Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Cereb Cortex ; 34(1)2024 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-38102948

RESUMO

The insula plays a significant role in the neural mechanisms of obsessive-compulsive disorder. Previous studies have identified functional and structural abnormalities in insula in obsessive-compulsive disorder patients. The predictive coding model in the context of interoception can explain the psychological and neuropathological manifestations observed in obsessive-compulsive disorder. The model is based on the degree of laminar differentiation of cerebral cortex. The interindividual differences in a local measure of brain structure often covary with interindividual differences in other brain regions. We investigated the anatomical network involving the insula in a drug-naïve obsessive-compulsive disorder sample. We recruited 58 obsessive-compulsive disorder patients and 84 matched health controls. The cortical thickness covariance maps between groups were compared at each vertex. We also evaluated the modulation of Yale-Brown Obsessive-Compulsive Scale scores and obsessive-compulsive disorder duration on thickness covariance. Our findings indicated that the thickness covariance seeded from granular and dysgranular insula are different compared with controls. The duration and severity of obsessive-compulsive disorder can modulate the thickness covariance of granular and dysgranular insula with posterior cingulate cortex and rostral anterior cingulate cortex. Our results revealed aberrant insular structural characteristics and cortical thickness covariance in obsessive-compulsive disorder patients, contributing to a better understanding of the involvement of insula in the pathological mechanisms underlying obsessive-compulsive disorder.


Assuntos
Imageamento por Ressonância Magnética , Transtorno Obsessivo-Compulsivo , Humanos , Imageamento por Ressonância Magnética/métodos , Córtex Cerebral/patologia , Transtorno Obsessivo-Compulsivo/diagnóstico por imagem , Giro do Cíngulo , Encéfalo
2.
Radiology ; 312(3): e240038, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39315897

RESUMO

Background Traditional energy-integrating detector CT has limited utility in accurately quantifying liver fat due to protocol-induced CT value shifts, but this limitation can be addressed by using photon-counting detector (PCD) CT, which allows for a standardized CT value. Purpose To develop and validate a universal CT to MRI fat conversion formula to enhance fat quantification accuracy across various PCD CT protocols relative to MRI proton density fat fraction (PDFF). Materials and Methods In this prospective study, the feasibility of fat quantification was evaluated in phantoms with various nominal fat fractions. Five hundred asymptomatic participants and 157 participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) were enrolled between September 2023 and March 2024. Participants were randomly assigned to six groups with different CT protocols regarding tube voltage (90, 120, or 140 kVp) and radiation dose (standard or low). Of the participants in the 120-kVp standard-dose asymptomatic group, 51% (53 of 104) were designated as the training cohort, with the rest of the asymptomatic group serving as the validation cohort. A CT to MRI fat quantification formula was derived from the training cohort to estimate the CT-derived fat fraction (CTFF). CTFF agreement with PDFF and its error were evaluated in the asymptomatic validation cohort and subcohorts stratified by tube voltage, radiation dose, and body mass index, and in the MASLD cohort. The factors influencing CTFF error were further evaluated. Results In the phantoms, CTFF showed excellent agreement with nominal fat fraction (intraclass correlation coefficient, 0.98; mean bias, 0.2%). A total of 412 asymptomatic participants and 122 participants with MASLD were included. A CT to MRI fat conversion formula was derived as follows: MRI PDFF (%) = -0.58 · CT (HU) + 43.1. Across all comparisons, CTFF demonstrated excellent agreement with PDFF (mean bias values < 1%). CTFF error was not influenced by tube voltage, radiation dose, body mass index, or PDFF. Agreement between CTFF and PDFF was also found in the MASLD cohort (mean bias, -0.2%). Conclusion Standardized CT value from PCD CT showed a robust and remarkable agreement with MRI PDFF across various protocols and may serve as a precise alternative for liver fat quantification. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Wildman-Tobriner in this issue.


Assuntos
Estudos de Viabilidade , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Fígado/diagnóstico por imagem , Adulto , Fígado Gorduroso/diagnóstico por imagem , Idoso , Fótons
3.
Eur Radiol ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38981889

RESUMO

OBJECTIVES: This study examines the effectiveness of dual-energy CT (DECT) delayed-phase extracellular volume (ECV) fraction in predicting tumor regression grade (TRG) in far-advanced gastric cancer (FAGC) patients receiving preoperative immuno-chemotherapy. MATERIALS AND METHODS: A retrospective analysis was performed on far-advanced gastric adenocarcinoma patients treated with preoperative immuno-chemotherapy at our institution from August 2019 to March 2023. Patients were categorized based on their TRG into pathological complete response (pCR) and non-pCR groups. ECV was determined using the delayed-phase iodine maps. In addition, tumor iodine densities and standardized iodine ratios were meticulously analyzed using the triple-phase enhanced iodine maps. Univariate analysis with five-fold cross-validation and Spearman correlation determined DECT parameters and clinical indicators association with pCR. The predictive accuracy of these parameters for pCR was evaluated using a weighted logistic regression model with five-fold cross-validation. RESULTS: Of the 88 patients enrolled (mean age 60.8 ± 11.1 years, 63 males), 21 (23.9%) achieved pCR. Univariate analysis indicated ECV's significant role in differentiating between pCR and non-pCR groups (average p value = 0.021). In the logistic regression model, ECV independently predicted pCR with an average odds ratio of 0.911 (95% confidence interval, 0.798-0.994). The model, incorporating ECV, tumor area, and IDAV (the relative change rate of iodine density from venous phase to arterial phase), showed an average area under curves (AUCs) of 0.780 (0.770-0.791) and 0.766 (0.731-0.800) for the training and validation sets, respectively, in predicting pCR. CONCLUSION: DECT-derived ECV fraction is a valuable predictor of TRG in FAGC patients undergoing preoperative immuno-chemotherapy. CLINICAL RELEVANCE STATEMENT: This study demonstrates that DECT-derived extracellular volume fraction is a reliable predictor for pathological complete response in far-advanced gastric cancer patients receiving preoperative immuno-chemotherapy, offering a noninvasive tool for identifying potential treatment beneficiaries.

4.
Eur Radiol ; 34(9): 5654-5665, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38409549

RESUMO

OBJECTIVES: To compare the diagnostic performance of machine learning (ML)-based computed tomography-derived fractional flow reserve (CT-FFR) and cardiac magnetic resonance (MR) perfusion mapping for functional assessment of coronary stenosis. METHODS: Between October 2020 and March 2022, consecutive participants with stable coronary artery disease (CAD) were prospectively enrolled and underwent coronary CTA, cardiac MR, and invasive fractional flow reserve (FFR) within 2 weeks. Cardiac MR perfusion analysis was quantified by stress myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). Hemodynamically significant stenosis was defined as FFR ≤ 0.8 or > 90% stenosis on invasive coronary angiography (ICA). The diagnostic performance of CT-FFR, MBF, and MPR was compared, using invasive FFR as a reference. RESULTS: The study protocol was completed in 110 participants (mean age, 62 years ± 8; 73 men), and hemodynamically significant stenosis was detected in 36 (33%). Among the quantitative perfusion indices, MPR had the largest area under receiver operating characteristic curve (AUC) (0.90) for identifying hemodynamically significant stenosis, which is in comparison with ML-based CT-FFR on the vessel level (AUC 0.89, p = 0.71), with comparable sensitivity (89% vs 79%, p = 0.20), specificity (87% vs 84%, p = 0.48), and accuracy (88% vs 83%, p = 0.24). However, MPR outperformed ML-based CT-FFR on the patient level (AUC 0.96 vs 0.86, p = 0.03), with improved specificity (95% vs 82%, p = 0.01) and accuracy (95% vs 81%, p < 0.01). CONCLUSION: ML-based CT-FFR and quantitative cardiac MR showed comparable diagnostic performance in detecting vessel-specific hemodynamically significant stenosis, whereas quantitative perfusion mapping had a favorable performance in per-patient analysis. CLINICAL RELEVANCE STATEMENT: ML-based CT-FFR and MPR derived from cardiac MR performed well in diagnosing vessel-specific hemodynamically significant stenosis, both of which showed no statistical discrepancy with each other. KEY POINTS: • Both machine learning (ML)-based computed tomography-derived fractional flow reserve (CT-FFR) and quantitative perfusion cardiac MR performed well in the detection of hemodynamically significant stenosis. • Compared with stress myocardial blood flow (MBF) from quantitative perfusion cardiac MR, myocardial perfusion reserve (MPR) provided higher diagnostic performance for detecting hemodynamically significant coronary artery stenosis. • ML-based CT-FFR and MPR from quantitative cardiac MR perfusion yielded similar diagnostic performance in assessing vessel-specific hemodynamically significant stenosis, whereas MPR had a favorable performance in per-patient analysis.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Aprendizado de Máquina , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Idoso , Angiografia por Tomografia Computadorizada/métodos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X/métodos
5.
Eur Radiol ; 34(10): 6568-6577, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38676731

RESUMO

OBJECTIVES: This study aimed to compare the image quality and diagnostic performance of standard-resolution (SR) and ultra-high-resolution (UHR) coronary CT angiography (CCTA) based on photon-counting detector CT (PCD-CT) of coronary stents and explore the best reconstruction kernel for stent imaging. METHODS: From July 2023 to September 2023, patients were enrolled to undergo CCTA using a dual-source PCD-CT system after coronary angioplasty with stent placement. SR images with a slice thickness/increment of 0.6/0.4 mm were reconstructed using a vascular kernel (Bv48), while UHR images with a slice thickness/increment of 0.2/0.2 mm were reconstructed using vascular kernels of six sharpness levels (Bv48, Bv56, Bv60, Bv64, Bv72, and Bv76). The in-stent lumen diameters were evaluated. Subjective image quality was also evaluated by a 5-point Likert scale. Invasive coronary angiography was conducted in 12 patients (25 stents). RESULTS: Sixty-nine patients (68.0 [61.0, 73.0] years, 46 males) with 131 stents were included. All UHR images had significantly larger in-stent lumen diameter than SR images (p < 0.001). Specifically, UHR-Bv72 and UHR-Bv76 for in-stent lumen diameter (2.17 [1.93, 2.63] mm versus 2.20 [1.93, 2.59] mm) ranked the two best kernels. The subjective analysis demonstrated that UHR-Bv72 images had the most pronounced effect on reducing blooming artifacts, showcasing in-stent lumen and stent demonstration, and diagnostic confidence (p < 0.001). Furthermore, SR and UHR-Bv72 images showed a diagnostic accuracy of 78.3% (95% confidence interval [CI]: 56.3%-92.5%) and 88.0% (95%CI: 68.8%-97.5%), respectively. CONCLUSION: UHR CCTA by PCD-CT leads to significantly improved visualization and diagnostic performance of coronary stents, and Bv72 is the optimal reconstruction kernel showing the stent struts and in-stent lumen. CLINICAL RELEVANCE STATEMENT: The significantly improved visualization of coronary stents using ultra-high resolution CCTA could increase the diagnostic accuracy for in-stent restenosis and avoid unnecessary invasive quantitative coronary angiography, thus changing the clinical management for patients after percutaneous coronary intervention. KEY POINTS: Coronary stent imaging is challenging with energy-integrating detector CT due to "blooming artifacts." UHR images using a PCD-CT enhanced coronary stent visualization. UHR coronary stent imaging demonstrated improved diagnostic accuracy in clinical settings.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Stents , Humanos , Feminino , Masculino , Idoso , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Pessoa de Meia-Idade , Fótons , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia
6.
Inflamm Res ; 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39235607

RESUMO

BACKGROUND: Dysfunctional immune regulation plays a crucial role in the pathogenesis of airway allergies. Macrophages are one of the components of the immune regulation cells. The aim of this study is to elucidate the role of lysine demethylase 5 A (KDM5A) in maintaining macrophages' immune regulatory ability. METHODS: DNA was extracted from Lactobacillus rhamnosus GG to be designated as LgDNA. LgDNA was administered to the mice through nasal instillations. M2 macrophages (M2 cells) were isolated from the airway tissues using flow cytometry. RESULTS: We found that airway M2 cells of mice with airway Th2 polarization had reduced amounts of IL-10 and KDM5A. Mice with Kdm5a deficiency in M2 cells showed the airway Th2 polarization. The expression of Kdm5a in airway M2 cells was enhanced by nasal instillations containing LgDNA. KDM5A mediated the effects of LgDNA on inducing the Il10 expression in airway M2 cells. Administration of LgDNA mitigated experimental airway allergy. CONCLUSIONS: M2 macrophages in the airway tissues of mice with airway allergy show low levels of KDM5A. By upregulating KDM5A expression, LgDNA can increase Il10 expression and reconcile airway Th2 polarization.

7.
AJR Am J Roentgenol ; 222(5): e2330631, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38323783

RESUMO

BACKGROUND. Use of virtual monoenergetic images (VMIs) from multienergy CT scans can mitigate inconsistencies in traditional attenuation measurements that result from variation in scan-related factors. Photon-counting detector (PCD) CT systems produce VMIs as standard image output under flexible scanning conditions. OBJECTIVE. The purpose of this article was to evaluate the consistency of monoenergetic attenuation measurements obtained from a clinical PCD CT scanner across a spectrum of scanning paradigms. METHODS. A phantom with 10 tissue-simulating inserts was imaged using a clinical dual-source PCD CT scanner. Nine scanning paradigms were obtained across combinations of tube voltages (90, 120, and 140 kVp) and image quality (IQ) levels (80, 145, and 180). Images were reconstructed at VMI levels of 50, 60, 70, and 80 keV. Consistency of attenuation measurements was assessed, using the 120 kVp with IQ level of 145 scanning paradigm as the reference scan. RESULTS. For all scanning paradigms, attenuation measurements showed intra-class correlation of 0.999 and higher with respect to the reference scan. Across inserts, mean bias relative to the reference scan ranged from -14.9 to 13.6 HU, -2.7 to 1.7 HU, and -3.9 to 3.8 HU at tube voltages of 90, 120, and 140 kVp, respectively; and from -14.9 to 13.6 HU, -6.4 to 3.8 HU, -3.7 to 1.4 HU, and -7.2 to 4.3 HU at VMI levels of 50, 60, 70, and 80 keV, respectively. Thus, mean bias did not exceed 5 HU for any insert at tube potentials of 120 kVp and 140 kVp, nor for any insert at a VMI level of 70 keV. At a VMI level of 50 keV and tube potential of 90 kVp, mean bias exceeded 5 HU for 14 of 30 possible combinations of inserts and scanning paradigms and exceeded 10 HU for four of 30 such combinations. At VMI levels of both 60 and 80 keV, mean bias exceeded 5 HU for only two combinations of inserts and scanning paradigms, all at a tube potential of 90 kVp. CONCLUSION. PCD CT generally provided consistent attenuation measurements across combinations of scanning paradigms and VMI levels. CLINICAL IMPACT. PCD CT may facilitate quantitative applications of CT data in clinical practice.


Assuntos
Imagens de Fantasmas , Fótons , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes
8.
J Biol Chem ; 298(12): 102590, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36244453

RESUMO

Type A γ-aminobutyric acid receptors (GABAARs) represent a family of pentameric GABA-gated Cl-/HCO3- ion channels which mediate inhibitory transmission in the central nervous system. Cell surface expression of GABAARs, a prerequisite for their function, is dependent on the appropriate assembly of the receptor subunits and their transient interactions with molecular chaperones within the endoplasmic reticulum (ER) and Golgi apparatus. Here, we describe a highly conserved amino acid sequence within the extracellular N-terminal domain of the receptor subunits adjoining the first transmembrane domain as a region important for GABAAR processing within the ER. Modifications of this region in the α1, ß3, and γ2 subunits using insertion or site-directed mutagenesis impaired GABAAR trafficking to the cell surface in heterologous cell systems although they had no effect on the subunit assembly. We found that mutated receptors accumulated in the ER where they were shown to associate with chaperones calnexin, BiP, and Grp94. However, their surface expression was increased when ER-associated degradation or proteosome function was inhibited, while modulation of ER calcium stores had little effect. When compared to the wt, mutated receptors showed decreased interaction with calnexin, similar binding to BiP, and increased association with Grp94. Structural modeling of calnexin interaction with the wt or mutated GABAAR revealed that disruption in structure caused by mutations in the conserved region adjoining the first transmembrane domain may impair calnexin binding. Thus, this previously uncharacterized region plays an important role in intracellular processing of GABAARs at least in part by stabilizing their interaction with calnexin.


Assuntos
Proteínas de Transporte , Receptores de GABA-A , Animais , Camundongos , Calnexina/genética , Calnexina/metabolismo , Espaço Extracelular/metabolismo , Ácido gama-Aminobutírico/metabolismo , Chaperonas Moleculares/metabolismo , Receptores de GABA-A/genética , Receptores de GABA-A/metabolismo , Subunidades Proteicas/metabolismo
9.
Acta Radiol ; 64(4): 1311-1321, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36062762

RESUMO

BACKGROUND: A non-invasive tool for tumor regression grade (TRG) evaluation is urgently needed for gastric cancer (GC) treated with neoadjuvant chemotherapy (NAC). PURPOSE: To develop and validate a radiomics signature (RS) to evaluate TRG for locally advanced GC after NAC and assess its prognostic value. MATERIAL AND METHODS: A total of 103 patients with GC treated with NAC were retrospectively recruited from April 2018 to December 2019 and were randomly allocated into a training cohort (n = 69) and a validation cohort (n = 34). Delineation was performed on both mixed and iodine-uptake images based on dual-energy computed tomography (DECT). A total of 4094 radiomics features were extracted from the pre-NAC, post-NAC, and delta feature sets. Spearman correlation and the least absolute shrinkage and selection operator were used for dimensionality reduction. Multivariable logistic regression was used for TRG evaluation and generated the optimal RS. Kaplan-Meier survival analysis with the log-rank test was implemented in an independent cohort of 40 patients to validate the prognostic value of the optimal RS. RESULTS: Three, five, and six radiomics features were finally selected for the pre-NAC, post-NAC, and delta feature sets. The delta model demonstrated the best performance in assessing TRG in both the training and the validation cohorts (AUCs=0.91 and 0.76, respectively; P>0.1). The optimal RS from the delta model showed a significant capability to predict survival in the independent cohort (P<0.05). CONCLUSION: Delta radiomics based on DECT images serves as a potential biomarker for TRG evaluation and shows prognostic value for patients with GC treated with NAC.


Assuntos
Neoplasias Gástricas , Humanos , Prognóstico , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/tratamento farmacológico , Terapia Neoadjuvante , Estudos Retrospectivos , Tomografia
10.
J Am Chem Soc ; 144(34): 15497-15508, 2022 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-35979963

RESUMO

Bicontinuous porous materials, which possess 3D interconnected pore channels facilitating a smooth mass transport, have attracted much interest in the fields of energy and catalysis. However, their synthesis remains very challenging. We report a general approach, using polymer cubosomes as the template, for the controllable synthesis of bicontinuous porous polymers with an ordered single primitive (SP) cubic structure, including polypyrrole (SP-PPy), poly-m-phenylenediamine (SP-PmPD), and polydopamine (SP-PDA). Specifically, the resultant SP-PPy had a unit cell parameter of 99 nm, pore diameter of 45 nm, and specific surface area of approximately 60 m2·g-1. As a proof of concept, the I2-adsorbed SP-PPy was employed as the cathode materials of newly emerged Na-I2 batteries, which delivered a record-high specific capacity (235 mA·h·g-1 at 0.5 C), excellent rate capability, and cycling stability (with a low capacity decay of 0.12% per cycle within 400 cycles at 1 C). The advantageous contributions of the bicontinuous structure and I3- adsorption mechanism of SP-PPy were revealed by a combination of ion diffusion experiments and theoretical calculations. This study opens a new avenue for the synthesis of porous polymers with new topologies, broadens the spectrum of bicontinuous-structured materials, and also develops a novel potential application for porous polymers.


Assuntos
Iodo , Polímeros , Polímeros/química , Porosidade , Pirróis/química , Sódio
11.
Eur Radiol ; 32(9): 6028-6036, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35389051

RESUMO

OBJECTIVES: To investigate the perivascular fat attenuation index (FAI) in association with epicardial adipose tissue (EAT) parameters and its distribution over the entire coronary vasculature in patients with known or suspected coronary artery disease (CAD). METHODS: Patients with known or suspected CAD who underwent coronary computed tomography angiography from January 1, 2019, to June 1, 2019, were retrospectively included. The perivascular FAI was quantified on four main epicardial coronary arteries and seven coronary segments. Moreover, EAT density and volume were measured. RESULTS: We included 192 consecutive patients (55 without coronary plaque [mean age 46.4 ± 13.2 years, 69.1% male] and 137 with coronary plaque [mean age 57.9 ± 13.0 years, 84.7% male]). EAT density was lower than perivascular FAI in both groups, but they exhibited substantial correlation (- 83.33 ± 4.54 vs. - 78.22 ± 6.52 HU, p < 0.001; r = 0.667 in plaque- patients and - 83.11 ± 4.48 vs. - 77.81 ± 5.63 HU, p < 0.001; r = 0.778 in plaque+ patients). The left main coronary artery had the highest perivascular FAI, followed by the left circumflex artery. The perivascular FAI in proximal segments was significantly higher compared to that in distal segments (all p < 0.05). Furthermore, the presence of plaque did not alter perivascular FAI on the patient or segmental level. CONCLUSION: The perivascular FAI was significantly higher than EAT density and correlated substantially with EAT density. The perivascular FAI distribution over the entire coronary tree varied and prompted for vessel-specific or segment-specific thresholds to determine abnormal perivascular FAI in practice. KEY POINTS: • The perivascular FAI correlated well with EAT density and had higher values than EAT density. • The distributions of perivascular FAI differ between coronary vessels or segments; considering segment and vessel confounding factors while conducting a perivascular FAI study is necessary. • No significant difference of perivascular FAI was observed between patients without and with coronary plaque, nor between coronary segments without plaque and those with plaque.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Tecido Adiposo/diagnóstico por imagem , Adulto , Idoso , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Pericárdio/diagnóstico por imagem , Placa Aterosclerótica/complicações , Estudos Retrospectivos
12.
Eur Radiol ; 32(12): 8111-8121, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35727319

RESUMO

OBJECTIVES: The presence of non-alcoholic fatty liver disease (NAFLD) has been associated with major adverse cardiovascular events (MACEs); however, the mechanisms that initiate the risk for MACEs in patients with NAFLD remain unknown. We sought to investigate whether plaque progression (PP), determined by coronary CT angiography (CCTA), moderate the relationship between NAFLD and MACEs. METHODS: A total of 1683 asymptomatic participants (mean age, 63.3 ± 9.4 [range, 38-85] years; 1117 men) who underwent baseline and follow-up CCTA examination were prospectively included in our study. All of the participants were divided into the NAFLD and non-NAFLD groups. PP was determined by follow-up CCTA. The primary endpoint was MACEs, defined as the composite of all-cause death, nonfatal myocardial infarction, and unplanned hospitalization for acute coronary syndrome leading to revascularization. RESULTS: At follow-up CCTA, participants with NAFLD showed higher incidence of PP than those without [33.0% (248/752) vs. 16.6% (155/931), p < 0.001]. Compared with non-NAFLD participants, participants with NAFLD had a lower 9.7-year event-free survival rate (80.9 vs. 66.4%, log-rank p < 0.001). Cox regression analysis revealed NAFLD was significantly associated with MACEs (HR = 1.63, 95% CI: 1.28 to 2.06, p < 0.001) after adjusting for covariables. However, this association was no longer significant after adjustment for PP (HR = 1.10, 95% CI: 0.84 to 1.45, p = 0.496). The mediation analysis revealed that PP had a significant indirect effect (ß = 0.0587, 95% CI: 0.0424 to 0.08, p < 0.001) and mediated 99.8% (p = 0.002) for the relationship between NAFLD and MACEs. CONCLUSIONS: Plaque progression, identified by follow-up CCTA, mediates the relationship between NAFLD and MACEs. KEY POINTS: The incidence of CCTA-identified PP was higher for participants with NAFLD than those without NAFLD (248/752 [33.0%] vs. 155/931 [16.6%], p < 0.001). Participants with NAFLD had a lower 9.7-year event-free survival rate than those without NAFLD (66.4% vs. 80.9%, log-rank p < 0.001). The mediation analysis revealed that PP had a significant indirect effect (ß = 0.0587, 95% CI: 0.0424 to 0.08, p < 0.001) and mediated 99.8% (p = 0.002) for the relationship between NAFLD and MACEs.


Assuntos
Doença da Artéria Coronariana , Hepatopatia Gordurosa não Alcoólica , Placa Aterosclerótica , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Angiografia por Tomografia Computadorizada , Estudos Prospectivos , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/complicações , Prognóstico , Angiografia Coronária , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/complicações , Fatores de Risco
13.
Dermatology ; 238(3): 562-570, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34535598

RESUMO

OBJECTIVES: This study aimed to evaluate coronary inflammation by measuring the perivascular fat attenuation index (FAI) and quantify the atherosclerosis burden in patients with psoriasis and control individuals without psoriasis based on coronary computed tomography angiography (CCTA) images. METHODS: A total of 98 consecutive patients with psoriasis (76 male [77.6%], aged 56.5 years, range 45.5-65.0) were recruited, and 196 patients (157 male [80.1%]; aged 54.6 ± 14.1 years) without established cardiovascular disease (CVD) who underwent CCTA within the same period were enrolled in the control group. Coronary plaque burden was quantified using the computed tomography-adapted Leaman score (CT-LeSc), and the FAI surrounding the proximal of three main epicardial vessels was measured to represent coronary inflammation. RESULTS: Patients with psoriasis and the control subjects were well matched in CVD risk factors (all p > 0.05). Psoriasis patients had a greater overall CT-LeSc (5.86 vs. 4.69, p = 0.030) and lower perivascular FAI (-80.19 ± 7.48 vs. -78.14 ± 7.81 HU, p < 0.001). A similar result was found upon comparing psoriasis patients without biological or statin therapy with non-psoriasis individuals without statin treatments. Furthermore, the psoriasis group had a higher prevalence of non-calcified plaques (30.3% in the psoriasis group vs. 20.1% in the control subjects, p = 0.001). No difference in perivascular FAI on either calcified and mixed plaques or non-calcified plaques between the two groups was found. CONCLUSION: Patients with psoriasis have a higher atherosclerotic burden as quantified by CT-LeSc and less coronary inflammation as detected by perivascular FAI around the most proximal of the three major epicardial vessels. The usefulness of perivascular FAI for evaluating coronary inflammation in patients with chronic low-grade inflammatory disease such as psoriasis should be verified.


Assuntos
Doença da Artéria Coronariana , Inibidores de Hidroximetilglutaril-CoA Redutases , Placa Aterosclerótica , Psoríase , Tecido Adiposo/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Inflamação/diagnóstico por imagem , Masculino , Valor Preditivo dos Testes , Pontuação de Propensão , Psoríase/complicações , Psoríase/diagnóstico por imagem
14.
Cogn Process ; 21(2): 261-270, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31953644

RESUMO

Previous studies have shown that exogenous attention decreases audiovisual integration (AVI); however, whether the interaction between exogenous attention and AVI is influenced by cue-target onset asynchrony (CTOA) remains unclear. To clarify this matter, twenty participants were recruited to perform an auditory/visual discrimination task, and they were instructed to respond to the target stimuli as rapidly and accurately as possible. The analysis of the mean response times showed an effective cueing effect under all cued conditions and significant response facilitation for all audiovisual stimuli. A further comparison of the differences between the probability of audiovisual cumulative distributive functions (CDFs) and race model CDFs showed that the AVI latency was shortened under the cued condition relative to that under the no-cue condition, and there was a significant break point when the CTOA was 200 ms, with a decrease in the AVI upon going from 100 to 200 ms and an increase upon going from 200 to 400 ms. These results indicated different mechanisms for the interaction between exogenous attention and the AVI under the shorter and longer CTOA conditions and further suggested that there may be a temporal window in which the AVI effect is mainly affected by exogenous attention, but the interaction might be interfered with by endogenous attention when exceeding the temporal window.


Assuntos
Atenção/fisiologia , Percepção Auditiva/fisiologia , Discriminação Psicológica/fisiologia , Percepção Visual/fisiologia , Adulto , Sinais (Psicologia) , Feminino , Humanos , Masculino , Estimulação Luminosa , Tempo de Reação/fisiologia , Adulto Jovem
15.
Perception ; 48(6): 515-529, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31046568

RESUMO

Temporal expectation relies on different predictive information, such as regular rhythms and symbolic cues, to direct attention to a future moment in time to optimize behaviour. However, whether differences exist between temporal expectations driven by regular rhythms and symbolic cues has not been clearly established. In this study, 20 participants performed two temporal expectation tasks in which a rhythmic cue or a symbolic cue indicated (70% expected) that the target would appear after an interval of 500 ms (short), 1,500 ms (medium), or 2,500 ms (long). We found larger cueing effects for the rhythmic cued task than for the symbolic cued task during the short interval, indicating that rhythmic cues were more effective in improving performance. Furthermore, no significant difference was found during the longer interval, reflect that the behavioural differences between the two forms of temporal expectations were likely to diminish as the time interval increased. Thus, we speculate that the temporal expectation driven by rhythmic cues differs from that driven by symbolic cues only in the limited time range; however, the mechanisms underlying the two forms of temporal expectations trend to become more similar over increasing temporal scales.


Assuntos
Sinais (Psicologia) , Motivação , Percepção do Tempo , Adulto , Feminino , Humanos , Masculino , Estimulação Luminosa , Tempo de Reação , Adulto Jovem
16.
Acad Radiol ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38772799

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the feasibility of using photon-counting detector computed tomography (PCD CT) to simultaneously quantify fat and iron content MATERIALS AND METHODS: Phantoms with pure fat, pure iron and fat-iron deposition were scanned by two tube voltages (120 and 140 kV) and two image quality (IQ) settings (80 and 145). Using an iron-specific three-material decomposition algorithm, virtual noniron (VNI) and virtual iron content (VIC) images were generated at quantum iterative reconstruction (QIR) strength levels 1-4. RESULTS: Significant linear correlations were observed between known fat content (FC) and VNI for pure fat phantoms (r = 0.981-0.999, p < 0.001) and between known iron content (IC) and VIC for pure iron phantoms (r = 0.897-0.975, p < 0.001). In fat-iron phantoms, the measurement for fat content of 5-30% demonstrated good linearity between FC and VNI (r = 0.919-0.990, p < 0.001), and VNI were not affected by 75, 150, and 225 µmol/g iron overload (p = 0.174-0.519). The measurement for iron demonstrated a linear range of 75-225 µmol/g between IC and VIC (r = 0.961-0.994, p < 0.001) and VIC was not confounded by the coexisting 5%, 20%, and 30% fat deposition (p = 0.943-0.999). The Bland-Altman of fat and iron measurements were not significantly different at varying tube voltages and IQ settings (all p > 0.05). No significant difference in VNI and VIC at QIR 1-4. CONCLUSION: PCD CT can accurately and simultaneously quantify fat and iron, including scan parameters with lower radiation dose.

17.
Eur J Radiol ; 177: 111545, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38878499

RESUMO

OBJECTIVE: Fat deposition is an important marker of many metabolic diseases. As a noninvasive and convenient examination method, CT has been widely used for fat quantification. With the clinical application of photon-counting detector (PCD)-CT, we aimed to investigate the accuracy, stability, and dose level of PCD-CT using various scan settings for fat quantification. MATERIALS AND METHODS: Eleven agar-based lipid-containing phantoms (vials with different fat fractions [FFs]; range: 0 %-100 %) were scanned using PCD-CT. Three scanning types (sequence scan, regular spiral scan with a pitch of 0.8, and high-pitch spiral scan with a pitch of 3.2), four tube voltages (90, 120, 140, and 100 kV with a tin filter), and three image quality (IQ) levels (IQ levels of 20, 40, and 80) were alternated, and each scan setting was used twice. For each scan, a 70-keV image was generated using the same reconstruction parameters. A regular spiral scan at 120 kV with IQ80 was used to transfer the CT numbers of all scans to the FF. Intraclass correlation coefficient (ICC) and Bland-Altman analysis were implemented for accuracy and agreement evaluation, and group differences were compared using analysis of variance. RESULTS: Excellent agreement and accuracy of FF derived by PCD-CT with all scan settings was demonstrated by high ICCs (>0.9; range: 0.929-0.998, p < 0.017) and low bias (<5% range: -2.9 %-5%). The root mean square error (RMSE) between the PCD-CT-acquired FF and the reference standard ranged from 1.0 % to 5.0 %, among which the high-pitch scan at 120 kV with IQ20 accounted for the lowest RMSE (1.0 %). The spiral scan at 120 kV with IQ20 and IQ80 yielded the lowest bias (mean value: 1.19 % and 1.23 %, respectively). CONCLUSION: Fat quantification using PCD-CT reconstructed at 70 keV was accurate and stable under various scan settings. PCD-CT has great potential for fat quantification using ultralow radiation doses.


Assuntos
Tecido Adiposo , Imagens de Fantasmas , Fótons , Tecido Adiposo/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação , Humanos
18.
Heliyon ; 10(13): e33647, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39055796

RESUMO

Carbendazim and acetamidine are pesticides that widely used to control pests and diseases in oilseed rape. In this paper, a rapid, accurate and reliable method was proposed for the detection of carbendazim and acetamidine with SERS microfluidic chip technology. Ag-ps(Polystyrene microspheres) microsphere SERS substrate was prepared by spin coating and magnetron sputtering deposition of Ag. The enhancement factor of prepared SERS substrate was 2.4 × 1010. The SERS detection working curves were well fitted and the linear parameters R2 were 0.987 and 0.994, respectively. The limit of detection was 0.01 mg/mL. The use of SERS microfluidic chip to detect carbendazim and acetamidine is expected to provide a way for the detection of pesticide residues in crops, which has broad application prospects in the field of food safety.

19.
PLoS One ; 19(2): e0297368, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38329980

RESUMO

Temporal expectation refers to the capacity to allocate resources at a particular point in time, enabling us to enhance our behavior performance. Empirical evidence indicates that, among younger adults, temporal expectation can be driven by rhythm (i.e., regular sequences of stimuli). However, whether there are age-related changes in rhythm-based temporal expectation has not been clearly established. Furthermore, whether tempo can influence the relationship between rhythm-based temporal expectation and aging remains unexplored. To address these questions, both younger and older participants took part in a rhythm-based temporal expectation task, engaging three distinct tempos: 600 ms (fast), 1800 ms (moderate), or 3000 ms (slow). The results demonstrated that temporal expectation effects (i.e., participants exhibited significantly faster responses during the regular trials compared to the irregular trials) were observed in both the younger and older participants under the moderate tempo condition. However, in the fast and slow tempo conditions, the temporal expectation effects were solely observed in the younger participants. These findings revealed that rhythm-based temporal expectations can be preserved during aging but within a specific tempo range. When the tempo falls within the range of either being too fast or too slow, it can manifest age-related declines in temporal expectations driven by rhythms.


Assuntos
Envelhecimento , Motivação , Fatores de Tempo , Adulto , Humanos
20.
J Thorac Imaging ; 39(4): 232-240, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38800956

RESUMO

OBJECTIVES: To investigate the predictive value of coronary computed tomography angiography-derived fractional flow reserve (CT-FFR) before percutaneous coronary intervention (PCI) to predict target vessel failure (TVF) after stent implantation. METHODS: This retrospective study included 429 patients (429 vessels) who underwent PCI and stent implantation after CCTA within 3 months. All patients underwent coronary stent implantation between January 2012 and December 2019. A dedicated workstation (Syngo Via, Siemens) was used to analyze and measure the CT-FFR value. The cut-off values of pre-PCI CT-FFR for predicting TVF were defined as 0.80 and the value using the log-rank maximization method, respectively. The primary outcome was TVF, defined as a composite of cardiac death, target vessel myocardial infarction, and clinically driven target vessel revascularization (TVR), which was a secondary outcome. RESULTS: During a median 64.0 months follow-up, the cumulative incidence of TVF was 7.9% (34/429). The cutoff value of pre-PCI CT-FFR based on the log-rank maximization method was 0.74, which was the independent predictor for TVF [hazard ratio (HR): 2.61 (95% CI: 1.13, 6.02); P =0.024] and TVR [HR: 3.63 (95%CI: 1.25, 10.51); P =0.018]. Compared with the clinical risk factor model, pre-PCI CT-FFR significantly improved the reclassification ability for TVF [net reclassification improvement (NRI), 0.424, P <0.001; integrative discrimination index (IDI), 0.011, P =0.022]. Adding stent information to the prediction model resulted in an improvement in reclassification for the TVF (C statistics: 0.711, P =0.001; NRI: 0.494, P <0.001; IDI: 0.020, P =0.028). CONCLUSIONS: Pre-PCI CT-FFR ≤0.74 was an independent predictor for TVF or TVR, and integration of clinical, pre-PCI CT-FFR, and stent information models can provide a better risk stratification model in patients with stent implantation.


Assuntos
Angiografia por Tomografia Computadorizada , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Valor Preditivo dos Testes , Stents , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Idoso , Angiografia por Tomografia Computadorizada/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa