Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Appl Opt ; 63(14): 3900-3909, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38856353

RESUMO

Steel cables used to raise sluices require a layer of corrosion-resistant grease, which must be periodically replaced. It is time-consuming and laborious, and conventional manual cleaning, mechanical cleaning, and chemical cleaning methods have many drawbacks. In this paper, a nanosecond pulsed fiber laser is used to clean hardened surface grease from such cables. An experimental system was designed to study the effects of parameters such as the laser power, scanning speed, cleaning frequency, and defocusing amount. Macroscopic and microstructural observations were conducted on the surfaces of steel cables before and after cleaning using cameras, optical microscopy, scanning electron microscopy, and energy dispersive spectrometry. With the optimal parameters, laser cleaning can effectively remove hardened grease from steel cable surfaces without damaging the galvanized layer and the steel wire matrix. Ablation, gasification, and evaporation are the main mechanisms by which grease and dirt are removed. This study lays a foundation for optimizing the laser cleaning of steel sluice cables at work sites.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38960866

RESUMO

OBJECTIVES: In order to assist junior doctors in better diagnosing apical periodontitis (AP), an artificial intelligence AP grading system was developed based on deep learning (DL) and its reliability and accuracy were evaluated. METHODS: 120 cone-beam computed tomography (CBCT) images were selected to construct a classification dataset with four categories, which were divided by CBCT periapical index (CBCTPAI), including normal periapical tissue, CBCTPAI 1-2, CBCTPAI 3-5 and young permanent teeth. Three classic algorithms (ResNet50/101/152) as well as one self-invented algorithm (PAINet) were compared with each other. PAINet were also compared with two recent Transformer-based models and three attention models. Their performance was evaluated by accuracy, precision, recall, balanced F score (F1-score) and the area under the macro-average receiver operating curve (AUC). Reliability was evaluated by Cohen's kappa ​​to compare the consistency of model predicted labels with expert opinions. RESULTS: PAINet performed best among the four algorithms. The accuracy, precision, recall, F1-score and AUC on the test set were 0.9333, 0.9415, 0.9333, 0.9336 and 0.9972, respectively. Cohen's kappa was 0.911, which represented almost perfect consistency. CONCLUSIONS: PAINet can accurately distinguish between normal periapical tissues, CBCTPAI 1-2, CBCTPAI 3-5 and young permanent teeth. Its results were highly consistent with expert opinions. It can help junior doctors diagnose and score AP, reducing the burden. It can also be promoted in areas where experts are lacking to provide professional diagnostic opinions.

3.
Part Fibre Toxicol ; 19(1): 31, 2022 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-35477523

RESUMO

BACKGROUND: Carbon dot has been widely used in biomedical field as a kind of nanomaterial with low toxicity and high biocompatibility. CDs has demonstrated its unique advantages in assisted drug delivery, target diagnosis and targeted therapy with its small size and spontaneous fluorescence. However, the potential biosafety of CDs cannot be evaluated. Therefore, we focused on the study of liver, the target organ involved in CDs metabolism, to evaluate the risk of CDs in vitro. METHODS AND RESULTS: Liver macrophage KUP5 cells and normal liver cells AML12 cells were incubated in CDs at the same concentration for 24 h to compare the different effects under the same exposure conditions. The study found that both liver cell models showed ATP metabolism disorder, membrane damage, autophagosome formation and lysosome damage, but the difference was that, KUP5 cells exhibited more serious damage than AML12 cells, suggesting that immunogenic cell type is particularly sensitive to CDs. The underlying mechanism of CDs-induced death of the two hepatocyte types were also assessed. In KUP5 cells, death was caused by inhibition of autophagic flux caused by autophagosome accumulation, this process that was reversed when autophagosome accumulation was prevented by 3-MA. AML12 cells had no such response, suggesting that the accumulation of autophagosomes caused by CDs may be specific to macrophages. CONCLUSION: Activation of the TFEB-lysosome pathway is important in regulating autophagy and apoptosis. The dual regulation of ERK and mTOR phosphorylation upstream of TFEB influences the death outcome of AML12 cells. These findings provide a new understanding of how CDs impact different liver cells and contribute to a more complete toxicological safety evaluation of CDs.


Assuntos
Pontos Quânticos , Carbono/toxicidade , Morte Celular , Hepatócitos , Células de Kupffer , Lisossomos , Pontos Quânticos/toxicidade
4.
Int J Mol Sci ; 23(23)2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36499333

RESUMO

Due to the rapid development of the miniaturization and portability of electronic devices, the demand for polymer composites with high thermal conductivity and mechanical flexibility has significantly increased. A carbon nanotube (CNT)-graphene (Gr)/polydimethylsiloxane (PDMS) composite with excellent thermal conductivity and mechanical flexibility is prepared by ultrasonic-assisted forced infiltration (UAFI). When the mass ratio of CNT and Gr reaches 3:1, the thermal conductivity of the CNT-Gr(3:1)/PDMS composite is 4.641 W/(m·K), which is 1619% higher than that of a pure PDMS matrix. In addition, the CNT-Gr(3:1)/PDMS composite also has excellent mechanical properties. The tensile strength and elongation at break of CNT-Gr(3:1)/PDMS composites are 3.29 MPa and 29.40%, respectively. The CNT-Gr/PDMS composite also shows good performance in terms of electromagnetic shielding and thermal stability. The PDMS composites have great potential in the thermal management of electronic devices.


Assuntos
Grafite , Nanotubos de Carbono , Dimetilpolisiloxanos , Condutividade Térmica
5.
BMC Oral Health ; 22(1): 504, 2022 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-36384556

RESUMO

BACKGROUND: Guided endodontics is a successful technique that has been gradually applied to endodontic therapy in recent years without being affected by the operator's experience. However, the guided bur produces excessive heat during continuous rotation and friction with root canal walls, it is not clear whether the degree of temperature increase may lead to the periodontal ligament and alveolar bone damage. METHODS: A total of 58 teeth were used, of which 40 teeth were not grouped, all used to evaluate the accuracy. 40 single-rooted premolars were scanned using CBCT and an intra-oral scanner, and 3D-printed guided plates were made with the pre-designed access. A custom-made guided bur was used to prepare the access cavities. The postoperative CBCT data and pre-designed pathways were matched to evaluate the deviation between the planned and virtual paths. The other 18 teeth were randomly divided into three groups (ET20 and ProTaper F3 as the control group, guided endodontics as the test group), with 6 teeth in each group. The temperature changes on the root surfaces were inspected with a thermocouple thermometer. RESULTS: The average deviation on the tip and the base of the bur was 0.30 mm and 0.28 mm (mesial/distal), and 0.28 mm and 0.25 mm (buccal/lingual). The average angle deviation was 3.62°. The mean root surface temperature rise of the guided endodontics group was the lowest (5.07 °C) (P < 0.05). CONCLUSIONS: The access cavity preparation performed with guided endodontics has feasible accuracy and low-temperature rise on the root surfaces. Due to the limitations of the study, whether it has high reliability and safety in clinical applications needs to be further studied in vivo.


Assuntos
Endodontia , Humanos , Temperatura , Reprodutibilidade dos Testes , Preparo da Cavidade Dentária/métodos , Tratamento do Canal Radicular
6.
BMC Oral Health ; 20(1): 43, 2020 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-32028960

RESUMO

BACKGROUND: Better understanding of the danger zone anatomy in mesial roots (MRs) of mandibular first molars (MFMs) may serve to decrease the risk of mishaps. This study aimed to measure the minimal distal dentine thicknesses of danger zone in MRs of MFMs in a native Chinese population using cone-beam computed tomography (CBCT). METHODS: CBCT images of 1792 MFMs from 898 Chinese patients were analyzed. The minimal distal dentine thicknesses of the mesiobuccal (MB) and mesiolingual (ML) canals below the furcation 1, 2, 3, 4, 5 mm were measured. The association between the minimal distal dentine thicknesses and the root lengths, patient's age and gender, side were assessed. RESULTS: The minimal distal dentine thicknesses of MB and ML canals are located 3 ∼ 4 mm below the furcation for both men and women. There are no differences between MB and ML canals, while the minimal distal dentine thicknesses of MB and ML canals were higher in men than women (P < 0.05), except at 1 and 3 mm of ML canals (P > 0.05). The minimal distal dentine thicknesses of MB and ML canals increased with age in both men and women at each location (P < 0.05). The minimum distal dentine thickness at every location were significantly different between long teeth and short teeth both in men and women (P < 0.05), with short teeth having the smallest mean values. There are no significant differences between two sides (P > 0.05). CONCLUSIONS: The minimal distal dentine thicknesses of MRs in MSMs have close correlation with root length, patient's age and gender.


Assuntos
Cavidade Pulpar/anatomia & histologia , Dentina/anatomia & histologia , Mandíbula/diagnóstico por imagem , Dente Molar/anatomia & histologia , Raiz Dentária/anatomia & histologia , Adolescente , Adulto , China , Tomografia Computadorizada de Feixe Cônico , Cavidade Pulpar/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dente Molar/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem
7.
Sensors (Basel) ; 19(6)2019 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-30901966

RESUMO

A new type of flexible sensor, which could maintain the deformation consistency and achieve the real-time detection of the variation in load of the measured object, was proposed in this work. According to the principle of forced assembly, PDMS was used as the substrate of sensitive components and electrodes, while carbon fiber was added as a conductive medium to prepare a polymer-based flexible sensor, which effectively overcame the deformation limitation and output instability of conventional flexible sensors due to different substrates of sensitive components and the electrode. Combined with the sensor structure and the forced assembly method, a theoretical analysis of its conductive measurement mechanism was carried out. Meanwhile, an experimental test device was designed to test and analyze the output characteristics of the flexible sensor under a static and dynamic alternating load. The results show that the flexible sensor exhibited linear output under the dynamic alternating load of 10 kN to 60 kN and frequency of 3 Hz. Peak and valley value had the same phase with the load extremes. The dynamic and static experiments show that the resistance output signal and the sensitivity was in the range of 310~624.15 Ω and 171⁻183 N/Ω respectively. However, due to the hysteresis of the elastic recovery of the polymer, the output repeatability of the flexible sensor under the dynamic alternating load was 5.03% and 0.78% lower than that of the static load, respectively. Combined with the static and dynamic experiments, it was verified that the polymer-based flexible sensor can maintain the same deformation characteristics with the measured object, and at the same time outputted a resistance signal with a certain mapping relationship with the applied load. The repeatability of the output signal under dynamic and static experiments was within ±7%, which can meet the measurement requirements of the fatigue life of the measured body during periodic load.

8.
Cleft Palate Craniofac J ; 56(7): 936-943, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30621447

RESUMO

OBJECTIVE: To compare osseous outcomes of block and cancellous iliac bone grafting in older unilateral alveolar cleft patients. DESIGN: Retrospective and observational follow-up study. SETTING: Cleft Lip and Palate Centre, Department of Oral and Maxillofacial Surgery, Affiliated Hospital of Stomatology, Nanjing Medical University, China. PATIENTS: Forty-five nonsyndromic patients with unilateral complete alveolar cleft were enrolled in this study (25 patients in block bone graft group and 20 patients in cancellous bone graft group). INTERVENTIONS: In cancellous bone graft group, the alveolar cleft was filled with iliac cancellous bone particulate. In group of block bone graft, the harvested bone block was trimmed and fixed in alveolar defect. MAIN OUTCOME MEASURES: A novel method was proposed to investigate the volume and density of residual bone graft at 1-week, 3- and 6-month, 1- and 2-year postoperatively based on cone beam computed tomography scans. RESULTS: No difference in bone graft volume was found between 2 groups at 1-week and 3-month postoperatively; however, the residual volume of block bone graft group was significantly larger than that of cancellous bone graft group at 6-month, 1- and 2-year postoperatively. The bone density of block bone graft group was lower at 1-week and 3-month postoperatively but was comparable at 6-month, 1- and 2-year postoperatively. Our method was reliable and accurate to identify the range of residual bone graft when the boundary of grafted bone could not be identified clearly. CONCLUSION: Block bone graft could achieve comparable bone density and retain a greater amount of residual bone comparing to cancellous bone graft.


Assuntos
Enxerto de Osso Alveolar , Transplante Ósseo , Osso Esponjoso , Fenda Labial , Fissura Palatina , Osso Esponjoso/transplante , China , Fenda Labial/cirurgia , Fissura Palatina/cirurgia , Seguimentos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
9.
Nanotechnology ; 29(35): 355304, 2018 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-29897348

RESUMO

Multifunctional electronics are attracting great interest with the increasing demand and fast development of wearable electronic devices. Here, we describe an epidermal strain sensor based on an all-carbon conductive network made from multi-walled carbon nanotubes (MWCNTs) impregnated with poly(dimethyl siloxane) (PDMS) matrix through a vacuum filtration process. An ultrasonication treatment was performed to complete the penetration of PDMS resin in seconds. The entangled and overlapped MWCNT network largely enhances the electrical conductivity (1430 S m-1), uniformity (remaining stable on different layers), reliable sensing range (up to 80% strain), and cyclic stability of the strain sensor. The homogeneous dispersion of MWCNTs within the PDMS matrix leads to a strong interaction between the two phases and greatly improves the mechanical stability (ca. 160% strain at fracture). The flexible, reversible and ultrathin (<100 µm) film can be directly attached on human skin as epidermal strain sensors for high accuracy and real-time human motion detection.


Assuntos
Epiderme/fisiologia , Nanotubos de Carbono/química , Papel , Dimetilpolisiloxanos/química , Condutividade Elétrica , Humanos , Movimento (Física) , Nanotubos de Carbono/ultraestrutura , Estresse Mecânico , Termogravimetria
10.
Molecules ; 23(9)2018 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-30217082

RESUMO

Investigation of cell behavior under different environments and manual operations can give information in specific cellular processes. Among all cell-based analysis, single-cell study occupies a peculiar position, while it can avoid the interaction effect within cell groups and provide more precise information. Microfluidic devices have played an increasingly important role in the field of single-cell study owing to their advantages: high efficiency, easy operation, and low cost. In this review, the applications of polymer-based microfluidics on cell manipulation, cell treatment, and cell analysis at single-cell level are detailed summarized. Moreover, three mainly types of manufacturing methods, i.e., replication, photodefining, and soft lithography methods for polymer-based microfluidics are also discussed.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Análise de Célula Única/métodos , Animais , Humanos , Polímeros/química
11.
Molecules ; 23(7)2018 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-30002333

RESUMO

Photodynamic therapy (PDT) is able to non-invasively treat and diagnose various cancers and nonmalignant diseases by combining light, oxygen, and photosensitizers (PSs). However, the application of PDT is hindered by poor water solubility and limited light-penetration depth of the currently available photosensitizers (PSs). Water solubility of PSs is crucial for designing pharmaceutical formulation and administration routes. Wavelength of light source at visible range normally has therapeutic depth less than 1 mm. In this review, focus is on the recent research progress of metal-based nanoparticles being applied in PDT. The potential toxicity of these nanoscales and future directions are further discussed.


Assuntos
Nanopartículas Metálicas/uso terapêutico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Animais , Humanos
12.
BMC Oral Health ; 18(1): 164, 2018 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-30285721

RESUMO

BACKGROUND: Maxillary posterior teeth have close anatomical proximity to the maxillary sinus floor (MSF), and the race, gender, age, side and presence/absence of adjacent teeth may influence the mean distances between the root apices and the MSF. This study aimed to evaluate both the relationship between the maxillary posterior teeth and MSF, and the influence of adjacent teeth loss on the distance between the maxillary posterior roots and MSF. METHODS: Cone-beam computed tomography images were collected from 1011 Chinese patients. The relationship between the maxillary posterior teeth and the MSF was divided into three types: Type OS (the root apex extending below/outside the MSF), Type CO (the root apex contacting with the MSF), Type IS (the root apex extending above/inside the MSF). The minimum vertical distances between the maxillary posterior roots apices and the MSF were recorded. The correlations of the distances with gender and age were analyzed. The distances between the maxillary posterior root apices and the MSF with different types of adjacent teeth loss was evaluated. RESULTS: Type OS was the most common relationship of all posterior root apices (P<0.05). Type IS was highest in the palatal roots (PRs) of the maxillary first molars (MFMs) and the mesiobuccal roots (MBRs) of the maxillary second molars (MSMs) (24.8% and 21.6%) (P<0.05). The frequency of Type IS decreased with age except the premolar roots and PRs of the MSMs (P<0.05). The MBRs of the MSMs had the lowest distances to the MSF (0.8 ± 2.5 mm), followed by the distobuccal roots of the MSMs (1.3 ± 2.7 mm) and the PRs of the MFMs (1.4 ± 3.4 mm) (P<0.05). Age was an important influencing factor to the mean distances while gender had little effects. The distance between the maxillary second premolar root apices and the MSF decreased with the absence of adjacent teeth (P<0.05). CONCLUSIONS: The maxillary molars showed greater proximity to the MSF than premolars. Age had significant impacts on the relationship between maxillary posterior roots and MSF. The absence of maxillary first molars will influence the proximity of maxillary second premolar root apices to MSF.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Maxila/diagnóstico por imagem , Seio Maxilar/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Maxila/anatomia & histologia , Seio Maxilar/anatomia & histologia , Pessoa de Meia-Idade , Dente Molar/anatomia & histologia
13.
ACS Nano ; 18(1): 1226-1236, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38153997

RESUMO

Dielectric elastomer transducers (DETs), with a dielectric elastomer (DE) film sandwiched between two compliant electrodes, are highly sought after in the fields of soft robotics, energy harvesting, and human-machine interaction. To achieve a high-performance DET, it is essential to develop electrodes with high conductivity, strain-insensitive resistance, and adaptability. Herein, we design an electrode (Supra-LMNs) based on multiple dynamic bond cross-linked supramolecular networks (Ns) and liquid metal (LM), which realizes high conductivity (up to 16,000 S cm-1), negligible resistance changes at high strain (1.3-fold increase at 1000% strain), instantaneous self-healability at ambient temperature, and rapid recycling. The conductive pathway can be activated through simple friction by transmitting stress through the silver nanowires (AgNWs) and cross-linking sites of LM particles. This method is especially attractive for printing circuits on flexible substrates, especially DE films. Utilized as dielectric elastomer generator (DEG) electrodes, it reduces the charge loss by 3 orders of magnitude and achieves high generating energy density and energy conversion efficiency on a low-resistance load. Additionally, serving as sensor (DES) and actuator (DEA) electrodes, it enables a highly sensitive sensing capability and complex interaction.

14.
Adv Mater ; 35(22): e2300246, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36932852

RESUMO

Dielectric elastomer generators (DEGs) with high generated energy density and high conversion efficiency are of great interest. Among several dielectric elastomers (DEs), silicone elastomer filled with ceramic fillers have been extensively studied for their high elasticity, insulation, and permittivity. However, the stretched breakdown strength (Ebs ) of such composites decreases significantly under large strain, thus sharply reduces its energy harvesting performances. In this study, a polar rubber-based dielectric (GNBR) is synthetized and creatively used as "soft filler" for silicone elastomer. Benefiting from the deformability under stretching and its inherent strong interface bonding with silicone elastomer, this soft filler effectively avoids the formation of weak interface under large strain and reduces the local field strength of interface area. As expected, the composite filled with soft filler (GNBR/PMVS) shows enhanced Ebs of 2.8 times that of composite with traditional hard filler (TiO2 /PMVS) under equibiaxial strain of 200%. As a result, GNBR/PMVS composite exhibits maximum energy density of 130.5 mJ g-1 with up-to-date highest power conversion efficiency of reported DEG (44.5%). The findings will provide new insights in the rational design of DE composites characterized by high stretched breakdown strength for advanced energy harvesting system.

15.
Polymers (Basel) ; 16(1)2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38201708

RESUMO

In recent years, superhydrophobic surfaces have attracted significant attention due to their promising applications, especially in ice prevention, reduction in air resistance, and self-cleaning. This study utilizes femtosecond laser processing technology to prepare different surface microstructures on polytetrafluoroethylene (PTFE) surfaces. Through experiments, it investigates the relationship between the solid-liquid contact ratio and surface hydrophobicity. The shape of water droplets on different microstructure surfaces is simulated using ANSYS, and the relationship between surface microstructures and hydrophobicity is explored in the theoretical model. A superhydrophobic surface with a contact angle of up to 166° was obtained by machining grooves with different spacings in polytetrafluoroethylene sheets with femtosecond laser technology. Due to the micro- and nanostructures on the surface, the oleophobicity of the processed oleophilic PTFE surface is enhanced.

16.
Artigo em Inglês | MEDLINE | ID: mdl-37453920

RESUMO

OBJECTIVES: We aimed to quantitatively compare the area and volume of artifacts in cone beam computed tomography produced by mesoporous calcium silicate nanoparticles (MCSNs), AH Plus sealer, and iRoot SP sealer when used as root canal sealers. METHODS: We prepared 40 single-rooted mandibular premolars and divided them into an MCSN sealer group, an AH Plus sealer group, an iRoot SP sealer group, and a no-sealer (control) group. We filled the canals with gutta-percha using the single-cone method and subjected them to conebeam computed tomography before and after the placement of root fillings using the same exposure parameters. We evaluated the images to quantify the areas of hyperdense and hypodense artifacts and non-affected teeth and reconstructed 3-dimensional image models of the materials to study volume distortion artifacts. RESULTS: The MCSN sealer group produced a significantly smaller hyperdense and volume distortion artifacts than the AH Plus and iRoot SP groups (P < .01), but the area and volume of hypodense artifacts did not differ significantly among the groups (P > .05). CONCLUSIONS: When used as a root canal sealer, MCSNs generate a significantly smaller area and volume of hyperdense artifacts than AH Plus and iRoot SP sealers. By significantly reducing the generation of high-density artifacts, MCSNs may facilitate the evaluation of root canal filling quality and the diagnosis of root canal abnormalities.


Assuntos
Cavidade Pulpar , Materiais Restauradores do Canal Radicular , Humanos , Artefatos , Guta-Percha , Silicatos , Obturação do Canal Radicular/métodos , Tomografia Computadorizada de Feixe Cônico , Resinas Epóxi , Teste de Materiais
17.
Adv Sci (Weinh) ; 10(9): e2206094, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36658692

RESUMO

High-performance multilayer dielectric elastomer actuators (DEAs) are well-positioned to overcome the insufficient output force and energy density as artificial muscles. However, due to the fabrication process, the multilayer DEAs with nonmodifiable structures often suffer from the limitation of short lifespans and scalable preparation. Herein, reusable multilayer DEAs with the detachable and reconfigurable structure are fabricated. This is achieved by realizing scalable compliant electrodes using the continuous spatial confining forced network assembly (CSNA) method and combining the vacuum lamination (VL) approach to have good attachability and detachability with the VHB dielectric elastomer. The flexible roller-based CSNA method is used to prepare the large area compliant electrodes composed of α, ω-dihydroxy polydimethylsiloxane and electrically conductive nanoparticles. The fabricated electrodes can continuously work over 10 000 cycles at 40% strained stretching and maintain smooth surfaces to construct multilayer DEAs. Moreover, owing to the detachable configuration of the DEAs, the electrodes can also be recovered and reused for building new actuators. The lower limb assistive device is demonstrated by detachable multilayer spring roll DEAs, achieving approximately 3.1 degrees of flexion and extension movement of knee models under a voltage of 7 kV. The detachable and reconfigurable multilayer DEAs shed new light on the applications of wearable assistive devices.

18.
NanoImpact ; 25: 100392, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35559896

RESUMO

Quantum dots (QDs), also known as semiconductor QDs, have specific photoelectricproperties which find application in bioimaging, solar cells, and light-emitting diodes (LEDs). However, the application of QDs is often limited by issues related to health risks and potential toxicity. The purpose of this study was to provide evidence regarding the safety of cadmium telluride (CdTe) QDs by exploring the detailed mechanisms involved in its hepatotoxicity. This study showed that CdTe QDs can increase reactive oxygen species (ROS) in hepatocytes after being taken up by hepatocytes, which triggers a significant mitochondrial-dependent apoptotic pathway, leading to hepatocyte apoptosis. CdTe QDs-induce mitochondrial cristae abnormality, adenosine triphosphate (ATP) depletion, and mitochondrial membrane potential (MMP) depolarization. Meanwhile, CdTe QDs can change the morphology, function, and quantity of mitochondria by reducing fission and intimal fusion. Importantly, inhibition of ROS not only protects hepatocyte viability but can also interfere with apoptosis and activation of mitochondrial dysfunction. Similarly, the exposure of CdTe QDs in Institute of Cancer Research (ICR) mice showed that CdTe QDs caused oxidative damage and apoptosis in liver tissue. NAC could effectively remove excess ROS could reduce the level of oxidative stress and significantly alleviate CdTe QDs-induced hepatotoxicity in vivo. CdTe QDs-induced hepatotoxicity may originate from the generation of intracellular ROS, leading to mitochondrial dysfunction and apoptosis, which was potentially regulated by mitochondrial dynamics. This study revealed the nanobiological effects of CdTe QDs and the intricate mechanisms involved in its toxicity at the tissue, cell, and subcellular levels and provides information for narrowing the gap between in vitro and in vivo animal studies and a safety assessment of QDs.


Assuntos
Compostos de Cádmio , Doença Hepática Induzida por Substâncias e Drogas , Pontos Quânticos , Animais , Apoptose , Compostos de Cádmio/toxicidade , Camundongos , Mitocôndrias , Pontos Quânticos/toxicidade , Espécies Reativas de Oxigênio/metabolismo , Telúrio/toxicidade
19.
Front Genet ; 13: 856671, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35899200

RESUMO

Background: Here, we establish a prognostic signature based on glycosyltransferase-related genes (GTRGs) for head and neck squamous cell carcinoma (HNSCC) patients. Methods: The prognostic signature of GTRGs was constructed via univariate and multivariate Cox analyses after obtaining the expression patterns of GTRGs from the TCGA. A nomogram based on the signature and clinical parameters was established to predict the survival of each HNSCC patient. Potential mechanisms were explored through gene set enrichment analysis (GSEA) and immune cell infiltration, immune checkpoints, immunotherapy, and tumor mutational burden (TMB) analyses. The expression differences and prognostic efficacy of the signature were verified through the gene expression omnibus (GEO) and several online databases. Results: The prognostic signature was constructed based on five glycosyltransferases (PYGL, ALG3, EXT2, FUT2, and KDELC1) and validated in the GSE65858 dataset. The pathways enriched in the high- and low-risk groups were significantly different. The high-risk group had higher tumor purity; lower infiltration of immune cells, such as CD8+ T cells and Tregs; higher cancer-associated fibroblast (CAF) infiltration; lower immune function; and lower checkpoint expression. The signature can also be applied to distinguish whether patients benefit from immunotherapy. In addition, the high-risk group had a higher TMB and more gene mutations, including those in TP53, CSMD1, CDKN2A, and MUC17. Conclusion: We propose a prognostic signature based on glycosyltransferases for HNSCC patients that may provide potential targets and biomarkers for the precise treatment of HNSCC.

20.
Sheng Wu Gong Cheng Xue Bao ; 38(6): 2281-2291, 2022 Jun 25.
Artigo em Zh | MEDLINE | ID: mdl-35786479

RESUMO

As a new transdermal drug delivery technology, bubble microneedle could achieve painless and precise drug delivery, which has attracted great attention from researchers. In order to improve the utilization rate of the drug carried by microneedle, we proposed a method for preparing a tip-loaded bubble-soluble microneedle. During the molding process of the microneedle, air bubbles were formed in the needle body, and the drug was concentrated on the needle tip. The preparation process of the bubble microneedle was optimized. The effects of foaming agent concentration, drying temperature, and solution viscosity on the forming of bubble microneedles were explored. Furthermore, the transdermal effect of the product was analyzed. The experimental results showed that the bubble microneedle forming process was stable, with the forming rate above 90% and the forming cycle shortened to about 4 h. The drug was mainly concentrated on the tip of the microneedle, with a length of 180 µm, and the length of the bubble was 250 µm. Moreover, the microneedle array can create microchannels on the mouse skin, and the needle bodies can be rapidly dissolved within 5 min. The bubble microneedle could rapidly release about 48% of the drug within 1 min and about 91% of the drug within 5 min. The bubble microstructure of the microneedle array hindered the diffusion of the drug to the substrate, which improves the utilization rate of the drug. This study provides a technical basis for the practical application of microneedle for transdermal drug delivery.


Assuntos
Sistemas de Liberação de Medicamentos , Agulhas , Administração Cutânea , Animais , Sistemas de Liberação de Medicamentos/métodos , Camundongos , Preparações Farmacêuticas
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa