Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Arthroplasty ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38823520

RESUMO

BACKGROUND: Modular reconstruction systems based on porous tantalum (PT) prosthetic components have been increasingly used for the treatment of complex acetabular bone defects in revision total hip arthroplasty. We report a novel technique that applies a revision cup as a "super-augment" to form a "double-cup" construct for Paprosky type III defects. METHODS: A retrospective review was conducted on revision total hip arthroplasty cases, comparing those treated with double-cup constructs (DC group, n = 48) to those treated with PT shells and augments (PT group, n = 48). All procedures were performed at the same institute between 2017 and 2022. Clinical outcome evaluation utilized the Harris Hip Score, Oxford Hip Score, and the 36-Item Short Form Survey. Preoperative and postoperative radiographic assessments measured hip center of rotation (COR) position and leg length discrepancy. Additionally, postoperative complications and implant survivorship were monitored during the follow-up period. RESULTS: The clinical outcomes improved substantially in both groups, which showed no significant difference in the Harris Hip Score (P = .786), the Oxford Hip Score (P = .570), and the 36-Item Short Form Survey (P = .691). Compared to the PT group, the reconstruction COR was significantly closer to the anatomic COR (vertical distance: 2.630 versus 7.355 mm, P = .0034; horizontal distance: 1.881 versus -6.413 mm, P < .0001) in Paprosky 3B type defects. Additionally, postoperative leg length discrepancy was less in the DC group (-8.252 versus -1.821 mm, P = .0008). Dislocation was the main complication in the DC group, and only 1 patient received re-revision due to repeated dislocation. The cumulative survival rate of the DC group (100%; 95% confidence interval 100) was better than the PT group (83.4%; 95% confidence interval 70.5 to 98.6) when re-revisions for aseptic loosening were the endpoint (P = .046). CONCLUSIONS: The DC is a reliable revision technique for the reconstruction of Paprosky type III bone defects. Although dislocation remains challenging, the biomechanically superior restoration achieved by this technique lowers the risk of aseptic loosening.

2.
World J Clin Cases ; 10(2): 412-425, 2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35097066

RESUMO

The quadrilateral plate (QP) is an essential structure of the inner wall of the acetabulum, an important weight-bearing joint of the human body, which is often involved in acetabular fractures. The operative exposure, reduction and fixation of QP fractures have always been the difficulties in orthopedics due to the special morphological structure and anatomical features of the QP. Fortunately, there have been many effective methods and instruments developed for QP exposure, reduction and fixation by virtue of the combined efforts of numerous orthopedists. At the same time, each method presents with its own advantages and disadvantages, resulting in different prognoses. It is necessary to have a thorough understanding of the anatomy, radiology and fixation techniques of the QP in terms of patient prognosis optimization. In this paper, the anatomical features, definition and classification of QP, operative approach selection, implant internal fixation methods and efficacy were reviewed.

3.
World J Clin Cases ; 8(20): 4743-4752, 2020 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-33195642

RESUMO

BACKGROUND: Different external skeletal fixators have been widely used in preoperative traction of high-energy tibial fractures prior to a definitive surgical treatment. However, the early complications associated with this staged treatment for traction and soft tissue injury recovery have rarely been discussed. AIM: To analyze the early complications associated with preoperative external traction fixation in the staged treatment of tibial fractures. METHODS: A total of 402 patients with high-energy tibial fractures treated using preoperative external traction fixation at a Level 1 trauma center from 2014 to 2018 were enrolled in this retrospective study. Data regarding the demographic information, Tscherne soft tissue injury, fracture site, entry point placement, and duration of traction were recorded. Procedure-related complications such as movement and sensation disorder, vessel injury, discharge, infection, loosening, and iatrogenic fractures were analyzed. RESULTS: The mean patient age was 42.5 (18-71) years, and the mean duration of traction was 7.5 (0-26) d. In total, 19 (4.7%) patients presented with procedure-related complications, including technique-associated complications in 6 patients and nursing-associated complications in 13. Differences in the incidence of complications with respect to sex, affected side, soft tissue injury classification, and fracture sites were not observed. However, the number of complications due to hammer insertion was significantly reduced than those due to drill insertions (2.9% vs 7.4%). CONCLUSION: We found a low incidence of early complications related to the fixation. Furthermore, the complications were not significantly associated with the severity of the soft tissue injury and fracture site. Although relatively rough and more likely to cause pain, the number of complications associated with hammer insertion was significantly smaller than that of complications associated with drill insertion.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa