Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Anal Chem ; 95(50): 18335-18343, 2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-38064273

RESUMO

Capillary-assisted flow is valuable for utilizing microfluidics-based electrical sensing platforms at on-site locations by simplifying microfluidic operations and system construction; however, incorporating capillary-assisted flow in platforms requires easy microfluidic modification and stability over time for capillary-assisted flow generation and sensing performance. Herein, we report a capillary-assisted microfluidics-based electrical sensing platform using a one-step modification of polydimethylsiloxane (PDMS) with polyethylene glycol (PEG). As a model of electrical sensing platforms, this work focused on resistive pulse sensing (RPS) using a micropore in a microfluidic chip for label-free electrical detection of single analytes, and filling the micropore with an electrolyte is the first step to perform this RPS. The PEG-PDMS surfaces remained hydrophilic after ambient storage for 30 d and assisted in generating an electrolyte flow for filling the micropore with the electrolyte. We demonstrated the successful detection and size analysis of micrometer particles and bacterial cells based on RPS using the microfluidic chip stored in a dry state for 30 d. Combining this capillary-assisted microfluidic platform with a portable RPS system makes on-site detection and analysis of single pathogens possible.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Desenho de Equipamento , Dimetilpolisiloxanos , Eletrólitos
2.
Anal Chem ; 93(18): 7037-7044, 2021 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-33908760

RESUMO

A rapid and simple cancer detection method independent of cancer type is an important technology for cancer diagnosis. Although the expression profiles of biological molecules contained in cancer cell-derived extracellular vesicles (EVs) are considered candidates for discrimination indexes to identify any cancerous cells in the body, it takes a certain amount of time to examine these expression profiles. Here, we report the shape distributions of EVs suspended in a solution and the potential of these distributions as a discrimination index to discriminate cancer cells. Distribution analysis is achieved by low-aspect-ratio nanopore devices that enable us to rapidly analyze EV shapes individually in solution, and the present results reveal a dependence of EV shape distribution on the type of cells (cultured liver, breast, and colorectal cancer cells and cultured normal breast cells) secreting EVs. The findings in this study provide realizability and experimental basis for a simple method to discriminate several types of cancerous cells based on rapid analyses of EV shape distributions.


Assuntos
Vesículas Extracelulares , Neoplasias , Linhagem Celular , Células Cultivadas , Humanos
3.
Nanotechnology ; 32(25)2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33725670

RESUMO

Detection of cell-free DNA (cfDNA) has an impact on DNA analysis in liquid biopsies. However, current strategies to detect cfDNA have limitations that should be overcome, such as having low sensitivity and requiring much time and a specialized instrument. Thus, non-invasive and rapid detection tools are needed for disease prevention and early-stage treatment. Here we developed a device having a microheater integrated with zinc oxide nanowires (microheater-ZnO-NWs) to detect target single-stranded DNAs (ssDNAs) based on DNA probe hybridization. We confirmed experimentally that our device realizedin-situannealed DNA probes by which we subsequently detected target ssDNAs. We envision that this device can be utilized for fundamental studies related to nanobiodevice-based DNA detection.


Assuntos
Técnicas Biossensoriais , Ácidos Nucleicos Livres/análise , DNA de Cadeia Simples/análise , Dispositivos Lab-On-A-Chip , Nanofios/química , Óxido de Zinco/química , Sondas de DNA/química , Humanos , Limite de Detecção , Biópsia Líquida/métodos , Hibridização de Ácido Nucleico/métodos
4.
Nano Lett ; 20(1): 599-605, 2020 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-31858802

RESUMO

We demonstrate the facile, rational synthesis of monodispersedly sized zinc oxide (ZnO) nanowires from randomly sized seeds by hydrothermal growth. Uniformly shaped nanowire tips constructed in ammonia-dominated alkaline conditions serve as a foundation for the subsequent formation of the monodisperse nanowires. By precisely controlling the sharp tip formation and the nucleation, our method substantially narrows the distribution of ZnO nanowire diameters from σ = 13.5 nm down to σ = 1.3 nm and controls their diameter by a completely bottom-up method, even initiating from randomly sized seeds. The proposed concept of sharp tip based monodisperse nanowires growth can be applied to the growth of diverse metal oxide nanowires and thus paves the way for bottom-up grown metal oxide nanowires-integrated nanodevices with a reliable performance.

5.
Anal Chem ; 92(3): 2483-2491, 2020 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-31922717

RESUMO

The detection of circulating tumor cells (CTCs) from liquid biopsies using microfluidic devices is attracting a considerable amount of attention as a new, less-invasive cancer diagnostic and prognostic method. One of the drawbacks of the existing antibody-based detection systems is the false negatives for epithelial cell adhesion molecule detection of CTCs. Here we report a mechanical low-pass filtering technique based on a microfluidic constriction and electrical current sensing system for the novel CTC detection in whole blood without any specific antigen-antibody interaction or biochemical modification of the cell surface. The mechanical response of model cells of CTCs, such as HeLa, A549, and MDA-MB-231 cells, clearly demonstrated different behaviors from that of Jurkat cells, a human T-lymphocyte cell line, when they passed through the 6-µm wide constriction channel. A 6-µm wide constriction channel was determined as the optimum size to identify CTCs in whole blood with an accuracy greater than 95% in tens of milliseconds. The mechanical filtering of cells at a single cell level was achieved from whole blood without any pretreatment (e.g., dilution of lysing) and prelabeling (e.g., fluorophores or antibodies).


Assuntos
Técnicas Analíticas Microfluídicas , Células Neoplásicas Circulantes/patologia , Células A549 , Molécula de Adesão da Célula Epitelial/análise , Células HeLa , Humanos , Células Tumorais Cultivadas
6.
Nano Lett ; 19(4): 2443-2449, 2019 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-30888179

RESUMO

Metal-oxide nanowires have demonstrated excellent capability in the electrical detection of various molecules based on their material robustness in liquid and air environments. Although the surface structure of the nanowires essentially determines their interaction with adsorbed molecules, understanding the correlation between an oxide nanowire surface and an adsorbed molecule is still a major challenge. Herein, we propose a rational methodology to obtain this information for low-density molecules adsorbed on metal oxide nanowire surfaces by employing infrared p-polarized multiple-angle incidence resolution spectroscopy and temperature-programmed desorption/gas chromatography-mass spectrometry. As a model system, we studied the surface chemical transformation of an aldehyde (nonanal, a cancer biomarker in breath) on single-crystalline ZnO nanowires. We found that a slight surface reconstruction, induced by the thermal pretreatment, determines the surface chemical reactivity of nonanal. The present results show that the observed surface reaction trend can be interpreted in terms of the density of Zn ions exposed on the nanowire surface and of their corresponding spatial arrangement on the surface, which promotes the reaction between neighboring adsorbed molecules. The proposed methodology will support a better understanding of complex molecular transformations on various nanostructured metal-oxide surfaces.

7.
Anal Chem ; 91(10): 6514-6521, 2019 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-31035752

RESUMO

Micro- and nanopillar chips are widely used to separate and enrich biomolecules, such as DNA, RNA, protein, and cells, as an analytical technique and to provide a confined nanospace for polymer science analyses. Herein, we demonstrated a continuous accurate and precise separation technique for extracellular vesicles (EVs), nanometer-sized vesicles (typically 50-200 nm) currently recognized as novel biomarkers present in biofluids, based on the principle of electroosmotic flow-driven deterministic lateral displacement in micro- and nanopillar array chips. Notably, the easy-to-operate flow control afforded by electroosmotic flow allowed nanoparticles 50-500 nm in size, including EVs, to be precisely separated and enriched in a continuous manner. By observation of the flow behavior of nanoparticles, we found that electroosmotic flow velocity in the nanopillar arrays did not solely depend on counterion mobility on the surface of nanopillar chips, but rather showed a parabolic flow profile. This hydrodynamic pressure-free and easy-to-use separation and enrichment technique, which requires only electrode insertion into the reservoirs and electric field application, may thus serve as a promising technique for future precise and accurate EV analysis, reflecting both size and composition for research and potential clinical diagnostic applications.


Assuntos
Vesículas Extracelulares/química , Dispositivos Lab-On-A-Chip , Fluorescência , Nanoestruturas , Poliestirenos
8.
Anal Chem ; 91(20): 12890-12899, 2019 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-31442026

RESUMO

The mechanical properties of a cell, which include parameters such as elasticity, inner pressure, and tensile strength, are extremely important because changes in these properties are indicative of diseases ranging from diabetes to malignant transformation. Considering the heterogeneity within a population of cancer cells, a robust measurement system at the single cell level is required for research and in clinical purposes. In this study, a potential microfluidic device for high-throughput and practical mechanotyping were developed to investigate the deformability and sizes of cells through a single run. This mechanotyping device consisted of two different sizes of consecutive constrictions in a microchannel and measured the size of cells and related deformability during transit. Cell deformability was evaluated based on the transit and on the effects of cytoskeleton-affecting drugs, which were detected within 50 ms. The mechanotyping device was able to also measure a cell cycle without the use of fluorescent or protein tags.


Assuntos
Forma Celular , Citoesqueleto/patologia , Técnicas Analíticas Microfluídicas/métodos , Neoplasias/patologia , Análise de Célula Única/métodos , Antineoplásicos/farmacologia , Fenômenos Biomecânicos , Ciclo Celular , Citoesqueleto/efeitos dos fármacos , Elasticidade , Eletricidade , Fricção , Células HeLa , Humanos , Células Jurkat , Técnicas Analíticas Microfluídicas/instrumentação
9.
J Am Chem Soc ; 139(40): 14137-14142, 2017 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-28880545

RESUMO

Measuring ionic currents passing through nano- or micropores has shown great promise for the electrical discrimination of various biomolecules, cells, bacteria, and viruses. However, conventional measurements have shown there is an inherent limitation to the detectable particle volume (1% of the pore volume), which critically hinders applications to real mixtures of biomolecule samples with a wide size range of suspended particles. Here we propose a rational methodology that can detect samples with the detectable particle volume of 0.01% of the pore volume by measuring a transient current generated from the potential differences in a microfluidic bridge circuit. Our method substantially suppresses the background ionic current from the µA level to the pA level, which essentially lowers the detectable particle volume limit even for relatively large pore structures. Indeed, utilizing a microscale long pore structure (volume of 5.6 × 104 aL; height and width of 2.0 × 2.0 µm; length of 14 µm), we successfully detected various samples including polystyrene nanoparticles (volume: 4 aL), bacteria, cancer cells, and DNA molecules. Our method will expand the applicability of ionic current sensing systems for various mixed biomolecule samples with a wide size range, which have been difficult to measure by previously existing pore technologies.

10.
Sci Technol Adv Mater ; 17(1): 644-649, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27877910

RESUMO

DNA methylation is a stable epigenetic modification, which is well known to be involved in gene expression regulation. In general, however, analyzing DNA methylation requires rather time consuming processes (24-96 h) via DNA replication and protein modification. Here we demonstrate a methodology to analyze DNA methylation at a single DNA molecule level without any protein modifications by measuring the contracted length and relaxation time of DNA within a nanochannel. Our methodology is based on the fact that methylation makes DNA molecules stiffer, resulting in a longer contracted length and a longer relaxation time (a slower contraction rate). The present methodology offers a promising way to identify DNA methylation without any protein modification at a single DNA molecule level within 2 h.

11.
Nano Lett ; 15(5): 3445-51, 2015 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-25879141

RESUMO

Exploiting the nonequilibrium transport of macromolecules makes it possible to increase the separation speed without any loss of separation resolution. Here we report the arrangement of a nanostructure array in microchannels to control equilibrium and nonequilibrium transports of macromolecules. The direct observation and separation of macromolecules in the nanopillar array reported here are the first to reveal the nonequilibrium transport, which has a potential to overcome the intrinsic trade-off between the separation speed and resolution.

12.
J Extracell Biol ; 3(6): e160, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38947173

RESUMO

Congenital diaphragmatic hernia (CDH) is a life-threatening condition with high morbidity and mortality rates. The survival rate of neonates with severe CDH is reportedly only 10%-15%. However, prenatal prediction of severe cases is difficult, and the discovery of new predictive markers is an urgent issue. In this study, we focused on microRNAs (miRNAs) in amniotic fluid-derived small EVs (AF-sEVs). We identified four miRNAs (hsa-miR-127-3p, hsa-miR-363-3p, hsa-miR-493-5p, and hsa-miR-615-3p) with AUC > 0.8 to classify good prognosis group and poor prognosis group in human study. The AUC for hsa-miR-127-3p and hsa-miR-615-3p, for predicting the poor prognosis, were 0.93 and 0.91, respectively. In addition, in the in vivo study, the miRNA profiles of the lung tissues of CDH rats were different from those of control rats. Additionally, two elevated miRNAs (rno-miR-215-5p and rno-miR-148a-3p) in the lung tissues of CDH rats were increased in the AF-sEVs of CDH rats. Our results suggest that severe CDH neonates can be predicted prenatally with high accuracy using miRNAs contained in AF-sEVs. Furthermore, miRNA profile changes in AF-sEVs reflected the lung status in CDH. Our findings may contribute to the development of advanced perinatal care for patients with CDH.

13.
Biosens Bioelectron ; 254: 116218, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38518559

RESUMO

Biodetection for non-invasive diagnostics of fluids, especially urine, remains a challenge to scientists due to low target concentrations. And biological complexes of the detection target may contain contaminants that also interfere with any assay. Dengue non-structural 1 protein (Dengue NS1) is an important biomarker for dengue hemorrhagic fever and dengue shock syndrome. Here, we developed an Au-decorated nanowire platform and applied it with a sandwich fluorophore-linked immunosorbent well plate assay (FLISA) to detect Dengue NS1 in urine. For the platform, we fabricated zinc oxide (ZnO) nanowires to provide a high surface area and then coated them with gold nanoparticles (ZnO/Au nanowires) to simply modify the Dengue NS1 antibody and enhance the fluorescence intensity. Our platform employs a sandwich FLISA that exhibits high sensitivity, specifically detecting Dengue NS1 with a limit of detection (LOD) of 1.35 pg/mL. This LOD was 4500-fold lower than the LOD of a commercially available kit for Dengue NS1 enzyme-linked immunosorbent assay. We believe that our ZnO/Au nanowire platform has the potential to revolutionize the field of non-invasive diagnostics for dengue.


Assuntos
Técnicas Biossensoriais , Vírus da Dengue , Dengue , Nanopartículas Metálicas , Nanofios , Óxido de Zinco , Humanos , Dengue/diagnóstico , Ouro , Sensibilidade e Especificidade , Proteínas não Estruturais Virais , Antígenos Virais , Ensaio de Imunoadsorção Enzimática , Imunoadsorventes , Anticorpos Antivirais
14.
ACS Appl Mater Interfaces ; 16(23): 29570-29580, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38804616

RESUMO

Extracellular vesicles (EVs) contain a subset of proteins, lipids, and nucleic acids that maintain the characteristics of the parent cell. Immunotherapy using EVs has become a focus of research due to their unique features and bioinspired applications in cancer treatment. Unlike conventional immunotherapy using tumor fragments, EVs can be easily obtained from bodily fluids without invasive actions. We previously fabricated nanowire devices that were specialized for EV collection, but they were not suitable for cell culturing. In this study, we fabricated a ZnO/Al2O3 core-shell nanowire platform that could collect more than 60% of the EVs from the cell supernatant. Additionally, we could continue to culture dendritic cells (DCs) on the platform as an artificial lymph node to investigate cell maturation into antigen-presenting cells. Finally, using this platform, we reproduced a series of on-site immune processes that are among the pivotal immune functions of DCs and include such processes as antigen uptake, antigen presentation, and endocytosis of cancer-derived EVs. This platform provides a new ex vivo tool for EV-DC-mediated immunotherapies.


Assuntos
Células Dendríticas , Vesículas Extracelulares , Nanofios , Neoplasias , Células Dendríticas/imunologia , Células Dendríticas/metabolismo , Nanofios/química , Vesículas Extracelulares/química , Humanos , Neoplasias/terapia , Neoplasias/patologia , Neoplasias/imunologia , Imunoterapia , Óxido de Zinco/química , Animais , Linhagem Celular Tumoral , Camundongos
15.
Phys Chem Chem Phys ; 15(25): 10316-20, 2013 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-23698569

RESUMO

We demonstrate a dark-field microscopic technique for real-time monitoring of DNA metallization. The growth of silver nanoparticles on DNA molecules was observed using plasmon resonance light scattering in the presence of a weak catalyst triggering photo-reduction of Ag(+). This simple strategy could facilitate the controlled fabrication of DNA-templated nanoelectronic devices.


Assuntos
DNA/química , Nanopartículas Metálicas/química , Prata/química , Eletrônica , Oxirredução , Ressonância de Plasmônio de Superfície
16.
ACS Appl Mater Interfaces ; 15(30): 36866-36876, 2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37486017

RESUMO

A low-temperature Al2O3 deposition process provides a simplified method to form a conductive two-dimensional electron gas (2DEG) at the metal oxide/Al2O3 heterointerface. However, the impact of key factors of the interface defects and cation interdiffusion on the interface is still not well understood. Furthermore, there is still a blank space in terms of applications that go beyond the understanding of the interface's electrical conductivity. In this work, we carried out a systematic experimental study by oxygen plasma pretreatment and thermal annealing post-treatment to study the impact of interface defects and cation interdiffusion at the In2O3/Al2O3 interface on the electrical conductance, respectively. Combining the trends in electrical conductance with the structural characteristics, we found that building a sharp interface with a high concentration of interface defects provides a reliable approach to producing such a conductive interface. After applying this conductive interface as electrodes for fabricating a field-effect transistor (FET) device, we found that this interface electrode exhibited ultrastability in phosphate-buffered saline (PBS), a commonly used biological saline solution. This study provides new insights into the formation of conductive 2DEGs at metal oxide/Al2O3 interfaces and lays the foundation for further applications as electrodes in bioelectronic devices.

17.
ACS Nano ; 17(3): 2235-2244, 2023 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-36655866

RESUMO

Extracellular vesicles (EVs) have promising potential as biomarkers for early cancer diagnosis. The EVs have been widely studied as biological cargo containing essential biological information not only from inside vesicles such as nucleic acids and proteins but also from outside vesicles such as membrane proteins and glycolipids. Although various methods have been developed to isolate EVs with high yields such as captures based on density, size, and immunoaffinity, different measurement systems are needed to analyze EVs after isolation, and a platform that enables all-in-one analysis of EVs from capture to detection in multiple samples is desired. Since a nanowire-based approach has shown an effective capability for capturing EVs via surface charge interaction compared to other conventional methods, here, we upgraded the conventional well plate assay to an all-in-one nanowire-integrated well plate assay system (i.e., a nanowire assay system) that enables charge-based EV capture and EV analysis of membrane proteins. We applied the nanowire assay system to analyze EVs from brain tumor organoids in which tumor environments, including vascular formations, were reconstructed, and we found that the membrane protein expression ratio of CD31/CD63 was 1.42-fold higher in the tumor organoid-derived EVs with a p-value less than 0.05. Furthermore, this ratio for urine samples from glioblastoma patients was 2.25-fold higher than that from noncancer subjects with a p-value less than 0.05 as well. Our results demonstrated that the conventional well plate method integrated with the nanowire-based EV capture approach allows users not only to capture EVs effectively but also to analyze them in one assay system. We anticipate that the all-in-one nanowire assay system will be a powerful tool for elucidating EV-mediated tumor-microenvironment crosstalk.


Assuntos
Neoplasias Encefálicas , Vesículas Extracelulares , Nanofios , Humanos , Vesículas Extracelulares/metabolismo , Biomarcadores/metabolismo , Neoplasias Encefálicas/diagnóstico , Proteínas de Membrana/metabolismo , Microambiente Tumoral
18.
Nanomaterials (Basel) ; 13(21)2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37947691

RESUMO

Rapid and sensitive detection of Dengue virus remains a critical challenge in global public health. This study presents the development and evaluation of a Zinc Oxide nanorod (ZnO NR)-surface-integrated microfluidic platform for the early detection of Dengue virus. Utilizing a seed-assisted hydrothermal synthesis method, high-purity ZnO NRs were synthesized, characterized by their hexagonal wurtzite structure and a high surface-to-volume ratio, offering abundant binding sites for bioconjugation. Further, a comparative analysis demonstrated that the ZnO NR substrate outperformed traditional bare glass substrates in functionalization efficiency with 4G2 monoclonal antibody (mAb). Subsequent optimization of the functionalization process identified 4% (3-Glycidyloxypropyl)trimethoxysilane (GPTMS) as the most effective surface modifier. The integration of this substrate within a herringbone-structured microfluidic platform resulted in a robust device for immunofluorescence detection of DENV-3. The limit of detection (LOD) for DENV-3 was observed to be as low as 3.1 × 10-4 ng/mL, highlighting the remarkable sensitivity of the ZnO NR-integrated microfluidic device. This study emphasizes the potential of ZnO NRs and the developed microfluidic platform for the early detection of DENV-3, with possible expansion to other biological targets, hence paving the way for enhanced public health responses and improved disease management strategies.

19.
Nat Commun ; 14(1): 6915, 2023 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-37938557

RESUMO

Extracellular vesicles (EVs), including exosomes, are recognized as promising functional targets involved in disease mechanisms. However, the intravital heterogeneity of EVs remains unclear, and the general limitation for analyzing EVs is the need for a certain volume of biofluids. Here, we present cellulose nanofiber (CNF) sheets to resolve these issues. We show that CNF sheets capture and preserve EVs from ~10 µL of biofluid and enable the analysis of bioactive molecules inside EVs. By attaching CNF sheets to moistened organs, we collect EVs in trace amounts of ascites, which is sufficient to perform small RNA sequence analyses. In an ovarian cancer mouse model, we demonstrate that CNF sheets enable the detection of cancer-associated miRNAs from the very early phase when mice did not have apparent ascites, and that EVs from different locations have unique miRNA profiles. By performing CNF sheet analyses in patients, we identify further location-based differences in EV miRNA profiles, with profiles reflecting disease conditions. We conduct spatial exosome analyses using CNF sheets to reveal that ascites EVs from cancer patients exhibit location-dependent heterogeneity. This technique could provide insights into EV biology and suggests a clinical strategy contributing to cancer diagnosis, staging evaluation, and therapy planning.


Assuntos
Exossomos , Vesículas Extracelulares , MicroRNAs , Nanofibras , Neoplasias Ovarianas , Humanos , Animais , Camundongos , Feminino , Exossomos/genética , Ascite , MicroRNAs/genética , Celulose , Neoplasias Ovarianas/genética
20.
Biosens Bioelectron ; 234: 115318, 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37172361

RESUMO

Cell-free DNA (cfDNA) and extracellular vesicles (EVs) are molecular biomarkers in liquid biopsies that can be applied for cancer detection, which are known to carry information on the necessary conditions for oncogenesis and cancer cell-specific activities after oncogenesis, respectively. Analyses for both cfDNA and EVs from the same body fluid can provide insights into screening and identifying the molecular subtypes of cancer; however, a major bottleneck is the lack of efficient and standardized techniques for the isolation of cfDNA and EVs from clinical specimens. Here, we achieved catch-and-release isolation by hydrogen bond-mediated binding of cfDNA in urine to zinc oxide (ZnO) nanowires, which also capture EVs by surface charge, and subsequently we identified genetic mutations in urinary cfDNA. The binding strength of hydrogen bonds between single-crystal ZnO nanowires and DNA was found to be equal to or larger than that of conventional hydrophobic interactions, suggesting the possibility of isolating trace amounts of cfDNA. Our results demonstrated that nanowire-based cancer screening assay can screen cancer and can identify the molecular subtypes of cancer in urine from brain tumor patients through EV analysis and cfDNA mutation analysis. We anticipate our method to be a starting point for more sophisticated diagnostic models of cancer screening and identification.


Assuntos
Técnicas Biossensoriais , Ácidos Nucleicos Livres , Vesículas Extracelulares , Neoplasias , Óxido de Zinco , Humanos , Biópsia Líquida/métodos , Neoplasias/metabolismo , Vesículas Extracelulares/química , Mutação , Carcinogênese/metabolismo , Biomarcadores Tumorais/análise
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa