Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 278
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 45(8): 613-625, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38036414

RESUMO

BACKGROUND AND AIMS: HeartMate 3 (HM3) is a fully magnetically levitated continuous flow left ventricular assist device, which received CE marking in 2015. The ELEVATE Registry was initiated to collect real-world outcomes in patients treated with HM3 post-CE Mark approval. METHODS: A total of 540 subjects implanted at 26 centres between March 2015 and February 2017 were included in this registry. Of these, 463 received the device as a primary implant (primary implant cohort, PIC), 19 as a pump exchange (pump exchange cohort), and in 58 patients, only anonymized survival data were collected (anonymized cohort, AC). Patients in the PIC contributed to the baseline demographics, survival, adverse events, quality of life (QoL) (EuroQoL-5 Dimensions-5 Levels visual analogue scale), and functional capacity (6 min walk distance) assessments, while patients in the AC contributed only to survival. RESULTS: Primary implant cohort patients had a mean age of 56 years and were predominantly male (89%) with 48% ischaemic aetiology. The majority of subjects was designated bridge to transplant (66%) and had INTERMACS Profiles 1-3 (70%). At baseline, the subjects had poor functional capacity (104 ± 140 m) and impaired QoL (35 ± 19 points). The overall survival rate of the PIC was 63.3% and survival free of stroke was 58.1% at 5 years. Significant improvements in functional capacity and QoL were observed and maintained for 5 years (301 ± 131 m and 64 ± 20 points, respectively). CONCLUSIONS: Real-world data from the ELEVATE registry demonstrate an overall survival rate for primary implants of 63.3%. In the PIC, reductions in adverse events for patients in the extended follow-up and improved QoL and functional capacity were observed at 5 years in this patient population with advanced heart failure.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Coração Auxiliar/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Estudos Prospectivos , Sistema de Registros
2.
J Endovasc Ther ; : 15266028241235876, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528650

RESUMO

CLINICAL IMPACT: On needs-based ex vivo monitoring of implantable devices or tissues/organs in cardiovascular simulators provides new insights and paves new paths for device prototypes. The insights gained could not only support the needs of patients, but also inform engineers, scientists and clinicians about undiscovered aspects of diseases (during routine monitoring). We analyze seminal and current work and highlight a variety of opportunities for developing preclinical tools that would improve strategies for future implantable devices. Holistically, mock circulation loop studies can bridge the gap between in vivo and in vitro approaches, as well as clinical and laboratory settings, in a mutually beneficial manner.

3.
Artif Organs ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38803239

RESUMO

BACKGROUND: Stroke after durable left ventricular assist device (d-LVAD) implantation portends high mortality. The incidence of ischemic and hemorrhagic stroke and the impact on stroke outcomes of temporary mechanical circulatory support (tMCS) management among patients requiring bridge to d-LVAD with micro-axial flow-pump (mAFP, Abiomed) is unsettled. METHODS: Consecutive patients, who underwent d-LVAD implantation after being bridged with mAFP at 19 institutions, were retrospectively included. The incidence of early ischemic and hemorrhagic stroke after d-LVAD implantation (<60 days) and association of pre-d-LVAD characteristics and peri-procedural management with a specific focus on tMCS strategies were studied. RESULTS: Among 341 patients, who underwent d-LVAD implantation after mAFP implantation (male gender 83.6%, age 58 [48-65] years, mAFP 5.0/5.5 72.4%), the early ischemic stroke incidence was 10.8% and early hemorrhagic stroke 2.9%. The tMCS characteristics (type of mAFP device and access, support duration, upgrade from intra-aortic balloon pump, ECMELLA, ECMELLA at d-LVAD implantation, hemolysis, and bleeding) were not associated with ischemic stroke after d-LVAD implant. Conversely, the device model (mAFP 2.5/CP vs. mAFP 5.0/5.5: HR 5.6, 95%CI 1.4-22.7, p = 0.015), hemolysis on mAFP support (HR 10.5, 95% CI 1.3-85.3, p = 0.028) and ECMELLA at d-LVAD implantation (HR 5.0, 95% CI 1.4-18.7, p = 0.016) were associated with increased risk of hemorrhagic stroke after d-LVAD implantation. Both early ischemic (HR 2.7, 95% CI 1.9-4.5, p < 0.001) and hemorrhagic (HR 3.43, 95% CI 1.49-7.88, p = 0.004) stroke were associated with increased 1-year mortality. CONCLUSIONS: Among patients undergoing d-LVAD implantation following mAFP support, tMCS characteristics do not impact ischemic stroke occurrence, while several factors are associated with hemorrhagic stroke suggesting a proactive treatment target to reduce this complication.

4.
Artif Organs ; 47(8): 1319-1325, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36855905

RESUMO

BACKGROUND: Data on the use and outcome of children on ventricular assist device (VAD) support provided with an implantable cardioverter-defibrillator (ICD) remains poor. METHODS: A retrospective analysis of the EUROMACS database on children supported with VAD < 19 years of age from January 1, 2009 to April 1, 2020. Patients with missing data on status of ICD, missing baseline and/or follow up information were excluded. The primary independent variable of interest was the concomitant presence or absence of an ICD at the time of VAD placement. Kaplan-Meier survival analysis was performed to evaluate survival differences between children on VAD with and without an ICD. RESULTS: Out of 303 patients provided with a VAD, 7% (7♀, 15♂) had an ICD implanted and formed the study group. Median age was 14 years, median weight was 43.5 kg, and median BSA was 1.39. Median Intermacs stage was 2 (range: 1-7). Seventeen patients (77%) were transplanted, 4 (18%) died while on support, and 1 (5%) was weaned from device after myocardial recovery. Median time on support was 68 days compared to 361 days in the control group (p: 0.01). Three patients underwent device exchange due to thrombus formation in the pump. There was no difference in survival between groups (p = 0.342). CONCLUSION: The presence of ICD in pediatric patients supported with a VAD is low (7%). Children on VAD support provided with an ICD do not have a survival benefit compared to children without an ICD.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Criança , Adolescente , Insuficiência Cardíaca/cirurgia , Estudos Retrospectivos , Sistema de Registros , Resultado do Tratamento
5.
Cardiol Young ; 33(12): 2690-2692, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37905342

RESUMO

In utero idiopathic constriction of the arterial duct is a rare condition with only a handful reported cases. Ductal aneurysms with thrombus formations on the other hand are significantly more common. We report a case of a term infant who presented with right heart failure due to premature ductal closure and postnatal severe respiratory distress. Subsequent diagnostics revealed paresis of left laryngeal nerve and obstruction of the left pulmonary artery secondary to a ductal aneurysm. Consequently, surgical intervention was considered necessary. Post-operatively, right ventricular function and hoarseness resolved slowly.


Assuntos
Permeabilidade do Canal Arterial , Canal Arterial , Insuficiência Cardíaca , Humanos , Canal Arterial/diagnóstico por imagem , Canal Arterial/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Artéria Pulmonar
6.
JAMA ; 330(22): 2171-2181, 2023 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-37950897

RESUMO

IMPORTANCE: Left ventricular assist devices (LVADs) enhance quality and duration of life in advanced heart failure. The burden of nonsurgical bleeding events is a leading morbidity. Aspirin as an antiplatelet agent is mandated along with vitamin K antagonists (VKAs) with continuous-flow LVADs without conclusive evidence of efficacy and safety. OBJECTIVE: To determine whether excluding aspirin as part of the antithrombotic regimen with a fully magnetically levitated LVAD is safe and decreases bleeding. DESIGN, SETTING, and PARTICIPANTS: This international, randomized, double-blind, placebo-controlled study of aspirin (100 mg/d) vs placebo with VKA therapy in patients with advanced heart failure with an LVAD was conducted across 51 centers with expertise in treating patients with advanced heart failure across 9 countries. The randomized population included 628 patients with advanced heart failure implanted with a fully magnetically levitated LVAD (314 in the placebo group and 314 in the aspirin group), of whom 296 patients in the placebo group and 293 in the aspirin group were in the primary analysis population, which informed the primary end point analysis. The study enrolled patients from July 2020 to September 2022; median follow-up was 14 months. Intervention: Patients were randomized in a 1:1 ratio to receive aspirin (100 mg/d) or placebo in addition to an antithrombotic regimen. MAIN OUTCOMES AND MEASURES: The composite primary end point, assessed for noninferiority (-10% margin) of placebo, was survival free of a major nonsurgical (>14 days after implant) hemocompatibility-related adverse events (including stroke, pump thrombosis, major bleeding, or arterial peripheral thromboembolism) at 12 months. The principal secondary end point was nonsurgical bleeding events. RESULTS: Of the 589 analyzed patients, 77% were men; one-third were Black and 61% were White. More patients were alive and free of hemocompatibility events at 12 months in the placebo group (74%) vs those taking aspirin (68%). Noninferiority of placebo was demonstrated (absolute between-group difference, 6.0% improvement in event-free survival with placebo [lower 1-sided 97.5% CI, -1.6%]; P < .001). Aspirin avoidance was associated with reduced nonsurgical bleeding events (relative risk, 0.66 [95% confidence limit, 0.51-0.85]; P = .002) with no increase in stroke or other thromboembolic events, a finding consistent among diverse subgroups of patient characteristics. CONCLUSIONS AND RELEVANCE: In patients with advanced heart failure treated with a fully magnetically levitated LVAD, avoidance of aspirin as part of an antithrombotic regimen, which includes VKA, is not inferior to a regimen containing aspirin, does not increase thromboembolism risk, and is associated with a reduction in bleeding events. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04069156.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Tromboembolia , Masculino , Humanos , Feminino , Aspirina/efeitos adversos , Coração Auxiliar/efeitos adversos , Fibrinolíticos/efeitos adversos , Método Duplo-Cego , Insuficiência Cardíaca/fisiopatologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/tratamento farmacológico , Inibidores da Agregação Plaquetária/efeitos adversos , Hemorragia/etiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle
7.
J Med Syst ; 47(1): 58, 2023 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-37133553

RESUMO

BACKGROUND: Despite recent design improvements, human factors issues continue to challenge left ventricular assist device (LVAD) therapy. The aim of this study was to evaluate user experience of former non-HeartMate 3 (HM3) LVAD patients post heart transplantation (HTX) and laypersons (LP) with HM3 LVAD peripherals in simulated everyday and emergency scenarios. METHODS: This single center cohort study included untrained HTX and LP. Seven scenarios, including battery exchanges (without alarm, advisory alarm, dim light, consolidated bag), change of power supply, driveline dis-/reconnection and controller exchange were simulated. Subjects' gaze behavior was recorded using eye tracking technology. Success rate, pump-off-time, duration to success (DTS), percental fixation duration per areas of interest and post-scenario-survey results were defined as outcome measures. RESULTS: Thirty subjects completed 210 scenarios, initially solving 82.4% (HTX vs. LP, p = 1.00). Changing power supply revealed highest complexity (DTS = 251 ± 93s, p = 0.76): 26.7% succeeded at first attempt (p = 0.68), 56.7% at second attempt, with significantly more LP failing (p = 0.04), resulting in 10 hazards from driveline disconnections (pump-off-time 2-118s, p = 0.25). Comparison on initial success showed differences in fixation durations for seven areas of interest (p < 0.037). Decreasing DTS during battery exchanges (p < 0.001) indicate high learnability. Exchanging batteries within the bag took longer (median DTS = 75.0 (IQR = 45.0)s, p = 0.09), especially in elderly subjects (r = 0.61, p < 0.001). Subjects with less initial success were more afraid of making mistakes (p = 0.048). CONCLUSION: This eye tracking based human factors study provided insights into user experiences in handling HM3 peripherals. It highlights unintuitive and hazardous characteristics, providing guidance for future user-centered design of LVAD wearables.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Idoso , Insuficiência Cardíaca/cirurgia , Tecnologia de Rastreamento Ocular , Estudos de Coortes , Estudos Retrospectivos
8.
Zentralbl Chir ; 148(3): 284-292, 2023 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-36167311

RESUMO

In recent years, the use of mechanical support for patients with cardiac or circulatory failure has continuously increased, leading to 3,000 ECLS/ECMO (extracorporeal life support/extracorporeal membrane oxygenation) implantations annually in Germany. Due to the lack of guidelines, there is an urgent need for evidence-based recommendations addressing the central aspects of ECLS/ECMO therapy. In July 2015, the generation of a guideline level S3 according to the standards of the Association of the Scientific Medical Societies in Germany (AWMF) was announced by the German Society for Thoracic and Cardiovascular Surgery (GSTCVS). In a well-structured consensus process, involving experts from Germany, Austria and Switzerland, delegated by 16 scientific societies and the patients' representation, the guideline "Use of extracorporeal circulation (ECLS/ECMO) for cardiac and circulatory failure" was created under guidance of the GSTCVS, and published in February 2021. The guideline focuses on clinical aspects of initiation, continuation, weaning and aftercare, herein also addressing structural and economic issues. This article presents an overview on the methodology as well as the final recommendations.


Assuntos
Oxigenação por Membrana Extracorpórea , Choque , Humanos , Sociedades Científicas , Circulação Extracorpórea , Sociedades Médicas , Alemanha
9.
Platelets ; 33(2): 249-256, 2022 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-33760697

RESUMO

Left-ventricular assist devices (LVADs) improve outcomes in end-stage heart failure patients. Two centrifugal-flow LVAD systems are currently approved, HeartMate 3 (HM3) and Medtronic/Heartware HVAD (HVAD). Clinical findings suggest differences in thrombogenicity between both systems. We compared markers of platelet activation and aggregation between HM3 and HVAD. We prospectively included 59 LVAD patients (40 HM3, 19 HVAD). Platelet P-selectin expression, activated glycoprotein (GP) IIb/IIIa and monocyte-platelet aggregates (MPA) were assessed by flow-cytometry. Platelet aggregation was measured by light-transmission aggregometry (LTA) and multiple-electrode aggregometry (MEA). Von-Willebrand factor (VWF) antigen (VWF:Ag), VWF activity (VWF:Ac), and VWF multimer pattern analysis were determined. Soluble P-selectin (sP-selectin) was measured with an enzyme-linked immunoassay. P-selectin, GPIIb/IIIa and MPA levels in vivo and in response to arachidonic acid, adenosine diphosphate, and thrombin receptor activating peptide were similar between HM3 and HVAD (all p > .05). Likewise, agonist-inducible platelet aggregation by LTA and MEA did not differ between HM3 and HVAD (all p > .05). VWF:Ag levels and FVIII:C were similar between both systems (both p > .05), but patients with HVAD had significantly lower VWF:Ac (p = .011) and reduced large VWF multimers (p = .013). Finally, sP-selectin levels were similar in patients with HVAD and HM3 (p = .845). In conclusion, on-treatment platelet activation and aggregation are similar in HM3 and HVAD patients. Potential clinical implications of observed differences in VWF profiles between both LVAD systems need to be addressed in future clinical trials.


Assuntos
Coração Auxiliar/normas , Ativação Plaquetária/fisiologia , Agregação Plaquetária/fisiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
10.
Artif Organs ; 46(6): 1149-1157, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34978722

RESUMO

BACKGROUND: A relation between the left ventricular assist device inflow cannula (IC) malposition and pump thrombus has been reported. This study aimed to investigate if the pump position, derived from chest X-rays in HeartMate 3 (HM3) patients, correlates with neurological dysfunction (ND), ischemic stroke (IS), hemorrhagic stroke (HS) and survival. METHODS: This analysis was performed on routinely acquired X-rays of 42 patients implanted with a HM3 between 2014 and 2017. Device position was quantified in patients with and without ND from frontal and lateral X-rays characterizing the IC and pump in relation to spine, diaphragm or horizontal line. The primary end-point was freedom from stroke and survival one-year after HM3 implantation stratified by pump position. RESULTS: The analysis of X-rays, 33.5 (41.0) days postoperative, revealed a significant smaller IC angle of HM3 patients with ND versus no ND (0.1° ± 14.0° vs. 12.9° ± 10.1°, p = 0.005). Additionally, the IC angle in the frontal view, IS: 4.1 (20.9)° versus no IS: 13.8 (7.5)°, p = 0.004 was significantly smaller for HM3 patients with IS. Using receiver operating characteristics derived cut-off, IC angle <10° provided 75% sensitivity and 100% specificity (C-statistic = 0.85) for predicting IS. Stratified by IC angle, freedom from IS at 12 months was 100% (>10°) and 60% (<10°) respectively (p = 0.002). No significant differences were found in any end-point between patients with and without HS. One-year survival was significantly higher in patients with IC angle >10° versus <10° (100% vs. 71.8%, p = 0.012). CONCLUSIONS: IC malposition derived from standard chest X-rays serves as a risk factor for ND, IS and worse survival in HM3 patients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Trombose , Cânula/efeitos adversos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/complicações , Trombose/etiologia
11.
Artif Organs ; 46(5): 813-826, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34904255

RESUMO

BACKGROUND: We investigated the clinical outcomes after cardiac valvular surgery procedures concomitant (CCPs) with left ventricular assist device (LVAD) implantation compared to propensity score (PS) matched controls using the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) data. METHODS: Between 2006 and 2018, 2760 continuous-flow LVAD patients were identified. Of these, 533 underwent a CCP during the LVAD implant. RESULTS: Cardiopulmonary bypass time (p < 0.001) and time for implant (p < 0.001) were both significantly longer in the LVAD+CCP group. Hospital mortality was comparable between the two groups from the unmatched population (15.7% vs. 14.1%, p = 0.073). Similarly, short-to-mid-term survival was similar in both groups, with 1-year, 3-year, and 5-year survival rates of 67.9%, 48.2%, and 27.7% versus 66.4%, 46.1%, and 26%, respectively (log-rank, p = 0.25). The results were similar in the PS-matched population. Hospital mortality was comparable between the two groups (18.9% vs. 17.4%, p = 0.074). The short-to-mid-term Kaplan-Meier survival analysis was similar for both groups, with 1-year, 3-year, and 5-year survival rates of 63.4%, 49.2%, and 24.7% versus 66.5%, 46%, and 25.1%, respectively (log-rank, p = 0.81). In the unmatched population, LVAD+CCP patients had longer intensive care unit (ICU) stays (p < 0.0001), longer mechanical ventilation time (p = 0.001), a higher rate of temporary right ventricular assist device (RVAD) support (p = 0.033), and a higher rate of renal replacement therapy (n = 35, 6.6% vs. n = 89, 4.0%, p = 0.014). In the PS-matched population, the LVAD+CCP patients had longer ICU stays (p = 0.019) and longer mechanical ventilation time (p = 0.002). CONCLUSIONS: The effect of additive valvular procedures (CCPs) does not seem to affect short-term survival, significantly, based on our registry data analysis. However, the decision to perform CCPs should be balanced with the projected type of surgery and preoperative characteristics. LVAD+CCP patients remain a delicate population and adverse device-related events should be strictly monitored and managed.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
12.
Am J Obstet Gynecol ; 225(2): 189.e1-189.e30, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33662361

RESUMO

BACKGROUND: Postmortem confirmation of prenatally diagnosed congenital heart disease after termination of pregnancy and evaluation of potential cardiac defects after spontaneous fetal or neonatal death are essential. Conventional autopsy rates are decreasing, and 1.5Tesla magnetic resonance imaging has demonstrated limited diagnostic accuracy for postmortem cardiovascular assessment. OBJECTIVE: This study aimed to evaluate the feasibility and image quality of cardiac 3Tesla postmortem magnetic resonance imaging and to assess its diagnostic accuracy in detecting fetal heart defects compared with conventional autopsy. Secondarily, the study aimed to explore whether clinical factors affect the quality of 3Tesla postmortem magnetic resonance imaging. STUDY DESIGN: A total of 222 consecutive fetuses between 12 and 41 weeks' gestation, who underwent 3Tesla postmortem magnetic resonance imaging and conventional autopsy after spontaneous death or termination of pregnancy for fetal malformations, were included. First, 3Tesla postmortem magnetic resonance imaging of each fetus was rated as diagnostic or nondiagnostic for fetal cardiac assessment by 2 independent raters. The image quality of individual cardiac structures was then further evaluated by visual grading analysis. Finally, the presence or absence of a congenital heart defect was assessed by 2 radiologists and compared with autopsy results. RESULTS: Overall, 87.8% of 3Tesla postmortem magnetic resonance imaging examinations were rated as diagnostic for the fetal heart. Diagnostic imaging rates of individual cardiac structures at 3Tesla postmortem magnetic resonance imaging ranged from 85.1% (atrioventricular valves) to 94.6% (pericardium), with an interrater agreement of 0.82 (0.78-0.86). Diagnostic imaging of the fetal aortic arch and the systemic veins at 3Tesla postmortem magnetic resonance imaging was possible from 12+5 weeks' gestation onward in 90.1% and 92.3% of cases, respectively. A total of 55 fetuses (24.8%) had at least 1 cardiac anomaly according to autopsy, 164 (73.9%) had a normal heart, and in 3 fetuses (1.4%), autopsy was nondiagnostic for the heart. Considering all examinations rated as diagnostic, 3Tesla postmortem magnetic resonance imaging provided high diagnostic accuracy for the detection of fetal congenital heart defects with a sensitivity of 87.8%, a specificity of 97.9%, and concordance with autopsy of 95.3%. 3Tesla postmortem magnetic resonance imaging was less accurate in young fetuses (<20 weeks compared with ≥20 weeks; P<.001), in fetuses with low birthweight (≤100 g compared with >100 g; P<.001), in cases after spontaneous fetal death (compared with other modes of death; P=.012), in cases with increasing latency between death and 3Tesla postmortem magnetic resonance imaging (P<.001), and in cases in which there was a high degree of maceration (maceration score of 3 compared with a score from 0 to 2; P=.004). CONCLUSION: Diagnostic 3Tesla postmortem magnetic resonance imaging assessment of the fetal heart is feasible in most fetuses from 12 weeks' gestation onward. In diagnostic images, sensitivity and, particularly, specificity in the detection of congenital heart disease are high compared with conventional autopsy. Owing to its high diagnostic accuracy, we suggest that 3Tesla postmortem magnetic resonance imaging may serve as a suitable imaging modality with which to direct a targeted conventional autopsy when pathology resources are limited or to provide a virtual autopsy when full autopsy is declined by the parents.


Assuntos
Autopsia/métodos , Coração Fetal/diagnóstico por imagem , Feto/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Feminino , Morte Fetal , Coração Fetal/fisiologia , Cardiopatias Congênitas/patologia , Humanos , Recém-Nascido , Masculino , Morte Perinatal , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia Pré-Natal
13.
Artif Organs ; 45(5): 464-472, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33052592

RESUMO

Driveline infections (DLI) are common adverse events in left ventricular assist devices (LVADs), leading to severe complications and readmissions. The study aims to characterize risk factors for DLI readmission 2 years postimplant. This single-center study included 183 LVAD patients (43 HeartMate II [HMII], 29 HeartMate 3 [HM3], 111 HVAD) following hospital discharge between 2013 and 2017. Demographics, clinical parameters, and outcomes were retrospectively analyzed and 12.6% of patients were readmitted for DLI, 14.8% experienced DLI but were treated in the outpatient setting, and 72.7% had no DLI. Mean C-reactive protein (CRP), leukocytes and fibrinogen were higher in patients with DLI readmission (P < .02) than in outpatient DLI and patients without DLI, as early as 60 days before readmission. Freedom from DLI readmission was comparable for HMII and HVAD (98% vs. 87%; HR, 4.52; 95% CI, 0.58-35.02; P = .15) but significantly lower for HM3 (72%; HR, 10.82; 95% CI, 1.26-92.68; P = .03). DLI (HR, 1.001; 95% CI, 0.999-1.002; P = .16) or device type had no effect on mortality. DLI readmission remains a serious problem following LVAD implantation, where CRP, leukocytes, and fibrinogen might serve as risk factors already 60 days before. HM3 patients had a higher risk for DLI readmissions compared to HVAD or HMII, possibly because of device-specific driveline differences.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Adulto , Idoso , Biomarcadores/sangue , Proteína C-Reativa/análise , Feminino , Fibrinogênio/análise , Seguimentos , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente/estatística & dados numéricos , Infecções Relacionadas à Prótese/sangue , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/terapia , Estudos Retrospectivos , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Fatores de Risco
14.
BMC Pediatr ; 21(1): 341, 2021 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-34389009

RESUMO

BACKGROUND: Neonates and small infants with congenital cardiac disease undergoing cardiac surgery represent major challenges facing paediatric anaesthesia and perioperative medicine. AIMS: We here aimed to investigate the success rates in performing ultrasound (US) guided central venous catheter insertion (CVC) in neonates and small infants undergoing cardiac surgery, and to evaluate the practicability and feasibility of thereby using a novel wireless US transducer (WUST). METHODS: Thirty neonates and small infants with a maximum body weight of 10 kg and need for CVC before cardiac surgery were included in this observational trial and were subdivided into two groups according to their weight: < 5 kg and ≥ 5 kg. Cannulation success, failure rate, essential procedure related time periods, and complications were recorded and the clinical utility of the WUST was assessed by a 5-point Likert scale. RESULTS: In total, CVC-insertion was successful in 27 (90%) of the patients and the first attempt was successful in 24 (78%) of patients. Success rates of CVC were 80% < 5 kg and 100% ≥5 kg. Comparing the two groups we found a clear trend towards longer needle insertion time in patients weighing < 5 kg (33 [28-69] vs. 24 [15-37]s, P = .07), whereas, the total time for catheter insertion and the duration of the whole procedure were similar in both groups (199 [167-228] vs. 178 [138-234] and 720[538-818] vs. 660 [562-833]s. In total, we report 3 (10%) cases of local hematoma as procedure-related complications. Assessments of the WUST revealed very good survey results for all parameters of practicability and handling (all ratings between 4.5 and 5.0). CONCLUSION: Although difficulties in CVC-placement seem to relate to vessel size and patient's weight, US guided CVC-insertion represents a valuable, fast, and safe intervention in neonates and small children undergoing cardiac surgery. Using the WUST is feasible for this clinical application and may aid in efforts aiming to optimize perioperative care. TRIAL REGISTRATION: Wireless US-guided CVC placement in infants; Clinicaltrials.gov: NCT04597021 ; Date of Registration: 21October, 2020; retrospectively registered.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cateteres Venosos Centrais , Criança , Humanos , Lactente , Recém-Nascido , Projetos Piloto , Estudos Prospectivos , Transdutores , Ultrassonografia de Intervenção
15.
J Card Surg ; 36(4): 1344-1351, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33547707

RESUMO

BACKGROUND: The aim of this study was to evaluate the impact of the surgical approach on the postoperative outcome in patients who underwent left ventricular assist device (LVAD) implantation after having received veno-arterial extracorporeal life support (va-ECLS) using data from a European registry (ECLS-VAD). Five hundred and thirty-one patients were included. METHODS: A propensity score-adjusted outcome analysis was performed, resulting in 324 patients in the full sternotomy (FS) group and 39 in the less invasive surgery (LIS) group. RESULTS: The surgery lasted in median 236 min in the FS group versus 263 min in the LIS group (p = 0.289). The median chest tube output during the first 24 h was similar in both groups. Patients who underwent implantation with an FS required more blood products during the first 24 postoperative hours (median 16 vs. 12, p = 0.033). The incidence of revision due to bleeding was also higher (35.5 vs. 15.4%, p = 0.016). A temporary postoperative right ventricular assist device was necessary in 45.1 (FS) versus 23.1% (LIS) of patients, respectively (p = 0.067). No stroke occurred in the LIS group during the first 30 days after surgery (7.4% in the FS group). The incidence of stroke and of renal, hepatic, and respiratory failure during the follow-up was similar in both groups. The 30-day and one-year survival were similar in both groups. CONCLUSION: LIS for implantation of a durable LVAD in patients on va-ECLS implanted for cardiogenic shock is associated with less revision due to bleeding, less administration of blood products and absence of perioperative stroke, with no impact on survival.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/cirurgia , Humanos , Implantação de Prótese , Estudos Retrospectivos , Resultado do Tratamento
16.
Eur Heart J ; 41(39): 3801-3809, 2020 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-33107561

RESUMO

AIMS: The ELEVATE Registry was designed to study long-term outcomes with the Heartmate 3 (HM3), a fully magnetically levitated centrifugal ventricular assist device, in a real-world population following CE-mark approval. METHODS AND RESULTS: A total of 540 patients, implanted in Europe and the Middle East were followed in ELEVATE. The registry included 463 patients receiving the HM3 as primary implant (Primary Implant Cohort), 19 patients underwent a pump upgrade from another device (Pump Exchange Cohort) and 58 patients who had experienced an outcome before having the possibility to sign the Informed Consent, for which only outcome data were collected (Anonymized Cohort). Data collection included demographics, survival, adverse events, EQ-5D Visual Analog Score quality of life (EQ-5D VAS QOL) questionnaire, and 6-min walk distance (6MWD). Mean age was 55.6 ± 11.7 years (89% male, 48% ischaemic cardiomyopathy). Seventy per cent of patients were in INTERMACS Profile 1-3 and 12.7% were on temporary mechanical circulatory support. Primary Implant Cohort survival was 83% after 2 years. In the Powered by Editorial Manager® and ProduXion Manager® from Aries Systems Corporation Primary Implant Cohort, strokes were observed in 10.2%, gastrointestinal bleedings in 9.7%, pump thrombosis in 1.5%, and outflow graft twists in 3.5%. Heartmate 3 implantation resulted in a significant and sustained improvement of functional capacity and QOL. CONCLUSION: In a real-world population, cohort implanted with the HM3 left ventricular assist device we demonstrate good long-term survival, sustained improvement of functional capacity, and low rates of adverse events (including pump thrombosis). CLINICALTRIALS.GOV IDENTIFIER: NCT02497950.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Idoso , Europa (Continente) , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Oriente Médio , Estudos Prospectivos , Qualidade de Vida , Sistema de Registros , Resultado do Tratamento
17.
Anaesthesist ; 70(11): 942-950, 2021 11.
Artigo em Alemão | MEDLINE | ID: mdl-34665266

RESUMO

In Germany, a remarkable increase regarding the usage of extracorporeal membrane oxygenation (ECMO) and extracorporeal life support (ECLS) systems has been observed in recent years with approximately 3000 ECLS/ECMO implantations annually since 2015. Despite the widespread use of ECLS/ECMO, evidence-based recommendations or guidelines are still lacking regarding indications, contraindications, limitations and management of ECMO/ECLS patients. Therefore in 2015, the German Society of Thoracic and Cardiovascular Surgery (GSTCVS) registered the multidisciplinary S3 guideline "Use of extracorporeal circulation (ECLS/ECMO) for cardiac and circulatory failure" to develop evidence-based recommendations for ECMO/ECLS systems according to the requirements of the Association of the Scientific Medical Societies in Germany (AWMF). Although the clinical application of ECMO/ECLS represents the main focus, the presented guideline also addresses structural and economic issues. Experts from 17 German, Austrian and Swiss scientific societies and a patients' organization, guided by the GSTCVS, completed the project in February 2021. In this report, we present a summary of the methodological concept and tables displaying the recommendations for each chapter of the guideline.


Assuntos
Oxigenação por Membrana Extracorpórea , Choque , Circulação Extracorpórea , Alemanha , Humanos , Sistemas de Manutenção da Vida
18.
Medicina (Kaunas) ; 58(1)2021 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-35056351

RESUMO

Background and objectives: Extracorporeal life support (ECLS) is a widely accepted and effective strategy for use in patients presenting with refractory cardiogenic shock. Implantation in awake and non-intubated patients allows for optimized evaluation of further therapy options while avoiding potential side effects associated with the need for sedation and intubation. The aim of the study was the assessment of safety and feasibility of awake ECLS implementation and of outcomes in patients treated with this concept. Materials and Methods: We retrospectively reviewed the concept of awake ECLS implantation in 16 consecutive patients (mean age 58 ± 8 years; male: 88%; ischemic cardiomyopathy: 50%) from 02/2017 to 01/2021. Study endpoints were survival to weaning or bridging to durable support or organ replacement and development of end-organ function and hemodynamic parameters on ECLS. Results: Fourteen patients (88%) were able to be successfully transitioned to definite therapy options. ECLS support stabilized end-organ function, led to a decrease in mean lactate levels (5.3 ± 3.7 mmol/L at baseline to 1.9 ± 1.3 mmol/L 12 h after ECLS start; p = 0.01) and improved hemodynamics (median central venous pressure 20 ± 5 mmHg vs. 10 ± 2 mmHg, p = 0.001) over a median duration of two days (1-8 days IQR). Two patients (13%) died on ECLS support due to multi-organ dysfunction syndrome. Survival to discharge of initially successfully bridged or weaned patients was 64%. Conclusions: Awake ECLS implantation is feasible and safe with the key advantage of omitting or delaying general anesthesia and intubation, with their associated risks in cardiogenic-shock patients, facilitating further decision making.


Assuntos
Oxigenação por Membrana Extracorpórea , Choque Cardiogênico , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Choque Cardiogênico/terapia , Resultado do Tratamento , Vigília
19.
J Card Fail ; 26(7): 580-587, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32417377

RESUMO

BACKGROUND: In patients with a continuous-flow left ventricular assist device, preimplant predictors of poor physical performance are not well-described. We aimed to identify predictors of inability to walk more than 300 m on 6-minute walk test (6MWT) 6 months after HeartMate 3 implantation. METHODS AND RESULTS: Using data from the European Registry of Patients Implanted With a Full Magnetically Levitated LVAD, patients with available 6MWT at 6 months after implantation were included (N = 194) and grouped according to 6MWT distance (6MWD) of >300 m (n = 150) or 6MWD of <300 m (n = 44). Patients walking <300 m were older (60 ± 10 vs 52 ± 12 years; P < .001), more often New York Heart Association functional class IV (63% vs 42%; P = .03), and more often had type 2 diabetes (43% vs 17%; P < .001) at implantation. Atrial fibrillation was seen in 57% in those with a 6MWT of <300 m vs 31% in those walking longer (P < .002). Further, hemoglobin and estimated glomerular filtration rate was lower in those walking <300 m (both P < .01). In multivariable regression analysis, independent predictors of a 6MWD of <300 m were: atrial fibrillation (odds ratio [OR], 3.22; 95% confidence interval [CI], 1.12-8.67), older age (OR for 10-year increment, 2.81; 95% CI, 1.55-5.07), New York Heart Association functional class IV (OR, 3.37; 95% CI, 1.27-8.98), and Interagency Registry for Mechanically Assisted Circulatory Support profile 1 or 2 (OR, 6.53; 95% CI, 1.92-22.19). CONCLUSIONS: Six months after HeartMate 3 implantation, 77% of patients walked >300 meters in 6 minutes. Apart from age and measures of heart failure severity, atrial fibrillation at implantation is an independent predictor of low 6MWD at 6 months after implantation.


Assuntos
Diabetes Mellitus Tipo 2 , Insuficiência Cardíaca , Coração Auxiliar , Idoso , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Sistema de Registros , Resultado do Tratamento
20.
Pediatr Transplant ; 24(3): e13679, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32198844

RESUMO

Optimal management of pediatric cardiac donors is essential in order to maximize donor heart utilization and minimize the rate of discarded organs. This review was performed after a systematic literature review and gives a detailed overview on current practices and guidelines. The review focuses on optimal monitoring of pediatric donors, donor workup, hormonal replacement, and obliterating the adverse effects of brain death. The current evidence on catecholamine support and thyroid hormone replacement is also discussed. Recognizing and addressing this shall help in a standardized approach toward donor management and optimal utilization of pediatric heart donors organs.


Assuntos
Transplante de Coração , Doadores de Tecidos , Coleta de Tecidos e Órgãos/métodos , Obtenção de Tecidos e Órgãos/métodos , Adolescente , Morte Encefálica , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Guias de Prática Clínica como Assunto , Padrões de Prática Médica
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa