Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
United European Gastroenterol J ; 8(10): 1155-1162, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32588788

RESUMO

INTRODUCTION: With increasing advances in minimally invasive endoscopic therapies and endoscopic resection techniques for luminal disease, there is an increased risk of post-procedure bleeding. This can contribute to significant burden on patient's quality of life and health resources when reintervention is required. Hemospray (Cook Medical, North Carolina, USA) is a novel haemostatic powder licensed for gastrointestinal bleeding. The aim of this single-arm, prospective, non-randomised multicentre international study is to look at outcomes in patients with upper gastrointestinal bleeds following elective endoscopic therapy treated with Hemospray to achieve haemostasis. METHODS: Data was prospectively collected on the use of Hemospray from 16 centres (January 2016-November 2019). Hemospray was used during the presence of progressive intraprocedural bleeding post-endoscopic therapy as a monotherapy, dual therapy with standard haemostatic techniques or rescue therapy once standard methods had failed. Haemostasis was defined as the cessation of bleeding within 5 min of the application of Hemospray. Re-bleeding was defined as a sustained drop in haemoglobin (>2 g/l), haematemesis or melaena with haemodynamic instability after the index endoscopy. RESULTS: A total of 73 patients were analysed with bleeding post-endoscopic therapy. The median Blatchford score at baseline was five (interquartile range 0-9). The median Rockall score was six (interquartile range 5-7). Immediate haemostasis following the application of Hemospray was achieved in 73/73 (100%) of patients. Two out of 57 (4%) had a re-bleed post-Hemospray, one was following oesophageal endoscopic mucosal resection and the other post-duodenal endoscopic mucosal resection. Both patients had a repeat endoscopy and therapy within 24 h. Re-bleeding data was missing for 16 patients, and mortality data was missing for 14 patients. There were no adverse events recorded in association with the use of Hemospray. CONCLUSION: Hemospray is safe and effective in achieving immediate haemostasis following uncontrolled and progressive intraprocedural blood loss post-endoscopic therapy, with a low re-bleed rate.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Endoscopia Gastrointestinal/efeitos adversos , Hemorragia Gastrointestinal/terapia , Hemostase Endoscópica/métodos , Hemostáticos/administração & dosagem , Minerais/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Endoscopia Gastrointestinal/métodos , Mucosa Esofágica/irrigação sanguínea , Mucosa Esofágica/diagnóstico por imagem , Mucosa Esofágica/efeitos dos fármacos , Mucosa Esofágica/cirurgia , Feminino , Mucosa Gástrica/irrigação sanguínea , Mucosa Gástrica/diagnóstico por imagem , Mucosa Gástrica/efeitos dos fármacos , Mucosa Gástrica/cirurgia , Hemorragia Gastrointestinal/etiologia , Humanos , Cuidados Intraoperatórios/métodos , Masculino , Estudos Prospectivos , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa