Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiat Oncol ; 13(1): 192, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30285812

RESUMO

BACKGROUND: The SpaceOAR hydrogel is employed to limit rectal radiation dose during prostate radiotherapy. We identified a novel parameter - the product of angle θ and hydrogel volume - to quantify hydrogel placement. This parameter predicted rectum dosimetry and acute rectal toxicity in prostate cancer patients treated with stereotactic body radiotherapy to 36.25 Gy in 5 fractions. METHODS: Twenty men with low- and intermediate-risk prostate cancer underwent hydrogel placement from 2015 to 2017. Hydrogel symmetry was assessed on the CT simulation scan in 3 axial slices (midgland, 1 cm above midgland, 1 cm below midgland). Two novel parameters quantifying hydrogel placement - hydrogel volume and angle θ formed by the prostate, hydrogel, and rectum - were measured, and the normalized product of θ and hydrogel volume calculated. These were then correlated with perirectal distance, rectum maximum 1-3 cc point doses (rDmax 1-3 cc), and rectum volumes receiving 80-95% of the prescription dose (rV80-95%). Acute rectal toxicity was recorded per RTOG criteria. RESULTS: In 50% of patients, hydrogel placement was symmetric bilaterally to within 1 cm of midline in all three CT simulation scan axial slices. Lateral hydrogel asymmetry < 2 cm in any one axial slice did not affect rectum dosimetry, but absence of hydrogel in the inferior axial slice resulted in a mean increase of 171 cGy in the rDmax 1 cc (p < 0.005). The perirectal distance measured at prostate midgland, midline (mean 9.1 ± 4.3 mm) correlated strongly with rV95 (R2 0.6, p < 0.001). The mean hydrogel volume and θ were 10.3 ± 4.5 cc and 70 ± 49°, respectively. Perirectal distance, rV95 and rDmax 1 cc correlated with hydrogel angle θ (p < 0.01), and yet more strongly with the novel metric θ*hydrogel volume (p < 0.001). With a median follow up of 14 months, no rectal toxicity >grade 2 was observed. Low grade rectal toxicity was observed in a third of men and resolved within 1 month of SBRT. Men who had these symptoms had higher rDmax 1 cc and smaller θ*hydrogel volume measurements. CONCLUSIONS: Optimal hydrogel placement occurs at prostate midgland, midline. The novel parameter θ*hydrogel volume describes a large proportion of rectum dosimetric benefit derived from hydrogel placement, and can be used to assess the learning curve phenomenon for hydrogel placement.


Assuntos
Hidrogéis/química , Modelos Estatísticos , Órgãos em Risco/efeitos da radiação , Neoplasias da Próstata/cirurgia , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador/métodos , Reto/efeitos da radiação , Idoso , Idoso de 80 Anos ou mais , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa