Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
BMC Cardiovasc Disord ; 23(1): 457, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37710160

RESUMO

BACKGROUND: Intravascular ultrasound (IVUS) can provide detailed coronary anatomic parameters. The purpose of our study was to evaluate the parameters measured by IVUS for the prediction of intermediate coronary lesions function by referencing quantitative fraction ratio (QFR) ≤ 0.80 (vs. > 0.80). METHODS: Eighty four cases with 92 intermediate coronary lesions in vessels with a diameter ≥ 2.50 mm were enrolled. Paired assessment of IVUS and cQFR was available, and vessels with cQFR ≤ 0.8 were considered the positive reference standard. Logistic regression was used to select model variables by a maximum partial likelihood estimation test and receiver operating characteristic curve (ROC) analysis to evaluate the diagnostic value of different indices. RESULTS: Plaque burden (PB) and lesion length (LL) of IVUS were independent risk factors for the function of coronary lesions. The predictive probability P was derived from the combined PB and LL model. The area under the curve (AUC) of PB, (minimum lumen area) MLA, and LL and the predicted probability P are 0.789,0.732,0731, and 0.863, respectively (P < 0.01). The AUC of the predicted probability P was the biggest among them; the prediction accuracy of cQFR ≤ 0.8 was 84.8%, and the sensitivity of the diagnostic model was 0.826, specificity was 0. 725, and P < 0.01. CONCLUSION: PB and LL of IVUS were independent risk factors influencing the function of intermediate coronary lesions. The model combining the PB and LL may predict coronary artery function better than any other single parameter.


Assuntos
Vasos Coronários , Coração , Humanos , Vasos Coronários/diagnóstico por imagem , Ultrassonografia , Área Sob a Curva , Ultrassonografia de Intervenção
2.
Eur Neurol ; 85(1): 24-30, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34689144

RESUMO

BACKGROUND: Growing evidence suggests important effects of body mass index (BMI) and metabolic status on neurodegenerative diseases. However, the roles of BMI and metabolic status on cognitive outcomes in Parkinson's disease (PD) may vary and are yet to be determined. METHODS: In total, 139 PD patients from the whole PD cohort in Parkinson's Progression Markers Initiative database underwent complete laboratory measurements, demographic and anthropometric parameters at baseline, and were enrolled in this study. Further, they were categorized into 4 different BMI-metabolic status phenotypes using Adult Treatment Panel-III criteria. Motor and cognition scales at baseline and longitudinal changes after a 48-month follow-up were compared among the 4 groups. Repeated-measure linear mixed models were performed to compare PD-related biomarkers among BMI-metabolic status phenotypes across time. RESULTS: We found that PD patients in the metabolically unhealthy normal weight group showed more cognitive decline in global cognition and visuospatial perception after a 48-month follow-up than those in the other 3 groups (p < 0.05). No difference was found in motor scales among different BMI-metabolic status phenotypes. Finally, compared to the metabolically healthy normal weight group, the metabolically healthy obesity group had lower CSF Aß42 and serum neurofilament levels in repeated-measure linear mixed models adjusting for age, gender, APOE e4 carrier status, and years of education (p = 0.031 and 0.046, respectively). CONCLUSION: The MUNW phenotype was associated with a rapid cognitive decline in PD.


Assuntos
Disfunção Cognitiva , Doença de Parkinson , Biomarcadores , Índice de Massa Corporal , Disfunção Cognitiva/complicações , Progressão da Doença , Humanos , Doença de Parkinson/complicações , Doença de Parkinson/genética , Fenótipo
3.
Crit Care ; 24(1): 10, 2020 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-31918764

RESUMO

RATIONALE: The urinary proteome reflects molecular drivers of disease. OBJECTIVES: To construct a urinary proteomic biomarker predicting 1-year post-ICU mortality. METHODS: In 1243 patients, the urinary proteome was measured on ICU admission, using capillary electrophoresis coupled with mass spectrometry along with clinical variables, circulating biomarkers (BNP, hsTnT, active ADM, and NGAL), and urinary albumin. Methods included support vector modeling to construct the classifier, Cox regression, the integrated discrimination (IDI), and net reclassification (NRI) improvement, and area under the curve (AUC) to assess predictive accuracy, and Proteasix and protein-proteome interactome analyses. MEASUREMENTS AND MAIN RESULTS: In the discovery (deaths/survivors, 70/299) and test (175/699) datasets, the new classifier ACM128, mainly consisting of collagen fragments, yielding AUCs of 0.755 (95% CI, 0.708-0.798) and 0.688 (0.656-0.719), respectively. While accounting for study site and clinical risk factors, hazard ratios in 1243 patients were 2.41 (2.00-2.91) for ACM128 (+ 1 SD), 1.24 (1.16-1.32) for the Charlson Comorbidity Index (+ 1 point), and ≥ 1.19 (P ≤ 0.022) for other biomarkers (+ 1 SD). ACM128 improved (P ≤ 0.0001) IDI (≥ + 0.50), NRI (≥ + 53.7), and AUC (≥ + 0.037) over and beyond clinical risk indicators and other biomarkers. Interactome mapping, using parental proteins derived from sequenced peptides included in ACM128 and in silico predicted proteases, including/excluding urinary collagen fragments (63/35 peptides), revealed as top molecular pathways protein digestion and absorption, lysosomal activity, and apoptosis. CONCLUSIONS: The urinary proteomic classifier ACM128 predicts the 1-year post-ICU mortality over and beyond clinical risk factors and other biomarkers and revealed molecular pathways potentially contributing to a fatal outcome.


Assuntos
Biomarcadores/análise , Biomarcadores/urina , Mortalidade , Alta do Paciente/estatística & dados numéricos , Idoso , Análise de Variância , Área Sob a Curva , Feminino , Humanos , Unidades de Terapia Intensiva/organização & administração , Unidades de Terapia Intensiva/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Prognóstico , Modelos de Riscos Proporcionais , Curva ROC
4.
Blood Press ; 29(1): 39-46, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31352838

RESUMO

Purpose: Previous studies that addressed whether left ventricular hypertrophy is more closely associated with central than peripheral blood pressure (BP) have been inconsistent. Radial artery wave generated by applanation tonometry and calibrated with brachial BP in 162 adult Nigerians were analysed by using generalized transfer function to derive central BP.Materials and methods: We compared the associations of ECG voltages and left ventricular hypertrophy (ECG-LVH) as continuous and binary variables respectively with central and brachial BP indices.Results: In a multivariable adjusted analysis, 1 standard deviation (SD) increase in brachial systolic, diastolic, pulse and mean arterial pressures increased the Sokolow-Lyon QRS voltage by 0.34 (CI, 0.21-0.48; p < 0.0001), 0.21 (CI, 0.07-0.36; p < 0.05); 0.22 (CI, 0.9-0.34; p < 0.001) and 0.29 (CI, 0.14-0.43) similar to (p > 0.05) corresponding Sokolow-Lyon QRS increase of 0.26 (0.12-0.40, p < 0.001); 0.14 (0.00-0.28, p < 0.05); 0.24 (0.11-0.39; p < 0.001) and 0.19 (0.05-0.34, p < 0.05) respectively observed for 1 SD increment in central pressures. The odds ratio (OR) relating ECG-LVH to 1 SD increase in brachial systolic, pulse, and mean arterial pressures were 2.62 (CI, 1.49-4.65, p < 0.001); 1.88 (CI, 1.19-2.95, p < 0.01) and 2.16 (CI, 1.22-3.82, p < 0.01) was similar to (p > 0.05) corresponding OR of 2.41 (1.33-4.36, p < 0.01); 2.04 (1.23-3.37, p < 0.01); 2.00 (1.11-3.63, p < 0.001) observed for I SD increment in central pressures.Conclusion: Central and peripheral BP are similarly associated with Sokolow-Lyon ECG voltage and hypertrophy.


Assuntos
Pressão Sanguínea/fisiologia , Eletrocardiografia/métodos , Hipertrofia Ventricular Esquerda/fisiopatologia , Adulto , Idoso , Índice Tornozelo-Braço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nigéria
5.
Blood Press ; 29(3): 157-167, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31833420

RESUMO

Purpose: Arterial stiffness predicts cardiovascular complications. The association between arterial stiffness and blood lead (BL) remains poorly documented. We aimed to assess the association of central hemodynamic measurements, including pulse wave velocity (aPWV), with blood lead in a Flemish population.Materials and Methods: In this Flemish population study (mean age, 37.0 years; 48.3% women), 267 participants had their whole BL and 24-h urinary cadmium (UCd) measured by electrothermal atomic absorption spectrometry in 1985-2005. After 9.4 years (median), they underwent applanation tonometry to estimate central pulse pressure (cPP), the augmentation index (AI), pressure amplification (PA), and aPWV. The amplitudes of the forward (Pf) and backward (Pb) pulse waves and reflection index (RI) were derived by a pressure-based wave separation algorithm.Results: BL averaged 2.93 µg/dL (interquartile range, 1.80-4.70) and UCd 4.79 µg (2.91-7.85). Mean values were 45.0 ± 15.2 mm Hg for cPP, 24.4 ± 12.4% for AI, 1.34 ± 0.21 for PA, 7.65 ± 1.74 m/s for aPWV, 32.7 ± 9.9 mm Hg for Pf, 21.8 ± 8.4 mm Hg for Pb, and 66.9 ± 18.4% for RI. The multivariable-adjusted association sizes for a 2-fold higher BL were: +3.03% (95% confidence interval, 1.56, 4.50) for AI; -0.06 (-0.08, -0.04) for PA; 1.02 mm Hg (0.02, 2.02) for Pb; and 3.98% (1.71, 6.24) for RI (p ≤ .045). In 206 participants never on antihypertensive drug treatment, association sizes were +2.59 mm Hg (0.39, 4.79) for cPP and +0.26 m/s (0.03, 0.50) for aPWV. Analyses adjusted for co-exposure to cadmium were consistent.Conclusion: In conclusion, low-level environmental lead exposure possibly contributes to arterial stiffening and wave reflection from peripheral sites.


Assuntos
Exposição Ambiental/efeitos adversos , Poluentes Ambientais/efeitos adversos , Hemodinâmica/efeitos dos fármacos , Chumbo/efeitos adversos , Doenças Vasculares/induzido quimicamente , Rigidez Vascular/efeitos dos fármacos , Adolescente , Adulto , Bélgica , Poluentes Ambientais/sangue , Feminino , Humanos , Chumbo/sangue , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Doenças Vasculares/diagnóstico , Doenças Vasculares/fisiopatologia , Adulto Jovem
6.
Nephrol Dial Transplant ; 34(6): 941-946, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30165570

RESUMO

BACKGROUND: Numerous studies suggested that occupational or environmental exposure to lead adversely affects renal function. However, most studies lost relevance because of the substantially lower current environmental lead exposure and all relied on serum creatinine to estimate glomerular filtration. We investigated the association of estimated glomerular filtration rate (eGFR), estimated from serum creatinine, cystatin C or both, with blood lead (BPb) using the baseline measurements of the ongoing Study for Promotion of Health in Recycling Lead (SPHERL; NCT02243904) in newly hired workers prior to significant occupational lead exposure. METHODS: Among 447 men (participation rate, 82.7%), we assessed the association of eGFR and the urinary albumin-to-creatinine ratio (ACR) with BPb across thirds of the BPb distribution using linear regression analysis. Fully adjusted models accounted for age, blood pressure, body mass index, the waist-to-hip ratio, smoking, the total-to-high-density-lipoprotein ratio, plasma glucose, serum γ-glutamyltransferase and antihypertensive drug treatment. RESULTS: Age averaged 28.7 (SD, 10.2) years (range, 19.1-31.8). Geometric mean BPb concentration was 4.34 µg/dL (5th-95th percentile interval, 0.9-14.8). In unadjusted and adjusted analyses, eGFR estimated from serum creatinine [mean (SD), 105.26 (15.2) mL/min/1.73 m2], serum cystatin C [mean (SD), 127.8 (13.8) mL/min/1.73 m2] or both [mean (SD), 111.9 (14.8) mL/min/1.73 m2] was not associated with BPb (P ≥ 0.36), whereas ACR [geometric mean, 4.32 mg/g (5th-95th percentile interval, 1.91-12.50)] was lower with higher BPb. CONCLUSIONS: At the BPb levels observed in this study, there was no evidence for an association between renal function and lead exposure.


Assuntos
Exposição Ambiental/efeitos adversos , Rim/efeitos dos fármacos , Chumbo/efeitos adversos , Exposição Ocupacional/efeitos adversos , Adolescente , Adulto , Pressão Sanguínea , Determinação da Pressão Arterial , Creatinina/sangue , Cistatina C/sangue , Taxa de Filtração Glomerular , Humanos , Testes de Função Renal , Chumbo/sangue , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Fatores de Risco , Adulto Jovem
7.
Nephrol Dial Transplant ; 34(8): 1336-1343, 2019 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29982668

RESUMO

BACKGROUND: Chronic kidney disease (CKD) is common in patients after heart transplantation (HTx). We assessed whether in HTx recipients the proteomic urinary classifier CKD273 or sequenced urinary peptides revealing the parental proteins correlated with the estimated glomerular filtration rate (eGFR). METHODS: In 368 HTx patients, we measured the urinary peptidome and analysed CKD273 and 48 urinary peptides with a detectable signal in >95% of participants. After 9.1 months (median), eGFR and the urinary biomarkers were reassessed. RESULTS: In multivariable Bonferroni-corrected analyses of the baseline data, a 1-SD increase in CKD273 was associated with a 11.4 [95% confidence interval (CI) 7.25-15.5] mL/min/1.73 m2 lower eGFR and an odds ratio of 2.63 (1.56-4.46) for having eGFR <60 mL/min/1.73 m2. While relating eGFR category at follow-up to baseline urinary biomarkers, CKD273 had higher (P = 0.007) area under the curve (0.75; 95% CI 0.70-0.80) than 24-h proteinuria (0.64; 95% CI 0.58-0.69), but additional adjustment for baseline eGFR removed significance of both biomarkers. In partial least squares analysis, the strongest correlates of the multivariable-adjusted baseline eGFR were fragments of collagen I (positive) and the mucin-1 subunit α (inverse). Associations between the changes in eGFR and the urinary markers were inverse for CKD273 and mucin-1 and positive for urinary collagen I. CONCLUSIONS: With the exception of baseline eGFR, CKD273 was more closer associated with imminent renal dysfunction than 24-h proteinuria. Fragments of collagen I and mucin-1-respectively, positively and inversely associated with eGFR and change in eGFR-are single-peptide markers associated with renal dysfunction.


Assuntos
Cardiopatias/complicações , Cardiopatias/cirurgia , Transplante de Coração/efeitos adversos , Peptídeos/urina , Insuficiência Renal Crônica/complicações , Adulto , Idoso , Biomarcadores/urina , Colágeno Tipo I/urina , Feminino , Taxa de Filtração Glomerular , Cardiopatias/urina , Humanos , Testes de Função Renal , Análise dos Mínimos Quadrados , Masculino , Pessoa de Meia-Idade , Mucina-1/urina , Análise Multivariada , Proteômica , Insuficiência Renal Crônica/etiologia , Insuficiência Renal Crônica/urina , Sensibilidade e Especificidade
8.
BMC Cardiovasc Disord ; 19(1): 315, 2019 12 30.
Artigo em Inglês | MEDLINE | ID: mdl-31888510

RESUMO

BACKGROUND: Transesophageal echocardiography may be used to assess pulmonary veins for atrial fibrillation ablation. No study focused on the role of transthoracic echocardiography (TTE) in evaluating the diameter and anatomy of pulmonary veins. METHODS: Among 142 atrial fibrillation patients (57.7% men; mean age, 60.5) hospitalised for catheter ablation, we assessed pulmonary veins and compared the measurements by TTE with cardiac computed tomography (CT) before ablation. Among 17 patients who had follow-up examinations, the second measurements were also studied. RESULTS: TTE identified and determined the diameters of 140 (98.6%) right and 140 (98.6%) left superior PVs, and 136 (95.7%) right and 135 (95.1%) left inferior PVs. A separate middle PV ostia was identified in 14 out of the 22 patients (63.6%) for the right side and in 2 out of 4 (50.0%) for the left side. The PV diameters before ablation assessed by CT vs. TTE were 17.96 vs. 18.07 mm for right superior, 15.92 vs. 15.51 mm for right inferior, 18.54 vs. 18.42 mm for left superior, and 15.56 vs. 15.45 mm for left inferior vein. The paired differences between the assessments of CT and TTE were not significant (P ≥ 0.31) except for the right inferior vein with a CT-minus-TTE difference of 0.41 mm (P = 0.018). The follow-up PV diameters by both CT (P ≥ 0.069) and TTE (P ≥ 0.093) were not different from baseline measurements in the 17 patients who had follow-up measurements. CONCLUSIONS: With a better understanding of PV anatomy in TTE imaging, assessing PV diameters by non-invasive TTE is feasible. However, the clear identification of anatomic variation might still be challenging.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Ecocardiografia , Flebografia , Veias Pulmonares/diagnóstico por imagem , Idoso , Fibrilação Atrial/fisiopatologia , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/anormalidades , Veias Pulmonares/fisiopatologia , Reprodutibilidade dos Testes
9.
Occup Environ Med ; 76(6): 382-388, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30928907

RESUMO

OBJECTIVES: Previous studies relating nervous activity to blood lead (BL) levels have limited relevance, because over time environmental and occupational exposure substantially dropped. We investigated the association of heart rate variability (HRV) and median nerve conduction velocity (NCV) with BL using the baseline measurements collected in the Study for Promotion of Health in Recycling Lead (NCT02243904). METHODS: In 328 newly hired men (mean age 28.3 years; participation rate 82.7%), we derived HRV measures (power expressed in normalised units (nu) in the high-frequency (HF) and low-frequency (LF) domains, and LF/HF) prior to long-term occupational lead exposure. Five-minute ECG recordings, obtained in the supine and standing positions, were analysed by Fourier transform or autoregressive modelling, using Cardiax software. Motor NCV was measured at the median nerve by a handheld device (Brevio Nerve Conduction Monitoring System, NeuMed, West Trenton, NJ, USA). BL was determined by inductively coupled plasma mass spectrometry. RESULTS: Mean BL was 4.54 µg/dL (IQR 2.60-8.90 µg/dL). Mean supine and standing values of LF, HF and LF/HF were 50.5 and 21.1 nu and 2.63, and 59.7 and 10.9 nu and 6.31, respectively. Orthostatic stress decreased HF and increased LF (p<0.001). NCV averaged 3.74 m/s. Analyses across thirds of the BL distribution and multivariable-adjusted regression analyses failed to demonstrate any association of HRV or NCV with BL. CONCLUSIONS: At the exposure levels observed in our study, autonomous nervous activity and NCV were not associated with BL. TRIAL REGISTRATION NUMBER: NCT02243904.


Assuntos
Frequência Cardíaca/fisiologia , Chumbo/análise , Metalurgia/estatística & dados numéricos , Condução Nervosa/fisiologia , Adulto , Determinação da Pressão Arterial/métodos , Eletrocardiografia/métodos , Feminino , Humanos , Chumbo/sangue , Masculino , Nervos Periféricos/metabolismo , Nervos Periféricos/fisiologia
10.
Cardiovasc Ultrasound ; 17(1): 15, 2019 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-31382957

RESUMO

BACKGROUND: Previous studies highlighted the usefulness of integrating left ventricular (LV) deformation (strain) and hemodynamic parameters to quantify LV performance. In a population sample, we investigated the anthropometric and clinical determinants of a novel non-invasive index of LV systolic performance derived from simultaneous registration of LV strain and brachial pressure waveforms. METHODS: Three hundred fifty-six randomly recruited subjects (44.7% women; mean age, 53.9 years; 47.5% hypertensive) underwent echocardiographic and arterial data acquisition. We constructed pressure-strain loops from simultaneously recorded two-dimensional LV strain curves and brachial pressure waveforms obtained by finger applanation tonometry. We defined the area of this pressure-strain loop during ejection as LV ejection work density (EWD). We reported effect sizes as EWD changes associated with a 1-SD increase in covariables. RESULTS: In multivariable-adjusted analyses, higher EWD was associated with age, female sex and presence of hypertension (P ≤ 0.0084). In both men and women, EWD increased independently with augmentation pressure (effect size: + 59.1 Pa), central pulse pressure (+ 65.7 Pa) and pulse wave velocity (+ 44.8 Pa; P ≤ 0.0006). In men, EWD decreased with relative wall thickness (- 29.9 Pa) and increased with LV ejection fraction (+ 23.9 Pa; P ≤ 0.040). In women, EWD increased with left atrial (+ 76.2 Pa) and LV end-diastolic (+ 43.8 Pa) volume indexes and with E/e' ratio (+ 51.1 Pa; P ≤ 0.026). CONCLUSION: Older age, female sex and hypertension were associated with higher EWD. Integration of the LV pressure-strain loop during ejection might be a useful tool to non-invasively evaluate sex-specific and interdependent effects of preload and afterload on LV myocardial performance.


Assuntos
Pressão Sanguínea/fisiologia , Ecocardiografia Doppler/métodos , Ventrículos do Coração/diagnóstico por imagem , Hipertensão/fisiopatologia , Vigilância da População , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Diástole , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Hipertensão/diagnóstico , Masculino , Pessoa de Meia-Idade , Análise de Onda de Pulso , Estudos Retrospectivos , Sístole
11.
Blood Press ; 28(5): 279-290, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31075995

RESUMO

Background: Aortic pulse wave velocity (aPWV) predicts cardiovascular complications, but the association of central arterial properties with blood lead level (BL) is poorly documented. We therefore assessed their association with BL in 150 young men prior to occupational lead exposure, using baseline data of the Study for Promotion of Health in Recycling Lead (NCT02243904). Methods: Study nurses administered validated questionnaires and performed clinical measurements. Venous blood samples were obtained after 8-12 h of fasting. The radial, carotid and femoral pulse waves were tonometrically recorded. We accounted for ethnicity, age, anthropometric characteristics, mean arterial pressure, heart rate, smoking and drinking, and total and high-density lipoprotein serum cholesterol, as appropriate. Results: Mean values were 4.14 µg/dL for BL, 27 years for age, 108/79/28 mm Hg for central systolic/diastolic/pulse pressure, 100/10% for the augmentation ratio/index, 1.63 for pressure amplification, 5.94 m/s for aPWV, 27/11 mm Hg for the forward/backward pulse pressure height, and 43% for the reflection index. Per 10-fold BL increase, central diastolic pressure and the augmentation ratio were respectively 5.37 mm Hg (95% confidence interval [CI], 1.00-9.75) and 1.57 (CI, 0.20-2.94) greater, whereas central pulse pressure and the forward pulse pressure height were 3.74 mm Hg (CI, 0.60-6.88) and 3.37 mm Hg (CI, 0.22-6.53) smaller (p ≤ .036 for all). The other hemodynamic measurements were unrelated to BL. The reflected pulse peak time was inversely correlated with diastolic pressure (r = -0.20; p ≤ .017). Conclusion: At the exposure levels observed in our current study, aPWV, the gold standard to assess arterial stiffness, was not associated with BL. Increased peripheral arterial resistance, as reflected by higher diastolic pressure, might bring reflection points closer to the heart, thereby moving the backward wave into systole and increasing the augmentation ratio in relation to BL.


Assuntos
Hemodinâmica , Chumbo/sangue , Exposição Ocupacional , Adulto , Pressão Arterial , Pressão Sanguínea , Doença Crônica , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Onda de Pulso , Rigidez Vascular/fisiologia
12.
Echocardiography ; 36(3): 458-468, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30609050

RESUMO

BACKGROUND: Recent studies in patients and general population have reported the role of left ventricular (LV) longitudinal strain (LS) as an independent predictor of outcome. However, there are few data on changes in LS over time. We therefore investigated in a general population clinical correlates of temporal changes in LS. We also explored the potential correlation between temporal changes in LV volumes and LS. METHODS AND RESULTS: We measured LV end-systolic (ESV) and end-diastolic (EDV) volumes by conventional echocardiography and LS by 2D speckle tracking in 627 participants (mean age 50.6 years, 51.4% women; 41.3% hypertensives) at baseline and after 4.7 years. For statistical analysis, we used the absolute values of LS. In stepwise regression, the magnitude of the decrease in all LV LS indexes over time was greater in men than in women (P < 0.0001). Higher baseline mean arterial pressure (MAP), a larger longitudinal increase in MAP, and stopping diuretic treatment during follow-up were related to larger decreases in LS indexes. In multivariable-adjusted analysis, we observed an inverse correlation between baseline ESV and LV LS (P ≤ 0.0017). Similarly, lower baseline LS and a larger decrease in LS over time were correlated with a lesser longitudinal decrease in ESV (P ≤ 0.0004). CONCLUSIONS: A significant decrease in LS over time was associated with male sex, higher baseline MAP, ∆MAP, and alteration in antihypertensive treatment. We suggested an interaction between a longitudinal decrease in LV deformation and adverse cardiac remodeling, while underscoring the importance of deformation analysis based on LS assessment in patients at risk.


Assuntos
Ecocardiografia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação Ventricular , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tempo
13.
JAMA ; 322(5): 409-420, 2019 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-31386134

RESUMO

Importance: Blood pressure (BP) is a known risk factor for overall mortality and cardiovascular (CV)-specific fatal and nonfatal outcomes. It is uncertain which BP index is most strongly associated with these outcomes. Objective: To evaluate the association of BP indexes with death and a composite CV event. Design, Setting, and Participants: Longitudinal population-based cohort study of 11 135 adults from Europe, Asia, and South America with baseline observations collected from May 1988 to May 2010 (last follow-ups, August 2006-October 2016). Exposures: Blood pressure measured by an observer or an automated office machine; measured for 24 hours, during the day or the night; and the dipping ratio (nighttime divided by daytime readings). Main Outcomes and Measures: Multivariable-adjusted hazard ratios (HRs) expressed the risk of death or a CV event associated with BP increments of 20/10 mm Hg. Cardiovascular events included CV mortality combined with nonfatal coronary events, heart failure, and stroke. Improvement in model performance was assessed by the change in the area under the curve (AUC). Results: Among 11 135 participants (median age, 54.7 years, 49.3% women), 2836 participants died (18.5 per 1000 person-years) and 2049 (13.4 per 1000 person-years) experienced a CV event over a median of 13.8 years of follow-up. Both end points were significantly associated with all single systolic BP indexes (P < .001). For nighttime systolic BP level, the HR for total mortality was 1.23 (95% CI, 1.17-1.28) and for CV events, 1.36 (95% CI, 1.30-1.43). For the 24-hour systolic BP level, the HR for total mortality was 1.22 (95% CI, 1.16-1.28) and for CV events, 1.45 (95% CI, 1.37-1.54). With adjustment for any of the other systolic BP indexes, the associations of nighttime and 24-hour systolic BP with the primary outcomes remained statistically significant (HRs ranging from 1.17 [95% CI, 1.10-1.25] to 1.87 [95% CI, 1.62-2.16]). Base models that included single systolic BP indexes yielded an AUC of 0.83 for mortality and 0.84 for the CV outcomes. Adding 24-hour or nighttime systolic BP to base models that included other BP indexes resulted in incremental improvements in the AUC of 0.0013 to 0.0027 for mortality and 0.0031 to 0.0075 for the composite CV outcome. Adding any systolic BP index to models already including nighttime or 24-hour systolic BP did not significantly improve model performance. These findings were consistent for diastolic BP. Conclusions and Relevance: In this population-based cohort study, higher 24-hour and nighttime blood pressure measurements were significantly associated with greater risks of death and a composite CV outcome, even after adjusting for other office-based or ambulatory blood pressure measurements. Thus, 24-hour and nighttime blood pressure may be considered optimal measurements for estimating CV risk, although statistically, model improvement compared with other blood pressure indexes was small.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Doenças Cardiovasculares/epidemiologia , Hipertensão/complicações , Adulto , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Doenças Cardiovasculares/etiologia , Ritmo Circadiano , Feminino , Humanos , Hipertensão/diagnóstico , Hipertensão/mortalidade , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Fatores de Risco
14.
Nephrol Dial Transplant ; 33(3): 426-435, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28992257

RESUMO

Background: Inflammation is a hallmark of chronic kidney disease (CKD) and stimulates glomerular expression of vascular adhesion molecules (VCAMs). We investigated in a general population whether estimated glomerular filtration rate (eGFR) is associated with circulating adhesion molecules, inflammation markers or both. Methods: We measured serum levels of five adhesion molecules [VCAM-1, intracellular adhesion molecule-1 (ICAM-1), P-selectin, E-selectin and monocyte chemoattractant protein-1 (MCP-1)] and seven inflammation markers [C-reactive protein (CRP), neutrophil gelatinase-associated lipocalin (NGAL), tumour necrosis factor receptor 1 (TNF-R1), TNF-α, interleukin 6 (IL-6), IL-8 and vascular endothelial growth factor] in 1338 randomly recruited people (50.8% women, mean age 51.7 years, eGFR 79.9 mL/min/1.73 m2). Results: In multivariable-adjusted analyses, eGFR decreased (P ≤ 0.004) with higher VCAM-1 (association size expressed in mL/min/1.73 m2 for a doubling of the marker, -2.99), MCP-1 (-1.19), NGAL (-1.19), TNF receptor 1 (-2.78), TNF-α (-2.28) and IL-6 (-0.94). The odds ratios of having eGFR <60 versus ≥60 mL/min/1.73 m2 (n = 138 versus 1200) were significant (P ≤ 0.001) for VCAM-1 (1.77), MCP-1 (1.32), NGAL (1.26), TNF-R1 (1.49), TNF-α (1.45) and IL-6 (1.20). Compared with 24-h albuminuria, VCAM-1 increased (P <0.0001) the area under the curve from 0.57 to 0.65, MCP-1 to 0.67 and TNF-R1 to 0.79, but TNF-R1 outperformed both adhesion molecules (P < 0.0001). Conclusions: In a general population, eGFR is inversely associated with circulating adhesion molecules VCAM-1 and MCP-1 and several inflammation markers, but inflammation markers, in particular TNF-R1 and TNF-α, identify patients with eGFR <60 mL/min/1.73 m2 more accurately.


Assuntos
Biomarcadores/sangue , Moléculas de Adesão Celular/sangue , Taxa de Filtração Glomerular , Mediadores da Inflamação/sangue , Inflamação/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bélgica/epidemiologia , Estudos Transversais , Feminino , Seguimentos , Humanos , Inflamação/sangue , Inflamação/epidemiologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Prognóstico , Adulto Jovem
15.
Nephrol Dial Transplant ; 33(7): 1122-1128, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-28992263

RESUMO

Background: Recent studies showing an inverse association between estimated glomerular filtration rate (eGFR), a microvascular trait, and inactive desphospho-uncarboxylated matrix Gla protein (dp-ucMGP) support the hypothesis that after vitamin K-dependent activation, matrix Gla protein (MGP) is renoprotective, but these were limited by their cross-sectional design. Methods: In 1009 randomly recruited Flemish (50.6% women), we assessed the association between eGFR and plasma dp-ucMGP, using multivariable-adjusted analyses. Results: From baseline to follow-up 8.9 years later (median), dp-ucMGP increased by 23.0% whereas eGFR decreased by 4.05 mL/min/1.73 m2 (P < 0.001). In 938 participants with baseline eGFR ≥60 mL/min/1.73 m2, the incidence of eGFR <60 mL/min/1.73 m2 at follow-up was 8.0% versus 4.1% in the top versus the bottom halve of baseline dp-ucMGP. For a 5-fold higher plasma dp-ucMGP at baseline, eGFR at follow-up decreased by 3.15 mL/min/1.73 m2 [95% confidence interval (CI) 1.26-5.05; P = 0.001]. The hazard ratio expressing the risk of progression to eGFR <60 mL/min/1.73 m2 was 3.49 (95% CI 1.45-8.40; P = 0.005). The hazard ratio relating the presence of microalbuminuria at follow-up to baseline dp-ucMGP was 4.70 (95% CI 1.57-14.1; P = 0.006). Conclusions: In conclusion, circulating inactive dp-ucMGP, a biomarker of poor vitamin K status, predicts renal dysfunction. Possible underlying mechanisms include protection by activated MGP against calcification and inhibition of the bone morphogenetic protein-signalling pathway.


Assuntos
Albuminúria/sangue , Calcinose/sangue , Proteínas de Ligação ao Cálcio/sangue , Proteínas da Matriz Extracelular/sangue , Taxa de Filtração Glomerular/fisiologia , Biomarcadores/sangue , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Proteína de Matriz Gla
16.
Nephrol Dial Transplant ; 33(3): 514-522, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28340119

RESUMO

Background: Vitamin K (VK)-dependent γ-glutamate carboxylation and serine phosphorylation activate matrix Gla protein (MGP) to a potent locally acting inhibitor of calcification. Nephrolithiasis represents a process of unwanted calcification associated with substantial mortality and high recurrence rates. We hypothesized that the risk of nephrolithiasis increases with VK shortage, as exemplified by higher plasma levels of desphospho-uncarboxylated MGP (dp-ucMGP). Methods: In 1748 randomly recruited Flemish individuals (51.1% women; mean age 46.8 years), we determined dp-ucMGP and the prevalence of nephrolithiasis at baseline (April 1996-February 2015) and its incidence during follow-up until March 2016. We estimated the multivariable-adjusted relative risk associated with the doubling of dp-ucMGP, using logistic or Cox regression. We did a Mendelian randomization analysis using four MGP genotypes as instrumental variables. Results: With adjustments applied for sex, age and 24-h urinary volume and calcium excretion, the odds of having prevalent nephrolithiasis [n = 144 (8.2%)] associated with dp-ucMGP was 1.31 [95% confidence interval (CI) 1.04-1.64; P = 0.022]. dp-ucMGP levels were associated (P ≤ 0.001) with MGP variants rs2098435, rs4236 and rs2430692. In the Mendelian analysis, the causal odds ratio was 3.82 (95% CI 1.15-12.7; P = 0.029). The incidence of nephrolithiasis over 12.0 years (median) was 37 cases (0.2%). With similar adjustments as before, the hazard ratio in relation to dp-ucMGP was 2.48 (95% CI 1.71-3.61; P < 0.001). Additional adjustment for a nephrolithiasis propensity score produced consistent results. Conclusion: Higher levels of inactive dp-ucMGP may be causally associated with the risk of nephrolithiasis. Whether or not VK deficiency plays a role in these observations remains to be firmly established.


Assuntos
Biomarcadores/sangue , Proteínas de Ligação ao Cálcio/sangue , Proteínas da Matriz Extracelular/sangue , Análise da Randomização Mendeliana , Nefrolitíase/sangue , Nefrolitíase/etiologia , Deficiência de Vitamina K/complicações , Vitamina K/metabolismo , Adulto , Bélgica/epidemiologia , Proteínas de Ligação ao Cálcio/genética , Proteínas da Matriz Extracelular/genética , Feminino , Genótipo , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Nefrolitíase/epidemiologia , Fosforilação , Prognóstico , Adulto Jovem , Proteína de Matriz Gla
17.
Environ Health ; 17(1): 16, 2018 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-29458375

RESUMO

A significant association of office diastolic blood pressure with low-level blood lead exposure was reported in a Brazilian adult population. However, caution should be taken to interpret these results. The multivariable-adjusted association with blood pressure was positive for diastolic blood pressure, but inverse for systolic blood pressure. The association sizes were infinitesimal without clinical relevance. The outcome measures, i.e. blood pressure and the prevalence of hypertension were analysed across categories of the blood lead distribution - not in relation to blood lead as continuous variable. Blood pressure was the average of two oscillometric office readings, whereas ambulatory monitoring is the state-of-the-art.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Pressão Sanguínea , Brasil , Humanos , Hipertensão , Chumbo
19.
Blood Press ; 27(6): 341-350, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29909698

RESUMO

BACKGROUND: Guidelines on the required number of ambulatory blood pressure (ABP) readings focus on individual patients. Clinical researchers often face the dilemma of applying recommendations and discarding potentially valuable information or accepting fewer readings. METHODS: Starting from ABP recordings with ≥30/≥10 awake/asleep readings in 4277 participants enrolled in eight population studies in the International Database on Ambulatory Blood Pressure in Relation to Cardiovascular Outcomes (IDACO), we randomly selected a certain number of readings (from 30 to 1 awake and 10 to 1 asleep readings) at a time over 1000 bootstraps at each step. We evaluated: (i) concordance of the ABP level; (ii) consistency of the cross-classification based on office blood pressure and ABP; and (iii) accuracy in predicting cardiovascular complications. For each criterion, we fitted a regression line joining data points relating outcome to the number of readings covering the ranges of 30-20/10-7 for awake/asleep readings. RESULTS: Reducing readings widened the SD of the systolic/diastolic differences between full (reference) and selected recordings from 1.7/1.2 (30 readings) to 14.3/10.3 mm Hg (single reading) during wakefulness, and from 1.9/1.4 to 10.3/7.7 mm Hg during sleep; lowered the κ statistic from 0.94 to 0.63, and decreased the hazard ratio associated with 10/5 mm Hg increments in systolic/diastolic ABP from 1.21/1.14 to 1.06/1.04 during wakefulness and from 1.26/1.17 to 1.14/1.08 during sleep. The first data points falling off these regression lines during wakefulness/sleep corresponded to 8/3 and 8/4 readings for criteria (i) and (iii) and to 5 awake readings for criterion (ii). CONCLUSIONS: 24-h ambulatory recordings with ≥8/≥4 awake/asleep readings yielded ABP levels similar to recordings including the guideline-recommended ≥20/≥7 readings. These criteria save valuable data in a research setting, but are not applicable to clinical practice.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Pressão Sanguínea , Bases de Dados Factuais , Sono , Vigília , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto
20.
BMC Med Genet ; 18(1): 45, 2017 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-28449647

RESUMO

BACKGROUND: Platelet Endothelial Aggregation Receptor 1 (PEAR1), a membrane protein highly expressed in platelets and endothelial cells, plays a role in platelet contact-induced activation, sustained platelet aggregation and endothelial function. Previous reports implicate PEAR1 rs12041331 as a variant influencing risk in patients with coronary heart disease. We investigated whether genetic variation in PEAR1 predicts cardiovascular outcome in a white population. METHODS: In 1938 participants enrolled in the Flemish Study on Environment, Genes and Health Outcomes (51.3% women; mean age 43.6 years), we genotyped 9 tagging SNPs in PEAR1, measured baseline cardiovascular risk factors, and recorded Cardiovascular disease incidence. For SNPs, we contrasted cardiovascular disease incidence of minor-allele heterozygotes and homozygotes (variant) vs. major-allele homozygotes (reference) and for haplotypes carriers vs. non-carriers. In adjusted analyses, we accounted for family clusters and baseline covariables, including sex, age, body mass index, mean arterial pressure, the total-to-HDL cholesterol ratio, smoking and drinking, antihypertensive drug treatment, and history of cardiovascular disease and diabetes mellitus. RESULTS: Over a median follow-up of 15.3 years, 238 died and 181 experienced a major cardiovascular endpoint. The multivariable-adjusted hazard ratios of eight PEAR1 SNPs, including rs12566888, ranged from 0.87 to 1.07 (P ≥0.35) and from 0.78 to 1.30 (P ≥0.15), respectively. The hazard ratios of three haplotypes with frequency ≥10% ranged from 0.93 to 1.11 (P ≥0.49) for mortality and from 0.84 to 1.03 (P ≥0.29) for a cardiovascular complications. These results were not influenced by intake of antiplatelet drugs, nonsteroidal anti-inflammatory drugs, or both (P-values for interaction ≥ 0.056). CONCLUSIONS: In a White population, we could not replicate previous reports from experimental studies or obtained in patients suggesting that PEAR1 might be a susceptibility gene for cardiovascular complications.


Assuntos
Doenças Cardiovasculares/genética , Predisposição Genética para Doença , Receptores de Superfície Celular/genética , Adulto , Bélgica , Feminino , Haplótipos , Humanos , Masculino , Pessoa de Meia-Idade , Polimorfismo de Nucleotídeo Único
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa