Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 148
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 60(5): 2207-2213, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38376448

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI)-based virtual MR elastography (DWI-vMRE) in the assessment of breast lesions is still in the research stage. PURPOSE: To investigate the usefulness of elasticity values on DWI-vMRE in the evaluation of breast lesions, and the correlation with the values calculated from shear-wave elastography (SWE). STUDY TYPE: Prospective. POPULATION/SUBJECTS: 153 patients (mean age ± standard deviation: 55 ± 12 years) with 153 pathological confirmed breast lesions (24 benign and 129 malignant lesions). FIELD STRENGTH/SEQUENCE: 1.5-T MRI, multi-b readout segmented echo planar imaging (b-values of 0, 200, 800, and 1000 sec/mm2). ASSESSMENT: For DWI-vMRE assessment, lesions were manually segmented using apparent diffusion coefficient (ADC0-1000) map, then the region of interests were copied to the map of shifted-ADC (sADC200-800, sADC 200-1500). For SWE assessment, the shear modulus of the lesions was measured by US elastic modulus (µUSE). Intraclass/interclass kappa coefficients were calculated to measure the consistency. STATISTICAL TESTS: Pearson's correlation was used to assess the relationship between sADC and µUSE. A receiver operating characteristic analysis with the area under the curve (AUC) was performed to compare the diagnostic accuracy between benign and malignant breast lesions of sADC and µUSE. A P value <0.05 was considered statistically significant. RESULTS: There were significant differences between benign and malignant breast lesions of µUSE (24.17 ± 10.64 vs. 37.20 ± 12.61), sADC200-800 (1.38 ± 0.31 vs. 0.97 ± 0.18 × 10-3 mm2/sec), and sADC200-1500 (1.14 ± 0.30 vs. 0.78 ± 0.13 × 10-3 mm2/sec). In all breast lesions, a moderate but significant correlation was observed between µUSE and sADC200-800/sADC200-1500 (r = -0.49/-0.44). AUC values to differentiate benign from malignant lesions were as follows: µUSE, 0.78; sADC200-800, 0.89; sADC200-1500, 0.89. DATA CONCLUSIONS: Both SWE and DWI-vMRE could be used for the differentiation of benign versus malignant breast lesions. Furthermore, DWI-vMRE with the use of sADC show relatively higher AUC values than SWE. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 2.


Assuntos
Neoplasias da Mama , Mama , Imagem de Difusão por Ressonância Magnética , Técnicas de Imagem por Elasticidade , Humanos , Técnicas de Imagem por Elasticidade/métodos , Feminino , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Estudos Prospectivos , Mama/diagnóstico por imagem , Idoso , Adulto , Reprodutibilidade dos Testes , Imagem Ecoplanar/métodos , Módulo de Elasticidade , Interpretação de Imagem Assistida por Computador/métodos , Curva ROC , Sensibilidade e Especificidade
2.
Eur Radiol ; 34(3): 1597-1604, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37665388

RESUMO

OBJECTIVE: This prospective observational study aimed to evaluate the efficacy of radiofrequency ablation (RFA) in treating ≤ 2 cm thyroid nodules with Bethesda IV cytology and C-TIRADS 4A categorization. Additionally, the factors influencing the completed absorption of ablation (CAA) were examined. METHODS: A total of 62 cases with 62 nodules underwent ultrasound-guided RFA and were included in the study. The volume reduction rate (VRR), CAA, and incomplete absorption of ablation (IAA) were assessed at the 1st, 3rd, 6th, and subsequent 6-month follow-ups. Clinical and ultrasound features were compared between the CAA and IAA groups at the 12th month follow-up. RESULTS: The average VRR at the 1st, 3rd, 6th, 12th month, and last follow-up were -88.6%, 16.0%, 59.7%, 82.0%, and 98.2%, respectively. More than half of the nodules achieved a 90% VRR after 1 year of RFA, with 88.7% demonstrating CAA at the end of the study (follow-up duration of 14 to 63 months). Nodules with grade 3 vascularity and those associated with chronic thyroiditis showed delayed CAA at the 12th month follow-up (p = 0.036 and 0.003, respectively). CONCLUSION: RFA is an effective technique for treating ≤ 2 cm thyroid nodules with Bethesda IV cytology and C-TIRADS 4A categorization. Nodules with grade 3 blood supply and patients with chronic thyroiditis exhibited an impact on the completed absorption following RFA. CLINICAL RELEVANCE STATEMENT: Our study has shown that radiofrequency ablation is an effective treatment for ≤ 2 cm thyroid nodules classified as Bethesda IV cytology. However, we identified that high vascularity of the nodule and chronic thyroiditis are adverse factors affecting the completed absorption of the ablation. KEY POINTS: •Radiofrequency ablation (RFA) is an effective technique for treatment of ≤ 2 cm Bethesda IV category thyroid nodules. •Higher blood supply and chronic thyroiditis influence the completed absorption after RFA.


Assuntos
Ablação por Cateter , Doença de Hashimoto , Ablação por Radiofrequência , Nódulo da Glândula Tireoide , Tireoidite , Humanos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/cirurgia , Ablação por Radiofrequência/métodos , Resultado do Tratamento , Ultrassonografia , Estudos Retrospectivos , Ablação por Cateter/métodos
3.
Int J Hyperthermia ; 41(1): 2379983, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39013550

RESUMO

As the utilization of high-resolution imaging modalities, such as ultrasound, becomes increasingly prevalent, there has been a swift rise in the detection rates of malignant thyroid nodules (MTC). Surgery remains the cornerstone of standard treatment for these nodules. However, the advent and evolution of thermal ablation (TA) techniques, encompassing radiofrequency ablation, laser ablation, and microwave ablation, have emerged as a novel therapeutic avenue for patients with MTC, particularly for those deemed unsuitable for surgery due to high risks or for those who refuse surgery. Presently, TA has been validated as an efficacious and safe intervention for both benign thyroid nodules and a subset of MTC. An expanding body of research has been dedicated to broadening the applicability of TA, initially from recurrent thyroid cancer and lymph nodes to now encompass isolated papillary thyroid microcarcinomas (PTMC) alongside a comprehensive exploration into the expanded parameters such as size, number, and location of PTMC, and its applicability in other types of thyroid cancer. This review provides a detailed synthesis of the clinical evidence about the use of TA in the management of MTC, as endorsed by current guidelines. It further delves into the ongoing research efforts aimed at extending its indications and discusses the prospective implications and challenges of integrating TA into the clinical management paradigms for MTC.


Assuntos
Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/cirurgia , Técnicas de Ablação/métodos
4.
Sensors (Basel) ; 24(12)2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38931738

RESUMO

Borehole strain gauges play a crucial role in geophysical, seismological, and crustal dynamics studies. While existing borehole strain gauges are proficient in measuring horizontal strains within vertical boreholes, their effectiveness in capturing vertical and oblique strains is limited due to technical constraints arising from the cylindrical probe's characteristics. However, the accurate measurement of three-dimensional strain is essential for a comprehensive understanding of crustal tectonics, dynamics, and geophysics, particularly considering the diverse geological structures and force sources within the crustal medium. In this study, we present a novel approach to address this challenge by enhancing an existing horizontal-component borehole strain gauge with a bellows structure and line strain measurement technology to enable vertical and borehole oblique strain measurements. Integrating these enhancements with horizontal strain measurement capabilities enables comprehensive three-dimensional borehole strain measurements within the same hole section. The system was deployed and tested at the Gongxian seismic station in Sichuan Province. Clear observations of solid tides were recorded across horizontal, oblique, and vertical measurement units, with the tidal morphology and amplitude being consistent with the theoretical calculations. The achieved measurement sensitivity of 10-10 meets the requirements for borehole strain measurement, enabling the characterization of three-dimensional strain states within boreholes through association methods.

5.
Radiology ; 307(5): e221157, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37338356

RESUMO

Background Artificial intelligence (AI) models have improved US assessment of thyroid nodules; however, the lack of generalizability limits the application of these models. Purpose To develop AI models for segmentation and classification of thyroid nodules in US using diverse data sets from nationwide hospitals and multiple vendors, and to measure the impact of the AI models on diagnostic performance. Materials and Methods This retrospective study included consecutive patients with pathologically confirmed thyroid nodules who underwent US using equipment from 12 vendors at 208 hospitals across China from November 2017 to January 2019. The detection, segmentation, and classification models were developed based on the subset or complete set of images. Model performance was evaluated by precision and recall, Dice coefficient, and area under the receiver operating characteristic curve (AUC) analyses. Three scenarios (diagnosis without AI assistance, with freestyle AI assistance, and with rule-based AI assistance) were compared with three senior and three junior radiologists to optimize incorporation of AI into clinical practice. Results A total of 10 023 patients (median age, 46 years [IQR 37-55 years]; 7669 female) were included. The detection, segmentation, and classification models had an average precision, Dice coefficient, and AUC of 0.98 (95% CI: 0.96, 0.99), 0.86 (95% CI: 0.86, 0.87), and 0.90 (95% CI: 0.88, 0.92), respectively. The segmentation model trained on the nationwide data and classification model trained on the mixed vendor data exhibited the best performance, with a Dice coefficient of 0.91 (95% CI: 0.90, 0.91) and AUC of 0.98 (95% CI: 0.97, 1.00), respectively. The AI model outperformed all senior and junior radiologists (P < .05 for all comparisons), and the diagnostic accuracies of all radiologists were improved (P < .05 for all comparisons) with rule-based AI assistance. Conclusion Thyroid US AI models developed from diverse data sets had high diagnostic performance among the Chinese population. Rule-based AI assistance improved the performance of radiologists in thyroid cancer diagnosis. © RSNA, 2023 Supplemental material is available for this article.


Assuntos
Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Humanos , Feminino , Pessoa de Meia-Idade , Inteligência Artificial , Nódulo da Glândula Tireoide/diagnóstico por imagem , Estudos Retrospectivos
6.
Eur Radiol ; 33(4): 2954-2964, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36418619

RESUMO

OBJECTIVES: To establish a breast lesion risk stratification system using ultrasound images to predict breast malignancy and assess Breast Imaging Reporting and Data System (BI-RADS) categories simultaneously. METHODS: This multicenter study prospectively collected a dataset of ultrasound images for 5012 patients at thirty-two hospitals from December 2018 to December 2020. A deep learning (DL) model was developed to conduct binary categorization (benign and malignant) and BI-RADS categories (2, 3, 4a, 4b, 4c, and 5) simultaneously. The training set of 4212 patients and the internal test set of 416 patients were from thirty hospitals. The remaining two hospitals with 384 patients were used as an external test set. Three experienced radiologists performed a reader study on 324 patients randomly selected from the test sets. We compared the performance of the DL model with that of three radiologists and the consensus of the three radiologists. RESULTS: In the external test set, the DL model achieved areas under the receiver operating characteristic curve (AUCs) of 0.980 and 0.945 for the binary categorization and six-way categorizations, respectively. In the reader study set, the DL BI-RADS categories achieved a similar AUC (0.901 vs. 0.933, p = 0.0632), sensitivity (90.98% vs. 95.90%, p = 0.1094), and accuracy (83.33% vs. 79.01%, p = 0.0541), but higher specificity (78.71% vs. 68.81%, p = 0.0012) than those of the consensus of the three radiologists. CONCLUSIONS: The DL model performed well in distinguishing benign from malignant breast lesions and yielded outcomes similar to experienced radiologists. This indicates the potential applicability of the DL model in clinical diagnosis. KEY POINTS: • The DL model can achieve binary categorization for benign and malignant breast lesions and six-way BI-RADS categorizations for categories 2, 3, 4a, 4b, 4c, and 5, simultaneously. • The DL model showed acceptable agreement with radiologists for the classification of breast lesions. • The DL model performed well in distinguishing benign from malignant breast lesions and had promise in helping reduce unnecessary biopsies of BI-RADS 4a lesions.


Assuntos
Neoplasias da Mama , Aprendizado Profundo , Humanos , Feminino , Neoplasias da Mama/patologia , Mama/diagnóstico por imagem , Ultrassonografia , Medição de Risco , Ultrassonografia Mamária/métodos , Estudos Retrospectivos
7.
Sensors (Basel) ; 23(15)2023 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-37571765

RESUMO

In this study, an FPGA(Field Programmable Gate Array)-based borehole strain measurement system was designed that makes extensive use of digital signal processing operations to replace analog circuits. Through the formidable operational capability of FPGA, the sampled data were filtered and denoised to improve the signal-to-noise ratios. Then, with the goal of not reducing observational accuracy, the signal amplification circuit was removed, the excitation voltage was reduced, and the dynamic range of the primary adjustments was expanded to 130 dB. The system's online compilation function made it more flexible to changes in measurement parameters, allowing it to adapt to various needs. In addition, the efficiency of the equipment use was enhanced. The actual observational results showed that this study's FPGA-based borehole strain measurement system had a voltage resolution higher than 1 µV. Clear solid tides were successfully recorded in low-frequency bands, and seismic wave strain was accurately recorded in high-frequency bands. The arrival times and seismic phases of the seismic waves S and P were clearly recorded, which met the requirements for geophysical field deformation observations. Therefore, the system proposed in this study is of major significance for future analyses of geophysical and crust deformation observations.

8.
Sensors (Basel) ; 23(18)2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37766052

RESUMO

This paper presents a high-precision component-type vertical pendulum tiltmeter based on an FPGA (Field Programmable Gate Array) that improves the utility and reliability of geophysical field tilt observation instruments. The system is designed for rapid deployment and offers flexible and efficient adaptability. It comprises a pendulum body, a triangular platform, a locking motor and sealing cover, a ratiometric measurement bridge, a high-speed ADC, and an FPGA embedded system. The pendulum body is a plumb-bob-type single-suspension wire vertical pendulum capable of measuring ground tilt in two orthogonal directions simultaneously. It is installed on a triangular platform, sealed as a whole, and equipped with a locking motor to withstand a free-fall impact of 2 m. The system utilizes a differential capacitance ratio bridge in the measurement circuit, replacing analog circuits with high-speed AD sampling and FPGA digital signal processing technology. This approach reduces hardware expenses and interferences from active devices. The system also features online compilation functionality for flexible measurement parameter settings, high reliability, ease of use, and rapid deployment without the need for professional technical personnel. The proposed tiltmeter holds significant importance for further research in geophysics.

9.
J Clin Ultrasound ; 51(5): 901-907, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37026595

RESUMO

OBJECTIVE: This study evaluates the correlation between the sonographic features and the nodal fine-needle aspiration thyroglobulin (FNA-Tg) in papillary thyroid carcinoma (PTC) patients with the recurrent/persistent lymph node for the purpose of the reasonable selection of lymph nodes. METHODS: This study prospectively contained PTC patients with the suspicious cervical lymph nodes in one medical center from April 2018 to January 2019. Each suspected lymph node was aspirated with a 22-gauge needle and the value of FNA-Tg was measured as well. RESULTS: There were 136 lymph nodes related to the disease involved. The FNA-Tg levels of 89 (65.44%) metastatic lymph nodes were significantly higher than those of the benign. The median value of the former was 631.550 ng/mL while the latter was 0.056 ng/mL (p = 0.000). The cut-off value of the metastatic lymph nodes diagnosed by FNA-Tg was 2.71 ng/mL, and 6.5 by FNA-Tg/sTg. The suspicious ultrasonographic features including cystic, hyperechoic content, and lack of hilum were closely related to the high level of FNA-Tg value (p < 0.05). However, the round shape (Solbiati index <2) and calcification were not significantly correlated with the positive FNA-Tg (p > 0.05). CONCLUSION: FNA-Tg is an effective supplement to fine-needle aspiration (FNA) cytology in the nodal metastasis diagnosis. The FNA-Tg level was much higher in the metastatic lymph nodes. The reliable sonographic features of lymph nodes suggested the positive FNA-Tg were cystic content, hyperechoic content and lack hilum. Solbiati index <2 and calcification did not show an exact correlation with the result of FNA-Tg.


Assuntos
Calcinose , Neoplasias da Glândula Tireoide , Humanos , Tireoglobulina , Câncer Papilífero da Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/patologia , Pescoço , Linfonodos/diagnóstico por imagem , Linfonodos/patologia
10.
BMC Cancer ; 22(1): 455, 2022 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-35473499

RESUMO

OBJECTIVE: The study conducted a multicenter study in China to explore the learning curve of contrast enhanced ultrasound (CEUS) for sentinel lymph nodes (SLNs), the feasibility of using this technique for the localization of SLNs and lymphatic channels (LCs) and its diagnostic performance for lymph node metastasis. METHOD: Nine hundred two patients with early invasive breast cancer from six tertiary class hospitals in China were enrolled between December 2016 and December 2019. Each patient received general ultrasound scanning and SLN-CEUS before surgery. The locations and sizes of LCs and SLNs were marked on the body surface based on observations from SLN-CEUS. These body surface markers were then compared with intraoperative blue staining in terms of their locations. The first 40 patients from each center were included in determining the learning curve of SLN-CEUS across sites. The remaining patients were used to investigate the diagnostic efficacy of this technique in comparison with intraoperative blue staining and pathology respectively. RESULT: The ultrasound doctor can master SLN-CEUS after 25 cases, and the mean operating time is 22.5 min. The sensitivity, specificity, negative predictive value, and positive predictive value of SLN-CEUS in diagnosing lymph node metastases were 86.47, 89.81, 74.90, and 94.97% respectively. CONCLUSION: Ultrasound doctors can master SLN-CEUS with a suitable learning curve. SLN-CEUS is a feasible and useful approach to locate SLNs and LCs before surgery and it is helpful for diagnosing LN metastases.


Assuntos
Neoplasias da Mama , Linfadenopatia , Linfonodo Sentinela , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Meios de Contraste , Feminino , Humanos , Linfadenopatia/patologia , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/patologia , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/patologia , Linfonodo Sentinela/cirurgia , Biópsia de Linfonodo Sentinela/métodos , Ultrassonografia/métodos
11.
BMC Med Imaging ; 22(1): 151, 2022 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-36038830

RESUMO

BACKGROUND: To investigate sonographic features of cervical lymph node metastases from medullary thyroid cancer (LNM-MTC), as compared with lymph node metastases from papillary thyroid cancer (LNM-PTC). METHODS: A total of 42 MTC patients with 52 metastatic LNs and 222 PTC patients with 234 metastatic LNs who were confirmed by fine needle aspiration and post-operative pathology, were enrolled in this study. The clinical characteristics and sonographic features of LNs were compared between the two groups. Univariate analysis and multivariate logistic regression analysis were performed on the sonographic features of LNs, including short and long-axis diameter, long-axis diameter/short-axis, shape, border, hilum, echogenicity, calcifications, cystic change and vascularity pattern. The discriminating performance was assessed with the area under the receiver operating characteristic curve (AUC). RESULTS: The mean age of patients with LNM-MTC was older than that of patients with LNM-PTC (46.81 ± 13.05 vs 39.09 ± 12.05, P < 0.001). No differences were observed in gender, location, long-axis diameter/short-axis, shape, border, echogenicity, cystic change and vascularity pattern between LNM-MTC and LNM-PTC groups (P > 0.05, for all). However, long-axis and short-axis diameter, hilum and calcifications were statistically different between these two groups (P < 0.05, for all). The AUC of discriminate value between LNM-MTC and LNM-PTC was 0.808 (95% confidence interval 0.739-0.877). CONCLUSION: Compared with LNM-PTC, LNM-MTC tended to have the sonographic characteristics of larger size, absence of hilum, and less calcifications, and awareness of these features might be helpful to in the diagnosis of LNM-MTC.


Assuntos
Carcinoma Papilar , Neoplasias da Glândula Tireoide , Carcinoma Neuroendócrino , Carcinoma Papilar/patologia , Carcinoma Papilar/cirurgia , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Metástase Linfática/diagnóstico por imagem , Estudos Retrospectivos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia
12.
BMC Med Imaging ; 22(1): 82, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-35501717

RESUMO

BACKGROUND: An accurate preoperative assessment of cervical lymph node metastasis (LNM) is important for choosing an optimal therapeutic strategy for papillary thyroid carcinoma (PTC) patients. This study aimed to develop and validate two ultrasound (US) nomograms for the individual prediction of central and lateral compartment LNM in patients with PTC. METHODS: A total of 720 PTC patients from 3 institutions were enrolled in this study. They were categorized into a primary cohort, an internal validation, and two external validation cohorts. Radiomics features were extracted from conventional US images. LASSO regression was used to select optimized features to construct the radiomics signature. Two nomograms integrating independent clinical variables and radiomics signature were established with multivariate logistic regression. The performance of the nomograms was assessed with regard to discrimination, calibration, and clinical usefulness. RESULTS: The radiomics scores were significantly higher in patients with central/lateral LNM. A radiomics nomogram indicated good discrimination for central compartment LNM, with an area under the curve (AUC) of 0.875 in the training set, the corresponding value in the validation sets were 0.856, 0.870 and 0.870, respectively. Another nomogram for predicting lateral LNM also demonstrated good performance with an AUC of 0.938 and 0.905 in the training and internal validation cohorts, respectively. The AUC for the two external validation cohorts were 0.881 and 0.903, respectively. The clinical utility of the nomograms was confirmed by the decision curve analysis. CONCLUSION: The nomograms proposed here have favorable performance for preoperatively predicting cervical LNM, hold promise for optimizing the personalized treatment, and might greatly facilitate the decision-making in clinical practice.


Assuntos
Linfonodos , Neoplasias da Glândula Tireoide , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Linfonodos/cirurgia , Metástase Linfática/diagnóstico por imagem , Câncer Papilífero da Tireoide/diagnóstico por imagem , Câncer Papilífero da Tireoide/patologia , Câncer Papilífero da Tireoide/cirurgia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/cirurgia , Ultrassonografia
13.
Sensors (Basel) ; 22(20)2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-36298146

RESUMO

To reliably realize the functions of autonomous navigation and cruise of logistics robots in a complex logistics storage environment, this paper proposes a new robot navigation system based on vision and multiline lidar information fusion, which can not only ensure rich information and accurate map edges, but also meet the real-time and accurate positioning and navigation in complex logistics storage scenarios. Simulation and practical verification showed that the robot navigation system is feasible and robust, and overcomes the problems of low precision, poor robustness, weak portability, and difficult expansion of the mobile robot system in a complex environment. It provides a new idea for inspection in an actual logistics storage scenario and has a good prospective application.


Assuntos
Robótica , Visão Ocular , Simulação por Computador
14.
Eur Radiol ; 31(11): 8458-8467, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33881571

RESUMO

OBJECTIVES: Up to 40% of papillary thyroid cancer (PTC) patients have lymph node metastasis, a condition that implies persistent, recurrent, or progressive disease. However, the American Joint Committee on Cancer Manual states that there is no reliable examination for adequate lymph node staging. Therefore, our aim is to develop a lymphatic imaging technique using ultrasonography to address this challenge. METHODS: We consecutively enrolled PTC patients who underwent ultrasound (US) lymphatic imaging via the peritumoral injection of contrast media. Identification of the sentinel lymph nodes and the targeted sentinel lymph nodes was separately based on the lymphatic drainage pathway and the enhancement patterns. Every identified targeted node was assigned a score, according to the features on conventional US and enhancement patterns, and was referred for ultrasound-guided fine-needle aspiration. Cytological and histopathologic results represented the statuses of the targeted lymph nodes and overall central lymph nodes, respectively, which were applied to evaluate the diagnostic performance of US lymphatic imaging. RESULTS: In total, 100 PTC patients were included. On the basis of the cytological results, the sensitivity (97.1%, 95% confidence interval [CI]: 84.7-99.9%) of detecting positive targeted nodes by US lymphatic imaging significantly increased by 45.5% at a threshold of 4 or higher (p = 0.0001), without loss of specificity (p = 1.0000). The surgical results showed that the metastatic degree was positively correlated with an increase in the score (τ: 0.671, p < 0.001). CONCLUSION: Ultrasound lymphatic imaging has a high diagnostic performance, and its corresponding scoring system facilitates grading of the nodal burden in the central compartment. KEY POINTS: • Ultrasound neck lymphatic imaging is an effective contrast-enhanced ultrasound (CEUS) technique (applied after the peritumoral injection of contrast media) for identifying sentinel lymph nodes in the central compartment by tracing the imaged afferent lymphatic vessel. • Lack of enhancement or perfusion defects is the typical enhancement pattern for recognizing the involved central lymph nodes. • Ultrasound lymphatic imaging for identification of positive central lymph nodes before surgery may effectively avoid complications associated with the surgical sentinel node procedure.


Assuntos
Vasos Linfáticos , Neoplasias da Glândula Tireoide , Humanos , Linfonodos/diagnóstico por imagem , Biópsia de Linfonodo Sentinela , Câncer Papilífero da Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/cirurgia , Ultrassonografia
15.
BMC Med Imaging ; 20(1): 49, 2020 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-32410587

RESUMO

BACKGROUND: To identify the sonographic features that help to differentiate medullary thyroid microcarcinomas (MTMCs) from papillary thyroid microcarcinomas (PTMCs). METHODS: A total of 46 MTMCs in 41 patients and 136 PTMCs in 104 patients that were proven by surgery and pathology were included in the study. Patient age and nodule size were analyzed by independent sample t-tests, and sex, multiplicity and cervical lymph node metastases were analyzed by χ2 or Fisher's exact tests. Univariate analysis and multivariate logistic regression analysis were performed on the sonographic features of thyroid nodules, including location, shape, boundary, margin, peripheral halo ring, echogenicity, composition, calcifications and vascularization. RESULTS: Compared with the corresponding number of patients with PTMCs, more MTMC patients had cervical lymph node metastases (P = 0.040). There were no significant differences in age, sex, nodule size, multiplicity, location, boundary, margin, peripheral halo ring, echogenicity or microcalcifications between MTMCs and PTMCs (P > 0.05 for all). However, significant differences were found in shape (P = 0.000), composition (P = 0.032), macrocalcifications (P = 0.004) and vascularity (P = 0.000) between the two groups. CONCLUSIONS: There were some overlapping sonographic features between MTMCs and PTMCs. However, MTMCs tended to have a > 50% solid composition, be ovoid to round nodules with macrocalcifications and be hypervascular. Cervical lymph node metastases were more common in MTMC patients.


Assuntos
Carcinoma Medular/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Câncer Papilífero da Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Medular/patologia , Carcinoma Medular/cirurgia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço , Estudos Retrospectivos , Câncer Papilífero da Tireoide/patologia , Câncer Papilífero da Tireoide/cirurgia , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/cirurgia , Ultrassonografia , Adulto Jovem
16.
Lasers Surg Med ; 52(9): 855-862, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32216112

RESUMO

BACKGROUND AND OBJECTIVES: The objective of this study is to compare the efficacy and the safety of ultrasound-guided microwave ablation (MWA) and laser ablation (LA) for the treatment of papillary thyroid microcarcinoma (PTMC). STUDY DESIGN/MATERIALS AND METHODS: A total of 67 patients with unifocal PTMC were studied retrospectively, including 33 cases who underwent MWA (MWA group) and 34 cases who received LA (LA group). The follow-up consisted of thyroid function tests, ultrasonography, contrast-enhanced ultrasonography (CEUS), and chest X-ray or computed tomography scan. The treatment response and complications were compared between the two groups. RESULTS: The follow-up time for the MWA and LA group was 23.3 ± 4.4 and 22.8 ± 4.1 months, respectively. All the ablations were successfully performed as planned without complementary ablations, and it was confirmed by CEUS after treatment in both groups. It was observed that, at the last follow-up, the mean largest diameter decreased from 5.0 ± 1.4 mm to 0.1 ± 0.4 mm (MWA group) and from 4.5 ± 1.6 mm to 0.6 ± 1.2 mm(LA group) (P < 0.05 for both). The average volume reduced from 51.9 ± 40.8 to 0.2 ± 1.0 mm3 (MWA group) and from 38.5 ± 43.0 to 1.3 ± 3.8 mm3 (LA group) (P < 0.05 for both). The complication rates did not differ between the MWA group (9.1%) and the LA group (2.9%) (P > 0.05). No local recurrence or distant metastasis occurred in either group. CONCLUSIONS: During the short-term follow-up period, ultrasound-guided MWA and LA were both safe and effective methods in treating patients with unifocal PTMC. Lasers Surg. Med. © 2020 Wiley Periodicals, Inc.


Assuntos
Ablação por Cateter , Terapia a Laser , Carcinoma Papilar , Humanos , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Neoplasias da Glândula Tireoide , Resultado do Tratamento , Ultrassonografia , Ultrassonografia de Intervenção
17.
J Ultrasound Med ; 39(10): 2071-2080, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32352187

RESUMO

OBJECTIVES: To investigate the independent risk factors for cervical lymph node metastasis (CLNM) in patients with papillary thyroid carcinoma (PTC) and establish a prediction model via conventional ultrasound (US) and contrast-enhanced ultrasound (CEUS). METHODS: A total of 275 patients with single PTC, who were admitted to our hospital from January 2016 to December 2018, were enrolled in this study. The clinical characteristics and features of the tumor on conventional US and CEUS were retrospectively analyzed. A binary logistic regression model was established, and the diagnostic efficacy of conventional US and CEUS was compared. RESULTS: The binary logistic regression analysis showed that age younger than 38 years, size of 10.0 mm or greater, solid composition, peak of the nodule interior of 28.3750 or greater, and area under the curve (AUC) of the peripheral ring of less than 3.2500 were independent risk factors of CLNM (P < .05, for all). Prediction model: Logit (p) = -4.135 + 1.040 (age) + 1.920 (size) + 1.769 (composition) + 1.230 (peak of nodule interior) + 0.812 (AUC of peripheral ring). The model positively predicted CLNM at a value of L > -0.199. The AUC, sensitivity, and negative predictive value of the receiver operating characteristic curve for the model were 0.727, 71.7%, and 75.2%, respectively, which were significantly higher than those of conventional US (Z = -2.403; P = .016; Z = -5.330; P < .001; and Z = -2.390; P = .017). The specificity of the model was 73.7%, which was lower than that of conventional US (Z = 3.508; P < .001). CONCLUSIONS: The preoperative prediction model established via conventional US and CEUS may be helpful to evaluate CLNM in patients with PTC and determine the appropriate treatment options.


Assuntos
Neoplasias da Glândula Tireoide , Adulto , Pré-Escolar , Humanos , Lactente , Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Estudos Retrospectivos , Câncer Papilífero da Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia
18.
Clin Endocrinol (Oxf) ; 91(1): 201-208, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31004514

RESUMO

OBJECTIVE: To evaluate the value of shear wave elastography (SWE) in avoiding repeat fine-needle aspiration of thyroid nodules with nondiagnostic and undetermined cytology. METHODS: A total of 232 thyroid nodules with nondiagnostic (n = 132) and undetermined (n = 100) cytology underwent ultrasound (US) and SWE, followed by repeat ultrasound (US)-guided fine-needle aspiration cytology (FNAC). The final diagnosis was based on cytological or pathological findings. The US and SWE characteristics of benign and malignant nodules were compared using the χ2 -test. The receiver operating characteristic (ROC) curves of the thyroid imaging reporting and data system (TI-RADS) categories from the US and the EMean and ESD from the SWE were graphed, and the areas under the curves (AUCs) were compared using a Z test. RESULTS: There were significant differences between the benign and malignant nodules in terms of the echogenicity, shape, margin, calcification and TI-RADS categories (all P < 0.05). The differences were significant between the malignant and benign nodules for EMean [(34.57 ± 14.81) kPa vs. (19.18 ± 7.09) kPa] and ESD [(13.68 ± 13.01) kPa vs. (3.97 ± 2.58) kPa] (both P < 0.001). Though the difference in the AUCs of EMean (0.864) and ESD (0.876) was not significant (P = 0.745), they both had higher diagnostic performances in comparison with TI-RADS categories (0.762) (all P < 0.05). Moreover, ESD attained a sensitivity of 100% with a relatively higher specificity of 49.75% when its cut-off value was 3.3 kPa. CONCLUSIONS: Shear wave elastography is a promising imaging method for reducing repeat FNAC for benign thyroid nodules with nondiagnostic and undetermined cytology when using ESD as an index.


Assuntos
Biópsia por Agulha Fina/métodos , Técnicas de Imagem por Elasticidade/métodos , Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Adulto Jovem
19.
Int J Hyperthermia ; 36(1): 897-904, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31464140

RESUMO

Objectives: To compare the clinical outcomes of ultrasound-guided laser ablation (LA) and surgery for treatment of solitary papillary thyroid microcarcinoma (PTMC). Methods: A total of 81 consecutive patients with solitary PTMC were included in this retrospective study. Among them, 36 received LA and 45 underwent surgery. Surgery was performed by hemithyroidectomy with unilateral central neck dissection. The follow-up consisted of a physical examination, neck ultrasonography, chest X-ray or CT scan and thyroid function tests. The procedure time, hospital stay, complication and recurrence rates were compared between the two groups after treatment. Results: The follow-up period for the LA and surgical group were 49.2 ± 4.5 months (range, 30-54 months) and 48.5 ± 6.2 months (range, 24-54 months), respectively. The mean hospital stay and procedure time in the LA group were shorter than those in the surgical group. After LA, the largest diameter and average volume decreased from 4.7 ± 1.4 mm to 0.2 ± 0.8 mm, and from 43.2 ± 38.8 mm3 to 0.7 ± 4.1 mm3 (p < .05 for both), respectively. The complication rates and recurrence rates did not differ between the LA group (2.8% [1 of 36] and 5.6% [2 of 36]) and the surgical group (6.7% [3 of 45] and 6.7% [3 of 45]) (p > .05 for both). No distant metastasis occurred in the either group during the follow-up period. Conclusions: Compared with hemithyroidectomy with unilateral central neck dissection, ultrasound-guided LA was also a safe and effective therapy for treating solitary PTMC, and it may be considered as a treatment alternative for patients who are ineligible or refusal to undergo surgery.


Assuntos
Carcinoma Papilar/cirurgia , Terapia a Laser , Neoplasias da Glândula Tireoide/cirurgia , Tireoidectomia , Ultrassonografia de Intervenção , Adulto , Carcinoma Papilar/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Resultado do Tratamento
20.
World J Surg ; 43(4): 1029-1037, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30536023

RESUMO

BACKGROUND: Our purpose is to assess the effectiveness and safety of ultrasound-guided percutaneous microwave ablation (MWA) for lymph node metastases (LNMs) from papillary thyroid carcinomas (PTC). METHODS: In total, 14 patients with recurrent PTC were enrolled in this retrospective study. The vascularity within the ablation zone was evaluated by contrast-enhanced ultrasonography (CEUS) after MWA. Patients were followed up with measurement of the size and volume of tumor, serum thyroglobulin, and clinical evaluation at 7 days, 1, 3, 6 months, and every 6 months thereafter. RESULTS: Twenty-one LNMs were confirmed by biopsy and successfully treated by MWA in a single session. No incomplete ablation was detected by CEUS after treatment. The average largest diameter and volume of the tumors were reduced from 10.1 ± 4.7 mm (range, 3.1-20.0 mm) and 291.9 ± 255.6 mm3 (range, 11.6-766.6 mm3) to 0.9 ± 1.6 mm (range, 0-4.1 mm; p < 0.05) and 4.0 ± 9.0 mm3 (range, 0-31.6 mm3; p < 0.05) at the final follow-up. Neither progression of treated tumors nor newly suspicious LNMs could be detected after treatment. The overall complication rate was 7.1% (1/14). CONCLUSIONS: Ultrasound-guided MWA can effectively control LNMs from PTC, but it is less safe for tumors in the central compartment. MWA may become an alternative therapy in selected PTC patients, who were ineligible or refused to undergo repeated neck explorations.


Assuntos
Carcinoma Papilar/cirurgia , Metástase Linfática , Micro-Ondas/uso terapêutico , Ablação por Radiofrequência , Câncer Papilífero da Tireoide/patologia , Neoplasias da Glândula Tireoide/patologia , Adulto , Carcinoma Papilar/secundário , Meios de Contraste , Feminino , Humanos , Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Masculino , Micro-Ondas/efeitos adversos , Pessoa de Meia-Idade , Ablação por Radiofrequência/efeitos adversos , Estudos Retrospectivos , Tireoglobulina/sangue , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa