Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Int Ophthalmol ; 44(1): 292, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940969

RESUMO

PURPOSE: Compared to Shack-Hartmann wavefront sensor (SHWS), the parameters of virtual SHWS (vSHWS) can be easily adjusted to obtain the optimal performance of aberration measurement. Its current optimal parameters are obtained with only a set of statistical aberrations and not statistically significant. Whether the above parameters are consistent with the statistical results of the optimal parameters corresponding to each set of aberrations, and which performance is better if not? The purpose of this study was to answer these questions. METHODS: The optimal parameters to reconstruct 624 sets of clinical ocular aberrations in the highest accuracy, including the numbers of sub-apertures (NSAs) and the expansion ratios (ERs) of electric field zero-padding, were determined sequentially in this work. By using wavefront-reconstruction accuracy as an evaluation index, the statistical optimal parameter configuration was selected from some possible configurations determined by the optimal NSAs and ERs. RESULTS: The statistical optimal parameters are consistent for normal and abnormal eyes. They are different from the optimal parameters obtained with a set of statistical aberrations from the same 624 sets of aberrations, and the performance using the former is better than that using the latter. The performance using a fixed set of statistical optimal parameters is even close to that using the respective optimal parameters corresponding to each set of aberrations. CONCLUSION: The vSHWS configured with a fixed set of statistical optimal parameters can be used for high-precision aberration measurement of both normal and abnormal eyes. The statistical optimal parameters are more suitable for vSHWS than the parameters obtained with a set of statistical aberrations. These conclusions are significant for the designs of vSHWS and also SHWS.


Assuntos
Aberrações de Frente de Onda da Córnea , Humanos , Aberrações de Frente de Onda da Córnea/diagnóstico , Aberrações de Frente de Onda da Córnea/fisiopatologia , Topografia da Córnea/métodos , Aberrometria/métodos , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
2.
Sensors (Basel) ; 21(14)2021 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-34300438

RESUMO

Virtual Shack-Hartmann wavefront sensing (vSHWS) can flexibly adjust parameters to meet different requirements without changing the system, and it is a promising means for aberration measurement. However, how to optimize its parameters to achieve the best performance is rarely discussed. In this work, the data processing procedure and methods of vSHWS were demonstrated by using a set of normal human ocular aberrations as an example. The shapes (round and square) of a virtual lenslet, the zero-padding of the sub-aperture electric field, sub-aperture number, as well as the sequences (before and after diffraction calculation), algorithms, and interval of data interpolation, were analyzed to find the optimal configuration. The effect of the above optimizations on its anti-noise performance was also studied. The Zernike coefficient errors and the root mean square of the wavefront error between the reconstructed and preset wavefronts were used for performance evaluation. The performance of the optimized vSHWS could be significantly improved compared to that of a non-optimized one, which was also verified with 20 sets of clinical human ocular aberrations. This work makes the vSHWS's implementation clearer, and the optimization methods and the obtained results are of great significance for its applications.


Assuntos
Algoritmos , Olho , Face , Humanos , Rotação
3.
Opt Express ; 19(9): 7960-70, 2011 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-21643045

RESUMO

We demonstrated an optical fiber delivered coherent anti-Stokes Raman scattering (CARS) microscopy imaging system with a polarization-based mechanism for suppression of four-wave mixing (FWM) signals in delivery fiber. Polarization maintaining fibers (PMF) were used as the delivery fiber to ensure stability of the state of polarization (SOP) of lasers. The pump and Stokes waves were coupled into PMFs at orthogonal SOPs along the slow and fast axes of PMFs, respectively, resulting in a significant reduction of FWM signals generated in the fiber. At the output end of PMFs, a dual-wavelength waveplate was used to realign the SOPs of the two waves into identical SOPs prior to their entrance into the CARS microscope. Therefore, it allows the pump and Stokes waves with identical SOPs to excite samples at highest excitation efficiency. Our experimental results showed that this polarization-based FWM-suppressing mechanism can dramatically reduce FWM signals generated in PMFs up to approximately 99%. Meanwhile, the PMF-delivered CARS microscopy system with this mechanism can still produce high-quality CARS images. Consequently, our PMF-delivered CARS microscopy imaging system with the polarization-based FWM-suppressing mechanism potentially offers a new strategy for building fiber-based CARS endoscopes with effective suppression of FWM background noises.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Aumento da Imagem/instrumentação , Microscopia/instrumentação , Análise Espectral Raman/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Espalhamento de Radiação
4.
Opt Express ; 18(12): 13017-28, 2010 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-20588430

RESUMO

We investigated the possibility of using standard commercial multimode fibers (MMF), Corning SMF28 fibers, to deliver picosecond excitation lasers for coherent anti-Stokes Raman scattering (CARS) imaging. We theoretically and/or experimentally analyzed issues associated with the fiber delivery, such as dispersion length, walk-off length, nonlinear length, average threshold power for self-phase modulations, and four-wave mixing (FWM). These analyses can also be applied to other types of fibers. We found that FWM signals are generated in MMF, but they can be filtered out using a long-pass filter for CARS imaging. Finally, we demonstrated that MMF can be used for delivery of picosecond excitation lasers in the CARS imaging system without any degradation of image quality.


Assuntos
Lasers , Fibras Ópticas , Análise Espectral Raman/instrumentação , Análise Espectral Raman/métodos , Animais , Simulação por Computador , Orelha/anatomia & histologia , Rim/anatomia & histologia , Camundongos , Fatores de Tempo
5.
Nanoscale Res Lett ; 8(1): 497, 2013 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-24261454

RESUMO

In this letter, a double active layer (Zr:SiOx/C:SiOx) resistive switching memory device with outstanding performance is presented. Through current fitting, hopping conduction mechanism is found in both high-resistance state (HRS) and low-resistance state (LRS) of double active layer RRAM devices. By analyzing Raman and FTIR spectra, we observed that graphene oxide exists in C:SiOx layer. Compared with single Zr:SiOx layer structure, Zr:SiOx/C:SiOx structure has superior performance, including low operating current, improved uniformity in both set and reset processes, and satisfactory endurance characteristics, all of which are attributed to the double-layer structure and the existence of graphene oxide flakes formed by the sputter process.

6.
Biomed Opt Express ; 2(8): 2160-74, 2011 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-21833355

RESUMO

We present a label-free, chemically-selective, quantitative imaging strategy to identify breast cancer and differentiate its subtypes using coherent anti-Stokes Raman scattering (CARS) microscopy. Human normal breast tissue, benign proliferative, as well as in situ and invasive carcinomas, were imaged ex vivo. Simply by visualizing cellular and tissue features appearing on CARS images, cancerous lesions can be readily separated from normal tissue and benign proliferative lesion. To further distinguish cancer subtypes, quantitative disease-related features, describing the geometry and distribution of cancer cell nuclei, were extracted and applied to a computerized classification system. The results show that in situ carcinoma was successfully distinguished from invasive carcinoma, while invasive ductal carcinoma (IDC) and invasive lobular carcinoma were also distinguished from each other. Furthermore, 80% of intermediate-grade IDC and 85% of high-grade IDC were correctly distinguished from each other. The proposed quantitative CARS imaging method has the potential to enable rapid diagnosis of breast cancer.

7.
Biomed Opt Express ; 2(4): 915-26, 2011 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-21483613

RESUMO

A custom built coherent anti-Stokes Raman scattering (CARS) microscope was used to image prostatic glands and nerve structures from 17 patients undergoing radical prostatectomy. Imaging of glandular and nerve structures showed distinctive cellular features that correlated to histological stains. Segmentation of cell nucleus was performed to establish a cell feature-based model to separate normal glands from cancer glands. In this study, we use a single parameter, average cell neighbor distance based on CARS imaging, to characterize normal and cancerous glandular structures. By combining CARS with our novel classification model, we are able to characterize prostate glandular and nerve structures in a manner that potentially enables real-time, intra-operative assessment of surgical margins and neurovascular bundles. As such, this method could potentially improve outcomes following radical prostatectomy.

8.
J Biomed Opt ; 16(9): 096004, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21950918

RESUMO

We report the development and application of a knowledge-based coherent anti-Stokes Raman scattering (CARS) microscopy system for label-free imaging, pattern recognition, and classification of cells and tissue structures for differentiating lung cancer from non-neoplastic lung tissues and identifying lung cancer subtypes. A total of 1014 CARS images were acquired from 92 fresh frozen lung tissue samples. The established pathological workup and diagnostic cellular were used as prior knowledge for establishment of a knowledge-based CARS system using a machine learning approach. This system functions to separate normal, non-neoplastic, and subtypes of lung cancer tissues based on extracted quantitative features describing fibrils and cell morphology. The knowledge-based CARS system showed the ability to distinguish lung cancer from normal and non-neoplastic lung tissue with 91% sensitivity and 92% specificity. Small cell carcinomas were distinguished from nonsmall cell carcinomas with 100% sensitivity and specificity. As an adjunct to submitting tissue samples to routine pathology, our novel system recognizes the patterns of fibril and cell morphology, enabling medical practitioners to perform differential diagnosis of lung lesions in mere minutes. The demonstration of the strategy is also a necessary step toward in vivo point-of-care diagnosis of precancerous and cancerous lung lesions with a fiber-based CARS microendoscope.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/classificação , Neoplasias Pulmonares/diagnóstico , Análise Espectral Raman/métodos , Máquina de Vetores de Suporte , Adenocarcinoma/química , Adenocarcinoma/classificação , Adenocarcinoma/diagnóstico , Adenocarcinoma de Pulmão , Carcinoma Pulmonar de Células não Pequenas/química , Carcinoma Pulmonar de Células não Pequenas/classificação , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma de Células Escamosas/química , Carcinoma de Células Escamosas/classificação , Carcinoma de Células Escamosas/diagnóstico , Bases de Dados Factuais , Diagnóstico Diferencial , Histocitoquímica , Humanos , Processamento de Imagem Assistida por Computador/métodos , Análise dos Mínimos Quadrados , Neoplasias Pulmonares/química , Pneumonia , Sensibilidade e Especificidade , Carcinoma de Pequenas Células do Pulmão/química , Carcinoma de Pequenas Células do Pulmão/classificação , Carcinoma de Pequenas Células do Pulmão/diagnóstico
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa