RESUMO
Background Photon-counting detector (PCD) CT provides comprehensive spectral data with every acquisition, but studies evaluating myocardial extracellular volume (ECV) quantification with use of PCD CT compared with an MRI reference remain lacking. Purpose To compare ECV quantification for myocardial tissue characterization between a first-generation PCD CT system and cardiac MRI. Materials and Methods In this single-center prospective study, adults without contraindication to iodine-based contrast media underwent same-day cardiac PCD CT and MRI with native and postcontrast T1 mapping and late gadolinium enhancement for various clinical indications for cardiac MRI (the reference standard) between July 2021 and January 2022. Global and midventricular ECV were assessed with use of three methods: single-energy PCD CT, dual-energy PCD CT, and MRI T1 mapping. Quantitative comparisons among all techniques were performed. Correlation and reliability between different methods of ECV quantification were assessed with use of the Pearson correlation coefficient (r) and the intraclass correlation coefficient. Results The final sample included 29 study participants (mean age ± SD, 54 years ± 17; 15 men). There was a strong correlation of ECV between dual- and single-energy PCD CT (r = 0.91, P < .001). Radiation dose was 40% lower with dual-energy versus single-energy PCD CT (volume CT dose index, 10.1 mGy vs 16.8 mGy, respectively; P < .001). In comparison with MRI, dual-energy PCD CT showed strong correlation (r = 0.82 and 0.91, both P < .001) and good to excellent reliability (intraclass correlation coefficients, 0.81 and 0.90) for midventricular and global ECV quantification, but it overestimated ECV by approximately 2%. Single-energy PCD CT showed similar relationship with MRI but underestimated ECV by 3%. Conclusion Myocardial tissue characterization with photon-counting detector CT-based quantitative extracellular volume analysis showed a strong correlation to MRI. © RSNA, 2023 Supplemental material is available for this article.
Assuntos
Meios de Contraste , Gadolínio , Masculino , Adulto , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodosRESUMO
OBJECTIVES: To assess the impact of scan modes and reconstruction kernels using a novel dual-source photon-counting detector CT (PCD-CT) on lumen visibility and sharpness of different stent sizes. METHODS: A phantom containing six balloon-expandable stents (2.5 to 9 mm diameter) in silicone tubing was scanned on a PCD-CT with standard (0.6 mm and 0.4 mm thicknesses) and ultra-high-resolution (0.2 mm thickness) modes. With the use of increasing contrast medium concentrations, densities of 0, 200, 400, and 600 HU were achieved. Standard-resolution scans were reconstructed using increasing sharpness kernels, using both polyenergetic quantitative soft tissue "conventional" ((Qr40c(0.6 mm), Qr40c(0.4 mm), Qr72c(0.2 mm)) and vascular (Bv) virtual monoenergetic reconstructions (Bv44m(0.4 mm), Bv60m(0.4 mm)) at 70 keV. In-stent lumen visibility, sharpness (max. ΔHU of the stent measured in profile plots), and in-stent noise (standard deviation of HU) were measured. RESULTS: In-stent lumen visibility was highest for Qr72c(0.2 mm) (86.5 ± 2.8% to 88.3 ± 2.6%) and in Bv60m(0.4 mm) reconstructions (77.3 ± 2.9 to 82.7 ± 2.5%). Lumen visibility was lowest in the smallest stent (2.5 mm) ranging from 54.1% in Qr40c(0.6 mm) to 74.1% in Qr72c(0.2 mm) and highest in the largest stent (9 mm) ranging from 93.8% in Qr40c(0.6 mm) to 99.1% in the Qr72c(0.2 mm) series. Lumen visibility decreased by 2.1% for every 200-HU increase in lumen attenuation. Max. ΔHU between stents and stent lumen was highest in Qr72c(0.2 mm) (ΔHU 892 ± 504 to 1526 ± 517) and Bv60m(0.4 mm) series (ΔHU 480 ± 357 to 1030 ± 344). Improvement of lumen visibility and sharpness in UHR and Bv60m(0.4 mm) series was strongest in smaller stent sizes. CONCLUSION: UHR acquisition mode and sharp reconstruction kernels on a novel PCD-CT system significantly improve in-stent lumen visibility and sharpness-especially for smaller stent sizes. KEY POINTS: ⢠In-stent lumen visibility and sharpness of stents significantly improve using sharp reconstruction kernels (Bv60) and ultra-high-resolution mode in photon-counting detector computed tomography. ⢠The observed improvement of stent-lumen visibility was highest in smaller stent sizes.
Assuntos
Stents , Tomografia Computadorizada por Raios X , Humanos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Imagens de FantasmasRESUMO
BACKGROUND: Radiomics is not yet used in clinical practice due to concerns regarding its susceptibility to technical factors. We aimed to assess the stability and interscan and interreader reproducibility of myocardial radiomic features between energy-integrating detector computed tomography (EID-CT) and photon-counting detector CT (PCD-CT) in patients undergoing coronary CT angiography (CCTA) on both systems. METHODS: Consecutive patients undergoing clinically indicated CCTA on an EID-CT were prospectively enrolled for a PCD-CT CCTA within 30 days. Virtual monoenergetic images (VMI) at various keV levels and polychromatic images (T3D) were generated for PCD-CT, with image reconstruction parameters standardized between scans. Two readers performed myocardial segmentation and 110 radiomic features were compared intraindividually between EID-CT and PDC-CT series. The agreement of parameters was assessed using the intraclass correlation coefficient and paired t-test for the stability of the parameters. RESULTS: Eighteen patients (15 males) aged 67.6 ± 9.7 years (mean ± standard deviation) were included. Besides polychromatic PCD-CT reconstructions, 60- and 70-keV VMIs showed the highest feature stability compared to EID-CT (96%, 90%, and 92%, respectively). The interscan reproducibility of features was moderate even in the most favorable comparisons (median ICC 0.50 [interquartile range 0.20-0.60] for T3D; 0.56 [0.33-0.74] for 60 keV; 0.50 [0.36-0.62] for 70 keV). Interreader reproducibility was excellent for the PCD-CT series and good for EID-CT segmentations. CONCLUSION: Most myocardial radiomic features remain stable between EID-CT and PCD-CT. While features demonstrated moderate reproducibility between scanners, technological advances associated with PCD-CT may lead to greater reproducibility, potentially expediting future standardization efforts. RELEVANCE STATEMENT: While the use of PCD-CT may facilitate reduced interreader variability in radiomics analysis, the observed interscanner variations in comparison to EID-CT should be taken into account in future research, with efforts being made to minimize their impact in future radiomics studies. KEY POINTS: Most myocardial radiomic features resulted in being stable between EID-CT and PCD-CT on certain VMIs. The reproducibility of parameters between detector technologies was limited. PCD-CT improved interreader reproducibility of myocardial radiomic features.
Assuntos
Angiografia por Tomografia Computadorizada , Humanos , Masculino , Feminino , Idoso , Reprodutibilidade dos Testes , Angiografia por Tomografia Computadorizada/métodos , Estudos Prospectivos , Fótons , Angiografia Coronária/métodos , Pessoa de Meia-Idade , RadiômicaRESUMO
RATIONALE AND OBJECTIVES: Coronary CT angiography (CCTA) has recently been established as a first-line test in patients with suspected coronary artery disease (CAD). Due to the increased use of CCTA, strategies to reduce radiation and contrast medium (CM) exposure are of high importance. The aim of this study was to evaluate the performance of automated tube voltage selection (ATVS)-adapted CM injection protocol for CCTA compared to a clinically established triphasic injection protocol in terms of image quality, radiation exposure, and CM administration MATERIAL AND METHODS: Patients undergoing clinically indicated CCTA were prospectively enrolled from July 2021 to July 2023. Patients underwent CCTA using a modified triphasic CM injection protocol tailored to the tube voltage by the ATVS algorithm, in a range of 70 to 130 kV with a 10 kV interval. The injection protocol consisted of two phases of mixed CM and saline boluses with different proportions to assure a voltage-specific iodine delivery rate, followed by a third phase of saline flush. This cohort was compared to a control group identified retrospectively and scanned on the same CT system but with a standard triphasic CM protocol. Radiation and contrast dose, subjective and objective image quality (contrast-to-noise-ratio [CNR] and signal-to-noise-ratio [SNR]) were compared between the two groups. RESULTS: The final population consisted of 120 prospective patients matched with 120 retrospective controls, with 20 patients in each kV group. The 120 kV group was excluded from the statistical analysis due to insufficient sample size. A significant CM reduction was achieved in the prospective group overall (46.0 [IQR 37.0-52.0] vs. 51.3 [IQR 40.1-73.0] mL, p < 0.001) and at all kV levels too (all pairwise p < 0.001). There were no significant differences in radiation dose (6.13 ± 4.88 vs. 5.97 ± 5.51 mSv, p = 0.81), subjective image quality (median score of 4 [3-5] vs. 4 [3-5], p = 0.40), CNR, and SNR in the aorta and the left anterior descending coronary artery (all p > 0.05). CONCLUSION: ATVS-adapted CM injection protocol allows for diagnostic quality CCTA with reduced CM volume while maintaining similar radiation exposure, subjective and objective image quality.
Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Angiografia Coronária , Doença da Artéria Coronariana , Doses de Radiação , Humanos , Meios de Contraste/administração & dosagem , Angiografia por Tomografia Computadorizada/métodos , Feminino , Masculino , Angiografia Coronária/métodos , Estudos Prospectivos , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos de Casos e Controles , Idoso , Exposição à Radiação/prevenção & controle , Exposição à Radiação/análise , AlgoritmosRESUMO
This study evaluated a deep neural network (DNN) algorithm for automated aortic diameter quantification and aortic dissection detection in chest computed tomography (CT). A total of 100 patients (median age: 67.0 [interquartile range 55.3/73.0] years; 60.0% male) with aortic aneurysm who underwent non-enhanced and contrast-enhanced electrocardiogram-gated chest CT were evaluated. All the DNN measurements were compared to manual assessment, overall and between the following subgroups: (1) ascending (AA) vs. descending aorta (DA); (2) non-obese vs. obese; (3) without vs. with aortic repair; (4) without vs. with aortic dissection. Furthermore, the presence of aortic dissection was determined (yes/no decision). The automated and manual diameters differed significantly (p < 0.05) but showed excellent correlation and agreement (r = 0.89; ICC = 0.94). The automated and manual values were similar in the AA group but significantly different in the DA group (p < 0.05), similar in obese but significantly different in non-obese patients (p < 0.05) and similar in patients without aortic repair or dissection but significantly different in cases with such pathological conditions (p < 0.05). However, in all the subgroups, the automated diameters showed strong correlation and agreement with the manual values (r > 0.84; ICC > 0.9). The accuracy, sensitivity and specificity of DNN-based aortic dissection detection were 92.1%, 88.1% and 95.7%, respectively. This DNN-based algorithm enabled accurate quantification of the largest aortic diameter and detection of aortic dissection in a heterogenous patient population with various aortic pathologies. This has the potential to enhance radiologists' efficiency in clinical practice.
RESUMO
BACKGROUND: Coronary computed tomography angiography (CCTA)-based fractional flow reserve (CT-FFR) allows for noninvasive determination of the functional severity of anatomic lesions in patients with coronary artery disease. The aim of this study was to intra-individually compare CT-FFR between photon-counting detector (PCD) and conventional energy-integrating detector (EID) CT systems. METHODS: In this single-center prospective study, subjects who underwent clinically indicated CCTA on an EID-CT system were recruited for a research CCTA on PCD-CT within 30 days. Image reconstruction settings were matched as closely as possible between EID-CT (Bv36 kernel, iterative reconstruction strength level 3, slice thickness 0.5 mm) and PCD-CT (Bv36 kernel, quantum iterative reconstruction level 3, virtual monoenergetic level 55 keV, slice thickness 0.6 mm). CT-FFR was measured semi-automatically using a prototype on-site machine learning algorithm by two readers. CT-FFR analysis was performed per-patient and per-vessel, and a CT-FFR ≤ 0.75 was considered hemodynamically significant. RESULTS: A total of 22 patients (63.3 ± 9.2 years; 7 women) were included. Median time between EID-CT and PCD-CT was 5.5 days. Comparison of CT-FFR values showed no significant difference and strong agreement between EID-CT and PCD-CT in the per-vessel analysis (0.88 [0.74-0.94] vs. 0.87 [0.76-0.93], P = 0.096, mean bias 0.02, limits of agreement [LoA] -0.14/0.19, r = 0.83, ICC = 0.92), and in the per-patient analysis (0.81 [0.60-0.86] vs. 0.76 [0.64-0.86], P = 0.768, mean bias 0.02, LoA -0.15/0.19, r = 0.90, ICC = 0.93). All included patients were classified into the same category (CT-FFR > 0.75 vs ≤0.75) with both CT systems. CONCLUSIONS: CT-FFR evaluation is feasible with PCD-CT and it shows a strong agreement with EID-CT-based evaluation when images are similarly reconstructed.
Assuntos
Angiografia por Tomografia Computadorizada , Reserva Fracionada de Fluxo Miocárdico , Humanos , Feminino , Angiografia por Tomografia Computadorizada/métodos , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos , Imagens de FantasmasRESUMO
BACKGROUND: The potential role of cardiac computed tomography (CT) has increasingly been demonstrated for the assessment of diffuse myocardial fibrosis through the quantification of extracellular volume (ECV). Photon-counting detector (PCD)-CT technology may deliver more accurate ECV quantification compared to energy-integrating detector CT. We evaluated the impact of reconstruction settings on the accuracy of ECV quantification using PCD-CT, with magnetic resonance imaging (MRI)-based ECV as reference. METHODS: In this post hoc analysis, 27 patients (aged 53.1 ± 17.2 years (mean ± standard deviation); 14 women) underwent same-day cardiac PCD-CT and MRI. Late iodine CT scans were reconstructed with different quantum iterative reconstruction levels (QIR 1-4), slice thicknesses (0.4-8 mm), and virtual monoenergetic imaging levels (VMI, 40-90 keV); ECV was quantified for each reconstruction setting. Repeated measures ANOVA and t-test for pairwise comparisons, Bland-Altman plots, and Lin's concordance correlation coefficient (CCC) were used. RESULTS: ECV values did not differ significantly among QIR levels (p = 1.000). A significant difference was observed throughout different slice thicknesses, with 0.4 mm yielding the highest agreement with MRI-based ECV (CCC = 0.944); 45-keV VMI reconstructions showed the lowest mean bias (0.6, 95% confidence interval 0.1-1.4) compared to MRI. Using the most optimal reconstruction settings (QIR4. slice thickness 0.4 mm, VMI 45 keV), a 63% reduction in mean bias and a 6% increase in concordance with MRI-based ECV were achieved compared to standard settings (QIR3, slice thickness 1.5 mm; VMI 65 keV). CONCLUSIONS: The selection of appropriate reconstruction parameters improved the agreement between PCD-CT and MRI-based ECV. RELEVANCE STATEMENT: Tailoring PCD-CT reconstruction parameters optimizes ECV quantification compared to MRI, potentially improving its clinical utility. KEY POINTS: ⢠CT is increasingly promising for myocardial tissue characterization, assessing focal and diffuse fibrosis via late iodine enhancement and ECV quantification, respectively. ⢠PCD-CT offers superior performance over conventional CT, potentially improving ECV quantification and its agreement with MRI-based ECV. ⢠Tailoring PCD-CT reconstruction parameters optimizes ECV quantification compared to MRI, potentially improving its clinical utility.
Assuntos
Imageamento por Ressonância Magnética , Miocárdio , Tomografia Computadorizada por Raios X , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Idoso , Fótons , Adulto , Processamento de Imagem Assistida por Computador/métodos , Coração/diagnóstico por imagemRESUMO
BACKGROUND: We compared ultra-high resolution (UHR), standard resolution (SR), and virtual non-calcium (VNCa) reconstruction for coronary artery stenosis evaluation using photon-counting computed tomography (PC-CT). METHODS: One vessel phantom (4-mm diameter) containing solid calcified lesions with 25% and 50% stenoses inside a thorax phantom with motion simulation underwent PC-CT using UHR (0.2-mm slice thickness) and SR (0.6-mm slice thickness) at heart rates of 60 beats per minute (bpm), 80 bpm, and 100 bpm. A paired t-test or Wilcoxon test with Bonferroni correction was used. RESULTS: For 50% stenosis, differences in percent mean diameter stenosis between UHR and SR at 60 bpm (51.0 vs 60.3), 80 bpm (51.7 vs 59.6), and 100 bpm (53.7 vs 59.0) (p ≤ 0.011), as well as between VNCa and SR at 60 bpm (50.6 vs 60.3), 80 bpm (51.5 vs 59.6), and 100 bpm (53.7 vs 59.0) were significant (p ≤ 0.011), while differences between UHR and VNCa at all heart rates (p ≥ 0.327) were not significant. For 25% stenosis, differences between UHR and SR at 60 bpm (28.0 vs 33.7), 80 bpm (28.4 vs 34.3), and VNCa vs SR at 60 bpm (29.1 vs 33.7) were significant (p ≤ 0.015), while differences for UHR vs SR at 100 bpm (29.9 vs 34.0), as well as for VNCa vs SR at 80 bpm (30.7 vs 34.3) and 100 bpm (33.1 vs 34.0) were not significant (p ≥ 0.028). CONCLUSION: Stenosis quantification accuracy with PC-CT improved using either UHR acquisition or VNCa reconstruction. RELEVANCE STATEMENT: PC-CT offers to scan with UHR mode and the reconstruction of VNCa images both of them could provide improved coronary stenosis quantification at increased heart rates, allowing a more accurate stenosis grading at low and high heart rates compared to SR. KEY POINTS: Evaluation of coronary stenosis with conventional CT is challenging at high heart rates. PC-CT allows for scanning with ECG-gated UHR and SR modes. UHR and VNCa images were compared in a dynamic phantom. UHR improves stenosis quantification up to 100 bpm. VNCa reconstruction improves stenosis evaluation up to 80 bpm.
Assuntos
Algoritmos , Estenose Coronária , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Fótons , Processamento de Imagem Assistida por Computador/métodosRESUMO
Purpose To investigate the impact of plaque size and density on virtual noncontrast (VNC)-based coronary artery calcium scoring (CACS) using photon-counting detector CT and to provide safety net reconstructions for improved detection of subtle plaques in patients whose VNC-based CACS would otherwise be erroneously zero when compared with true noncontrast (TNC)-based CACS. Materials and Methods In this prospective study, CACS was evaluated in a phantom containing calcifications with different diameters (5, 3, and 1 mm) and densities (800, 400, and 200 mg/cm3) and in participants who underwent TNC and contrast-enhanced cardiac photon-counting detector CT (July 2021-March 2022). VNC images were reconstructed at different virtual monoenergetic imaging (55-80 keV) and quantum iterative reconstruction (QIR) levels (QIR,1-4). TNC scans at 70 keV with QIR off served as the reference standard. In vitro CACS was analyzed using standard settings (3.0-mm sections, kernel Qr36, 130-HU threshold). Calcification detectability and CACS of small and low-density plaques were also evaluated using 1.0-mm sections, kernel Qr44, and 120- or 110-HU thresholds. Safety net reconstructions were defined based on background Agatston scores and evaluated in vivo in TNC plaques initially nondetectable using standard VNC reconstructions. Results The in vivo cohort included 63 participants (57.8 years ± 15.5 [SD]; 37 [59%] male, 26 [41%] female). Correlation and agreement between standard CACSVNC and CACSTNC were higher in large- and medium-sized and high- and medium-density than in low-density plaques (in vitro: intraclass correlation coefficient [ICC] ≥ 0.90; r > 0.9 vs ICC = 0.20-0.48; r = 0.5-0.6). Small plaques were not detectable using standard VNC reconstructions. Calcification detectability was highest using 1.0-mm sections, kernel Qr44, 120- and 110-HU thresholds, and QIR level of 2 or less VNC reconstructions. Compared with standard VNC, using safety net reconstructions (55 keV, QIR 2, 110-HU threshold) for in vivo subtle plaque detection led to higher detection (increased by 89% [50 of 56]) and improved correlation and agreement of CACSVNC with CACSTNC (in vivo: ICC = 0.51-0.61; r = 0.6). Conclusion Compared with TNC-based calcium scoring, VNC-based calcium scoring was limited for small and low-density plaques but improved using safety net reconstructions, which may be particularly useful in patients with low calcium scores who would otherwise be treated based on potentially false-negative results. Keywords: Coronary Artery Calcium CT, Photon-Counting Detector CT, Virtual Noncontrast, Plaque Size, Plaque Density Supplemental material is available for this article. © RSNA, 2024.
Assuntos
Doença da Artéria Coronariana , Imagens de Fantasmas , Placa Aterosclerótica , Humanos , Masculino , Feminino , Estudos Prospectivos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Idoso , Fótons , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/patologia , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Angiografia Coronária/métodos , Meios de ContrasteRESUMO
We aimed to correlate left atrial appendage (LAA) structure and function with the history of stroke/transient ischemic attack (TIA) in patients with atrial fibrillation (AF). We analyzed the data of 649 patients with AF who were scheduled for catheter ablation. Patients underwent cardiac computed tomography and transesophageal echocardiography before ablation. The LAA morphologies depicted by cardiac computed tomography were categorized into 4 groups: cauliflower, chicken wing, swan, and windsock shapes. The mean age was 61.3 ± 10.5 years, 33.9% were women. The prevalence of stroke/TIA was 7.1%. After adjustment for the main risk factors, the LAA flow velocity ≤35.3 cm/s (odds ratio [OR] 2.18, 95% confidence interval [CI] 1.09 to 4.61, p = 0.033) and the swan LAA shape (OR 2.69, 95% CI 0.96 to 6.86, p = 0.047) independently associated with a higher risk of stroke/TIA, whereas the windsock LAA morphology proved to be protective (OR 0.32, 95% CI 0.12 to 0.77, p = 0.017) compared with the cauliflower LAA shape. Comparing the differences between the LAA morphology groups, we measured a significantly smaller LAA orifice area (389.3 ± 137.7 mm2 in windsock vs 428.3 ± 158.9 ml in cauliflower, p = 0.021) and LAA volume (7.4 ± 3.0 mm2 in windsock vs 8.5 ± 4.8 mm2 in cauliflower, p = 0.012) in patients with windsock LAA morphology, whereas the LAA flow velocity did not differ significantly. Reduced LAA function and swan LAA morphology were independently associated with a higher prevalence of stroke/TIA, whereas the windsock LAA shape proved to be protective. Comparing the differences between the various LAA morphology types, significantly lower LAA volume and LAA orifice area were measured in the windsock LAA shape than in the cauliflower LAA shape.
Assuntos
Apêndice Atrial , Fibrilação Atrial , Ecocardiografia Transesofagiana , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Feminino , Masculino , Ataque Isquêmico Transitório/epidemiologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/epidemiologia , Pessoa de Meia-Idade , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Risco , Idoso , Ablação por Cateter , Tomografia Computadorizada por Raios X , Estudos RetrospectivosRESUMO
PURPOSE: To assess the impact of different quantum iterative reconstruction (QIR) levels on objective and subjective image quality of ultra-high resolution (UHR) coronary CT angiography (CCTA) images and to determine the effect of strength levels on stenosis quantification using photon-counting detector (PCD)-CT. METHOD: A dynamic vessel phantom containing two calcified lesions (25 % and 50 % stenosis) was scanned at heart rates of 60, 80 and 100 beats per minute with a PCD-CT system. In vivo CCTA examinations were performed in 102 patients. All scans were acquired in UHR mode (slice thickness0.2 mm) and reconstructed with four different QIR levels (1-4) using a sharp vascular kernel (Bv64). Image noise, signal-to-noise ratio (SNR), sharpness, and percent diameter stenosis (PDS) were quantified in the phantom, while noise, SNR, contrast-to-noise ratio (CNR), sharpness, and subjective quality metrics (noise, sharpness, overall image quality) were assessed in patient scans. RESULTS: Increasing QIR levels resulted in significantly lower objective image noise (in vitro and in vivo: both p < 0.001), higher SNR (both p < 0.001) and CNR (both p < 0.001). Sharpness and PDS values did not differ significantly among QIRs (all pairwise p > 0.008). Subjective noise of in vivo images significantly decreased with increasing QIR levels, resulting in significantly higher image quality scores at increasing QIR levels (all pairwise p < 0.001). Qualitative sharpness, on the other hand, did not differ across different levels of QIR (p = 0.15). CONCLUSIONS: The QIR algorithm may enhance the image quality of CCTA datasets without compromising image sharpness or accurate stenosis measurements, with the most prominent benefits at the highest strength level.
Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Imagens de Fantasmas , Fótons , Razão Sinal-Ruído , Humanos , Angiografia por Tomografia Computadorizada/métodos , Masculino , Feminino , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , AlgoritmosRESUMO
RATIONALE AND OBJECTIVES: Coronary CT angiography (CCTA) is mandatory before transcatheter aortic valve replacement (TAVR). Our objective was to evaluate the efficacy of artificial intelligence (AI)-powered software in automatically analyzing cardiac parameters from pre-procedural CCTA to predict major adverse cardiovascular events (MACE) in TAVR patients. MATERIALS AND METHODS: Patients undergoing pre-TAVR CCTA were retrospectively included. AI software automatically extracted 34 morphologic and volumetric cardiac parameters characterizing the ventricles, atria, myocardium, and epicardial adipose tissue. Clinical information and outcomes were recorded from institutional database. Cox regression analysis identified predictors of MACE, including non-fatal myocardial infarction, heart failure hospitalization, unstable angina, and cardiac death. Model performance was evaluated with Harrell's C-index, and nested models were compared using the likelihood ratio test. Manual analysis of 170 patients assessed agreement with automated measurements. RESULTS: Among the 648 enrolled patients (77 ± 9.3 years, 58.9% men), 116 (17.9%) experienced MACE within a median follow-up of 24 months (interquartile range 10-40). After adjusting for clinical parameters, only left ventricle long axis shortening (LV-LAS) was an independent predictor of MACE (hazard ratio [HR], 1.05 [95% confidence interval, 1.05-1.11]; p = 0.04), with significantly improved C-index (0.620 vs. 0.633; p < 0.001). When adjusted for the Society of Thoracic Surgeons Predicted Risk of Mortality score, LV-LAS was also predictive of MACE (HR, 1.08 [95%CI, 1.03-1.13]; p = 0.002), while improving model performance (C-index: 0.557 vs. 0.598; p < 0.001). All parameters showed good or excellent agreement with manual measurements. CONCLUSION: Automated AI-based comprehensive cardiac assessment enables pre-TAVR MACE prediction, with LV-LAS outperforming all other parameters.
RESUMO
BACKGROUND: A recent simulation study proposed that stenosis measurements on coronary computed tomography (CT) angiography are influenced by the improved spatial resolution of photon-counting detector (PCD)-CT. The aim of the current study was to evaluate the impact of ultrahigh-spatial-resolution (UHR) on coronary stenosis measurements and Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification rates in patients undergoing coronary CT angiography on both PCD-CT and energy-integrating detector (EID)-CT and to compare measurements against quantitative coronary angiography. METHODS: Patients with coronary calcification on EID-CT (collimation, 192×0.6 mm) were prospectively enrolled for a research coronary CT angiography with UHR PCD-CT (collimation, 120×0.2 mm) within 30 days (between April 1, 2023 and January 31, 2024). PCD-CT was acquired with the same or lower CT dose index and equivalent contrast media volume as EID-CT. Percentage diameter stenosis (PDS) for calcified, partially calcified, and noncalcified lesions were compared between scanners. Patient-level reclassification rates for CAD-RADS were evaluated. The accuracy of PDS measurements was validated against quantitative coronary angiography in patients who underwent invasive coronary angiography. RESULTS: In total, PDS of 278 plaques were quantified in 49 patients (calcified, 202; partially calcified, 51; noncalcified, 25). PCD-CT-based PDS values were lower than EID-CT measurements for calcified (45.1±20.7 versus 54.6±19.2%; P<0.001) and partially calcified plaques (44.3±19.6 versus 54.9±20.0%; P<0.001), without significant differences for noncalcified lesions (39.1±15.2 versus 39.0±16.0%; P=0.98). The reduction in stenosis degrees led to a 49.0% (24/49) reclassification rate to a lower CAD-RADS with PCD-CT. In a subset of 12 patients with 56 lesions, UHR-based PDS values showed higher agreement with quantitative coronary angiography (mean difference, 7.3%; limits of agreement, -10.7%/25.2%) than EID-CT measurements (mean difference, 17.4%; limits of agreement, -6.9%/41.7%). CONCLUSIONS: Compared with conventional EID-CT, UHR PCD-CT results in lower PDS values and more accurate stenosis measurements in coronary plaques with calcified components and leads to a substantial Coronary Artery Disease Reporting and Data System reclassification rate in 49.0% of patients.
Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Humanos , Estenose Coronária/diagnóstico por imagem , Masculino , Feminino , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Vasos Coronários/diagnóstico por imagem , Fótons , Índice de Gravidade de Doença , Calcificação Vascular/diagnóstico por imagemRESUMO
PURPOSE: To evaluate the feasibility of CT angiography-derived fractional flow reserve (CT-FFR) calculations on ultrahigh-resolution (UHR) photon-counting detector (PCD)-CT series and to intra-individually compare the results with energy-integrating (EID)-CT measurements. METHOD: Prospective patients with calcified plaques detected on EID-CT between April 1st, 2023 and January 31st, 2024 were recruited for a UHR CCTA on PCD-CT within 30 days. PCD-CT was performed using the same or a lower CT dose index and an equivalent volume of contrast media. An on-site machine learning algorithm was used to obtain CT-FFR values on a per-vessel and per-patient basis. For all analyses, CT-FFR values ≤ 0.80 were deemed to be hemodynamically significant. RESULTS: A total of 34 patients (age: 67.3 ± 6.6 years, 7 women [20.6 %]) were included. Excellent inter-scanner agreement was noted for CT-FFR values in the per-vessel (ICC: 0.93 [0.90-0.95]) and per-patient (ICC: 0.94 [0.88-0.97]) analysis. PCD-CT-derived CT-FFR values proved to be higher compared to EID-CT values on both vessel (0.58 ± 0.23 vs. 0.55 ± 0.23, p < 0.001) and patient levels (0.73 ± 0.23 vs. 0.70 ± 0.22, p < 0.001). Two patients (5.9 %) with hemodynamically significant lesions on EID-CT were reclassified as non-significant on PCD-CT. All remaining participants were classified into the same category with both scanner systems. CONCLUSIONS: While UHR CT-FFR values demonstrate excellent agreement with EID-CT measurements, PCD-CT produces higher CT-FFR values that could contribute to a reclassification of hemodynamic significance.
RESUMO
Dual-energy computed tomography (DECT) acquires images using two energy spectra and offers a variation of reconstruction techniques for improved cardiac imaging. Virtual monoenergetic images decrease artifacts improving coronary plaque and stent visualization. Further, contrast attenuation is increased allowing significant reduction of contrast dose. Virtual non-contrast reconstructions enable coronary artery calcium scoring from contrast-enhanced scans. DECT provides advanced plaque imaging with detailed analysis of plaque components, indicating plaque stability. Extracellular volume assessment using DECT offers noninvasive detection of myocardial fibrosis. This review aims to outline the current cardiac applications of DECT, summarize recent literature, and discuss their findings.
Assuntos
Coração , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodosRESUMO
ABSTRACT: Noninvasive cardiac imaging has rapidly evolved during the last decade owing to improvements in computed tomography (CT)-based technologies, among which we highlight the recent introduction of the first clinical photon-counting detector CT (PCD-CT) system. Multiple advantages of PCD-CT have been demonstrated, including increased spatial resolution, decreased electronic noise, and reduced radiation exposure, which may further improve diagnostics and may potentially impact existing management pathways. The benefits that can be obtained from the initial experiences with PCD-CT are promising. The implementation of this technology in cardiovascular imaging allows for the quantification of coronary calcium, myocardial extracellular volume, myocardial radiomics features, epicardial and pericoronary adipose tissue, and the qualitative assessment of coronary plaques and stents. This review aims to discuss these major applications of PCD-CT with a focus on cardiac and myocardial characterization.
Assuntos
Coração , Tomografia Computadorizada por Raios X , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Miocárdio , FótonsRESUMO
Arterial plaque rupture and thrombosis is the primary cause of major cardiovascular and neurovascular events. The identification of atherosclerosis, especially high-risk plaques, is therefore crucial to identify high-risk patients and to implement preventive therapies. Computed tomography angiography has the ability to visualize and characterize vascular plaques. The standard methods for plaque evaluation rely on the assessment of plaque burden, stenosis severity, the presence of positive remodeling, napkin ring sign, and spotty calcification, as well as Hounsfield Unit (HU)-based thresholding for plaque quantification; the latter with multiple shortcomings. Semiautomated threshold-based segmentation techniques with predefined HU ranges identify and quantify limited plaque characteristics, such as low attenuation, non-calcified, and calcified plaque components. Contrary to HU-based thresholds, histologically validated plaque characterization, and quantification, an emerging Artificial intelligence-based approach has the ability to differentiate specific tissue types based on a biological correlate, such as lipid-rich necrotic core and intraplaque hemorrhage that determine plaque vulnerability. In this article, we review the relevance of plaque characterization and quantification and discuss the benefits and limitations of the currently available plaque assessment and classification techniques.
Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Inteligência Artificial , Angiografia Coronária/métodos , Placa Aterosclerótica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários , Valor Preditivo dos TestesRESUMO
PURPOSE: To intra-individually compare the objective and subjective image quality of coronary computed tomography angiography (CCTA) between photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). METHOD: Consecutive patients undergoing clinically indicated CCTA on an EID-CT system were prospectively enrolled for a research CCTA performed on a PCD-CT system within 30 days. Polychromatic images were reconstructed for both EID- and PCD-CT, while virtual monoenergetic images (VMI) were generated at 40, 45, 50, 55, 60 and 70 keV for PCD-CT. Two blinded readers calculated contrast-to-noise ratio (CNR) for each major coronary artery and rated image noise, vessel attenuation, vessel sharpness, and overall quality on a 1-5 Likert scale. Patients were then stratified by body mass index (BMI) [high (>30 kg/m2) vs low (<30 kg/m2)] for subgroup analysis. RESULTS: A total of 20 patients (67.5 ± 9.0 years, 75% male) were included in the study. Compared with EID-CT, coronary artery CNR values from PCD-CT monoenergetic and polychromatic reconstructions were all significantly higher than CNR values from EID-CT, with incrementally greater differences in obese subjects (all p < 0.008). Subjective image noise and sharpness were also significantly higher for all VMI reconstructions compared to EID-CT (all p < 0.008). All subjective scores were significantly higher for 55, 60, and 70 keV PCD-CT than EID-CT values (all p < 0.05). CONCLUSIONS: The improved objective and subjective image quality of PCD-CT compared to EID-CT may provide better visualization of the coronary arteries for a wide array of patients, especially those with a high BMI.
Assuntos
Vasos Coronários , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Coração , Fótons , Imagens de FantasmasRESUMO
This study assessed the impact of cardiac motion and in-vessel attenuation on coronary artery calcium (CAC) scoring using virtual non-iodine (VNI) against virtual non-contrast (VNC) reconstructions on photon-counting detector CT. Two artificial vessels containing calcifications and different in-vessel attenuations (500, 800HU) were scanned without (static) and with cardiac motion (60, 80, 100 beats per minute [bpm]). Images were post-processed using a VNC and VNI algorithm at 70 keV and quantum iterative reconstruction (QIR) strength 2. Calcium mass, Agatston scores, cardiac motion susceptibility (CMS)-indices were compared to physical mass, static scores as well as between reconstructions, heart rates and in-vessel attenuations. VNI scores decreased with rising heart rate (p < 0.01) and showed less underestimation than VNC scores (p < 0.001). Only VNI scores were similar to the physical mass at static measurements, and to static scores at 60 bpm. Agatston scores using VNI were similar to static scores at 60 and 80 bpm. Standard deviation of CMS-indices was lower for VNI-based than for VNC-based CAC scoring. VNI scores were higher at 500 than 800HU (p < 0.001) and higher than VNC scores (p < 0.001) with VNI scores at 500 HU showing the lowest deviation from the physical reference. VNI-based CAC quantification is influenced by cardiac motion and in-vessel attenuation, but least when measuring Agatston scores, where it outperforms VNC-based CAC scoring.
RESUMO
BACKGROUND: Photon-counting detector computed tomography (PCD-CT) may influence imaging characteristics for various clinical conditions due to higher signal and contrast-to-noise ratio in virtual monoenergetic images (VMI). Radiomics analysis relies on quantification of image characteristics. We evaluated the impact of different VMI reconstructions on radiomic features in in vitro and in vivo PCD-CT datasets. METHODS: An organic phantom consisting of twelve samples (four oranges, four onions, and four apples) was scanned five times. Twenty-three patients who had undergone coronary computed tomography angiography on a first generation PCD-CT system with the same image acquisitions were analyzed. VMIs were reconstructed at 6 keV levels (40, 55, 70, 90, 120, and 190 keV). The phantoms and the patients' left ventricular myocardium (LVM) were segmented for all reconstructions. Ninety-three original radiomic features were extracted. Repeatability and reproducibility were evaluated through intraclass correlations coefficient (ICC) and post hoc paired samples ANOVA t test. RESULTS: There was excellent repeatability for radiomic features in phantom scans (all ICC = 1.00). Among all VMIs, 36/93 radiomic features (38.7%) in apples, 28/93 (30.1%) in oranges, and 33/93 (35.5%) in onions were not significantly different. For LVM, the percentage of stable features was high between VMIs ≥ 90 keV (90 versus 120 keV, 77.4%; 90 versus 190 keV, 83.9%; 120 versus 190 keV, 89.3%), while comparison to lower VMI levels led to fewer reproducible features (40 versus 55 keV, 8.6%). CONCLUSIONS: VMI levels influence the stability of radiomic features in an organic phantom and patients' LVM; stability decreases considerably below 90 keV. RELEVANCE STATEMENT: Spectral reconstructions significantly influence radiomic features in vitro and in vivo, necessitating standardization and careful attention to these reconstruction parameters before clinical implementation. KEY POINTS: ⢠Radiomic features have an excellent repeatability within the same PCD-CT acquisition and reconstruction. ⢠Differences in VMI lead to decreased reproducibility for radiomic features. ⢠VMI ≥ 90 keV increased the reproducibility of the radiomic features.