RESUMO
Coronary atherosclerosis is caused by plaque build-up, with lipids playing a pivotal role in its progression. However, lipid composition and distribution within coronary atherosclerosis remain unknown. This study aims to characterize lipids and investigate differences in lipid composition across disease stages to aid in the understanding of disease progression. Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) was used to visualize lipid distributions in coronary artery sections (n = 17) from hypercholesterolemic swine. We performed histology on consecutive sections to classify the artery segments and to investigate colocalization between lipids and histological regions of interest in advanced plaque, including necrotic core and inflammatory cells. Segments were classified as healthy (n = 6), mild (n = 6), and advanced disease (n = 5) artery segments. Multivariate data analysis was employed to find differences in lipid composition between the segment types, and the lipids' spatial distribution was investigated using non-negative matrix factorization (NMF). Through this process, MALDI-MSI detected 473 lipid-related features. NMF clustering described three components in positive ionization mode: triacylglycerides (TAG), phosphatidylcholines (PC), and cholesterol species. In negative ionization mode, two components were identified: one driven by phosphatidylinositol(PI)(38:4), and one driven by ceramide-phosphoethanolamine(36:1). Multivariate data analysis showed the association between advanced disease and specific lipid signatures like PC(O-40:5) and cholesterylester(CE)(18:2). Ether-linked phospholipids and LysoPC species were found to colocalize with necrotic core, and mostly CE, ceramide, and PI species colocalized with inflammatory cells. This study, therefore, uncovers distinct lipid signatures correlated with plaque development and their colocalization with necrotic core and inflammatory cells, enhancing our understanding of coronary atherosclerosis progression.
Assuntos
Doença da Artéria Coronariana , Hiperlipoproteinemia Tipo II , Placa Aterosclerótica , Animais , Suínos , Lipidômica , Ceramidas , Necrose , Fosfatidilcolinas , Éteres Fosfolipídicos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por MatrizRESUMO
BACKGROUND: Secondary lymphedema is a common complication after surgical or radiotherapeutic cancer treatment. (Micro) surgical intervention such as lymphovenous bypass and vascularized lymph node transfer is a possible solution in patients who are refractory to conventional treatment. Adequate imaging is needed to identify functional lymphatic vessels and nearby veins for surgical planning. METHODS: A systematic literature search of the Embase, MEDLINE ALL via Ovid, Web of Science Core Collection and Cochrane CENTRAL Register of Trials databases was conducted in February 2022. Studies reporting on lymphatic vessel detection in healthy subjects or secondary lymphedema of the limbs or head and neck were analyzed. RESULTS: Overall, 129 lymphatic vessel imaging studies were included, and six imaging modalities were identified. The aim of the studies was diagnosis, severity staging, and/or surgical planning. CONCLUSION: Due to its utility in surgical planning, near-infrared fluorescence lymphangiography (NIRF-L) has gained prominence in recent years relative to lymphoscintigraphy, the current gold standard for diagnosis and severity staging. Magnetic resonance lymphography (MRL) gives three-dimensional detailed information on the location of both lymphatic vessels and veins and the extent of fat hypertrophy; however, MRL is less practical for routine presurgical implementation due to its limited availability and high cost. High frequency ultrasound imaging can provide high resolution imaging of lymphatic vessels but is highly operator-dependent and accurate identification of lymphatic vessels is difficult. Finally, photoacoustic imaging (PAI) is a novel technique for visualization of functional lymphatic vessels and veins. More evidence is needed to evaluate the utility of PAI in surgical planning.
Assuntos
Vasos Linfáticos , Humanos , Vasos Linfáticos/diagnóstico por imagem , Vasos Linfáticos/cirurgiaRESUMO
Carotid atherosclerosis is a risk factor for ischemic stroke, one of the main causes of mortality and disability worldwide. The disease is characterized by plaques, heterogeneous deposits of lipids, and necrotic debris in the vascular wall, which grow gradually and may remain asymptomatic for decades. However, at some point a plaque can evolve to a high-risk plaque phenotype, which may trigger a cerebrovascular event. Lipids play a key role in the development and progression of atherosclerosis, but the nature of their involvement is not fully understood. Using matrix-assisted laser desorption/ionization mass spectrometry imaging, we visualized the distribution of approximately 200 different lipid signals, originating of >90 uniquely assigned species, in 106 tissue sections of 12 human carotid atherosclerotic plaques. We performed unsupervised classification of the mass spectrometry dataset, as well as a histology-directed multivariate analysis. These data allowed us to extract the spatial lipid patterns associated with morphological plaque features in advanced plaques from a symptomatic population, revealing spatial lipid patterns in atherosclerosis and their relation to histological tissue type. The abundances of sphingomyelin and oxidized cholesteryl ester species were elevated specifically in necrotic intima areas, whereas diacylglycerols and triacylglycerols were spatially correlated to areas containing the coagulation protein fibrin. These results demonstrate a clear colocalization between plaque features and specific lipid classes, as well as individual lipid species in high-risk atherosclerotic plaques.
Assuntos
Doenças das Artérias CarótidasRESUMO
Despite advanced understanding of the biology of atherosclerosis, coronary heart disease remains the leading cause of death worldwide. Progress has been challenging as half of the individuals who suffer sudden cardiac death do not experience premonitory symptoms. Furthermore, it is well-recognized that also a plaque that does not cause a haemodynamically significant stenosis can trigger a sudden cardiac event, yet the majority of ruptured or eroded plaques remain clinically silent. In the past 30 years since the term 'vulnerable plaque' was introduced, there have been major advances in the understanding of plaque pathogenesis and pathophysiology, shifting from pursuing features of 'vulnerability' of a specific lesion to the more comprehensive goal of identifying patient 'cardiovascular vulnerability'. It has been also recognized that aside a thin-capped, lipid-rich plaque associated with plaque rupture, acute coronary syndromes (ACS) are also caused by plaque erosion underlying between 25% and 60% of ACS nowadays, by calcified nodule or by functional coronary alterations. While there have been advances in preventive strategies and in pharmacotherapy, with improved agents to reduce cholesterol, thrombosis, and inflammation, events continue to occur in patients receiving optimal medical treatment. Although at present the positive predictive value of imaging precursors of the culprit plaques remains too low for clinical relevance, improving coronary plaque imaging may be instrumental in guiding pharmacotherapy intensity and could facilitate optimal allocation of novel, more aggressive, and costly treatment strategies. Recent technical and diagnostic advances justify continuation of interdisciplinary research efforts to improve cardiovascular prognosis by both systemic and 'local' diagnostics and therapies. The present state-of-the-art document aims to present and critically appraise the latest evidence, developments, and future perspectives in detection, prevention, and treatment of 'high-risk' plaques occurring in 'vulnerable' patients.
Assuntos
Síndrome Coronariana Aguda , Aterosclerose , Doença da Artéria Coronariana , Doença das Coronárias , Placa Aterosclerótica , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Humanos , Placa Aterosclerótica/diagnóstico por imagemRESUMO
BACKGROUND: Optical coherence tomography (OCT) can detect detailed plaque features in native coronary arteries. Stent struts cause shadows that partially obscure the vessel wall, but plaque features can still be seen. We investigated the impact of stent artefact on plaque quantification and whether the plaque behind struts is associated with microvascular dysfunction. METHODS: Patients retrospectively recruited from two centres, underwent OCT pre- and post-stenting on the same vessel segment. Lipid (LA) and calcium (CA) were measured as arcs. Macrophages, microchannels and cholesterol crystals were counted. Subsequently, we determined whether stented plaque features were associated with reduced Thrombolysis in Myocardial Infarction (TIMI) flow grade in consecutive patients who underwent OCT post-stenting. RESULTS: In 52 patients the lipid arc was similar pre- vs post-stent: median (55º [13º-93º] vs. 40º [18º-87°]; difference 1º [-7º to 16º], p = NS). Pre- and post-stent lipid were strongly correlated (r = 0.92, p < 0.001). In a further 128 patients those with reduced (TIMI ≤ II) vs normal flow post percutaneous coronary intervention (PCI) showed more plaque behind struts: lipid (89º [50º-139º] vs 62º [29º-88°]; p < 0.001); and calcium (24º [6º-45º] vs 7° [0º-34º]; p = 0.031). Multivariate logistic regression analysis showed that abnormal TIMI flow post-stenting was associated with diabetes (Odds ratio [OR] 2.87, CI 1.01-8.19, p = 0.048), LA (OR 1.29, 95% CI 1.14-1.38, p < 0.001) and CA (OR 1.26, CI 1.07-1.40, p = 0.005). CONCLUSIONS: Plaque behind the struts can be accurately quantified using OCT. Furthermore, OCT plaque features in stented segments are associated with microvascular dysfunction post PCI.
Assuntos
Artefatos , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Intervenção Coronária Percutânea/efeitos adversos , Placa Aterosclerótica/diagnóstico , Stents/efeitos adversos , Tomografia de Coerência Óptica/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/cirurgia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/etiologia , Falha de Prótese , Estudos Retrospectivos , Tomografia de Coerência Óptica/estatística & dados numéricosRESUMO
We demonstrate a tethered motorized capsule for unobstructed optical coherence tomography (OCT) imaging of the esophagus. By using a distal reflector design, we avoided the common shadow artifact induced by the motor wires. A synchronous driving technique features three types of beam-scanning modes of the capsule, i.e., circumferential beam scanning, localized beam scanning, and accurate beam positioning. We characterized these three modes and carried out ex vivo imaging experiments using the capsule. The results show that the capsule can potentially be a useful tool for diagnostic OCT imaging and OCT-guided biopsy and therapy of the esophagus.
RESUMO
Cumulative evidence from histology-based studies demonstrate that the currently available intravascular imaging techniques have fundamental limitations that do not allow complete and detailed evaluation of plaque morphology and pathobiology, limiting the ability to accurately identify high-risk plaques. To overcome these drawbacks, new efforts are developing for data fusion methodologies and the design of hybrid, dual-probe catheters to enable accurate assessment of plaque characteristics, and reliable identification of high-risk lesions. Today several dual-probe catheters have been introduced including combined near infrared spectroscopy-intravascular ultrasound (NIRS-IVUS), that is already commercially available, IVUS-optical coherence tomography (OCT), the OCT-NIRS, the OCT-near infrared fluorescence (NIRF) molecular imaging, IVUS-NIRF, IVUS intravascular photoacoustic imaging and combined fluorescence lifetime-IVUS imaging. These multimodal approaches appear able to overcome limitations of standalone imaging and provide comprehensive visualization of plaque composition and plaque biology. The aim of this review article is to summarize the advances in hybrid intravascular imaging, discuss the technical challenges that should be addressed in order to have a use in the clinical arena, and present the evidence from their first applications aiming to highlight their potential value in the study of atherosclerosis.
Assuntos
Técnicas de Imagem Cardíaca/tendências , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem Multimodal/tendências , Placa Aterosclerótica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/tendências , Angiografia Coronária/tendências , Angiofluoresceinografia/tendências , Humanos , Técnicas Fotoacústicas/tendências , Espectroscopia de Luz Próxima ao Infravermelho/tendências , Tomografia de Coerência Óptica/tendências , Ultrassonografia de Intervenção/tendênciasRESUMO
Photoacoustic imaging couples the chemical specificity of optical absorption with the viewing depth of ultrasound. Systems based on linear array transducers have the versatility to be applied in various (pre-) clinical scenarios but face a trade-off between viewing depth and image resolution depending on transducer frequency and aperture. We propose here a method to disentangle, with precision, small, closely spaced targets with optical spectral contrast, without impairing the imaging depth. Photoacoustic data sets were recorded at two different optical wavelengths. We accurately recovered object separation distances (mean error=2.3%±6%) from the phase difference between signals across the array, down to a spacing of 1/20th of the system's beam-formed lateral resolution. The proposed method may enable the translation of super-resolution microscopy to deep tissue imaging.
Assuntos
Microscopia/métodos , Técnicas Fotoacústicas/métodos , Microscopia/instrumentação , Sensibilidade e Especificidade , Análise Espectral , Transdutores , UltrassonografiaRESUMO
Photoacoustic (PA) imaging offers several attractive features as a biomedical imaging modality, including excellent spatial resolution and functional information such as tissue oxygenation. A key limitation, however, is the contrast to noise ratio that can be obtained from tissue depths greater than 1-2 mm. Microbubbles coated with an optically absorbing shell have been proposed as a possible contrast agent for PA imaging, offering greater signal amplification and improved biocompatibility compared to metallic nanoparticles. A theoretical description of the dynamics of a coated microbubble subject to laser irradiation has been developed previously. The aim of this study was to test the predictions of the model. Two different types of oil-coated microbubbles were fabricated and then exposed to both pulsed and continuous wave (CW) laser irradiation. Their response was characterized using ultra high-speed imaging. Although there was considerable variability across the population, good agreement was found between the experimental results and theoretical predictions in terms of the frequency and amplitude of microbubble oscillation following pulsed excitation. Under CW irradiation, highly nonlinear behavior was observed which may be of considerable interest for developing different PA imaging techniques with greatly improved contrast enhancement.
RESUMO
Microbubbles are used to enhance the contrast in ultrasound imaging. When coated with an optically absorbing material, these bubbles can also provide contrast in photoacoustic imaging. This multimodal aspect is of pronounced interest to the field of medical imaging. The aim of this paper is to provide a theoretical framework to describe the physical phenomena underlying the photoacoustic response. This article presents a model for a spherical gas microbubble suspended in an aqueous environment and coated with an oil layer containing an optically absorbing dye. The model includes heat transfer between the gas core and the surrounding liquids. This framework is suitable for the investigation of both continuous wave and pulsed laser excitation. This work utilizes a combination of finite difference simulations and numerical integration to determine the dependancy on the physical properties, including composition and thickness of the oil layer on the microbubble response. A normalization scheme for a linearized version of the model was derived to facilitate comparison with experimental measurements. The results show that viscosity and thickness of the oil layer determine whether or not microbubble resonance can be excited. This work also examines the use of non-sinusoidal excitation to promote harmonic imaging techniques to further improve the imaging sensitivity.
RESUMO
A basic requirement for intravascular photoacoustic (IVPA) imaging catheters is that the delivery of light lies within the ultrasonic field of view. Size and manufacturing constraints favor probe designs with offset optical and acoustic beams. This noncollinear dual beam arrangement leads to a curved PA point spread function (PSF). In this work, we characterize the three-dimensional shape of the PSF for IVPA imaging in clear and optically scattering media. We show that the product of the two beam profiles can accurately model the measured peak response in clear and scattering media. We discuss the impact of the PSF shape and its relation to probe construction. We test the imaging capability of the catheter on a phantom and a human artery ex vivo.
Assuntos
Desenho Assistido por Computador , Vasos Coronários/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/instrumentação , Técnicas Fotoacústicas/instrumentação , Ultrassonografia de Intervenção/instrumentação , Dispositivos de Acesso Vascular , Cateteres Cardíacos , Ecocardiografia/instrumentação , Ecocardiografia/métodos , Técnicas de Imagem por Elasticidade/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imagens de Fantasmas , Técnicas Fotoacústicas/métodos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
Spectral photoacoustic imaging in combination with unmixing techniques may be applied to retrieve information about high-risk features present in atherosclerotic plaques, possibly providing prognostic insights into future stroke events. We present the photoacoustic spectral contrast found in 12 systematically scanned advanced atherosclerotic plaques in the near-infrared wavelength range (850-1250â¯nm). The main absorbers are lipid, water, and hemoglobin, with the highest photoacoustic intensities at the lipid's second overtone at 1190 and 1210â¯nm. Linear unmixing resulted in visualizing regions with high lipid and hemoglobin absorption, corresponding to the histological presence of lipid and intraplaque hemorrhage. A non-negative matrix factorization approach reveals differences in lipid spectral contrast, providing potential insights into the vulnerability of atherosclerotic plaque. These results provide a reference for future, more complex, in vivo photoacoustic imaging of carotid artery atherosclerosis, potentially contributing to assessing the risk of future events and treatment decision.
RESUMO
Multimodal intravascular ultrasound and photoacoustic (IVUS/PA) imaging is a promising diagnostic tool for cardiovascular diseases like atherosclerosis. IVUS/PA catheters typically require two independent transducers due to different frequency requirements, potentially increasing the catheter size. To facilitate multimodal imaging within conventional catheter dimensions, we designed, fabricated, and characterized a dual-transducer acoustic stack where a low-frequency (LF) PA receiver sits as a matching layer for the high-frequency (HF) US transducer. While the HF transducer operates around 50 MHz, the LF receiver targets frequencies below 15 MHz to capture most of the PA energy from atherosclerotic plaque lipids. Simulation results reveal that this configuration could increase the sensitivity of the HF transducer by 3.54 dB while maintaining bandwidth. Phantom experiments with fabricated stacks showed improved performance for the US transducer, validating the enhanced sensitivity and bandwidth. Following improvements in stack fabrication, the proposed acoustic stack is a viable design that can significantly enhance diagnostic accuracy for atherosclerosis, providing high-resolution, multifrequency imaging within a compact catheter form factor.
RESUMO
Intravascular ultrasound and optical coherence tomography are used with increasing frequency for the care of coronary patients and in research studies. These imaging tools can identify culprit lesions in acute coronary syndromes, assess coronary stenosis severity, guide percutaneous coronary intervention (PCI), and detect vulnerable plaques and patients. However, they have significant limitations that have stimulated the development of multimodality intracoronary imaging catheters, which provide improvements in assessing vessel wall pathology and guiding PCI. Prototypes combining 2 or even 3 imaging probes with complementary attributes have been developed, and several multimodality systems have already been used in patients, with near-infrared spectroscopy intravascular ultrasound-based studies showing promising results for the identification of high-risk plaques. Moreover, postmortem histology studies have documented that hybrid imaging catheters can enable more accurate characterization of plaque morphology than standalone imaging. This review describes the evolution in the field of hybrid intracoronary imaging; presents the available multimodality catheters; and discusses their potential role in PCI guidance, vulnerable plaque detection, and the assessment of endovascular devices and emerging pharmacotherapies targeting atherosclerosis.
Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Imagem Multimodal , Intervenção Coronária Percutânea , Placa Aterosclerótica , Valor Preditivo dos Testes , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Intervenção Coronária Percutânea/instrumentação , Desenho de Equipamento , Cateteres Cardíacos , Difusão de Inovações , Cateterismo Cardíaco/instrumentação , Espectroscopia de Luz Próxima ao Infravermelho , AnimaisRESUMO
Due to the shortage of kidneys donated for transplantation, surgeons are forced to use the organs with an elevated risk of poor function or even failure. Although the existing methods for pre-transplant quality evaluation have been validated over decades in population cohort studies across the world, new methods are needed as long as delayed graft function or failure in a kidney transplant occurs. In this study, we explored the potential of utilizing photoacoustic (PA) imaging during normothermic machine perfusion (NMP) as a means of evaluating kidney quality. We closely monitored twenty-two porcine kidneys using 3D PA imaging during a two-hour NMP session. Based on biochemical analyses of perfusate and produced urine, the kidneys were categorized into 'non-functional' and 'functional' groups. Our primary focus was to quantify oxygenation (sO2) within the kidney cortical layer of depths 2 mm, 4 mm, and 6 mm using two-wavelength PA imaging. Next, receiver operating characteristic (ROC) analysis was performed to determine an optimal cortical layer depth and time point for the quantification of sO2 to discriminate between functional and non-functional organs. Finally, for each depth, we assessed the correlation between sO2 and creatinine clearance (CrCl), oxygen consumption (VO2), and renal blood flow (RBF). We found that hypoxia of the renal cortex is associated with poor renal function. In addition, the determination of sO2 within the 2 mm depth of the renal cortex after 30 min of NMP effectively distinguishes between functional and non-functional kidneys. The non-functional kidneys can be detected with the sensitivity and specificity of 80% and 85% respectively, using the cut-off point of sO2 < 39%. Oxygenation significantly correlates with RBF and VO2 in all kidneys. In functional kidneys, sO2 correlated with CrCl, which is not the case for non-functional kidneys. We conclude that the presented technique has a high potential for supporting organ selection for kidney transplantation.
RESUMO
The presence of lipids in atherosclerotic coronary lesions is an important determinant of their potential to trigger acute coronary events. Spectroscopic intravascular photoacoustic imaging (sIVPA) has the potential to automatically detect lipids in atherosclerotic lesions. For real-time in vivo imaging, limiting the number of excitation wavelengths is crucial. We explored methods for plaque lipid detection using sIVPA, with the aim to minimize the number of laser pulses per image line. A combined intravascular ultrasound (IVUS) and photoacoustic imaging system was used to image a vessel phantom and human coronary arteries ex vivo. We acquired co-registered cross-sectional images at several wavelengths near 1200 nm, a lipid-specific absorption band. Correlating the photoacoustic spectra at 6 or 3 wavelengths from 1185 to 1235 nm with the absorption spectrum of cholesterol and peri-adventitial tissue, we could detect and differentiate the lipids in the atherosclerotic plaque and peri-adventitial lipids, respectively. With two wavelengths, both plaque and peri-adventitial lipids were detected but could not be distinguished.
Assuntos
Vasos Coronários/metabolismo , Lipídeos/análise , Técnicas Fotoacústicas/métodos , Placa Aterosclerótica/diagnóstico , Análise Espectral/métodos , Humanos , Imagens de FantasmasRESUMO
We demonstrate intravascular optical coherence tomography (OCT) imaging with frame rate up to 3.2 kHz (192,000 rpm scanning). This was achieved by using a custom-built catheter in which the circumferential scanning was actuated by a 1.0 mm diameter synchronous motor. The OCT system, with an imaging depth of 3.7 mm (in air), is based on a Fourier domain mode locked laser operating at an A-line rate of 1.6 MHz. The diameter of the catheter is 1.1 mm at the tip. Ex vivo images of human coronary artery (78.4 mm length) were acquired at a pullback speed of 100 mm/s. True 3D volumetric imaging of the entire artery, with dense and isotropic sampling in all dimensions, was performed in <1 second acquisition time.
Assuntos
Vasos Coronários , Tomografia de Coerência Óptica/métodos , Catéteres , Análise de Fourier , Coração/fisiologia , Humanos , Fatores de Tempo , Tomografia de Coerência Óptica/instrumentaçãoRESUMO
Significance: Spectroscopic analysis of optical coherence tomography (OCT) data can yield added information about the sample's chemical composition, along with high-resolution images. Typical commercial OCT systems operate at wavelengths that may not be optimal for identifying lipid-containing samples based on absorption features. Aim: The main aim of this study was to develop a 1200 nm spectroscopic OCT (SOCT) for the classification of lipid-based and water-based samples by extracting the lipid absorption peak at 1210 nm from the OCT data. Approach: We developed a 1200 nm OCT system and implemented a signal processing algorithm that simultaneously retrieves spectroscopic and structural information from the sample. In this study, we validated the performance of our OCT system by imaging weakly scattering phantoms with and without lipid absorption features. An orthogonal projections to latent structures-discriminant analysis (OPLS-DA) model was developed and applied to classify weakly scattering samples based on their absorption features. Results: The OCT system achieved an axial resolution of 7.2 µm and a sensitivity of 95 dB. The calibrated OPLS-DA model on weakly scattering samples with lipid and water-based absorption features correctly classified 19/20 validation samples. Conclusions: The 1200 nm SOCT system can discriminate the lipid-containing weakly scattering samples from water-based weakly scattering samples with good predictive ability.
Assuntos
Análise Espectral , Tomografia de Coerência Óptica , Humanos , Lipídeos/análise , Água , Processamento de Imagem Assistida por ComputadorRESUMO
Significance: Photoacoustic imaging (PAI) enables the visualization of optical contrast with ultrasonic imaging. It is a field of intense research, with great promise for clinical application. Understanding the principles of PAI is important for engineering research and image interpretation. Aim: In this tutorial review, we lay out the imaging physics, instrumentation requirements, standardization, and some practical examples for (junior) researchers, who have an interest in developing PAI systems and applications for clinical translation or applying PAI in clinical research. Approach: We discuss PAI principles and implementation in a shared context, emphasizing technical solutions that are amenable to broad clinical deployment, considering factors such as robustness, mobility, and cost in addition to image quality and quantification. Results: Photoacoustics, capitalizing on endogenous contrast or administered contrast agents that are approved for human use, yields highly informative images in clinical settings, which can support diagnosis and interventions in the future. Conclusion: PAI offers unique image contrast that has been demonstrated in a broad set of clinical scenarios. The transition of PAI from a "nice-to-have" to a "need-to-have" modality will require dedicated clinical studies that evaluate therapeutic decision-making based on PAI and consideration of the actual value for patients and clinicians, compared with the associated cost.