Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Hyperthermia ; 41(1): 2405105, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39307528

RESUMO

INTRODUCTION: This study evaluated the performance of magnetic resonance thermometry (MRT) during deep-regional hyperthermia (HT) in pelvic and lower-extremity soft-tissue sarcomas. MATERIALS AND METHODS: 17 pelvic (45 treatments) and 16 lower-extremity (42 treatments) patients underwent standard regional HT and chemotherapy. Pairs of double-echo gradient-echo scans were acquired during the MR protocol 1.4 s apart. For each pair, precision was quantified using phase data from both echoes ('dual-echo') or only one ('single-echo') in- or excluding body fat pixels in the field drift correction region of interest. The precision of each method was compared to that of the MRT approach using a built-in clinical software tool (SigmaVision). Accuracy was assessed in three lower-extremity patients (six treatments) using interstitial temperature probes. The Jaccard coefficient quantified pretreatment motion; receiver operating characteristic analysis assessed its predictability for acceptable precision (<1 °C) during HT. RESULTS: Compared to the built-in dual-echo approach, single-echo thermometry improved the mean temporal precision from 1.32 ± 0.40 °C to 1.07 ± 0.34 °C (pelvis) and from 0.99 ± 0.28 °C to 0.76 ± 0.23 °C (lower extremities). With body fat-based field drift correction, single-echo mean accuracy improved from 1.4 °C to 1.0 °C. Pretreatment bulk motion provided excellent precision prediction with an area under the curve of 0.80-0.86 (pelvis) and 0.81-0.83 (lower extremities), compared to gastrointestinal air motion (0.52-0.58). CONCLUSION: Single-echo MRT exhibited better precision than dual-echo MRT. Body fat-based field-drift correction significantly improved MRT accuracy. Pretreatment bulk motion showed improved prediction of acceptable MRT temporal precision over gastrointestinal air motion.


Assuntos
Hipertermia Induzida , Imageamento por Ressonância Magnética , Sarcoma , Termometria , Humanos , Hipertermia Induzida/métodos , Sarcoma/terapia , Sarcoma/diagnóstico por imagem , Feminino , Masculino , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Termometria/métodos , Adulto , Idoso , Extremidade Inferior/fisiopatologia , Extremidade Inferior/diagnóstico por imagem , Pelve/diagnóstico por imagem , Neoplasias de Tecidos Moles/terapia , Neoplasias de Tecidos Moles/diagnóstico por imagem
2.
Magn Reson Med ; 88(1): 120-132, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35313384

RESUMO

PURPOSE: MR temperature monitoring of mild radiofrequency hyperthermia (RF-HT) of cancer exploits the linear resonance frequency shift of water with temperature. Motion-induced susceptibility distribution changes cause artifacts that we correct here using the total field inversion (TFI) approach. METHODS: The performance of TFI was compared to two background field removal (BFR) methods: Laplacian boundary value (LBV) and projection onto dipole fields (PDF). Data sets with spatial susceptibility change and B0 -drift were simulated, phantom heating experiments were performed, four volunteer data sets at thermoneutral conditions as well as data from one cervical cancer, two sarcoma, and one seroma patients undergoing mild RF-HT were corrected using the proposed methods. RESULTS: Simulations and phantom heating experiments revealed that using BFR or TFI preserves temperature-induced phase change, while removing susceptibility artifacts and B0 -drift. TFI resulted in the least cumulative error for all four volunteers. Temperature probe information from four patient data sets were best depicted by TFI-corrected data in terms of accuracy and precision. TFI also performed best in case of the sarcoma treatment without temperature probe. CONCLUSION: TFI outperforms previously suggested BFR methods in terms of accuracy and robustness. While PDF consistently overestimates susceptibility contribution, and LBV removes valuable pixel information, TFI is more robust and leads to more accurate temperature estimations.


Assuntos
Hipertermia Induzida , Sarcoma , Termometria , Artefatos , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Termometria/métodos
3.
Int J Hyperthermia ; 32(2): 151-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26652664

RESUMO

PURPOSE: This study was designed to assess technical success and complications in patients with high-risk soft tissue sarcomas undergoing CT fluoroscopy-guided closed-tip catheter placement before treatment with combined chemotherapy and regional hyperthermia. MATERIALS AND METHODS: This retrospective study comprised all patients referred for insertion of closed-tip catheters for the introduction of thermometry probes before regional hyperthermia treatment at a single university centre from 2010 to 2015. Catheter placements were performed under local anaesthesia and intermittent CT fluoroscopy guidance. Technical success, complication rate, duration of catheter insertion and dose-length product (DLP) were analysed. Technical success was defined as intratumoural catheter placement suitable for subsequent thermometry. RESULTS: A total of 35 procedures were performed on 35 patients (22 men, 13 women). In 34 out of 35 interventions catheters were inserted successfully; in one patient catheter placement was not feasible. No intra-interventional complications occurred. In six patients post-interventional complications were observed - two major (one abscess formation and one severe catheter dislocation) and four minor complications. Technical failure was observed in 11.4% of patients, especially catheter kinking. A total of 55 catheters were placed, with a mean number of 1.7 ± 0.7 per patient. Mean total DLP was 723.2 ± 355.9 mGy*cm. CONCLUSION: CT fluoroscopy-guided closed-tip catheter placement into high-risk soft tissue sarcomas was characterised by high technical success and relatively low complication rate. While major complications were rarely observed, catheter-kinking preventing successful thermometry represented the most frequent technical failure.


Assuntos
Cateterismo/métodos , Sarcoma , Neoplasias de Tecidos Moles , Adulto , Idoso , Cateterismo/efeitos adversos , Feminino , Fluoroscopia , Humanos , Hipertermia Induzida , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Sarcoma/diagnóstico por imagem , Sarcoma/terapia , Neoplasias de Tecidos Moles/diagnóstico por imagem , Neoplasias de Tecidos Moles/terapia , Termometria , Tomografia Computadorizada por Raios X , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa