Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Neurol Neurosurg Psychiatry ; 95(6): 515-527, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38124162

RESUMO

BACKGROUND: Although CT perfusion (CTP) is often incorporated in acute stroke workflows, it remains largely unclear what the associated costs and health implications are in the long run of CTP-based patient selection for endovascular treatment (EVT) in patients presenting within 6 hours after symptom onset with a large vessel occlusion. METHODS: Patients with a large vessel occlusion were included from a Dutch nationwide cohort (n=703) if CTP imaging was performed before EVT within 6 hours after stroke onset. Simulated cost and health effects during 5 and 10 years follow-up were compared between CTP based patient selection for EVT and providing EVT to all patients. Outcome measures were the net monetary benefit at a willingness-to-pay of €80 000 per quality-adjusted life year, incremental cost-effectiveness ratio), difference in costs from a healthcare payer perspective (ΔCosts) and quality-adjusted life years (ΔQALY) per 1000 patients for 1000 model iterations as outcomes. RESULTS: Compared with treating all patients, CTP-based selection for EVT at the optimised ischaemic core volume (ICV≥110 mL) or core-penumbra mismatch ratio (MMR≤1.4) thresholds resulted in losses of health (median ΔQALYs for ICV≥110 mL: -3.3 (IQR: -5.9 to -1.1), for MMR≤1.4: 0.0 (IQR: -1.3 to 0.0)) with median ΔCosts for ICV≥110 mL of -€348 966 (IQR: -€712 406 to -€51 158) and for MMR≤1.4 of €266 513 (IQR: €229 403 to €380 110)) per 1000 patients. Sensitivity analyses did not yield any scenarios for CTP-based selection of patients for EVT that were cost-effective for improving health, including patients aged ≥80 years CONCLUSION: In EVT-eligible patients presenting within 6 hours after symptom onset, excluding patients based on CTP parameters was not cost-effective and could potentially harm patients.


Assuntos
Análise Custo-Benefício , Procedimentos Endovasculares , Anos de Vida Ajustados por Qualidade de Vida , Acidente Vascular Cerebral , Trombectomia , Humanos , Masculino , Trombectomia/economia , Trombectomia/métodos , Procedimentos Endovasculares/economia , Procedimentos Endovasculares/métodos , Feminino , Idoso , Acidente Vascular Cerebral/economia , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Tomografia Computadorizada por Raios X/economia , Pessoa de Meia-Idade , Seleção de Pacientes , Países Baixos , Imagem de Perfusão , Idoso de 80 Anos ou mais , Modelos Econômicos , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/cirurgia , AVC Isquêmico/economia
2.
Eur Radiol ; 34(2): 797-807, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37572189

RESUMO

OBJECTIVES: We aimed to evaluate the real-world variation in CT perfusion (CTP) imaging protocols among stroke centers and to explore the potential for standardizing vendor software to harmonize CTP images. METHODS: Stroke centers participating in a nationwide multicenter healthcare evaluation were requested to share their CTP scan and processing protocol. The impact of these protocols on CTP imaging was assessed by analyzing data from an anthropomorphic phantom with center-specific vendor software with default settings from one of three vendors (A-C): IntelliSpace Portal, syngoVIA, and Vitrea. Additionally, standardized infarct maps were obtained using a logistic model. RESULTS: Eighteen scan protocols were studied, all varying in acquisition settings. Of these protocols, seven, eight, and three were analyzed with center-specific vendor software A, B, and C respectively. The perfusion maps were visually dissimilar between the vendor software but were relatively unaffected by the acquisition settings. The median error [interquartile range] of the infarct core volumes (mL) estimated by the vendor software was - 2.5 [6.5] (A)/ - 18.2 [1.2] (B)/ - 8.0 [1.4] (C) when compared to the ground truth of the phantom (where a positive error indicates overestimation). Taken together, the median error [interquartile range] of the infarct core volumes (mL) was - 8.2 [14.6] before standardization and - 3.1 [2.5] after standardization. CONCLUSIONS: CTP imaging protocols varied substantially across different stroke centers, with the perfusion software being the primary source of differences in CTP images. Standardizing the estimation of ischemic regions harmonized these CTP images to a degree. CLINICAL RELEVANCE STATEMENT: The center that a stroke patient is admitted to can influence the patient's diagnosis extensively. Standardizing vendor software for CT perfusion imaging can improve the consistency and accuracy of results, enabling a more reliable diagnosis and treatment decision. KEY POINTS: • CT perfusion imaging is widely used for stroke evaluation, but variation in the acquisition and processing protocols between centers could cause varying patient diagnoses. • Variation in CT perfusion imaging mainly arises from differences in vendor software rather than acquisition settings, but these differences can be reconciled by standardizing the estimation of ischemic regions. • Standardizing the estimation of ischemic regions can improve CT perfusion imaging for stroke evaluation by facilitating reliable evaluations independent of the admission center.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Isquemia Encefálica/terapia , Acidente Vascular Cerebral/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Imagem de Perfusão/métodos , Infarto , Perfusão
3.
Eur Radiol ; 34(4): 2152-2167, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37728778

RESUMO

OBJECTIVES: CT perfusion (CTP) has been suggested to increase the rate of large vessel occlusion (LVO) detection in patients suspected of acute ischemic stroke (AIS) if used in addition to a standard diagnostic imaging regime of CT angiography (CTA) and non-contrast CT (NCCT). The aim of this study was to estimate the costs and health effects of additional CTP for endovascular treatment (EVT)-eligible occlusion detection using model-based analyses. METHODS: In this Dutch, nationwide retrospective cohort study with model-based health economic evaluation, data from 701 EVT-treated patients with available CTP results were included (January 2018-March 2022; trialregister.nl:NL7974). We compared a cohort undergoing NCCT, CTA, and CTP (NCCT + CTA + CTP) with a generated counterfactual where NCCT and CTA (NCCT + CTA) was used for LVO detection. The NCCT + CTA strategy was simulated using diagnostic accuracy values and EVT effects from the literature. A Markov model was used to simulate 10-year follow-up. We adopted a healthcare payer perspective for costs in euros and health gains in quality-adjusted life years (QALYs). The primary outcome was the net monetary benefit (NMB) at a willingness to pay of €80,000; secondary outcomes were the difference between LVO detection strategies in QALYs (ΔQALY) and costs (ΔCosts) per LVO patient. RESULTS: We included 701 patients (median age: 72, IQR: [62-81]) years). Per LVO patient, CTP-based occlusion detection resulted in cost savings (ΔCosts median: € - 2671, IQR: [€ - 4721; € - 731]), a health gain (ΔQALY median: 0.073, IQR: [0.044; 0.104]), and a positive NMB (median: €8436, IQR: [5565; 11,876]) per LVO patient. CONCLUSION: CTP-based screening of suspected stroke patients for an endovascular treatment eligible large vessel occlusion was cost-effective. CLINICAL RELEVANCE STATEMENT: Although CTP-based patient selection for endovascular treatment has been recently suggested to result in worse patient outcomes after ischemic stroke, an alternative CTP-based screening for endovascular treatable occlusions is cost-effective. KEY POINTS: • Using CT perfusion to detect an endovascular treatment-eligible occlusions resulted in a health gain and cost savings during 10 years of follow-up. • Depending on the screening costs related to the number of patients needed to image with CT perfusion, cost savings could be considerable (median: € - 3857, IQR: [€ - 5907; € - 1916] per patient). • As the gain in quality adjusted life years was most affected by the sensitivity of CT perfusion-based occlusion detection, additional studies for the diagnostic accuracy of CT perfusion for occlusion detection are required.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Idoso , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/terapia , Análise Custo-Benefício , Estudos Retrospectivos , Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada por Raios X/métodos , Perfusão , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Isquemia Encefálica/terapia , Isquemia Encefálica/tratamento farmacológico , Trombectomia
4.
Stroke ; 54(3): 821-830, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36779342

RESUMO

BACKGROUND: Identifying cardioembolic sources in patients with acute ischemic stroke is important for the choice of secondary prevention strategies. We prospectively investigated the yield of admission (spectral) nongated cardiac computed tomography angiography (CTA) to detect cardioembolic sources in stroke. METHODS: Participants of the ENCLOSE study (Improved Prediction of Recurrent Stroke and Detection of Small Volume Stroke) with transient ischemic attack or acute ischemic stroke with assessable nongated head-to-heart CTA at the University Medical Center Utrecht were included between June 2017 and March 2022. The presence of cardiac thrombus on cardiac CTA was based on a Likert scale and dichotomized into certainly or probably absent versus possibly, probably, or certainly present. The diagnostic certainty of cardiac thrombus was evaluated again on spectral computed tomography reconstructions. The likelihood of a cardioembolic source was determined post hoc by an expert panel in patients with cardiac thrombus on CTA. Parametric and nonparametric tests were used to compare the outcome groups. RESULTS: Forty four (12%) of 370 included patients had a cardiac thrombus on admission CTA: 35 (9%) in the left atrial appendage and 14 (4%) in the left ventricle. Patients with cardiac thrombus had more severe strokes (median National Institutes of Health Stroke Scale score, 10 versus 4; P=0.006), had higher clot burden (median clot burden score, 9 versus 10; P=0.004), and underwent endovascular treatment more often (43% versus 20%; P<0.001) than patients without cardiac thrombus. Left atrial appendage thrombus was present in 28% and 6% of the patients with and without atrial fibrillation, respectively (P<0.001). The diagnostic certainty for left atrial appendage thrombus was higher for spectral iodine maps compared with the conventional CTA (P<0.001). The presence of cardiac thrombus on CTA increased the likelihood of a cardioembolic source according to the expert panel (P<0.001). CONCLUSIONS: Extending the stroke CTA to cover the heart increases the chance of detecting cardiac thrombi and helps to identify cardioembolic sources in the acute stage of ischemic stroke with more certainty. Spectral iodine maps provide additional value for detecting left atrial appendage thrombus. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04019483.


Assuntos
Cardiopatias , AVC Isquêmico , Acidente Vascular Cerebral , Trombose , Humanos , Angiografia por Tomografia Computadorizada , Cardiopatias/complicações , AVC Isquêmico/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/complicações , Trombose/complicações , Tomografia Computadorizada por Raios X/métodos , Estados Unidos
5.
Eur Radiol ; 32(1): 517-523, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34132877

RESUMO

PURPOSE: This study evaluates the performance of a mobile and compact hybrid C-arm scanner (referred to as IXSI) that is capable of simultaneous acquisition of 2D fluoroscopic and nuclear projections and 3D image reconstruction in the intervention room. RESULTS: The impact of slightly misaligning the IXSI modalities (in an off-focus geometry) was investigated for the reduction of the fluoroscopic and nuclear interference. The 2D and 3D nuclear image quality of IXSI was compared with a clinical SPECT/CT scanner by determining the spatial resolution and sensitivity of point sources and by performing a quantitative analysis of the reconstructed NEMA image quality phantom. The 2D and 3D fluoroscopic image of IXSI was compared with a clinical CBCT scanner by visualizing the Fluorad A+D image quality phantom and by visualizing a reconstructed liver nodule phantom. Finally, the feasibility of dynamic simultaneous nuclear and fluoroscopic imaging was demonstrated by injecting an anthropomorphic phantom with a mixture of iodinated contrast and 99mTc. CONCLUSION: Due to the divergent innovative hybrid design of IXSI, concessions were made to the nuclear and fluoroscopic image qualities. Nevertheless, IXSI realizes unique image guidance that may be beneficial for several types of procedures. KEY POINTS: • IXSI can perform time-resolved planar (2D) simultaneous fluoroscopic and nuclear imaging. • IXSI can perform SPECT/CBCT imaging (3D) inside the intervention room.


Assuntos
Imageamento Tridimensional , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada de Feixe Cônico , Fluoroscopia , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
6.
Eur Radiol ; 32(9): 6367-6375, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35357536

RESUMO

OBJECTIVES: To compare single parameter thresholding with multivariable probabilistic classification of ischemic stroke regions in the analysis of computed tomography perfusion (CTP) parameter maps. METHODS: Patients were included from two multicenter trials and were divided into two groups based on their modified arterial occlusive lesion grade. CTP parameter maps were generated with three methods-a commercial method (ISP), block-circulant singular value decomposition (bSVD), and non-linear regression (NLR). Follow-up non-contrast CT defined the follow-up infarct region. Conventional thresholds for individual parameter maps were established with a receiver operating characteristic curve analysis. Probabilistic classification was carried out with a logistic regression model combining the available CTP parameters into a single probability. RESULTS: A total of 225 CTP data sets were included, divided into a group of 166 patients with successful recanalization and 59 with persistent occlusion. The precision and recall of the CTP parameters were lower individually than when combined into a probability. The median difference [interquartile range] in mL between the estimated and follow-up infarct volume was 29/23/23 [52/50/52] (ISP/bSVD/NLR) for conventional thresholding and was 4/6/11 [31/25/30] (ISP/bSVD/NLR) for the probabilistic classification. CONCLUSIONS: Multivariable probability maps outperform thresholded CTP parameter maps in estimating the infarct lesion as observed on follow-up non-contrast CT. A multivariable probabilistic approach may harmonize the classification of ischemic stroke regions. KEY POINTS: • Combining CTP parameters with a logistic regression model increases the precision and recall in estimating ischemic stroke regions. • Volumes following from a probabilistic analysis predict follow-up infarct volumes better than volumes following from a threshold-based analysis. • A multivariable probabilistic approach may harmonize the classification of ischemic stroke regions.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Isquemia Encefálica/diagnóstico por imagem , Circulação Cerebrovascular , Infarto , Perfusão , Imagem de Perfusão/métodos , Probabilidade , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/patologia , Tomografia Computadorizada por Raios X/métodos
7.
Eur Radiol ; 31(11): 8317-8325, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34050385

RESUMO

OBJECTIVES: To report the variation in computed tomography perfusion (CTP) arterial input function (AIF) in a multicenter stroke study and to assess the impact this has on CTP results. METHODS: CTP datasets from 14 different centers were included from the DUtch acute STroke (DUST) study. The AIF was taken as a direct measure to characterize contrast bolus injection. Statistical analysis was applied to evaluate differences in amplitude, area under the curve (AUC), bolus arrival time (BAT), and time to peak (TTP). To assess the clinical relevance of differences in AIF, CTP acquisitions were simulated with a realistic anthropomorphic digital phantom. Perfusion parameters were extracted by CTP analysis using commercial software (IntelliSpace Portal (ISP), version 10.1) as well as an in-house method based on block-circulant singular value decomposition (bSVD). RESULTS: A total of 1422 CTP datasets were included, ranging from 6 to 322 included patients per center. The measured values of the parameters used to characterize the AIF differed significantly with approximate interquartile ranges of 200-750 HU for the amplitude, 2500-10,000 HU·s for the AUC, 0-17 s for the BAT, and 10-26 s for the TTP. Mean infarct volumes of the phantom were significantly different between centers for both methods of perfusion analysis. CONCLUSIONS: Although guidelines for the acquisition protocol are often provided for centers participating in a multicenter study, contrast medium injection protocols still vary. The resulting volumetric differences in infarct core and penumbra may impact clinical decision making in stroke diagnosis. KEY POINTS: • The contrast medium injection protocol may be different between stroke centers participating in a harmonized multicenter study. • The contrast medium injection protocol influences the results of X-ray computed tomography perfusion imaging. • The contrast medium injection protocol can impact stroke diagnosis and patient selection for treatment.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Perfusão , Imagem de Perfusão , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
8.
Neuroradiology ; 63(1): 41-49, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32728777

RESUMO

PURPOSE: Early infarcts are hard to diagnose on non-contrast head CT. Dual-energy CT (DECT) may potentially increase infarct differentiation. The optimal DECT settings for differentiation were identified and evaluated. METHODS: One hundred and twenty-five consecutive patients who presented with suspected acute ischemic stroke (AIS) and underwent non-contrast DECT and subsequent DWI were retrospectively identified. The DWI was used as reference standard. First, virtual monochromatic images (VMI) of 25 patients were reconstructed from 40 to 140 keV and scored by two readers for acute infarct. Sensitivity, specificity, positive, and negative predictive values for infarct detection were compared and a subset of VMI energies were selected. Next, for a separate larger cohort of 100 suspected AIS patients, conventional non-contrast CT (NCT) and selected VMI were scored by two readers for the presence and location of infarct. The same statistics for infarct detection were calculated. Infarct location match was compared per vascular territory. Subgroup analyses were dichotomized by time from last-seen-well to CT imaging. RESULTS: A total of 80-90 keV VMI were marginally more sensitive (36.3-37.3%) than NCT (32.4%; p > 0.680), with marginally higher specificity (92.2-94.4 vs 91.1%; p > 0.509) for infarct detection. Location match was superior for VMI compared with NCT (28.7-27.4 vs 19.5%; p < 0.010). Within 4.5 h from last-seen-well, 80 keV VMI more accurately detected infarct (58.0 vs 54.0%) and localized infarcts (27.1 vs 11.9%; p = 0.004) than NCT, whereas after 4.5 h, 90 keV VMI was more accurate (69.3 vs 66.3%). CONCLUSION: Non-contrast 80-90 keV VMI best differentiates normal from infarcted brain parenchyma.


Assuntos
Isquemia Encefálica , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Acidente Vascular Cerebral , Infarto Cerebral/diagnóstico por imagem , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
9.
Neuroradiology ; 63(4): 483-490, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32857214

RESUMO

PURPOSE: The aim of this study was to evaluate whether the addition of brain CT imaging data to a model incorporating clinical risk factors improves prediction of ischemic stroke recurrence over 5 years of follow-up. METHODS: A total of 638 patients with ischemic stroke from three centers were selected from the Dutch acute stroke study (DUST). CT-derived candidate predictors included findings on non-contrast CT, CT perfusion, and CT angiography. Five-year follow-up data were extracted from medical records. We developed a multivariable Cox regression model containing clinical predictors and an extended model including CT-derived predictors by applying backward elimination. We calculated net reclassification improvement and integrated discrimination improvement indices. Discrimination was evaluated with the optimism-corrected c-statistic and calibration with a calibration plot. RESULTS: During 5 years of follow-up, 56 patients (9%) had a recurrence. The c-statistic of the clinical model, which contained male sex, history of hyperlipidemia, and history of stroke or transient ischemic attack, was 0.61. Compared with the clinical model, the extended model, which contained previous cerebral infarcts on non-contrast CT and Alberta Stroke Program Early CT score greater than 7 on mean transit time maps derived from CT perfusion, had higher discriminative performance (c-statistic 0.65, P = 0.01). Inclusion of these CT variables led to a significant improvement in reclassification measures, by using the net reclassification improvement and integrated discrimination improvement indices. CONCLUSION: Data from CT imaging significantly improved the discriminatory performance and reclassification in predicting ischemic stroke recurrence beyond a model incorporating clinical risk factors only.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Isquemia Encefálica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Perfusão , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
10.
J Comput Assist Tomogr ; 45(1): 103-109, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32176156

RESUMO

OBJECTIVE: We compared 40- to 70-keV virtual monoenergetic to conventional computed tomography (CT) perfusion reconstructions with respect to quality of perfusion maps. METHODS: Conventional CT perfusion (CTP) images were acquired at 80 kVp in 25 patients, and 40- to 70-keV images were acquired with a dual-layer CT at 120 kVp in 25 patients. First, time-attenuation-curve contrast-to-noise ratio was assessed. Second, the perfusion maps of both groups were qualitatively analyzed by observers. Last, the monoenergetic reconstruction with the highest quality was compared with the clinical standard 80-kVp CTP acquisitions. RESULTS: Contrast-to-noise ratio was significantly better for 40 to 60 keV as compared with 70 keV and conventional images (P < 0.001). Visually, the difference between the blood volume maps among reconstructions was minimal. The 50-keV perfusion maps had the highest quality compared with the other monoenergetic and conventional maps (P < 0.002). CONCLUSIONS: The quality of 50-keV CTP images is superior to the quality of conventional 80- and 120-kVp images.


Assuntos
Encéfalo/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
11.
Lancet Oncol ; 21(4): 561-570, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32112737

RESUMO

BACKGROUND: In patients with metastatic neuroendocrine neoplasms, the liver is the most commonly affected organ and a crucial factor for prognosis and survival. Peptide receptor radionuclide therapy can prolong progression-free survival in these patients. Additional treatment of liver disease might further improve outcomes. We aimed to investigate the safety and efficacy of additional holmium-166 (166Ho) radioembolisation after peptide receptor radionuclide therapy in patients with metastatic liver neuroendocrine neoplasms. METHODS: The Holmium Embolization Particles for Arterial Radiotherapy Plus 177Lu-Dotatate in Salvage Neuroendocrine Tumour Patients (HEPAR PLuS) study was a single-centre, phase 2 study done at the University Medical Center Utrecht (Utrecht, Netherlands). Patients, aged at least 18 years, with histologically proven grade 1 or 2 neuroendocrine neoplasms of all origins, an Eastern Cooperative Oncology Group performance status of 0-2, and three or more measurable liver metastases according to Response Evaluation Criteria In Solid Tumors (RECIST) version 1.1 criteria received 166Ho-radioembolisation within 20 weeks after four cycles of peptide receptor radionuclide therapy (lutetium-177-dotatate [177Lu-dotatate]). The primary endpoint was objective liver tumour response in the treated liver volume, defined as complete response (disappearance of all lesions) or partial response (≥30% decrease in the sum of the longest diameters of the target lesions, compared with baseline measurements), according to RECIST 1.1, analysed per protocol at 3 months. Safety was assessed in all patients who received treatment. This study is registered with ClinicalTrials.gov, NCT02067988. Recruitment is completed and long-term follow-up is ongoing. FINDINGS: From Oct 15, 2014, to Sept 12, 2018, 34 patients were assessed for eligibility. 31 patients received treatment and 30 (97%) patients were available for primary endpoint assessment and completed 6 months of follow-up. Three (9%) patients were excluded at screening and one (3%) patient was treated and died before the primary endpoint and was replaced. According to the per-protocol analysis 13 (43%; 95% CI 26-63) of 30 patients achieved an objective response in the treated volume. The most frequently reported Common Terminology Criteria for Adverse Events (CTCAE) grade 3-4 clinical and laboratory toxicities within 6 months included abdominal pain (three [10%] of 31 patients), increased γ-glutamyl transpeptidase (16 [54%]), and lymphocytopenia (seven [23%]). One (3%) fatal treatment-related serious adverse event occurred (radioembolisation-induced liver disease). Two (6%) patients had serious adverse events deemed to be unrelated to treatment (gastric ulcer and perforated cholecystitis). INTERPRETATION: 166Ho-radioembolisation, as an adjunct to peptide receptor radionuclide therapy in patients with neuroendocrine neoplasm liver metastases, is safe and efficacious. Radioembolisation can be considered in patients with bulky liver disease, including after peptide receptor radionuclide therapy. A future randomised, controlled study should investigate the added benefit of this treatment on progression-free survival. FUNDING: None.


Assuntos
Embolização Terapêutica/métodos , Hólmio/uso terapêutico , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Tumores Neuroendócrinos/patologia , Octreotida/análogos & derivados , Compostos Organometálicos/uso terapêutico , Radioisótopos/uso terapêutico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Octreotida/uso terapêutico , Estudos Prospectivos , Resultado do Tratamento
12.
Eur J Nucl Med Mol Imaging ; 47(4): 798-806, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31399801

RESUMO

PURPOSE: As an alternative to technetium-99m-macroaggregated albumin (99mTc-MAA), a scout dose of holmium-166 (166Ho) microspheres can be used prior to 166Ho-radioembolization. The use of identical particles for pre-treatment and treatment procedures may improve the predictive value of pre-treatment analysis of distribution. The aim of this study was to analyze the agreement between 166Ho-scout and 166Ho-therapeutic dose in comparison with the agreement between 99mTc-MAA and 166Ho-therapeutic dose. METHODS: Two separate scout dose procedures were performed (99mTc-MAA and 166Ho-scout) before treatment in 53 patients. First, qualitative assessment was performed by two blinded nuclear medicine physicians who visually rated the agreement between the 99mTc-MAA, 166Ho-scout, and 166Ho-therapeutic dose SPECT-scans (i.e., all performed in the same patient) on a 5-point scale. Second, agreement was measured quantitatively by delineating lesions and normal liver on FDG-PET/CT. These volumes of interest (VOIs) were co-registered to the SPECT/CT images. The predicted absorbed doses (based on 99mTc-MAA and 166Ho-scout) were compared with the actual absorbed dose on post-treatment SPECT. RESULTS: A total of 23 procedures (71 lesions, 22 patients) were included for analysis. In the qualitative analysis, 166Ho-scout was superior with a median score of 4 vs. 2.5 for 99mTc-MAA (p < 0.001). The quantitative analysis showed significantly narrower 95%-limits of agreement for 166Ho-scout in comparison with 99mTc-MAA when evaluating lesion absorbed dose (- 90.3 and 105.3 Gy vs. - 164.1 and 197.0 Gy, respectively). Evaluation of normal liver absorbed dose did not show difference in agreement between both scout doses and 166Ho-therapeutic dose (- 2.9 and 5.5 Gy vs - 3.6 and 4.1 Gy for 99mTc-MAA and 166Ho-scout, respectively). CONCLUSIONS: In this study, 166Ho-scout was shown to have a superior predictive value for intrahepatic distribution in comparison with 99mTc-MAA.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Albuminas , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Microesferas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Radioisótopos de Ítrio
13.
J Comput Assist Tomogr ; 44(1): 75-77, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31804241

RESUMO

Computed tomography perfusion (CTP) is increasingly used to determine treatment eligibility for acute ischemic stroke patients. Automated postprocessing of raw CTP data is routinely used, but it can fail. In reviewing 176 consecutive acute ischemic stroke patients, failures occurred in 20 patients (11%) during automated postprocessing by the RAPID software. Failures were caused by motion (n = 11, 73%), streak artifacts (n = 2, 13%), and poor contrast bolus arrival (n = 2, 13%). Stroke physicians should review CTP results with care before they are being integrated in their decision-making process.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Processamento Eletrônico de Dados/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/métodos , Fatores de Risco , Sensibilidade e Especificidade , Software , Tomografia Computadorizada por Raios X
14.
J Comput Assist Tomogr ; 44(6): 984-992, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33196604

RESUMO

OBJECTIVE: To compare assessment of collaterals by single-phase computed tomography (CT) angiography (CTA) and CT perfusion-derived 3-phase CTA, multiphase CTA and temporal maximum-intensity projection (tMIP) images to digital subtraction angiography (DSA), and relate collateral assessments to clinical outcome in patients with acute ischemic stroke. METHODS: Consecutive acute ischemic stroke patients who underwent CT perfusion, CTA, and DSA before thrombectomy with occlusion of the internal carotid artery, the M1 or the M2 segments were included. Two observers assessed all CT images and one separate observer assessed DSA (reference standard) with static and dynamic (modified American Society of Interventional and Therapeutic Neuroradiology) collateral grading methods. Interobserver agreement and concordance were quantified with Cohen-weighted κ and concordance correlation coefficient, respectively. Imaging assessments were related to clinical outcome (modified Rankin Scale, ≤ 2). RESULTS: Interobserver agreement (n = 101) was 0.46 (tMIP), 0.58 (3-phase CTA), 0.67 (multiphase CTA), and 0.69 (single-phase CTA) for static assessments and 0.52 (3-phase CTA) and 0.54 (multiphase CTA) for dynamic assessments. Concordance correlation coefficient (n = 80) was 0.08 (3-phase CTA), 0.09 (single-phase CTA), and 0.23 (multiphase CTA) for static assessments and 0.10 (3-phase CTA) and 0.27 (multiphase CTA) for dynamic assessments. Higher static collateral scores on multiphase CTA (odds ratio [OR], 1.7; 95% confidence interval [CI], 1.1-2.7) and tMIP images (OR, 2.0; 95% CI, 1.1-3.4) were associated with modified Rankin Scale of 2 or less as were higher modified American Society of Interventional and Therapeutic Neuroradiology scores on 3-phase CTA (OR, 1.5; 95% CI, 1.1-2.2) and multiphase CTA (OR, 1.7; 95% CI, 1.1-2.6). CONCLUSIONS: Concordance between assessments on CT and DSA was poor. Collateral status evaluated on 3-phase CTA and multiphase CTA, but not on DSA, was associated with clinical outcome.


Assuntos
Angiografia Digital/métodos , Isquemia Encefálica/diagnóstico por imagem , Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Encéfalo/diagnóstico por imagem , Isquemia Encefálica/complicações , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Estudos Retrospectivos , Acidente Vascular Cerebral/complicações
15.
Pediatr Radiol ; 50(2): 234-241, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31691845

RESUMO

BACKGROUND: Post-haemorrhagic ventricular dilatation can be measured accurately by MRI. However, two-dimensional (2-D) cranial US can be used at the bedside on a daily basis. OBJECTIVE: To assess whether the ventricular volume can be determined accurately using US. MATERIALS AND METHODS: We included 31 preterm infants with germinal matrix intraventricular haemorrhage. Two-dimensional cranial US images were acquired and the ventricular index, anterior horn width and thalamo-occipital distance were measured. In addition, cranial MRI was performed. The ventricular volume on MRI was determined using a previously validated automatic segmentation algorithm. We obtained the correlation and created a linear model between MRI-derived ventricular volume and 2-D cranial US measurements. RESULTS: The ventricular index, anterior horn width and thalamo-occipital distance as measured on 2-D cranial US were significantly associated with the volume of the ventricles as determined with MRI. A general linear model fitted the data best: ∛ventricular volume (ml) = 1.096 + 0.094 × anterior horn width (mm) + 0.020 × thalamo-occipital distance (mm) with R2 = 0.831. CONCLUSION: The volume of the lateral ventricles of infants with germinal matrix intraventricular haemorrhage can be estimated using 2-D cranial US images by application of a model.


Assuntos
Hemorragia Cerebral/diagnóstico por imagem , Ventrículos Cerebrais/diagnóstico por imagem , Ventrículos Cerebrais/patologia , Recém-Nascido Prematuro , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Hemorragia Cerebral/patologia , Feminino , Humanos , Recém-Nascido , Masculino , Tamanho do Órgão , Reprodutibilidade dos Testes
16.
Stroke ; 50(6): 1437-1443, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31092157

RESUMO

Background and Purpose- Predicting malignant middle cerebral artery (MCA) infarction can help to identify patients who may benefit from preventive decompressive surgery. We aimed to investigate the association between the ratio of intracranial cerebrospinal fluid (CSF) volume to intracranial volume (ICV) and malignant MCA infarction. Methods- Patients with an occlusion proximal to the M3 segment of the MCA were selected from the DUST (Dutch Acute Stroke Study). Admission imaging included noncontrast computed tomography (CT), CT perfusion, and CT angiography. Patient characteristics and CT findings were collected. The ratio of intracranial CSF volume to ICV (CSF/ICV) was quantified on admission thin-slice noncontrast CT. Malignant MCA infarction was defined as a midline shift of >5 mm on follow-up noncontrast CT, which was performed 3 days after the stroke or in case of clinical deterioration. To test the association between CSF/ICV and malignant MCA infarction, odds ratios and 95% CIs were calculated for 3 multivariable models by using binary logistic regression. Model performances were compared by using the likelihood ratio test. Results- Of the 286 included patients, 35 (12%) developed malignant MCA infarction. CSF/ICV was independently associated with malignant MCA infarction in 3 multivariable models: (1) with age and admission National Institutes of Health Stroke Scale (odds ratio, 3.3; 95% CI, 1.1-11.1), (2) with admission National Institutes of Health Stroke Scale and poor collateral score (odds ratio, 7.0; 95% CI, 2.6-21.3), and (3) with terminal internal carotid artery or proximal M1 occlusion and poor collateral score (odds ratio, 7.7; 95% CI, 2.8-23.9). The performance of model 1 (areas under the receiver operating characteristic curves, 0.795 versus 0.824; P=0.033), model 2 (areas under the receiver operating characteristic curves, 0.813 versus 0.850; P<0.001), and model 3 (areas under the receiver operating characteristic curves, 0.811 versus 0.856; P<0.001) improved significantly after adding CSF/ICV. Conclusions- The CSF/ICV ratio is associated with malignant MCA infarction and has added value to clinical and imaging prediction models in limited numbers of patients.

17.
Radiology ; 290(3): 833-838, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30620257

RESUMO

Purpose To develop and evaluate a dual-layer detector capable of acquiring intrinsically registered real-time fluoroscopic and nuclear images in the interventional radiology suite. Materials and Methods The dual-layer detector consists of an x-ray flat panel detector placed in front of a γ camera with cone beam collimator focused at the x-ray focal spot. This design relies on the x-ray detector absorbing the majority of the x-rays while it is more transparent to the higher energy γ photons. A prototype was built and dynamic phantom images were acquired. In addition, spatial resolution and system sensitivity (evaluated as counts detected within the energy window per second per megabecquerel) were measured with the prototype. Monte Carlo simulations for an improved system with varying flat panel compositions were performed to assess potential spatial resolution and system sensitivity. Results Experiments with the dual-layer detector prototype showed that spatial resolution of the nuclear images was unaffected by the addition of the flat panel (full width at half maximum, 13.6 mm at 15 cm from the collimator surface). However, addition of the flat panel lowered system sensitivity by 45%-60% because of the nonoptimized transmission of the flat panel. Simulations showed that an attenuation of 27%-35% of the γ rays in the flat panel could be achieved by decreasing the crystal thickness and housing attenuation of the flat panel. Conclusion A dual-layer detector was capable of acquiring real-time intrinsically registered hybrid images, which could aid interventional procedures involving radionuclides. Published under a CC BY-NC-ND 4.0 license. Online supplemental material is available for this article.


Assuntos
Fluoroscopia/instrumentação , Radiografia Intervencionista/instrumentação , Cintilografia/instrumentação , Desenho de Equipamento , Câmaras gama , Humanos , Método de Monte Carlo , Imagens de Fantasmas
18.
Cerebrovasc Dis ; 45(5-6): 279-287, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29936515

RESUMO

BACKGROUND: Predictors of recurrent ischemic stroke are less well known in patients with a recent ischemic stroke than in patients with transient ischemic attack (TIA). We identified clinical and radiological factors for predicting recurrent ischemic stroke in patients with recent ischemic stroke. METHODS: A systematic search in PubMed, Embase, Cochrane Library, and CINAHL was performed with the terms "ischemic stroke," "predictors/determinants," and "recurrence." Quality assessment of the articles was performed and the level of evidence was graded for the articles included for the meta-analysis. Pooled risk ratios (RR) and heterogeneity (I2) were calculated using inverse variance random effects models. RESULTS: Ten articles with high-quality results were identified for meta-analysis. Past medical history of stroke or TIA was a predictor of recurrent ischemic stroke (pooled RR 2.5, 95% CI 2.1-3.1). Small vessel strokes were associated with a lower risk of recurrence than large vessel strokes (pooled RR 0.3, 95% CI 0.1-0.7). Patients with stroke of an undetermined cause had a lower risk of recurrence than patients with large artery atherosclerosis (pooled RR 0.5, 95% CI 0.2-1.1). We found no studies using CT or ultrasound for the prediction of recurrent ischemic stroke. The following MRI findings were predictors of recurrent ischemic stroke: multiple lesions (pooled RR 1.7, 95% CI 1.5-2.0), multiple stage lesions (pooled RR 4.1, 95% CI 3.1-5.5), multiple territory lesions (pooled RR 2.9, 95% CI 2.0-4.2), chronic infarcts (pooled RR 1.5, 95% CI 1.2-1.9), and isolated cortical lesions (pooled RR 2.2, 95% CI 1.5-3.2). CONCLUSIONS: In patients with a recent ischemic stroke, a history of stroke or TIA and the subtype large artery atherosclerosis are associated with an increased risk of recurrent ischemic stroke. Predictors evaluated with MRI include multiple ischemic changes and isolated cortical lesions. Predictors of recurrent ischemic stroke concerning CT or ultrasound have not been published.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Ataque Isquêmico Transitório/diagnóstico por imagem , Imageamento por Ressonância Magnética , Acidente Vascular Cerebral/diagnóstico por imagem , Isquemia Encefálica/epidemiologia , Humanos , Ataque Isquêmico Transitório/epidemiologia , Valor Preditivo dos Testes , Recidiva , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia
19.
Cerebrovasc Dis ; 45(1-2): 26-32, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29402765

RESUMO

INTRODUCTION: Hemorrhagic transformation (HT) in acute ischemic stroke can occur as a result of reperfusion treatment. While withholding treatment may be warranted in patients with increased risk of HT, prediction of HT remains difficult. Nonlinear regression analysis can be used to estimate blood-brain barrier permeability (BBBP). The aim of this study was to identify a combination of clinical and imaging variables, including BBBP estimations, that can predict HT. MATERIALS AND METHODS: From the Dutch acute stroke study, 545 patients treated with intravenous recombinant tissue plasminogen activator and/or intra-arterial treatment were selected, with available admission extended computed tomography (CT) perfusion and follow-up imaging. Patient admission treatment characteristics and CT imaging parameters regarding occlusion site, stroke severity, and BBBP were recorded. HT was assessed on day 3 follow-up imaging. The association between potential predictors and HT was analyzed using univariate and multivariate logistic regression. To compare the added value of BBBP, areas under the curve (AUCs) were created from 2 models, with and without BBBP. RESULTS: HT occurred in 57 patients (10%). In univariate analysis, older age (OR 1.03, 95% CI 1.006-1.05), higher admission National Institutes of Health Stroke Scale (NIHSS; OR 1.13, 95% CI 1.08-1.18), higher clot burden (OR 1.28, 95% CI 1.16-1.41), poor collateral score (OR 3.49, 95% CI 1.85-6.58), larger Alberta Stroke Program Early CT Score cerebral blood volume deficit size (OR 1.26, 95% CI 1.14-1.38), and increased BBBP (OR 2.22, 95% CI 1.46-3.37) were associated with HT. In multivariate analysis with age and admission NIHSS, the addition of BBBP did not improve the AUC compared to both independent predictors alone (AUC 0.77, 95% CI 0.71-0.83). CONCLUSION: BBBP predicts HT but does not improve prediction with age and admission NIHSS.


Assuntos
Barreira Hematoencefálica/efeitos dos fármacos , Isquemia Encefálica/tratamento farmacológico , Permeabilidade Capilar/efeitos dos fármacos , Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada , Fibrinolíticos/efeitos adversos , Hemorragias Intracranianas/induzido quimicamente , Imagem de Perfusão/métodos , Acidente Vascular Cerebral/tratamento farmacológico , Terapia Trombolítica/efeitos adversos , Ativador de Plasminogênio Tecidual/efeitos adversos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Barreira Hematoencefálica/diagnóstico por imagem , Barreira Hematoencefálica/fisiopatologia , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/fisiopatologia , Circulação Cerebrovascular/efeitos dos fármacos , Avaliação da Deficiência , Feminino , Fibrinolíticos/administração & dosagem , Humanos , Infusões Intravenosas , Hemorragias Intracranianas/diagnóstico por imagem , Hemorragias Intracranianas/fisiopatologia , Masculino , Pessoa de Meia-Idade , Países Baixos , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/fisiopatologia , Fatores de Tempo , Ativador de Plasminogênio Tecidual/administração & dosagem , Resultado do Tratamento
20.
BMC Gastroenterol ; 18(1): 84, 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-29902988

RESUMO

BACKGROUND: Neuroendocrine tumours (NET) consist of a heterogeneous group of neoplasms with various organs of origin. At diagnosis 21% of the patients with a Grade 1 NET and 30% with a Grade 2 NET have distant metastases. Treatment with peptide receptor radionuclide therapy (PRRT) shows a high objective response rate and long median survival after treatment. However, complete remission is almost never achieved. The liver is the most commonly affected organ in metastatic disease and is the most incriminating factor for patient survival. Additional treatment of liver disease after PRRT may improve outcome in NET patients. Radioembolization is an established therapy for liver metastasis. To investigate this hypothesis, a phase 2 study was initiated to assess effectiveness and toxicity of holmium-166 radioembolization (166Ho-RE) after PRRT with lutetium-177 (177Lu)-DOTATATE. METHODS: The HEPAR PLUS trial ("Holmium Embolization Particles for Arterial Radiotherapy Plus 177 Lu-DOTATATE in Salvage NET patients") is a single centre, interventional, non-randomized, non-comparative, open label study. In this phase 2 study 30-48 patients with > 3 measurable liver metastases according to RECIST 1.1 will receive additional 166Ho-RE within 20 weeks after the 4th and last cycle of PRRT with 7.4 GBq 177Lu-DOTATATE. Primary objectives are to assess tumour response, complete and partial response according to RECIST 1.1, and toxicity, based on CTCAE v4.03, 3 months after 166Ho-RE. Secondary endpoints include biochemical response, quality of life, biodistribution and dosimetry. DISCUSSION: This is the first prospective study to combine PRRT with 177Lu-DOTATATE and additional 166Ho-RE in metastatic NET. A radiation boost on intrahepatic disease using 166Ho-RE may lead to an improved response rate without significant additional side-effects. TRIAL REGISTRATION: Clinicaltrials.gov NCT02067988 , 13 February 2014. Protocol version: 6, 30 november 2016.


Assuntos
Antineoplásicos/uso terapêutico , Embolização Terapêutica/métodos , Hólmio/uso terapêutico , Neoplasias Hepáticas/terapia , Tumores Neuroendócrinos/terapia , Octreotida/análogos & derivados , Compostos Organometálicos/uso terapêutico , Radioisótopos/uso terapêutico , Compostos Radiofarmacêuticos/uso terapêutico , Biomarcadores Tumorais , Terapia Combinada , Hólmio/efeitos adversos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Metástase Neoplásica , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/secundário , Octreotida/uso terapêutico , Qualidade de Vida , Radioisótopos/efeitos adversos , Compostos Radiofarmacêuticos/efeitos adversos , Indução de Remissão , Análise de Sobrevida
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa