strong correlation and agreement between PCWP and LAP measurements was demonstrated (correlation coefficient = 0.97, mean bias ± CI, 0.3 ± -3.7 to 4.2 mm Hg). Comparison of measurements performed within a 5-minute interval and those performed simultaneously revealed that simultaneous pressure acquisition yielded better agreement between the 2 methods (bias ± CI, 1.82 ± 1.98 mm Hg). In contrast to previous observations, the discrepancy between the 2 measures did not increase with elevated PCWP. Multiple regression analysis failed to identify hemodynamic confounders of the discrepancy between the 2 pressures. The ability of PCWP to distinguish between normal and elevated LAP (cutoff set at 12 and 15 mm Hg, respectively), as tested by receiver operating characteristics analysis, demonstrated a remarkably high diagnostic accuracy (area under the curve: 0.989 and 0.996, respectively). CONCLUSIONS: Although the described limits of agreement may not allow the interchangeability of PCWP and LAP, especially at lower pressure ranges, our data support the clinical use of PCWP as a robust and accurate estimate of LAP.


Assuntos
Pressão Atrial/fisiologia , Cateterismo Cardíaco , Estenose da Valva Mitral/diagnóstico , Pressão Propulsora Pulmonar/fisiologia , Adulto , Estudos de Coortes , Ecocardiografia , Feminino , Átrios do Coração , Hemodinâmica , Humanos , Hipertensão Pulmonar/diagnóstico , Masculino , Anuloplastia da Valva Mitral , Estenose da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/cirurgia , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
6.
Cardiovasc Ultrasound ; 11: 35, 2013 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-24119333

RESUMO

BACKGROUND: Echocardiography is a well-established tool for risk stratification in patients with acute coronary syndrome (ACS). ACS has significant impact on LV dyssynchrony, and detrimental effects on systolic function and long term outcome. The aims of this study were to determine whether LV dyssynchrony carries any predictive information in an unselected ACS population and to evaluate if it has any incremental value to the information given from conventional echocardiographic measurements. METHODS: The study included 227 consecutive ACS patients. Primary endpoint was the composite of death, new MI, or rehospitalisation due to heart failure. Dyssynchrony was measured as intersegmental variation of time to peak strain, the post systolic index (PSI) and myocardial performance index (MPI) with the standard deviation and difference between lowest and highest value (delta) expressing the amount of dyssynchrony. Septal-lateral delay was also tested. All dyssynchrony parameters were compared with Ejection fraction (EF). RESULTS: The median follow up time was 53 months. 85 patients reached the combined endpoint. Patients with and without a subsequent combined endpoint differed significantly regarding calculated SD: s and delta-value for PSI, time to peak 2D-strain and MPI but not regarding septal-lateral delay. In ROC-analysis none of the dyssynchrony parameters had larger AUC than EF. When adjusting for traditional risk factors none of the dyssynchrony parameters remained associated with outcome, whereas EF still did. CONCLUSION: LV dyssynchrony seem to have significant prognostic information in patient with acute coronary syndrome but in comparison to conventional parameters such as EF there is no incremental value of this information.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Ecocardiografia/estatística & dados numéricos , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Comorbidade , Feminino , Humanos , Incidência , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Taxa de Sobrevida , Suécia/epidemiologia
7.
Cardiovasc Ultrasound ; 11: 9, 2013 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-23547949

RESUMO

BACKGROUND: Traditional echocardiographic methods like left ventricular ejection fraction(EF) and wall motion scoring (WMS) and new methods like speckle tracking (ST) based 2D strain carry important prognostic information in acute coronary syndrome (ACS) patients. Parameters from tissue Doppler imaging (TDI), with its high time resolution, may further increase the prognostic value. Peak systolic velocity (PSV) of the basal segments of the left ventricle from TDI is a robust and user independent parameter. The aim was to investigate the prognostic value of PSV compared to EF, WMS, 2D strain and E/e'. METHODS: Echocardiographic images were collected and post processed in 227 ACS patients. Additional clinical data was prospectively gathered and patients were followed for 3-5 years regarding the combined endpoint of death or re-admission due to ACS or heart failure. RESULTS: The combined endpoint occurred in 85 (37%) patients. Those with an event had lower median PSV than those without (4,4 cm/s) vs. (5,3 cm/s), (p<0.001). In a ROC analysis, the AUC was larger for PSV (0.75) than for EF (0.68), WMS (0.63), 2D strain (0.67) and E/e'(0.70). The combined endpoint increased with decreasing PSV. When adjusting for differences in baseline characteristics in a COX-regression model, PSV remained independently associated with outcome where the others did not. PSV was also less sensitive to image quality with fewer values missing or unacceptable for analysis. CONCLUSION: Peak systolic velocity (PSV) is a robust measurement that seems to have a strong and independent association with outcome compared to traditional echocardiographic measurements in ACS patients.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia Doppler em Cores/métodos , Contração Miocárdica/fisiologia , Disfunção Ventricular Esquerda/etiologia , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Curva ROC , Sístole , Fatores de Tempo , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
8.
Eur J Appl Physiol ; 112(12): 4069-79, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22476861

RESUMO

Exercise can lead to release of biomarkers such as cardiac troponin T (cTnT) and N-terminal pro-brain natriuretic peptide (NT-proBNP), a poorly understood phenomenon proposed to especially occur with high-intensity exercise in less trained subjects. We hypothesised that haemodynamic perturbations during exercise are larger in athletes with cTnT release, and studied athletes with detectable cTnT levels after an endurance event (HIGH; n = 16; 46 ± 9 years) against matched controls whose levels were undetectable (LOW; n = 11; 44 ± 7 years). Echocardiography was performed at rest and at peak supine bicycle exercise stress. Left ventricular (LV) end-systolic elastance (E (LV) a load-independent measure of LV contractility), effective arterial elastance (E (A) a lumped index of arterial load) and end-systolic meridional wall stress were calculated from cardiac dimensions and brachial blood pressure. Efficiency of cardiac work was judged from the ventriculo-arterial coupling ratio (E (A)/E (LV): optimal range 0.5-1.0). While subgroups had similar values at rest, we found ventriculo-arterial mismatch during exercise in HIGH subjects [0.47 (0.39-0.58) vs. LOW: 0.73 (0.62-0.83); p < 0.01] due to unopposed increase in E (LV) (p < 0.05). In LOW subjects, a greater increase occurred in E (A) during exercise (+81 ± 67 % vs. HIGH: +39 ± 32 %; p = 0.02) which contributed to a maintained coupling ratio. Subjects with higher baseline NT-proBNP had greater systolic wall stress during exercise (R (2) = 0.39; p < 0.01) despite no correlation at rest (p = ns). In conclusion, athletes with exercise-induced biomarker release exhibit ventriculo-arterial mismatch during exercise, suggesting non-optimal cardiac work may contribute to this phenomenon.


Assuntos
Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Resistência Física/fisiologia , Corrida/fisiologia , Troponina/sangue , Função Ventricular Esquerda , Adulto , Atletas , Biomarcadores/sangue , Pressão Sanguínea , Débito Cardíaco , Estudos de Casos e Controles , Ecocardiografia , Teste de Esforço , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade
9.
J Cardiovasc Transl Res ; 15(4): 692-707, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34882286

RESUMO

Ventricular-vascular interaction is central in the adaptation to cardiovascular disease. However, cardiomyopathy patients are predominantly monitored using cardiac biomarkers. The aim of this study is therefore to explore aortic function in dilated cardiomyopathy (DCM). Fourteen idiopathic DCM patients and 16 controls underwent cardiac magnetic resonance imaging, with aortic relative pressure derived using physics-based image processing and a virtual cohort utilized to assess the impact of cardiovascular properties on aortic behaviour. Subjects with reduced left ventricular systolic function had significantly reduced aortic relative pressure, increased aortic stiffness, and significantly delayed time-to-pressure peak duration. From the virtual cohort, aortic stiffness and aortic volumetric size were identified as key determinants of aortic relative pressure. As such, this study shows how advanced flow imaging and aortic hemodynamic evaluation could provide novel insights into the manifestation of DCM, with signs of both altered aortic structure and function derived in DCM using our proposed imaging protocol.


Assuntos
Cardiomiopatia Dilatada , Humanos , Hemodinâmica , Aorta/diagnóstico por imagem , Ventrículos do Coração , Imageamento por Ressonância Magnética/métodos , Função Ventricular Esquerda
10.
Am J Physiol Heart Circ Physiol ; 301(6): H2433-41, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21926340

RESUMO

Elderly female hypertensives with arterial stiffening constitute a majority of patients with heart failure with preserved ejection fraction (HFpEF), a condition characterized by inability to increase cardiac stroke volume (SV) with physical exercise. As SV is determined by the interaction between the left ventricle (LV) and its load, we wished to study the role of arterial hemodynamics for exertional SV reserve in patients at high risk of HFpEF. Twenty-one elderly (67 ± 9 yr) female hypertensive patients were studied at rest and during supine bicycle stress using echocardiography including pulsed-wave Doppler to record flow in the LV outflow tract and arterial tonometry for central arterial pressure waveforms. Arterial compliance was estimated based on an exponential relationship between pressure and volume. The ratio of aortic pressure-to-flow in early systole was used to derive characteristic impedance, which was subsequently subtracted from total resistance (mean arterial pressure/cardiac output) to yield systemic vascular resistance (SVR). It was found that patients with depressed SV reserve (NoRes; reserve <15%; n = 10) showed decreased arterial compliance during exercise, while patients with SV reserve ≥15% (Res; n = 11) showed increased compliance. Exercise produced parallel increases in LV end-diastolic volume and arterial volume in Res patients while NoRes patients exhibited a lesser decrease in SVR and a drop in effective arterial volume. Poor SV reserve in elderly female hypertensives is due to simultaneous failure of LV preload and arterial vasodilatory reserves. Abnormal arterial function contributes to a high risk of HFpEF in these patients.


Assuntos
Artérias/fisiopatologia , Exercício Físico , Insuficiência Cardíaca/etiologia , Hipertensão/complicações , Volume Sistólico , Vasodilatação , Função Ventricular Esquerda , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Pressão Sanguínea , Complacência (Medida de Distensibilidade) , Diástole , Ecocardiografia Doppler de Pulso , Teste de Esforço , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Hipertensão/diagnóstico por imagem , Hipertensão/fisiopatologia , Modelos Lineares , Manometria , Modelos Cardiovasculares , Dinâmica não Linear , Medição de Risco , Fatores de Risco , Fatores Sexuais , Suécia , Resistência Vascular
11.
Cardiovasc Ultrasound ; 8: 45, 2010 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-20920373

RESUMO

BACKGROUND: Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching artifact. The study aimed to investigate whether SB full volume 3DE acquisition reduces inter- and intraobserver variability in assessment of LV volumes and EF in comparison to four-beat (4B) ECG-gated full volume 3DE recording in patients with AF. METHODS: A total of 78 patients were included in this study. Fifty-five with sinus rhythm (group A) and 23 having AF (group B). 4B and SB 3DE was performed in all patients. LV volumes and EF was determined by these two modalities and inter- and intraobserver variability was analyzed. RESULTS: SB modality showed significantly lower inter- and intraobserver variability in group B in comparison to 4B when measuring LV volumes and EF, except for end-systolic volume (ESV) in intraobserver analysis. There were significant differences when calculating the LV volumes (p < 0.001) and EF (p < 0.05) with SB in comparison to 4B in group B. CONCLUSION: Single-beat three-dimensional full volume acquisition seems to be superior to four-beat ECG-gated acquisition in measuring left ventricular volumes and ejection fraction in patients having atrial fibrillation. The variability is significantly lower both for ejection fraction and left ventricular volumes.


Assuntos
Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca/métodos , Ecocardiografia Tridimensional/métodos , Aumento da Imagem/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico
12.
Echocardiography ; 27(9): 1078-85, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20546012

RESUMO

AIMS: The aim of the study was to investigate whether left ventricular stroke volume (LVSV) assessment using direct measurement of left ventricular outflow tract area (LVOT(A)) is superior to conventional methods for SV calculation. METHODS AND RESULTS: Thirty patients were included in the study (39 ± 12 years). LVSV was assessed by multiplying LVOT velocity time integral (VTI) by LVOT(A) provided by direct planimetrical measurements from real time three-dimensional echocardiography (RT3DE) in biplane mode (SV2). These measurements were compared to conventional methods using either the LVOT diameter for LVOT(A) multiplied with VTI (SV1) or biplane Simpson (SV3). Direct SV measurements by RT3DE were used as gold standard (SV(ref)). There was an excellent correlation and agreement between SV determined by SV2 and 3DE (r = 0.98, mean difference 0.5 ± 3.3 mL). However, the concordance of the traditional methods (SV1 and SV3) with 3DE was weaker (r = 0.38, mean difference -2.0 ± 17.6 mL, r = 0.84, mean difference -7.6 ± 8.7 mL, respectively). Furthermore, cardiac output (CO) measurements performed by the different modalities were not concordant with wide limits of agreement, except by SV2 the mean difference of CO by SV1 was -0.12 ± 1.05 L/min, 0.03 ± 0.20 L/min by SV2, and -0.45 ± 0.52 L/min by SV3. CONCLUSIONS: SV and CO calculations using direct measurement of LVOT area is a feasible, accurate and reproducible method and correlates extremely well with 3DE volume measurements. SV and CO calculation by LVOT(A) is therefore an appealing method for LVSV assessment in clinical routine.


Assuntos
Anatomia Transversal/métodos , Ventrículos do Coração/diagnóstico por imagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Volume Sistólico , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Adulto , Algoritmos , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia
13.
Infect Ecol Epidemiol ; 10(1): 1789036, 2020 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-32939231

RESUMO

The COVID-19 pandemic is growing and spread in the Swedish elderly care system during April 2020. The increasing number of employees on sick-leave due to COVID-19 created severe logistic problems. Some elderly care homes therefore started to screen their personnel to secure the safety of the elderly and to avoid unnecessary quarantine of potentially immune employees. Secondary data from a screening with a COVID-19 rapid test for detection of SARS-CoV-2-specific IgM and IgG of 1,005 employees in 22 elderly care homes in Stockholm, Sweden, were analyzed. Seropositive employees were found in 21 out of the 22 care homes. In total, 23% (231/1,005) of the employees tested positive for antibodies against SARS-CoV-2, and 14.3% (144/1,005) were found positive for IgM (either alone or combined with IgG), indicating recent or present infection. Of those that tested seropositive, 46.5% did not report any clinical symptoms, indicating pre- or asymptomatic infections. Reported symptoms with the highest correlation with seropositivity were fever and loss of smell and taste. These results suggest that antibody testing of employees in elderly care homes is valuable for surveillance of disease development and a crucial screening tool in the effort to decrease the death toll in this pandemic.

15.
Sci Rep ; 10(1): 403, 2020 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-31942025

RESUMO

Fatal cerebrovascular events are often caused by rupture of atherosclerotic plaques. However, rupture-prone plaques are often distinguished by their internal composition rather than degree of luminal narrowing, and conventional imaging techniques might thus fail to detect such culprit lesions. In this feasibility study, we investigate the potential of ultrasound shear wave elastography (SWE) to detect vulnerable carotid plaques, evaluating group velocity and frequency-dependent phase velocities as novel biomarkers for plaque vulnerability. In total, 27 carotid plaques from 20 patients were scanned by ultrasound SWE and magnetic resonance imaging (MRI). SWE output was quantified as group velocity and frequency-dependent phase velocities, respectively, with results correlated to intraplaque constituents identified by MRI. Overall, vulnerable lesions graded as American Heart Association (AHA) type VI showed significantly higher group and phase velocity compared to any other AHA type. A selection of correlations with intraplaque components could also be identified with group and phase velocity (lipid-rich necrotic core content, fibrous cap structure, intraplaque hemorrhage), complementing the clinical lesion classification. In conclusion, we demonstrate the ability to detect vulnerable carotid plaques using combined SWE, with group velocity and frequency-dependent phase velocity providing potentially complementary information on plaque characteristics. With such, the method represents a promising non-invasive approach for refined atherosclerotic risk prediction.


Assuntos
Artérias Carótidas/patologia , Doenças das Artérias Carótidas/patologia , Técnicas de Imagem por Elasticidade/métodos , Imageamento por Ressonância Magnética/métodos , Placa Aterosclerótica/patologia , Ultrassonografia/métodos , Idoso , Idoso de 80 Anos ou mais , Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/diagnóstico por imagem , Análise Espaço-Temporal
16.
Eur J Echocardiogr ; 10(3): 406-13, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-18988658

RESUMO

AIMS: Colour tissue Doppler (TD) has been reported to underestimate the longitudinal myocardial motion velocities measured with spectral TD. This study evaluates the effect of temporal smoothing and offline gain settings on the results of velocity measurements with these two methods and the difference between them. METHODS AND RESULTS: In 57 patients, 2D data and left ventricular velocity profiles were acquired using spectral and colour TD for a subsequent offline analysis. Longitudinal myocardial velocities were measured at unsaturated, 50%-saturated and fully saturated gain, and before and after temporal smoothing using 30, 50, and 70 ms filters, respectively. Gain level and filter width altered significantly the measured velocities. Peak systolic and early diastolic velocities were significantly higher (P < 0.001) and E/E' ratio was significantly lower (P < 0.001) with spectral TD than with colour TD, although there was a good correlation between the results of both TD modalities. The differences between the methods increased at increasing filter width and gain level. CONCLUSION: Despite good correlation of the results, spectral TD produces significantly higher myocardial velocity values and lower E/E' ratio than colour TD modality. Increasing gain and temporal smoothing alter significantly the results of velocity measurements and accentuate the difference between the two TD methods.


Assuntos
Ecocardiografia , Interpretação de Imagem Assistida por Computador/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Análise de Variância , Diástole , Ecocardiografia/métodos , Ecocardiografia/normas , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Doppler em Cores/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Volume Sistólico , Sístole , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
17.
Eur J Echocardiogr ; 10(3): 389-94, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-18945726

RESUMO

AIMS: The objective was to evaluate the function of ultrasound transducers in use in routine clinical practice and thereby estimating the incidence of defective transducers. METHODS AND RESULTS: The study comprised a one-time test of 676 transducers from 7 manufacturers which were in daily use in clinical departments at 32 hospitals. They were tested with the Sonora FirstCall Test System; 39.8% exhibited a transducer error. Delamination was detected in 26.5% and break in the cable was detected in 8.4% of the tested transducers. Errors originating from the piezoelectrical elements were unusual. Delamination and short circuit occurred without significant differences between transducers from all tested manufacturers, but the errors break in the cable, weak and dead element showed a statistically significant higher frequency in transducers from certain manufacturers. CONCLUSION: The high error frequency and the risk for incorrect medical decisions when using a defective transducer indicate an urgent need for increased testing of the transducers in clinical departments.


Assuntos
Análise de Falha de Equipamento , Transdutores/normas , Ultrassonografia Doppler em Cores/instrumentação , Criança , Permeabilidade do Canal Arterial/diagnóstico por imagem , Análise de Falha de Equipamento/métodos , Feminino , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Sensibilidade e Especificidade
18.
Heart Vessels ; 24(5): 357-65, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19784819

RESUMO

Wave intensity analysis is a concept providing information about the interaction of the heart and the vascular system. Originally, the technique was invasive. Since then new noninvasive methods have been developed. A recently developed ultrasound technique to estimate tissue motion and deformation is speckle-tracking echocardiography. Speckle tracking-based techniques allow for accurate measurement of movement and deformation variables in the arterial wall in both the radial and the longitudinal direction. The aim of this study was to test if speckle tracking-derived deformation data could be used as input for wave intensity calculations. The new concept was to approximate changes of flow and pressure by deformation changes of the arterial wall in longitudinal and radial directions. Flow changes (dU/dt) were approximated by strain rate (sr, 1/s) of the arterial wall in the longitudinal direction, whereas pressure changes (dP/dt) were approximated by sign reversed strain rate (1/s) in the arterial wall in the radial direction. To validate the new concept, a comparison between the newly developed Wave Intensity Wall Analysis (WIWA) algorithm and a commonly used and validated wave intensity system (SSD-5500, Aloka, Tokyo, Japan) was performed. The studied population consisted of ten healthy individuals (three women, seven men) and ten patients (all men) with coronary artery disease. The present validation study indicates that the mechanical properties of the arterial wall, as measured by a speckle tracking-based technique are a possible input for wave intensity calculations. The study demonstrates good visual agreement between the two systems and the time interval between the two positive peaks (W1-W2) measured by the Aloka system and the WIWA system correlated for the total group (r = 0.595, P < 0.001). The correlation for the diseased subgroup was r = 0.797, P < 0.001 and for the healthy subgroup no significant correlation was found (P > 0.05). The results of the study indicate that the mechanical properties of the arterial wall could be used as input for wave intensity calculations. The WIWA concept is a promising new method that potentially provides several advantages over earlier wave intensity methods, but it still has limitations and needs further refinement and larger studies to find the optimal clinical use.


Assuntos
Doenças das Artérias Carótidas/diagnóstico por imagem , Artéria Carótida Primitiva/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Ecocardiografia/métodos , Hemodinâmica , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Pressão Sanguínea , Doenças das Artérias Carótidas/fisiopatologia , Artéria Carótida Primitiva/fisiopatologia , Estudos de Casos e Controles , Estenose Coronária/fisiopatologia , Elasticidade , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fluxo Pulsátil , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes
19.
Cardiovasc Ultrasound ; 7: 12, 2009 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-19292894

RESUMO

BACKGROUND: Echocardiographic measurements of left ventricular (LV) myocardial displacement may produce different results depending on the choice of employed modality and subjective adjustments during data acquisition and analysis. METHODS: In this study, left ventricular longitudinal systolic displacement was quantified in 57 patients (31 women and 26 men, 50 +/- 16 years) using colour (colour TD) and spectral tissue Doppler (spectral TD) before and after temporal filtering (30 to 70 milliseconds in 20-millisecond steps) and changed offline gain saturation (0%, 50% and 100%), respectively. The results were compared with those obtained with anatomic M-mode. RESULTS: Whereas only minor differences occurred between the results of colour TD and anatomic M-mode measurements, spectral TD significantly overestimated the results obtained with both these methods. However, the limits of agreement between the results produced by all three studied methods were not clinically acceptable in any of the cases. The spectral TD displacement values increased along with increasing offline gain saturation whereas the effect of temporal filtering on colour Doppler measurements was insignificant. CONCLUSION: Measurements of LV myocardial longitudinal displacement employing spectral TD, colour TD or anatomic M-mode produce different results, thus discouraging interchangeable use of these modalities. Whereas the results of spectral TD measurements can be significantly altered by changing offline gain setting, the effect of temporal filtering on colour TD measurements is insignificant, a fact that increases clinical practicality of the latter method.


Assuntos
Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Doppler em Cores/normas , Sístole , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia
20.
Cardiovasc Ultrasound ; 7: 22, 2009 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-19473478

RESUMO

BACKGROUND: Cardiac time intervals have been described as a measure of cardiac performance, where prolongation, shortening and delay of the different time intervals have been evaluated as markers of cardiac dysfunction. A relatively recently developed method with improved ability to measure cardiac events is Tissue Doppler Imaging (TDI), allowing accurate measurement of myocardial movements. METHODS: We propose the state diagram of the heart as a new visualization tool for cardiac time intervals, presenting comparative, normalized data of systolic and diastolic performance, providing a more complete overview of cardiac function. This study aimed to test the feasibility of the state diagram method by presenting examples demonstrating its potential use in the clinical setting and by performing a clinical study, which included a comparison of the state diagram method with established echocardiography methods (E/E' ratio, LVEF and WMSI). The population in the clinical study consisted of seven patients with non ST-elevation myocardial infarction (NSTEMI) and seven control subjects, individually matched according to age and gender. The state diagram of the heart was generated from TDI curves from seven positions in the myocardium, visualizing the inter- and intraventricular function of the heart by displaying the cardiac phases. RESULTS: The clinical examples demonstrated that the state diagram allows for an intuitive visualization of pathological patterns as ischemia and dyssynchrony. Further, significant differences in percentage duration between the control group and the NSTEMI group were found in eight of the totally twenty phases (10 phases for each ventricle), e.g. in the transition phases (Pre-Ejection and Post-Ejection). These phases were significantly longer (> 2.18%) for the NSTEMI group than for the control group (p < 0.05). No significant differences between the groups were found for the established echocardiography methods. CONCLUSION: The test results clearly indicate that the state diagram has potential to be an efficient tool for visualization of cardiac dysfunction and for detection of NSTEMI.


Assuntos
Gráficos por Computador , Ecocardiografia/métodos , Técnicas de Imagem por Elasticidade/métodos , Cardiopatias/diagnóstico por imagem , Cardiopatias/fisiopatologia , Coração/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa