Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38994680

RESUMO

INTRODUCTION: Scar substrate in nonischemic cardiomyopathy (NICM) patients is often difficult to identify. Advances in cardiac imaging, especially using late iodine-enhanced computed tomography (LIE-CT), allow better characterization of scars giving rise to ventricular tachycardia (VT). Currently, there are limited data on clinical correlates of CT-derived scar substrates in NICM. We sought assess the relationship between scar location on LIE-CT and outcomes after radiofrequency catheter ablation (RFCA) in NICM patients with VT. METHODS: From 2020 to 2022, consecutive patients with NICM undergoing VT RFCA with integration of cardiac CT scar modeling (inHeart, Pessac, France) were included at two US tertiary care centers. The CT protocol included both arterial-enhanced imaging for anatomical modeling and LIE-CT for scar assessment. The distribution of substrate on CT was analyzed in relation to patient outcomes, with primary endpoints being VT recurrence and the need for repeat ablation procedure. RESULTS: Sixty patients were included (age 64 ± 12 years, 90% men). Over a median follow-up of 120 days (interquartile range [IQR]: 41-365), repeat ablation procedures were required in 32 (53%). VT recurrence occurred in 46 (77%), with a median time to recurrence of 40 days (IQR: 8-65). CT-derived total scar volume positively correlated with intrinsic QRS duration (r = .34, p = 0.008). Septal scar was found on CT in 34 (57%), and lateral scar in 40 (7%). On univariate logistic regression, septal scar was associated with increased odds of repeat ablation (odds ratio [OR]: 2.9 [1.0-8.4]; p = 0.046), while lateral scar was not (OR: 0.9 [0.3-2.7]; p = 0.855). Septal scar better predicted VT recurrence when compared to lateral scar, but neither were statistically significant (septal scar OR: 3.0 [0.9-10.7]; p = 0.078; lateral scar OR: 1.7 [0.5-5.9]; p = 0.391). CONCLUSION: In this tertiary care referral population, patients with NICM undergoing VT catheter ablation with septal LIE-CT have nearly threefold increased risk of need for repeat ablation.

2.
J Cardiovasc Electrophysiol ; 33(4): 698-712, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35048448

RESUMO

BACKGROUND: Ablation Index (AI) is a multiparametric quality marker to assess the durability of radiofrequency (RF) lesions. The comparative effectiveness and safety of AI versus time-based energy dosing for ablation of ventricular arrhythmias are unknown. OBJECTIVE: We compared AI and time-based RF dosing strategies in the left ventricles (LVs) of freshly harvested porcine hearts. METHODS: Ablation was performed in vitro with an open-irrigated ablation catheter (Thermocool ST/SF), 40 W, contact force 10-15 g. Tissue samples were stained in triphenyltetrazolium chloride for the measurement of lesion dimensions. RESULTS: A total of 560 lesions were performed (AI-group: [n = 360]; time-group: [n = 200]). Using normal saline (NS) (n = 280), growth in lesion depth slowed after 30 s and AI > 550 in comparison to width, volume, and magnitude of impedance drops which continued to increase with longer RF duration. Risk of steam pop (SP) was higher for RF > 30 s (RF < 30 s:1 SP [2.5%] vs. RF > 30 s: 15 SP [25%]; p = .002) or AI targets >550 (AI: 350-550: 2 SP [2%] vs. AI 600-750: 15 SP [19%]; p = .001). Using half-normal saline (HNS) (n = 280), lesion dimension and impedance drops were larger and growth in lesion depth slowed earlier (AI: 500). Risk of SPs was higher above AI 550 (AI: 350-550: 7 [7%] SPs vs. AI 600-750: 28 [35%] SPs; p < .00001). While codependent variables, correlation between AI and time was modest-to-strong but decreased with longer RF duration. CONCLUSION: In this ex vivo study, AI was a better predictor of lesion dimensions than ablation time and magnitude of impedance drop in the LV using NS and HNS irrigation. AI targets above 550 led to a higher risk of SPs. Future trials are required to verify these findings.


Assuntos
Ablação por Cateter , Solução Salina , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Desenho de Equipamento , Coração , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Suínos , Irrigação Terapêutica/efeitos adversos , Irrigação Terapêutica/métodos
3.
J Cardiovasc Electrophysiol ; 32(6): 1748-1753, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33855779

RESUMO

BACKGROUND: Cardioneuroablation (CNA) is an emerging technique being used to treat patients with cardioinhibitory vasovagal syncope (VVS). We describe a case of CNA in targeting atrial ganglionated plexi (GP) based upon anatomical landmarks and fractionated electrogram (EGM) localization in a patient with cardioinhibitory syncope. CASE PRESENTATION: A 20-year-old healthy female presented with malignant VVS and symptomatic sinus pauses, with the longest detected at 10 s. She underwent acutely successful CNA with demonstration of vagal response (VR) noted after ablation of left sided GP, and tachycardia noted with right sided GP ablation. All GP sites were defined by anatomical landmarks and EGM analysis. By using the fractionation mapping software of Ensite Precision mapping system with high density mapping, fragmented EGMs were successfully detected in each GP site. One month after vagal denervation, there were no recurrent syncopal episodes or sinus pauses. Longer term follow-up with implantable loop recorder is planned. CONCLUSION: We performed CNA in a patient with VVS by utilizing a novel approach of combined use of high density mapping and fractionation mapping software. With this approach, we were able to detect fractionation in all GP sites and demonstrate acute VR. This workflow may allow for a new, standardized technique suitable for widespread use.


Assuntos
Ablação por Cateter , Síncope Vasovagal , Adulto , Feminino , Humanos , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/cirurgia , Nervo Vago/cirurgia , Adulto Jovem
4.
J Cardiovasc Electrophysiol ; 32(4): 1077-1084, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33650717

RESUMO

INTRODUCTION: Catheter ablation (CA) of frequent premature ventricular contractions (PVC) is increasingly performed in older patients as the population ages. The aim of this study was to assess the impact of age on procedural characteristics, safety and efficacy on PVC ablations. METHODS: Consecutive patients with symptomatic PVCs undergoing CA between 2015 and 2020 were evaluated. Acute ablation success was defined as the elimination of PVCs at the end of the procedure. Sustained success was defined as an elimination of symptoms, and ≥80% reduction of PVC burden determined by Holter-electrocardiogram during long-term follow. Patients were sub-grouped based on age (<65 vs. ≥65 years). RESULTS: A total of 114 patients were enrolled (median age 64 years, 71% males) and followed up for a median duration of 228 days. Baseline and procedural data were similar in both age groups. A left-sided origin of PVCs was more frequently observed in the elderly patient group compared to younger patients (83% vs. 67%; p = .04). The median procedure time was significantly shorter in elderly patients (160 vs. 193 min; p = .02). The rates of both acute (86% vs. 92%; p = .32) and sustained success (70% vs. 71%; p = .90) were similar between groups. Complications rates (3.7%) did not differ between the two groups. CONCLUSION: In a large series of patients with a variety of underlying arrhythmia substrates, similar rates of acute procedural success, complications, and ventricular arrhythmia-free-survival were observed after CA of PVCs. Older age alone should not be a reason to withhold CA of PVCs.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Idoso , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
5.
J Cardiovasc Electrophysiol ; 31(2): 417-422, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31868258

RESUMO

INTRODUCTION: By providing real-time monitoring of catheter-tissue interface and for complications, intracardiac echocardiography (ICE) during catheter ablation for ventricular tachycardia (VT) may improve outcomes. To test this hypothesis, we compared 12-month readmission rates (all-cause, cardiovascular [CV]-related, and VT-related), repeat ablation, and complications among patients with VT with structural heart disease undergoing ablation with versus without ICE. METHODS AND RESULTS: Using the 2008-2017 IBM MarketScan Commercial and Medicare Supplemental databases, patients with a history of implantable cardioverter defibrillator/cardiac resynchronization therapy (ICD/CRT-D) who underwent VT ablation with and without ICE use were identified. Propensity matching was performed and regression analysis was used to compare outcomes. After matching, 1324 patients were identified (ICE: 662; non-ICE: 662). The rate of 12-month VT-related readmission (18.13% vs 22.51%; P < .05) and repeat VT ablation (14.35% vs 19.34%; P = .02) postindex discharge were lower among patients in the ICE group compared with the non-ICE group, with a 24% lower risk of 12-month VT-related readmission (odds ratio [OR], 0.76; 95% confidence interval [CI], 0.58-0.99) and a 30% lower risk of repeat ablation (OR, 0.70; 95% CI, 0.52-0.93) vs non-ICE group. The 12-month all-cause (44.56% vs 43.20%; P = .62) and CV-related readmissions (35.20% vs 32.93%; P = 0.38) and complication rates were not significantly different between the two groups. CONCLUSIONS: VT ablation using ICE was associated with a lower likelihood of 12-month VT-related readmission and repeat ablation compared with non-ICE patients.


Assuntos
Ablação por Cateter , Ecocardiografia , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Adolescente , Adulto , Idoso , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Bases de Dados Factuais , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
6.
J Cardiovasc Electrophysiol ; 27(1): 102-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26359632

RESUMO

INTRODUCTION: Next-generation catheters have been developed to reduce irrigation volume and preserve power delivery. A novel design uses a flexible tip (FlexAbility™ catheter) that directs flow to the contact surface. Because of recent safety issues with new catheters, we undertook a study in a canine heart with 3 irrigated catheters to compare efficacy and safety. METHODS: Endocardial ablation was performed by 2 independent operators in 12 anesthetized canines with the FlexAbility (St. Jude Medical), ThermoCool™ (Biosense Webster), and ThermoCool™ SF (Biosense Webster) catheters. Endocardial RF lesions were delivered with each catheter in all 4 chambers of each animal for 52 ± 16 seconds. Each chamber was randomized to receive ablation from one catheter with recording of safety events. Cardiac pathology was performed with triphenyl tetrazolium chloride stain. RESULTS: Average lesion dimensions were not significantly different between the 3 catheters. FlexAbility™ demonstrated a lower risk of steam pops relative to ThermoCool SF (P-value = 0.013) despite equal mean power and radiofrequency time. High-temperature generator shutdowns were observed with FlexAbility™ but not with either ThermoCool catheter. High-temperature shutdowns were associated with larger average impedance drops (28.5 ohms vs. 19 ohms) without compromising lesion size. CONCLUSIONS: The FlexAbility™ tip is safe and effective with no significant difference in lesion sizes compared to both standard ThermoCool and ThermoCool SF. FlexAbility™ has a significantly lower risk of steam pops compared to ThermoCool SF in a beating heart as defined predominantly by an abrupt rise of impedance.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Endocárdio/cirurgia , Irrigação Terapêutica/instrumentação , Animais , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Cães , Impedância Elétrica , Endocárdio/patologia , Desenho de Equipamento , Temperatura Alta , Teste de Materiais , Modelos Animais , Irrigação Terapêutica/efeitos adversos
7.
Artigo em Inglês | MEDLINE | ID: mdl-38499825

RESUMO

BACKGROUND: Cardioneuroablation has been emerging as a potential treatment alternative in appropriately selected patients with cardioinhibitory vasovagal syncope (VVS) and functional AV block (AVB). However the majority of available evidence has been derived from retrospective cohort studies performed by experienced operators. METHODS: The Cardioneuroablation for the Management of Patients with Recurrent Vasovagal Syncope and Symptomatic Bradyarrhythmias (CNA-FWRD) Registry is a multicenter prospective registry with cross-over design evaluating acute and long-term outcomes of VVS and AVB patients treated by conservative therapy and CNA. RESULTS: The study is a prospective observational registry with cross-over design for analysis of outcomes between a control group (i.e., behavioral and medical therapy only) and intervention group (Cardioneuroablation). Primary and secondary outcomes will only be assessed after enrollment in the registry. The follow-up period will be 3 years after enrollment. CONCLUSIONS: There remains a lack of prospective multicentered data for long-term outcomes comparing conservative therapy to radiofrequency CNA procedures particularly for key outcomes including recurrence of syncope, AV block, durable impact of disruption of the autonomic nervous system, and long-term complications after CNA. The CNA-FWRD registry has the potential to help fill this information gap.

8.
Curr Opin Cardiol ; 28(3): 344-53, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23549237

RESUMO

PURPOSE OF REVIEW: Drug-refractory ventricular tachycardia in the setting of structural heart disease results in frequent implantable cardioverter defibrillator therapies and an increased risk of heart failure. Management requires catheter ablation procedures for effective suppression of the arrhythmia. RECENT FINDINGS: Imaging and electroanatomic mapping technologies provide new insights into the myocardial structural abnormalities responsible for ventricular tachycardia. Integration of imaging data with three-dimensional mapping systems coupled with improved targeting of abnormal electrical signals may improve the ablation outcomes. New ablation tools show promise for the effective ablation of previously unreachable myocardial ventricular tachycardia circuits. SUMMARY: Catheter ablation procedures have evolved over the last 2 decades. Improved technology may contribute to more widespread utilization of catheter ablation in the future.


Assuntos
Ablação por Cateter/métodos , Taquicardia Ventricular/terapia , Técnicas de Imagem Cardíaca , Desfibriladores Implantáveis , Eletrocardiografia , Humanos , Resultado do Tratamento
9.
J Innov Card Rhythm Manag ; 14(3): 5389-5392, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36998421

RESUMO

Coronary venous mapping and ablation can be an effective strategy in targeting ventricular arrhythmias that arise from intramural or epicardial sites of origin. We discuss the case of a patient with ischemic cardiomyopathy referred to our center for index ventricular tachycardia ablation after receiving multiple shocks from his implantable cardioverter-defibrillator who underwent coronary venous mapping and ablation as an adjunct to endocardial ventricular tachycardia ablation.

10.
J Interv Card Electrophysiol ; 66(1): 145-151, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35581463

RESUMO

BACKGROUND: Ventricular tachycardia (VT) ablation of mid- or epicardial substrate is difficult and requires a creative approach in patients with a history of coronary bypass that precludes percutaneous epicardial catheter manipulation. The coronary venous system (CVS) provides limited access to the epicardial surface of the heart. The objective of this study is to assess the feasibility, safety, and efficacy of epicardial mapping and ablation of VT substrates from the CVS in patients with history of coronary bypass. METHODS: Patients undergoing VT ablation at our institution were retrospectively reviewed. Those who had basal to mid ventricular substrate based on computed tomography imaging and history of coronary bypass were included. Endocardial and CVS mapping and ablation was performed in standard fashion using 3D electroanatomic mapping. The primary endpoint was defined as VT circuit elimination, termination, non-inducibility, or perturbation of the circuit. RESULTS: Of 192 consecutive VT ablations from 2017 to 2020, 35 (18%) had a history of coronary bypass and basal to the mid-ventricular substrate by imaging. There were no significant characteristic differences between the endocardial only (n = 19) vs endocardial + CVS (n = 16) groups. In 14 (88%) of patients undergoing CVS mapping, the VT circuit was identified to be within access from the epicardial surface. Ablation was attempted in 8 (57%) of these patients, and the primary endpoint was reached in 88% of those undergoing CVS ablation. There were no complications related to CVS ablation. CONCLUSION: Mapping and ablation of mid- or epicardial VT circuits from the CVS branches are feasible and safe and may be helpful in the treatment of VT in patients who are otherwise not candidates for percutaneous epicardial ablation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Mapeamento Epicárdico/métodos , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Ventrículos do Coração/cirurgia , Endocárdio/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento , Pericárdio/diagnóstico por imagem , Pericárdio/cirurgia
11.
Expert Rev Med Devices ; 20(10): 797-803, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37584235

RESUMO

INTRODUCTION: Advanced cardiac imaging is an important component in pre-procedural planning for ventricular tachycardia (VT) ablations. inHEART's proprietary software, inHEART Models, and its academic version, Multimodality Platform for Specific Imaging in Cardiology (MUSIC), provide detailed characterization of anatomical structures and scars. AREAS COVERED: This review highlights the current overview of the market and offers insight into inHEART Models and MUSIC and its application during VT ablations with supporting case examples. An overview of the clinical profile and regulatory status of inHEART Models, and other competing technologies, such as Automatic Detection of Arrhythmia Substrate (ADAS) 3D software and Catheter Precision's View into Ventricular Onset (VIVO), are also discussed. EXPERT OPINION: inHEART and MUSIC utilization has increased over the last few years and continues to establish its presence as an important aspect of VT ablations. Its unique proprietary software sets itself apart from others in the field. The introduction of dual source-photon counting detector computed tomography (PCD-CT) is expected to make significant advancements in the field and take imaging to a new level. inHEART's continued research in cardiac imaging and digital technology is expected to increase as is its global presence in the electrophysiology (EP) community.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Coração , Ventrículos do Coração , Arritmias Cardíacas/cirurgia , Tomografia Computadorizada por Raios X , Ablação por Cateter/métodos
12.
JACC Clin Electrophysiol ; 9(11): 2342-2346, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37737777

RESUMO

The authors describe 3 patients presenting with cardiac sarcoidosis (CS) flare and ventricular tachycardia (VT) storm following infection with severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2), the causative agent of COVID-19. COVID-19-related cardiac manifestations can vary and include arrythmias, myocarditis, and exacerbation of underlying cardiovascular disease. The exact mechanism of myocardial involvement is not clear but may include abnormal host immune response and direct myocardial injury, thereby predisposing to enhanced arrhythmic risk. Arrhythmias account for 20% of COVID-19-related complications with ventricular arrythmias occurring in 5.9% of cases. Further studies are needed to better understand mechanisms underlying the intersection between COVID-19 infection and inflammatory cardiomyopathies.


Assuntos
COVID-19 , Cardiomiopatias , Miocardite , Sarcoidose , Taquicardia Ventricular , Humanos , COVID-19/complicações , Cardiomiopatias/complicações , SARS-CoV-2 , Sarcoidose/complicações , Arritmias Cardíacas/complicações
13.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1684-1693, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37354175

RESUMO

BACKGROUND: The PAINESD (Pulmonary disease, Age, Ischemic cardiomyopathy, NYHA functional class, Ejection fraction, Storm, Diabetes mellitus) risk score has been validated as a predictor of periprocedural acute hemodynamic decompensation (AHD) in patients undergoing ventricular tachycardia (VT) ablation. Whether the addition of total scar volume (TSV) determined by preprocedure computed tomography imaging provides additional risk stratification has not been previously investigated. OBJECTIVES: The purpose of this study was to evaluate the impact of TSV on the risk of AHD and its adjunctive benefit to the PAINESD score newly modified as Pulmonary disease, Age, Ischemic cardiomyopathy, NYHA class, Ejection fraction, Storm, Scar volume, Diabetes mellitus (PAINES2D) based on the addition of scar volumes. METHODS: This was a retrospective analysis of all index VT ablations at a quaternary care center from 2017 to 2022. Associations between TSV and AHD were evaluated among patients with structural heart disease. RESULTS: Among 61 patients with TSV data, 13 (21%) had periprocedural AHD. TSV and PAINESD were independently associated with AHD risk. Both TSV and PAINESD were associated with AHD (P = 0.016 vs P = 0.053, respectively). The highest TSV tertile (≥37.30 mL) showed significant association with AHD (P = 0.018; OR: 4.80) compared to the other tertiles. The PAINESD and PAINES2D scores had significant impact on AHD (P = 0.046 and P = 0.010, respectively). The PAINES2D score had a greater impact on AHD compared to PAINESD (area under the curve: 0.73; P = 0.011; 95% CI: 0.56-0.91 and area under the curve: 0.67; P = 0.058; 95% CI: 0.49-0.85, respectively). CONCLUSIONS: Addition of TSV to a modified PAINESD score, PAINES2D, enhances risk prediction of AHD. Further prospective study is needed to assess benefit in various cardiomyopathy populations undergoing VT ablation.


Assuntos
Ablação por Cateter , Hemodinâmica , Taquicardia Ventricular , Humanos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cicatriz/complicações , Cicatriz/diagnóstico por imagem , Hemodinâmica/fisiologia , Estudos Retrospectivos , Medição de Risco , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Masculino , Feminino , Idoso , Tomografia Computadorizada por Raios X
14.
Heart Rhythm O2 ; 4(7): 440-447, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520016

RESUMO

Background: High-power, short-duration (HPSD) radiofrequency ablation (RFA) reduces procedure time; however, safety and efficacy thresholds vary with catheter design. Objective: The study sought to determine optimal HPSD ablation conditions with a novel flexible-tipped, contact force-sensing RFA catheter. Methods: RFA lesions were created in thigh muscle (16 swine) over a range of conditions (51-82 W, 2-40 g, 8-40 mL/min irrigation). An intracardiac study was performed (12 swine) to characterize steam pop thresholds. Lesions were created in a second intracardiac study (14 swine, n = 290 pulmonary vein isolation [PVI] lesions) with combinations of radiofrequency power, duration, and contact force. PVI was tested, animals were sacrificed, and lesions were measured. Results: The likelihood of coagulation formation in the thigh model was <20% when power was ≤79 W, when contact force was ≤40 g, when duration was ≤11 seconds, and when irrigation rates were 8 to 40 mL/min. The impact of contact force on lesion safety and efficacy was more pronounced using HPSD (60 W/8 seconds) compared with conventional ablation (30 W/45 seconds) (P = .038). During PVI, focal atrial lesions ranged in width from 4.2 to 12.5 mm and were transmural 80.8% of the time. PVI was achieved in 13 of 14 veins. Logistic regression identified that the optimal parameters for radiofrequency application were 60 to 70 W with a duration <8 seconds and <15 g contact force. Conclusions: Optimal HPSD lesions with this this flexible-tipped, force-sensing RFA catheter were created at 60 to 70 W for <8 seconds with <15 g contact force. Chronic studies are ongoing to assess radiofrequency parameter refinements and long-term lesion durability using these conditions.

15.
Heart Rhythm ; 19(5): 828-836, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35032670

RESUMO

BACKGROUND: Conventional contact-based electroanatomic mapping is poorly suited for rapid or dynamic ventricular arrhythmias. Whole-chamber charge density (CD) mapping could efficiently characterize complex ventricular tachyarrhythmias and yield insights into their underlying mechanisms. OBJECTIVE: The purpose of this study was to evaluate the feasibility and accuracy of noncontact whole-chamber left ventricular (LV) CD mapping and to characterize CD activation patterns during sinus rhythm, ventricular pacing, and ventricular fibrillation (VF). METHODS: Ischemic scar as defined by CD amplitude thresholds was compared to late gadolinium enhancement criteria on magnetic resonance imaging using an iterative closest point algorithm. Electrograms recorded at sites of tissue contact were compared to the nearest noncontact CD-derived electrograms to calculate signal morphology cross-correlations and time differences. Regions of consistently slow conduction were examined relative to areas of scar and to localized irregular activation (LIA) during VF. RESULTS: Areas under receiver operating characteristic curves (AUCs) of CD-defined dense and total LV scar were 0.92 ± 0.03 and 0.87 ± 0.06, with accuracies of 0.86 ± 0.03 and 0.80 ± 0.05, respectively. Morphology cross-correlation between 8677 contact and corresponding noncontact electrograms was 0.93 ± 0.10, with a mean time difference of 2.5 ± 5.6 ms. Areas of consistently slow conduction tended to occur at scar borders and exhibited spatial agreement with LIA during VF (AUC 0.90 ± 0.02). CONCLUSION: Noncontact LV CD mapping can accurately delineate ischemic scar. CD-derived ventricular electrograms correlate strongly with conventional contact-based electrograms. Regions with consistently slow conduction are often at scar borders and tend to harbor LIA during VF.


Assuntos
Ventrículos do Coração , Taquicardia Ventricular , Animais , Arritmias Cardíacas/patologia , Cicatriz , Meios de Contraste , Gadolínio , Ovinos
17.
J Innov Card Rhythm Manag ; 12(4): 4473-4476, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33936863

RESUMO

Cardioneuroablation (CNA) is an emerging technique used to treat patients with vasovagal syncope (VVS). We herein describe a case of CNA targeting the atrial ganglionated plexi (GPs) based upon anatomical landmarks and fractionated electrogram (EGM) localization in a 20-year-old healthy female who presented to our center with malignant VVS and symptomatic sinus pauses, the longest of which measured 10 seconds. She underwent acutely successful CNA with a demonstration of vagal response noted following ablation of the left-sided GPs, and tachycardia was noted with right-sided GP ablation. All GP sites were defined by anatomical landmarks and EGM analysis. By using the fractionation mapping software of the EnSite Precision™ cardiac mapping system (Abbott, Chicago, IL, USA) with high-density mapping, fragmented EGMs were successfully detected in each GP site. One month after vagal denervation, no recurrent syncopal episodes or sinus pauses had been recorded. Longer-term follow-up with an implantable loop recorder is planned. Broadly, we performed CNA in a patient with VVS by combining high-density mapping and fractionation mapping software in a novel approach, which allowed us to detect fractionation in all GP sites and demonstrate an acute vagal response. This workflow may facilitate the introduction of a standardized technique suitable for widespread use.

18.
Micromachines (Basel) ; 12(2)2021 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-33673330

RESUMO

Catheter-based ablation techniques have a well-established role in atrial fibrillation (AF) management. The prevalence and impact of AF is increasing globally, thus mandating an emphasis on improving ablation techniques through innovation. One key area of ongoing evolution in this field is the use of laser energy to perform pulmonary vein isolation during AF catheter ablation. While laser use is not as widespread as other ablation techniques, such as radiofrequency ablation and cryoballoon ablation, advancements in product design and procedural protocols have demonstrated laser balloon ablation to be equally safe and effective compared to these other modalities. Additionally, strategies to improve procedural efficiency and decrease radiation exposure through low fluoroscopy protocols make this technology an increasingly promising and exciting option.

19.
Circulation ; 120(7): 553-9, 2009 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-19652097

RESUMO

BACKGROUND: Cardiac repolarization, the process by which cardiomyocytes return to their resting potential after each beat, is a highly regulated process that is critical for heart rhythm stability. Perturbations of cardiac repolarization increase the risk for life-threatening arrhythmias and sudden cardiac death. Although genetic studies of familial long-QT syndromes have uncovered several key genes in cardiac repolarization, the major heritable contribution to this trait remains unexplained. Identification of additional genes may lead to a better understanding of the underlying biology, aid in identification of patients at risk for sudden death, and potentially enable new treatments for susceptible individuals. METHODS AND RESULTS: We extended and refined a zebrafish model of cardiac repolarization by using fluorescent reporters of transmembrane potential. We then conducted a drug-sensitized genetic screen in zebrafish, identifying 15 genes, including GINS3, that affect cardiac repolarization. Testing these genes for human relevance in 2 concurrently completed genome-wide association studies revealed that the human GINS3 ortholog is located in the 16q21 locus, which is strongly associated with QT interval. CONCLUSIONS: This sensitized zebrafish screen identified 15 novel myocardial repolarization genes. Among these genes is GINS3, the human ortholog of which is a major locus in 2 concurrent human genome-wide association studies of QT interval. These results reveal a novel network of genes that regulate cardiac repolarization.


Assuntos
Perfilação da Expressão Gênica , Genes Reguladores/fisiologia , Sistema de Condução Cardíaco/fisiologia , Coração/fisiologia , Potenciais da Membrana/fisiologia , Animais , Morte Súbita Cardíaca/epidemiologia , Humanos , Síndrome do QT Longo/genética , Modelos Animais , Miócitos Cardíacos/citologia , Miócitos Cardíacos/fisiologia , Fenótipo , Fatores de Risco , Peixe-Zebra
20.
J Comp Eff Res ; 9(5): 375-385, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32134325

RESUMO

Aim: To compare outcomes among patients with implantable cardioverter defibrillator/cardiac resynchronization therapy-defibrillator undergoing outpatient ventricular tachycardia (VT) catheter ablation using intracardiac echocardiography (ICE) versus no ICE. Patients & methods: Patients were classified into ICE (n = 1143)/non-ICE (n = 1677) groups based on ICE procedure codes. Patients in each group were propensity matched on study covariates. Survival analyses were used to assess outcomes. To examine residual confounding, falsification outcomes were evaluated. Results: ICE patients had a 24% lower risk of all-cause readmissions, 24% lower risk of cardiovascular-related and 20% lower risk of VT-related readmissions compared with non-ICE patients. Falsification analyses for ICE use association were nonsignificant. Conclusion: Patients with implantable cardioverter defibrillator/cardiac resynchronization therapy-defibrillator undergoing VT ablation with ICE use had significantly lower likelihood of VT-related readmission.


Assuntos
Ablação por Cateter/métodos , Desfibriladores Implantáveis , Ecocardiografia/métodos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa