Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Zhonghua Yan Ke Za Zhi ; 59(10): 838-845, 2023 Oct 11.
Artigo em Zh | MEDLINE | ID: mdl-37648680

RESUMO

Objective: To investigate the clinical presentation pattern of acute primary angle-closure glaucoma (PACG) during the 2019 novel coronavirus (2019-nCoV) pandemic over the past three years, and its relationship with 2019-nCoV infections of Omicron variants in Guangdong province. Methods: Ecological study.Patients who were newly diagnosed with acute PACG from February 2020 to January 2023 at the Zhongshan Ophthalmic Center of Sun Yat-sen University were included in the study, and their basic information was collected. Patients were divided into the 2020 group (diagnosed between February 1st, 2020 and January 31st 2021), the 2021 group (diagnosed between February 1st, 2021 and January 31st 2022), and the 2022 group (diagnosed between February 1st, 2022 and January 31st 2023). The clinical presentation pattern of newly diagnosed acute PACG was observed and compared between groups. The daily number of newly diagnosed 2019-nCoV infections in Guangdong province was obtained from the Chinese Center for Disease Control and Prevention. The correlation between the daily number of newly diagnosed acute PACG and that of newly diagnosed 2019-nCoV infections during the epidemic period of Omicron variants between December 2022 and January 2023 was assessed. Results: The study included 1 048 patients with newly diagnosed acute PACG, with 235 for the 2020 group, 274 for the 2021 group, and 539 for the 2022 group. Our results showed that the average weekly number of newly diagnosed acute PACG patients in 2022 [8 (5, 11)] was significantly larger than that in 2020 (4.52±1.95, P<0.05) and 2021 (5.27±2.76, P<0.05). The average weekly number increased to 22.11±20.84 between December 2022 and January 2023. The total number of newly diagnosed acute PACG patients during this period was 199, which was 36.9% (199/539) of the total number of the same year and was 6.63 and 6.42 times as many as that in the same period (December and January) of 2020 and 2021. The proportion of patients with bilateral eye involvement during this period in 2022 was significantly higher than that in 2020 and 2021 (P<0.05). Further analysis found that 88.6% (109/123) of cases had a history of 2019-nCoV infection 2 (0, 3) days before the onset of acute PACG symptoms in average. The estimated daily number of acute PACG onset increased rapidly, peaked on December 23th, 2022, and then dropped gradually. This trend was similar to that of the daily number of new 2019-nCoV infections in Guangdong province. Changes of the daily number of new 2019-nCoV infections in Guangdong province had a positive correlation with the estimated daily number of acute PACG onset (r=0.84, P<0.001). Conclusion: A dramatic increase in the clinical presentation of acute PACG was observed at Zhongshan Ophthalmic Center between December 2022 and January 2023, which was the epidemic period of Omicron variants. There is a correlation between the trend of the estimated daily number of acute PACG onset and that of new 2019-nCoV infections of Omicron variants in Guangdong province, but the exact reason remains to be further studied. (This article was published ahead of print on the official website of Chinese Journal of Ophthalmology on August 31, 2023).

2.
Opt Express ; 20(8): 8228-39, 2012 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-22513535

RESUMO

A systematic investigation has been carried out to study the influence of various annealings and implantations on the photoluminescence (PL) properties of phosphorus (P)-implanted Ge epitaxial films on Si substrate. For un-capped Ge samples, rapid thermal annealing (RTA) at 700 °C for 300 seconds yields the strongest PL emission peaked at 1550 nm. The influence of employing various capping layers (i.e., SiO(2), Si(3)N(4), and α-Si ) on the PL properties has been investigated. The capping layers are found to effectively decrease the dopant loss, leading to a significant PL enhancement. Si(3)N(4) is found to be the most efficient capping layer to prevent dopant out-diffusion and thus lead to strongest PL. Furthermore, it has been found that capping layers not only enhance the PL intensities but also make PL emission peak red- and blue- shift, depending on the stress type of the capping films. The effect of implantation dose on the PL has been also investigated.

3.
Diabet Med ; 29(11): e417-24, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22375612

RESUMO

AIMS: To test the hypothesis that glycaemic control achieved when switching sitagliptin to exenatide twice daily plus metformin is non-inferior to adding exenatide twice daily to sitagliptin and metformin. METHODS: Patients with Type 2 diabetes inadequately controlled with sitagliptin plus metformin were randomly assigned to 20 weeks of treatment with twice-daily exenatide plus placebo and metformin (SWITCH, n = 127) or twice-daily exenatide plus sitagliptin and metformin (ADD, n = 128). RESULTS: Non-inferiority (0.4% margin) of SWITCH to ADD treatment, measured by change in HbA(1c) from baseline to week 20, was not shown {between-treatment difference in least-squares mean [95% CI 3 mmol/mol (0.30%)] [0.8-5.8 (0.07-0.53)]}. A greater reduction (P = 0.012) in HbA(1c) [least-squares mean (se)] was experienced by patients in the ADD group {-7 mmol/mol [-0.68%] [0.9 (0.08)]}, compared with those in the SWITCH group {-4 mmol/mol [-0.38%] [1.0 (0.09)]} and a greater proportion (P = 0.027) of patients in the ADD group (41.7%) reached < 7.0% (< 53 mmol/mol) HbA(1c) target, compared with those in the SWITCH group (26.6%) by week 20. Patients in the ADD group experienced greater fasting serum glucose (P = 0.038) and daily mean postprandial self-monitored blood glucose (P = 0.048) reductions, compared with patients in the SWITCH group, by week 20. Patients in both groups experienced a lower incidence of nausea and vomiting compared with previous exenatide studies. CONCLUSIONS: Non-inferiority of SWITCH to ADD treatment was not supported by the results of this study. In patients with Type 2 diabetes inadequately controlled with sitagliptin plus metformin, adding exenatide provided better glycaemic control than switching to exenatide. These results are consistent with the clinical approach that adding is better than switching to another oral anti-hyperglycaemic medication.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Inibidores da Dipeptidil Peptidase IV/administração & dosagem , Hipoglicemiantes/administração & dosagem , Metformina/administração & dosagem , Peptídeos/administração & dosagem , Pirazinas/administração & dosagem , Triazóis/administração & dosagem , Peçonhas/administração & dosagem , Adolescente , Adulto , Idoso , Argentina/epidemiologia , Austrália/epidemiologia , Glicemia/metabolismo , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/epidemiologia , Inibidores da Dipeptidil Peptidase IV/farmacologia , Método Duplo-Cego , Esquema de Medicação , Exenatida , Feminino , Alemanha/epidemiologia , Hemoglobinas Glicadas/metabolismo , Grécia/epidemiologia , Humanos , Hipoglicemia/sangue , Hipoglicemia/epidemiologia , Hipoglicemiantes/farmacologia , Índia/epidemiologia , Masculino , Metformina/farmacologia , México/epidemiologia , Pessoa de Meia-Idade , Peptídeos/farmacologia , Pirazinas/farmacologia , República da Coreia/epidemiologia , Fosfato de Sitagliptina , Resultado do Tratamento , Triazóis/farmacologia , Peçonhas/farmacologia
4.
Opt Express ; 19(3): 2729-38, 2011 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-21369094

RESUMO

Laterally electrically-pumped Si light-emitting diodes (LEDs) based on truncated nanocrystalline-Si (nc-Si)/SiO2 quantum wells are fabricated with complementary-metal-semiconductor-oxide (CMOS) process. Visible electroluminescence (EL) can be observed under a reverse bias larger than ~6 V. The light emission would probably originate from the spontaneous hot-carrier relaxations within the conduction and the valance bands when the device is sufficiently reverse-biased. The EL spectral profile is found to be modulated by varying structure parameters of the interdigitated finger electrodes. Up to ~20 times EL intensity enhancement is achieved as compared to vertical-current-injection LED prepared using the same material system. Based on the lateral-current-injection scheme, a Si/SiO2 MQW LED with Fabry-Perot (FP) microcavity and an on-chip waveguided LED that emits at 1.55-µm are proposed.


Assuntos
Iluminação/instrumentação , Nanoestruturas/química , Nanotecnologia/instrumentação , Semicondutores , Dióxido de Silício/química , Campos Eletromagnéticos , Desenho de Equipamento , Análise de Falha de Equipamento , Nanoestruturas/ultraestrutura
5.
Opt Express ; 19(25): 25206-21, 2011 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-22273912

RESUMO

We report on the evolution of modes in cylindrical metal/dielectric systems. The transition between surface plasmon polaritons and localized modes is documented in terms of the real and imaginary parts of the effective refractive index as a function of geometric and optical parameters. We show the evolution process of SPP and localized modes. New phenomena of coupling between SPP and core-like modes, and of mode gap and super-long surface plasmon polaritons are found and discussed. We conclude that both superluminal light and slow light can be solutions of metallically coated dielectric fibers.


Assuntos
Nanopartículas Metálicas/química , Modelos Químicos , Ressonância de Plasmônio de Superfície/métodos , Simulação por Computador , Luz , Espalhamento de Radiação
6.
Opt Express ; 19(12): 11220-7, 2011 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-21716351

RESUMO

In this work, we design and demonstrate planar ridge microdisk resonators in silicon-on-insulator, which assemble the advantages of microring and microdisk resonators. The dependences of resonator optical modes on the slab thickness and the waveguide-to-resonator coupling gap are investigated. The highest Q-factor obtained is ~4 × 10(5). Using the thermo-optical effect, we attain a resonance wavelength tuning efficiency of ~66.5 pm/mW. We also compare the transmission spectra measured by using wavelength-scanning method and voltage-scanning method and show potential application for the adopted voltage-scanning method.

7.
Opt Express ; 18(2): 393-400, 2010 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-20173859

RESUMO

We propose a relay ring resonator structure which comprises multiple cascaded microring resonators, in which the drop waveguide of a microring resonator is also the input waveguide of the subsequent microring resonator, and so forth. Thus, the transmission response of the relay ring resonator structure has sharp peaks, high out-of-band rejection ratios, and long group delays. A relay ring resonator structure comprising 90 microrings is fabricated on silicon nitride wire waveguides. The simulation and experimental results are in good agreement.


Assuntos
Modelos Teóricos , Dispositivos Ópticos , Refratometria/instrumentação , Transdutores , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento
8.
Opt Express ; 17(23): 20891-9, 2009 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-19997326

RESUMO

Polycrystalline silicon (polySi) wire waveguides with width ranging from 200 to 500 nm are fabricated by solid-phase crystallization (SPC) of deposited amorphous silicon (a-Si) on SiO(2) at a maximum temperature of 1000 degrees C. The propagation loss at 1550 nm decreases from 13.0 to 9.8 dB/cm with the waveguide width shrinking from 500 to 300 nm while the 200-nm-wide waveguides exhibit quite large loss (>70 dB/cm) mainly due to the relatively rough sidewall of waveguides induced by the polySi dry etch. By modifying the process sequence, i.e., first patterning the a-Si layer into waveguides by dry etch and then SPC, the sidewall roughness is significantly improved but the polySi crystallinity is degraded, leading to 13.9 dB/cm loss in the 200-nm-wide waveguides while larger losses in the wider waveguides. Phosphorus implantation causes an additional loss in the polySi waveguides. The doping-induced optical loss increases relatively slowly with the phosphorus concentration increasing up to 1 x 10(18) cm(-3), whereas the 5 x 10(18) cm(-3) doped waveguides exhibit large loss due to the dominant free carrier absorption. For all undoped polySi waveguides, further 1-2 dB/cm loss reduction is obtained by a standard forming gas (10%H(2) + 90%N(2)) annealing owing to the hydrogen passivation of Si dangling bonds present in polySi waveguides, achieving the lowest loss of 7.9 dB/cm in the 300-nm-wide polySi waveguides. However, for the phosphorus doped polySi waveguides, the propagation loss is slightly increased by the forming gas annealing.


Assuntos
Nanotecnologia/métodos , Nanofios/química , Óptica e Fotônica , Silício/química , Cristalização , Desenho de Equipamento , Nanopartículas Metálicas/química , Metais/química , Microscopia Eletrônica de Varredura/métodos , Ressonância de Plasmônio de Superfície
9.
Opt Express ; 16(25): 20803-8, 2008 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-19065218

RESUMO

A double-tip coupler that comprises two inversely and laterally tapered waveguides is experimentally demonstrated for efficient light coupling between a fiber and a sub-micron silicon nitride waveguide. The coupling efficiency of the fabricated double-tip coupler can be improved by as much as over 2 dB per coupling facet, compared with that of a single-tip one with the same tip width of 180 nm. The effect of the gap width of the double tips on the coupling efficiency is studied both in experiment and simulation.


Assuntos
Desenho Assistido por Computador , Modelos Teóricos , Fibras Ópticas , Simulação por Computador , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Espalhamento de Radiação
10.
Opt Express ; 16(20): 15304-11, 2008 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-18825166

RESUMO

We designed and fabricated silicon-on-insulator based Michelson interferometer (MI) thermo-optical switches with deep etched trenches for heat-isolation. Switch power was reduced approximately 20% for the switch with deep etched trenches, and the MI saved approximately 50% power than that of the Mach-Zehnder interferometer. 10.6 mW switch power, approximately 42 micros switch time for the MI with deep trenches, 13.14 mW switch power and approximately 34 micros switch time for the MI without deep trenches were achieved.


Assuntos
Temperatura Alta , Interferometria/instrumentação , Interferometria/métodos , Óptica e Fotônica , Desenho de Equipamento , Microscopia Eletrônica de Varredura , Temperatura
11.
Opt Express ; 16(9): 6425-32, 2008 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-18545346

RESUMO

In this communication, the sub-micron size polycrystalline silicon (poly- Si) single mode waveguides are fabricated and integrated with SiON waveguide coupler by deep UV lithography. The propagation loss of poly-Si waveguide and coupling loss with optical flat polarization-maintaining fiber (PMF) are measured. For whole C-band (i.e., lambda approximately 1520-1565nm), the propagation loss of TE mode is measured to approximately 6.45+/-0.3dB/cm. The coupling loss with optical flat PMF is approximately 3.4dB/facet for TE mode. To the best of our knowledge, the propagation loss is among the best reported results. This communication discusses the factors reducing the propagation loss, especially the effect of the refractive index contrast. Compared to the SiO(2) cladding, poly-Si waveguide with SiON cladding exhibits lower propagation loss.


Assuntos
Óptica e Fotônica/instrumentação , Silício/química , Simulação por Computador , Cristalografia , Luz , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Refratometria , Espalhamento de Radiação , Fatores de Tempo
12.
Opt Express ; 16(11): 7849-59, 2008 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-18545495

RESUMO

A Ring-resonator Mach-Zehnder interferometer (RR-MZI) optical interleaver structure comprising a ring resonator (RR) and a 3 dB directional coupler is proposed. The interleaver is fabricated with 300 nm x 300 nm silicon wires on silicon-on-insulator (SOI) wafers. The fabricated interleaver demonstrates a flat-top spectral response, and the measured free spectral range (FSR) is approximately 20 nm. The insertion loss (IL) of the device is approximately -10 dB and the polarization dependent loss (PDL) <5 dB. Both the experimental and simulation results are in good agreement.


Assuntos
Desenho Assistido por Computador , Modelos Teóricos , Óptica e Fotônica/instrumentação , Silício/química , Telecomunicações/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Vibração
13.
Opt Express ; 16(12): 8359-65, 2008 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-18545550

RESUMO

A passive ring-assisted Mach-Zehnder interferometer optical interleaver comprising a Y-bench, a 3-dB directional coupler, a ring-resonator, and a delay line is proposed. The interleaver is fabricated with 300 nm x 300 nm silicon wires on silicon-on-insulator. The fabricated interleaver demonstrates a flat-top spectral response. The measured free-spectral range is approximately 4 nm, the insertion loss is approximately -8 dB, and the crosstalk is <- 10 dB. Both the experimental and simulation results are in good agreement.


Assuntos
Interferometria/instrumentação , Modelos Teóricos , Óptica e Fotônica/instrumentação , Refratometria/instrumentação , Silício/química , Simulação por Computador , Condutividade Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Espalhamento de Radiação
14.
Opt Express ; 16(26): 21456-61, 2008 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-19104575

RESUMO

A 1 x 16 optical power splitter with wide splitting angle, uniform outputs, and low excess loss is demonstrated. The 1 x 16 splitter comprising cascaded 1 x 2 splitters with arc-shaped branching waveguides is fabricated on the silicon-on-insulator (SOI) substrate. The gap between the branching waveguides is widened in a short propagation length such that influences of etch residues and air voids in the gap on the optical power uniformity are reduced significantly. The measured power uniformity of the 1 x 16 splitter is better than 0.3 dB at wavelength of 1550 nm.

15.
Opt Express ; 16(25): 20809-16, 2008 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-19065219

RESUMO

We investigated low-hydrogen SiN films prepared by a low temperature (350 degrees C) PECVD method. The impact of SiH(4)/N(2) flow ratio and radio frequency power on the hydrogen content in the SiN films was studied. In this work, we demonstrated a low-loss sub-micron SiN waveguide by using the corresponding optimal SiN films. The propagation loss was found to be as low as -2.1+/-0.2 dB/cm at 1550 nm with waveguide cross-section of 700 nm x 400 nm. The results suggest that the SiN films grown by PECVD with low hydrogen can be used in photonics integrated circuits for new generation communications applications.


Assuntos
Desenho Assistido por Computador , Hidrogênio/química , Modelos Teóricos , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Dispositivos Ópticos , Compostos de Silício/química , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Espalhamento de Radiação
16.
Opt Express ; 16(11): 7842-8, 2008 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-18545494

RESUMO

Ultrafast high-density photonic integrated circuit devices (PICDs) are not easily obtained using traditional index-guiding mechanisms. In this paper, photonic bandgap crystal resonator enhanced, laser-controlled modulations of optical interconnect PICDs were achieved in slab-type mix-guiding configuration - through developed CMOS-compatible processing technologies. The devices, with smallest critical dimensions of 90 nm have footprints of less than 5 x 5 microm(2). Quality-factors an order larger than previously realized was achieved. Through use of effective coupling structures; simultaneous alignment for probing and pumping laser beams, optical measurements of both instantaneous free carriers induced device modulations were obtained together with thermo-optical effects characterizations.


Assuntos
Desenho Assistido por Computador , Modelos Teóricos , Óptica e Fotônica/instrumentação , Telecomunicações/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Fótons
17.
Opt Express ; 16(26): 21476-82, 2008 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-19104577

RESUMO

A cross-ring (CR-) Mach-Zehnder interferometer (MZI) interleaver structure has been proposed and fabricated. It uses an '8' shaped cross-ring resonator to replace the conventional circular ring resonator. Thus, the new structure can have the function of add-signal. Furthermore, a thermo-optical fine tuning has been applied, which improves the crosstalk performance from approximately -10 dB to approximately -20 dB with 9 V applied on the heater of the 3-dB directional coupler.

18.
Opt Express ; 14(19): 8812-26, 2006 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-19529263

RESUMO

A three dimensional analysis of a special class of anisotropic materials is presented. We introduce an extension of the Scattering Matrix Method (SMM) to investigate the behavior of anisotropic Photonic Crystal Slabs (PhCS) subject to external radiation. We show how the Fano effect can play a fundamental role in the realization of tunable optical devices. Moreover, we show how to utilize electron injection, electric field and temperature as parameters to control the Fano resonance shift in both isotropic and anisotropic materials as Si and Potassium Titanium Oxide Phosphate (KTP). We will see that because Fano modes are sensitive and controllable, a broad range of applications can be considered.

19.
Chin Med J (Engl) ; 106(9): 679-81, 1993 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8287704

RESUMO

Smooth muscle fibers are considered very important in penile erection and relaxation. The reduction of intracavernosus smooth muscle fibers can provoke impotence. The percentage of smooth muscle fibers in corpus cavernosum specimens was studied quantitatively in normal men and impotence patients by means of computerized image analysis. The percentage of smooth muscle fibers in the specimens of 14 normal men, ranged from 41% to 61% (average 50%) and in 12 impotence patients, it was 22% to 46% (average 31%). A decrease of smooth muscle fibers and an increase of collagen fibers were noted in impotence patients.


Assuntos
Disfunção Erétil/patologia , Músculo Liso/patologia , Adulto , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Pênis/patologia
20.
Zhonghua Yan Ke Za Zhi ; 30(5): 341-4, 1994 Sep.
Artigo em Zh | MEDLINE | ID: mdl-7805534

RESUMO

The full threshold program of QZS-2 automated perimetry made in China was used to measure the retinal light sensitivity of the central 30 degrees and peripheral 30 degrees-60 degrees visual fields of 111 eyes of 59 normal persons. Their ages ranged from 15-68 years and the average age was 38.4 years. From the corresponding respective comparisons of the results, it is shown that the mean light sensitivity of the macular, central 30 degrees and peripheral 30 degrees-60 degrees visual fields between the left and right eyes has no statistical significant differences (P > 0.05), and there are also no statistical significant differences (P > 0.05) in the mean light sensitivity of the central and peripheral fields between the male and female subjects. The mean light sensitivity declines linearly with the increase of age and eccentricity. The mean light sensitivity of the central and peripheral visual fields decreases 0.6 dB and 0.7 dB, respectively, with each one decade increase of age. The mean light sensitivity also decreases by 2.6 dB per 10 degrees eccentricity. The mean short-term fluctuation in the normal subjects is 1.39 +/- 0.56 dB.


Assuntos
Luz , Retina/fisiologia , Campos Visuais/fisiologia , Percepção Visual , Adolescente , Adulto , Fatores Etários , Idoso , Feminino , Glaucoma/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Limiar Sensorial , Testes de Campo Visual
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa