Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 41(6): 578-582, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29577341

RESUMO

BACKGROUND: Intraoperative controlled mechanical ventilation (CMV) changes the intrathoracic geometry and may impact postoperative left ventricular (LV) lead function after CRT implantation. This multicenter study investigates the effect of intraoperative ventilation setting (spontaneous breathing [SB] vs CMV) on postoperative LV lead function taking into account patients' body mass index (BMI). METHODS: CRT implantation was performed at two centers during SB in 92 and during CMV in 73 patients. Follow-up was carried out after 3 ± 5 and 36 ± 53 days. Functional lead parameters (FLP; pacing threshold and impedance), postoperative adverse events (A;  phrenic nerve stimulation [PNS] and lead malfunction), and patients' BMI were assessed. Delta values of FLP between baseline and follow-up visits were analyzed applying an analysis of covariance model to detect subclinical alterations in LV lead function. RESULTS: AE occurred in a total of 36 (21%) patients. PNS was observed in 26 (15%) patients and LV lead repositioning due to malfunction was necessary in 10 (6%) patients. Both AE and FLP delta values between baseline and follow-up were not associated with intraoperative ventilation settings nor the patients' BMI. CONCLUSIONS: This study demonstrates that there is no impact of the intraoperative ventilation setting (SB vs CMV) on postoperative FLP or the occurrence of AE. This is also the case taking into account the BMI. With respect to these findings both approaches-sedation only or general anaesthesia including CMV-can be safely implemented during CRT implantation.


Assuntos
Terapia de Ressincronização Cardíaca , Cuidados Intraoperatórios , Respiração Artificial , Idoso , Índice de Massa Corporal , Ecocardiografia , Eletrocardiografia , Feminino , Alemanha , Humanos , Masculino , Respiração Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
2.
J Ultrasound Med ; 37(5): 1091-1101, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29034496

RESUMO

OBJECTIVES: Microembolic signal detection by transcranial Doppler ultrasonography may be considered a surrogate for cerebral events during invasive cardiac procedures. However, the impact of the microembolic signal count during pulmonary vein isolation on the clinical outcome is not well evaluated. We investigated the effect of the microembolic signal count on the occurrence of new silent cerebral embolism measured by diffusion-weighted imaging (DWI)-magnetic resonance imaging (MRI), changes in neuropsychological testing, and the occurrence of clinical events during long-term follow-up after pulmonary vein isolation. METHODS: Pulmonary vein isolation was performed in 41 patients. The total microembolic signal burden (classified into "solid," "gaseous," and "equivocal") and sustained thromboembolic showers of greater than 30 seconds were recorded. Diffusion-weighted imaging-MRI and neuropsychological testing were performed before and after pulmonary vein isolation to assess for silent cerebral embolism and neuropsychological sequelae. Long-term follow-up was performed by telephone to assess for stroke/transient ischemic attack. RESULTS: A total of 68,729 microembolic signals (14,893 solid, 11,909 gaseous, and 41,927 equivocal) with an average of 1676 signals per patient and 42 thromboembolic showers were recorded. No correlation between the microembolic signal/thromboembolic shower count and the occurrence of new DWI lesions or neuropsychological capability was found. After a mean follow-up ± SD of 49 ± 4 months, 1 patient had an overt transient ischemic event, which was not associated with a high microembolic signal count. CONCLUSIONS: In this multicenter study, we found no impact of the intraprocedural microembolic symbol/thromboembolic shower count on the occurrence of new DWI lesions, neuropsychological capability, or overt neurologic deficits after pulmonary vein isolation. Thus, not only the microembolic signal count but also procedural/individual factors may contribute to commensurable clinical damage, which may challenge this method as a valid biomarker during pulmonary vein isolation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Embolia Intracraniana/diagnóstico , Veias Pulmonares/fisiopatologia , Processamento de Sinais Assistido por Computador , Ultrassonografia Doppler Transcraniana/métodos , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Embolia Intracraniana/complicações , Embolia Intracraniana/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Testes Neuropsicológicos , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Fatores de Risco
3.
Europace ; 16(1): 26-32, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23744849

RESUMO

AIMS: We investigated predictors of left atrial volume reduction (LAVR) in patients with atrial fibrillation (AF) undergoing AF ablation. METHODS AND RESULTS: Sixty patients with AF underwent pulmonary vein isolation (PVI) using a pulmonary vein ablation catheter (PVAC). All patients underwent cardiac imaging by computed tomography or magnetic resonance imaging to determine LAV 1 day before and 140 ± 9.5 days after PVI. Clinical follow-up and 72 h electrocardiogram Holter monitoring were performed 1, 3, and 6 months after ablation, and every 6 months thereafter. Significant LAVR (n = 60, 89.3 ± 3.9 vs. 79.5 ± 3.6 mL, P < 0.0001) was shown for the study group as a whole, caused particularly by the subgroup of patients with ablation success (n = 45, 85.2 ± 4.6 vs. 72.5 ± 3.7 mL, P < 0.0001). In addition, significant LAVR was shown for patients with lone AF (n = 25, 88.8 ± 6.8 vs. 72.7 ± 5.3 mL, P < 0.0001), but not for patients with AF and concomitant arterial hypertension (n = 32, 89 ± 4.8 vs. 86.7 ± 5 mL, P = 0.3), coronary artery disease (n = 12, 91.6 ± 7.8 vs. 89.1 ± 7.8 mL, P = 0.26), or left ventricular hypertrophy (n = 10, 86.3 ± 5.5 vs. 83.1 ± 5.3 mL, P = 0.27). Multivariate analysis revealed absence of arterial hypertension, lone AF, ablation success, and initial LA enlargement as independent predictors for significant LAVR following ablation (each P < 0.05). CONCLUSION: Based on the subgroup of patients with lone AF, PVI leads to a significant LAVR 4 months after the procedure, especially in patients with clinical success in terms of AF freedom. Comorbidities such as arterial hypertension may prevent this reverse atrial remodelling, despite AF freedom. Clinical implications need to be further elucidated.


Assuntos
Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Fibrilação Atrial/diagnóstico , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Prognóstico , Recidiva , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
4.
Europace ; 15(12): 1741-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23736806

RESUMO

AIMS: To provide a nationwide survey (and reference for the future) on cardiac electrophysiologists, types and numbers of invasive electrophysiological procedures, and training opportunities in 2010. METHODS AND RESULTS: German cardiology centres performing invasive electrophysiology were identified from quality reports and contacted to fill a questionnaire. A majority of 122 centres (65%) responded. Electrophysiology (ablation procedures and device therapy) was mainly part of a cardiology department (82%), and only in 9% independent (own budget). In only 58% of the centres, (at least) two physicians were present during catheter ablations. Although in 2010, women represented 59.4% of physicians <35 years old, only 26% of physicians in electrophysiology training were female. In total, 33 420 catheter ablations were performed with a median number of 180 per centre. Atrial fibrillation (AF) was the most common arrhythmia invasively treated (35%). At least 50 AF ablations were performed in 53% of the centres. Of the centres performing AF ablations, consecutive left atrial arrhythmias were treated by catheter ablation only in 75%, and only 44% had in-house surgical backup. Only one-fourth of the 122 centres fulfilled all requirements for training centre accreditation according to the European Heart Rhythm Association and the German Cardiac Society. CONCLUSION: The results indicate a high number of electrophysiology centres and procedures in Germany. Atrial fibrillation was the most common arrhythmia invasively treated. An increasing demand for catheter ablation is likely, but training opportunities are limited. Women are clearly underrepresented. A co-operation of higher and lower volume electrophysiology centres may be necessary for training purposes.


Assuntos
Arritmias Cardíacas/terapia , Serviço Hospitalar de Cardiologia/tendências , Cardiologia/tendências , Ablação por Cateter/tendências , Educação de Pós-Graduação em Medicina/tendências , Técnicas Eletrofisiológicas Cardíacas/tendências , Acreditação/tendências , Adulto , Arritmias Cardíacas/diagnóstico , Cardiologia/educação , Serviço Hospitalar de Cardiologia/estatística & dados numéricos , Ablação por Cateter/estatística & dados numéricos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Feminino , Alemanha , Pesquisas sobre Atenção à Saúde , Hospitais com Alto Volume de Atendimentos/tendências , Hospitais com Baixo Volume de Atendimentos/tendências , Humanos , Masculino , Médicas/tendências , Avaliação de Programas e Projetos de Saúde , Inquéritos e Questionários , Fatores de Tempo , Recursos Humanos
5.
Pacing Clin Electrophysiol ; 36(4): 477-85, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23379955

RESUMO

BACKGROUND: We investigate the frequency of esophageal tissue injury (ETI) following ablation of atrial fibrillation (AF) using the pulmonary vein ablation catheter (PVAC) ascertained by esophageal endoscopy (ESE) and corresponding magnetic resonance imaging (MRI). METHODS: A total of 41 patients with symptomatic AF presenting for pulmonary vein isolation (PVI) were included consecutively in two observational groups. Group A received MRI the day before and ESE plus MRI within 3-4 weeks following the ablation procedure using the PVAC. Group B received MRI the day before and ESE plus MRI within 2 days after PVI. MRI included T2-weighted and T1-weighted postcontrast with fat suppression (fs) and late-enhancement scans to demonstrate postprocedural edema and contrast enhancement of the esophageal wall. RESULTS: A total of 13 (32%) patients were enrolled in Group A (26 ± 11 days post-PVI), and 28 (68%) patients in Group B (2 ± 0.6 days post-PVI). ETI was found by ESE in one (2%) patient (Group B) and resolved under conservative therapy. Corresponding MRI showed a false negative result with no alterations of esophageal structures using T1-weighted, T2-weighted, and late enhancement scans. In addition, false positive results were demonstrated by late-enhancement MRI in five (12%) patients (three patients in Group A and two patients in Group B), which could not be verified by corresponding ESE. CONCLUSIONS: Endoluminal ETI is a rare but possible complication, which should be considered following PVAC procedures. MRI of the esophagus is currently not a reliable screening method due to false positive and negative findings compared to ESE.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Esofagoscopia/métodos , Esôfago/lesões , Imageamento por Ressonância Magnética/métodos , Veias Pulmonares/cirurgia , Meios de Contraste , Angiografia Coronária , Ecocardiografia Transesofagiana , Esôfago/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Prospectivos
6.
Telemed J E Health ; 19(6): 460-6, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23570275

RESUMO

OBJECTIVE: Implantable cardioverter-defibrillators (ICDs) alone or combined with cardiac resynchronization therapy (CRT-Ds) featuring automatic home monitoring (HM) function can be monitored remotely on a daily basis. Different ways of implementing HM into clinical routines are possible, with efficient patient management being the main objective. In this study, a concept using a telemedical service center (TmSC) to manage HM data was developed and investigated regarding patients' satisfaction, physicians' satisfaction, and alert filtering. SUBJECTS AND METHODS: Fifty-five ICD or CRT-D patients with symptomatic heart failure were enrolled. The TmSC received HM data, identified "actionable parameters" (APs) by following protocol-defined procedures, conducted structured patient interviews, and forwarded selected APs to the respective follow-up clinic. Satisfaction of patients and physicians with the TmSC was evaluated at the end of the study by purpose-designed questionnaires. RESULTS: During a mean follow-up of 402±200 days, 3,831 APs were identified and analyzed at the TmSC (5.28 per patient-month). Most APs were triggered by a pilot detection algorithm for worsening heart failure (2.80 per patient-month), followed by atrial tachyarrhythmia episodes (1.10 per patient-month) and ventricular pacing issues (0.87 per patient-month). The TmSC forwarded 682 APs (18% of all APs) to 10 study sites. Approximately 65% of physicians and patients deemed the TmSC improved patient care. CONCLUSIONS: The TmSC-based management concept was well accepted and appreciated by the majority of physicians and patients. It may be helpful in gaining symptomatic information on top of automatic HM data and in supporting smaller clinics in the follow-up of their device patients.


Assuntos
Desfibriladores Implantáveis , Gestão da Informação em Saúde , Insuficiência Cardíaca/terapia , Centros de Informação , Monitorização Fisiológica/métodos , Telemetria , Idoso , Congressos como Assunto , Comportamento do Consumidor , Diagnóstico Precoce , Feminino , Alemanha , Humanos , Masculino , Projetos Piloto
7.
J Magn Reson Imaging ; 36(6): 1362-71, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22865680

RESUMO

PURPOSE: To accelerate the acquisition of three-dimensional (3D) high-resolution cardiovascular molecular MRI by using Compressed Sensing (CS) reconstruction. MATERIALS AND METHODS: Molecular MRI is an emerging technique for the early assessment of cardiovascular disease. This technique provides excellent soft tissue differentiation at a molecular and cellular level using target-specific contrast agents (CAs). However, long scan times are required for 3D molecular MRI. Parallel imaging can be used to speed-up these acquisitions, but hardware considerations limit the maximum acceleration factor. This limitation is important in small-animal studies, where single-coils are commonly used. Here we exploit the sparse nature of molecular MR images, which are characterized by localized and high-contrast biological target-enhancement, to accelerate data acquisition. CS was applied to detect: (a) venous thromboembolism and (b) coronary injury and aortic vessel wall in single- and multiple-coils acquisitions, respectively. RESULTS: Retrospective undersampling showed good overall image quality with accelerations up to four for thrombus and aortic images, and up to three for coronary artery images. For higher acceleration factors, features with high CA uptake were still well recovered while low affinity targets were less preserved with increased CS undersampling artifacts. Prospective undersampling was performed in an aortic image with acceleration of two, showing good contrast and well-defined tissue boundaries in the contrast-enhanced regions. CONCLUSION: We demonstrate the successful application of CS to preclinical molecular MR with target specific gadolinium-based CAs using retrospective (accelerations up to four) and prospective (acceleration of two) undersampling.


Assuntos
Compressão de Dados/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Imagem Molecular/métodos , Infarto do Miocárdio/patologia , Disfunção Ventricular Esquerda/patologia , Algoritmos , Animais , Meios de Contraste/farmacocinética , Feminino , Gadolínio DTPA/farmacocinética , Aumento da Imagem/métodos , Camundongos , Camundongos Endogâmicos C57BL , Infarto do Miocárdio/complicações , Infarto do Miocárdio/metabolismo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/metabolismo
8.
Circulation ; 122(22): 2239-45, 2010 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-21098435

RESUMO

BACKGROUND: Cryoablation has emerged as an alternative to radiofrequency catheter ablation (RFCA) for the treatment of atrioventricular (AV) nodal reentrant tachycardia (AVNRT). The purpose of this prospective randomized study was to test whether cryoablation is as effective as RFCA during both short-term and long-term follow-up with a lower risk of permanent AV block. METHODS AND RESULTS: A total of 509 patients underwent slow pathway cryoablation (n=251) or RFCA (n=258). The primary end point was immediate ablation failure, permanent AV block, and AVNRT recurrence during a 6-month follow-up. Secondary end points included procedural parameters, device functionality, and pain perception. Significantly more patients in the cryoablation group than the RFCA group reached the primary end point (12.6% versus 6.3%; P=0.018). Whereas immediate ablation success (96.8% versus 98.4%) and occurrence of permanent AV block (0% versus 0.4%) did not differ, AVNRT recurrence was significantly more frequent in the cryoablation group (9.4% versus 4.4%; P=0.029). In the cryoablation group, procedure duration was longer (138±54 versus 123±48 minutes; P=0.0012) and more device problems occurred (13 versus 2 patients; P=0.033). Pain perception was lower in the cryoablation group (P<0.001). CONCLUSIONS: Cryoablation for AVNRT is as effective as RFCA over the short term but is associated with a higher recurrence rate at the 6-month follow-up. The risk of permanent AV block does not differ significantly between cryoablation and RFCA. The potential benefits of cryoenergy relative to ablation safety and pain perception are counterbalanced by longer procedure times, more device problems, and a high recurrence rate. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00196222.


Assuntos
Ablação por Cateter/métodos , Criocirurgia/métodos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adulto , Idoso , Bloqueio Atrioventricular/epidemiologia , China , Determinação de Ponto Final , Europa (Continente) , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Taquicardia por Reentrada no Nó Atrioventricular/mortalidade , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 34(8): 975-83, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21438891

RESUMO

BACKGROUND: Right ventricular pacing predisposes to the development of heart failure and atrial fibrillation. Automatic atrioventricular search hysteresis (AVSH) is a commonly used strategy to decrease the percentage of right ventricular pacing (%VP) in patients without permanent AV block, but the results have not been optimal. METHODS: The randomized, crossover PREVENT study evaluated whether an enhanced AVSH with two new features can reduce %VP compared with standard AVSH. The new features are the repetitive hysteresis [switch from extended to basic AV delay after a consistent loss of intrinsic AV conduction (IAVC) lasting for six consecutive atrial cycles] and the scan hysteresis (periodic IAVC search extension over six consecutive atrial cycles). Both standard AVSH and enhanced AVSH performed a periodic IAVC search every 180 cardiac cycles and operated with a basic AV-delay of 225 ms and a rate-independent maximum AV-delay of 300 ms for paced and sensed atrial events. RESULTS: Among 178 patients, 53.4% had no evidence of AV block at enrollment and 46.6% had history of intermittent AV block. The median %VP was decreased by enhanced AVSH compared to standard AVSH (4.0% vs 5.5%, P < 0.001), particularly in patients with a history of AV block (21.4% vs 25.5%, P < 0.001). The primary study hypothesis that 25% of all patients would experience > 20% relative %VP reduction was not met as 46 (25.8%) patients (95% confidence interval, 20.5-31.8%) presented such relative reduction. CONCLUSION: The enhanced AVSH algorithm reduces %VP compared with standard AVSH in patients with intermittent AV block.


Assuntos
Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial , Ventrículos do Coração/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Nó Atrioventricular/fisiopatologia , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial
10.
Lancet Respir Med ; 9(8): 863-872, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34126053

RESUMO

BACKGROUND: SARS-CoV-2 entry in human cells depends on angiotensin-converting enzyme 2, which can be upregulated by inhibitors of the renin-angiotensin system (RAS). We aimed to test our hypothesis that discontinuation of chronic treatment with ACE-inhibitors (ACEIs) or angiotensin II receptor blockers (ARBs) mitigates the course o\f recent-onset COVID-19. METHODS: ACEI-COVID was a parallel group, randomised, controlled, open-label trial done at 35 centres in Austria and Germany. Patients aged 18 years and older were enrolled if they presented with recent symptomatic SARS-CoV-2 infection and were chronically treated with ACEIs or ARBs. Patients were randomly assigned 1:1 to discontinuation or continuation of RAS inhibition for 30 days. Primary outcome was the maximum sequential organ failure assessment (SOFA) score within 30 days, where death was scored with the maximum achievable SOFA score. Secondary endpoints were area under the death-adjusted SOFA score (AUCSOFA), mean SOFA score, admission to the intensive care unit, mechanical ventilation, and death. Analyses were done on a modified intention-to-treat basis. This trial is registered with ClinicalTrials.gov, NCT04353596. FINDINGS: Between April 20, 2020, and Jan 20, 2021, 204 patients (median age 75 years [IQR 66-80], 37% females) were randomly assigned to discontinue (n=104) or continue (n=100) RAS inhibition. Within 30 days, eight (8%) of 104 died in the discontinuation group and 12 (12%) of 100 patients died in the continuation group (p=0·42). There was no significant difference in the primary endpoint between the discontinuation and continuation group (median [IQR] maximum SOFA score 0·00 (0·00-2·00) vs 1·00 (0·00-3·00); p=0·12). Discontinuation was associated with a significantly lower AUCSOFA (0·00 [0·00-9·25] vs 3·50 [0·00-23·50]; p=0·040), mean SOFA score (0·00 [0·00-0·31] vs 0·12 [0·00-0·78]; p=0·040), and 30-day SOFA score (0·00 [10-90th percentile, 0·00-1·20] vs 0·00 [0·00-24·00]; p=0·023). At 30 days, 11 (11%) in the discontinuation group and 23 (23%) in the continuation group had signs of organ dysfunction (SOFA score ≥1) or were dead (p=0·017). There were no significant differences for mechanical ventilation (10 (10%) vs 8 (8%), p=0·87) and admission to intensive care unit (20 [19%] vs 18 [18%], p=0·96) between the discontinuation and continuation group. INTERPRETATION: Discontinuation of RAS-inhibition in COVID-19 had no significant effect on the maximum severity of COVID-19 but may lead to a faster and better recovery. The decision to continue or discontinue should be made on an individual basis, considering the risk profile, the indication for RAS inhibition, and the availability of alternative therapies and outpatient monitoring options. FUNDING: Austrian Science Fund and German Center for Cardiovascular Research.


Assuntos
Antagonistas de Receptores de Angiotensina , Inibidores da Enzima Conversora de Angiotensina , COVID-19 , Hipertensão , Sistema Renina-Angiotensina , SARS-CoV-2 , Antagonistas de Receptores de Angiotensina/administração & dosagem , Antagonistas de Receptores de Angiotensina/efeitos adversos , Enzima de Conversão de Angiotensina 2/metabolismo , Inibidores da Enzima Conversora de Angiotensina/administração & dosagem , Inibidores da Enzima Conversora de Angiotensina/efeitos adversos , Área Sob a Curva , COVID-19/epidemiologia , COVID-19/metabolismo , COVID-19/terapia , Feminino , Humanos , Hipertensão/tratamento farmacológico , Hipertensão/epidemiologia , Masculino , Pessoa de Meia-Idade , Escores de Disfunção Orgânica , Avaliação de Processos e Resultados em Cuidados de Saúde , Sistema Renina-Angiotensina/efeitos dos fármacos , Sistema Renina-Angiotensina/fisiologia , Risco Ajustado/métodos , SARS-CoV-2/efeitos dos fármacos , SARS-CoV-2/fisiologia , Índice de Gravidade de Doença , Suspensão de Tratamento/estatística & dados numéricos
11.
J Cardiovasc Electrophysiol ; 20(10): 1097-101, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19493155

RESUMO

BACKGROUND: Ablation of atrial fibrillation (AF) has been one of the most difficult and time-consuming electrophysiological procedures. Due to the rapidly increasing demand for ablation procedures, technical advances would be helpful to reduce complexity and procedure time in AF ablation. Therefore, we investigated the feasibility of a single-catheter technique for pulmonary vein (PV) isolation utilizing a decapolar catheter combined with a duty-cycled, unipolar-bipolar radiofrequency (RF) generator. METHODS: AF mapping and ablation was performed in 21 consecutive patients (mean age 59 +/- 12 years, 9 males) with paroxysmal AF (n = 17) and persistent AF (n = 4). The ablation catheter was forwarded to the LA via single-transseptal puncture. All electrodes were energized in 2 to 5 applications per vein, followed by segmental RF applications, as needed, to achieve electrical isolation. To assess left atrial anatomy for purposes of catheter manipulation, and later evaluate the possibility of asymptomatic PV-stenosis, CT or MR imaging was performed both prior to ablation and at 6-month follow-up. RESULTS: Isolation could be achieved in 85/86 veins (99%). Procedure time for ablation was 81 +/- 13 minutes, and fluoroscopy time was 30 +/- 11 minutes. There were no procedural complications. Success rate at 6 months was 86% (18/21). MR or CT imaging excluded asymptomatic PV-stenosis. CONCLUSION: Mapping and ablation of PVs can be performed in a safe and efficient manner using a single-catheter technique, with short procedure times and minimal learning curve. Thus, this system may be of high interest not only for high volume but all centers performing AF ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Transdutores , Adulto , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ondas de Rádio
12.
Herzschrittmacherther Elektrophysiol ; 30(2): 212-224, 2019 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-30767064

RESUMO

Premature ventricular contractions (PVC) are a common, often incidental and mostly benign finding. Treatment is indicated in frequent and symptomatic PVC or in cases of worsening of left ventricular function. Idiopathic ventricular tachycardia (VT) is mostly found in patients with a structurally healthy heart. These PVC/VT usually have a focal origin. The most likely mechanism is delayed post-depolarization. Localization of the origin is based on the creation of an activation map with or without combination of pace mapping. Idiopathic PVC/VT are most frequently located on the outflow tracts of the right and left ventricles, including the aortic root. Other typical locations include the annulus of the tricuspid or mitral valve, papillary muscles and Purkinje fibers. Catheter ablation is an alternative to antiarrhythmic medication in symptomatic monomorphic PVC/VT. The success rate is good whereby mapping and ablation can often represent a challenge. This article is the fifth part of a series dedicated to specific advanced training in the field of special rhythmology and invasive electrophysiology. It describes the pathophysiological principles, types and typical findings that can be obtained during an electrophysiological investigation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Eletrocardiografia , Ventrículos do Coração , Humanos
13.
J Interv Card Electrophysiol ; 22(1): 5-11, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18389353

RESUMO

BACKGROUND: Surgical ablation techniques using microwave energy are an alternative to catheter-based ablation therapy in the treatment of atrial fibrillation. We investigate electrical conduction properties of linear lesions after epicardial ablation in a pig model by using an electroanatomic mapping system. METHODS: After medial sternotomy in eight pigs epicardial pacing wires were placed on the anterior and posterolateral wall of the right atrium. Endocardial electroanatomical mapping was performed during pacing from anterior and posterolateral. Epicardial ablation was implemented in between the superior and inferior caval vein using microwave energy. Mapping was repeated to demonstrate conduction block or gap across the ablation line. When conduction gap was present the ablation procedure was repeated. Hearts were removed for histologic evaluation. RESULTS: Conduction block was observed in two pigs after the first ablation and in two additional pigs after the second ablation. Conduction gap was present in three pigs after the second ablation. One animal died during the second ablation. Histologic evaluation showed more severe transmural cellular damage in lesions with conduction gap. Complete lesions with conduction block more often showed moderate alterations. CONCLUSIONS: Epicardial microwave ablation can induce bidirectional conduction block, which is believed to be essential for therapeutic efficacy. However, the intraoperative macroscopic visible lesion and histological findings are not reliable markers of bidirectional conduction block. The Carto-Qwik-Map-System is an effective system to evaluate epicardial microwave lesions and to locate conduction gap areas intraoperatively. This increased the success rate regarding acute bidirectional conduction block after ablation in our experimental setting.


Assuntos
Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Micro-Ondas/uso terapêutico , Pericárdio/cirurgia , Animais , Fibrilação Atrial/patologia , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial , Feminino , Átrios do Coração , Miocárdio/patologia , Sus scrofa
14.
J Cardiovasc Med (Hagerstown) ; 19(4): 148-154, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29432401

RESUMO

PURPOSE: Despite various techniques used in atrial fibrillation ablation, recurrence of atrial arrhythmias still constitutes a clinical problem. The aim of this study was to document the long-term outcomes of pulmonary vein isolation with a ring-shaped ablation catheter (PVAC). METHODS: All consecutive patients presenting with paroxysmal or persistent atrial fibrillation (pxAF or perAF, respectively) treated with PVAC (first generation) were enrolled. After standard follow-up during the first year, all patients were contacted for long-term follow-up. In addition to the patient's medical history, 3-day Holter monitoring was performed. Endpoints were atrial fibrillation-related symptoms, ECG documentation of atrial fibrillation or other left atrial arrhythmias and reablation. RESULTS: In total, 125 patients (78% with pxAF) were enrolled. All but two pulmonary veins (0.4% of 485 pulmonary veins) could be successfully isolated. At 12 months, 83% of patients in the pxAF group and 53% of patients in the perAF group were free from symptoms. The mean long-term follow-up was 51 ±â€Š14 months. Regarding long-term efficacy, 56% of patients in the pxAF group and 28% of patients in the perAF group were free from any recurrence at 72 months. Independent predictors of event-free survival were perAF (hazard ratio 2.76, P = 0.001) and the existence of mild valvular disease (hazard ratio 2.69, P = 0.001). No significant complication due to PVAC occurred, especially no ischemic stroke. CONCLUSION: Long-term follow-up indicated for the first time in such a considerable cohort that pulmonary vein isolation with PVAC is a safe and very efficient method for treating pxAF - despite known microembolism issues. Patients with perAF receive less benefit from PVAC and ablation therapy should be reserved to pxAF. Significantly, even mild valvular disease was an independent predictor of atrial fibrillation recurrence.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Idoso , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Eletrocardiografia Ambulatorial , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo , Resultado do Tratamento
15.
JACC Clin Electrophysiol ; 4(6): 820-827, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29929676

RESUMO

OBJECTIVES: This study provides an update and comparison to a 2010 nationwide survey on cardiac electrophysiology (EP), types and numbers of interventional electrophysiological procedures, and training opportunities in 2015. BACKGROUND: In 2010, German cardiology centers performing interventional EP were identified and contacted to provide a survey on cardiac EP. METHODS: German cardiology centers performing interventional EP in 2015 were identified from quality reports and contacted to repeat the 2010 questionnaire. RESULTS: A majority of 131 centers (57%) responded. EP (ablation procedures and device therapy) was mainly part of a cardiology department (89%) and only independent (with its own budget) in 11%. The proportion of female physicians in EP training increased from 26% in 2010 to 38% in 2015. In total, 49,356 catheter ablations (i.e., 81% of reported ablations in 2015) were performed by the responding centers, resulting in a 44% increase compared with 2010 (the median number increased from 180 to 297 per center). Atrial fibrillation (AF) was the most common arrhythmia interventionally treated (47%). At 66% of the centers, (at least) 2 physicians were present during most catheter ablations. A minimum of 50 (75) AF ablations were performed at 80% (70%) of the centers. Pulmonary vein isolation with radiofrequency point-by-point ablation (62%) and cryoablation (33%) were the preferred ablation strategies. About one-third of centers reported surgical AF ablations, with 11 centers (8%) performing stand-alone surgical AF ablations. Only one-third of the responding 131 centers fulfilled all requirements for training center accreditation. CONCLUSIONS: Comparing 2010 with 2015, an increasing number of EP centers and procedures in Germany are registered. In 2015, almost every second ablation was for therapy for AF. Thus, an increasing demand for catheter ablation is likely, but training opportunities are still limited, and most centers do not fulfil recommended requirements for ablation centers.


Assuntos
Eletrofisiologia Cardíaca , Ablação por Cateter/estatística & dados numéricos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Adulto , Eletrofisiologia Cardíaca/educação , Eletrofisiologia Cardíaca/organização & administração , Eletrofisiologia Cardíaca/estatística & dados numéricos , Feminino , Alemanha/epidemiologia , Pessoal de Saúde/educação , Pessoal de Saúde/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade
16.
Front Neurol ; 8: 131, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28424659

RESUMO

INTRODUCTION: Left atrial pulmonary vein isolation (PVI) is an accepted treatment option for patients with symptomatic atrial fibrillation (AF). This procedure can be complicated by stroke or silent cerebral embolism. Online measurement of microembolic signals (MESs) by transcranial Doppler (TCD) may be useful for characterizing thromboembolic burden during PVI. In this prospective multicenter trial, we investigated the burden, characteristics, and composition of MES during left atrial catheter ablation using a variety of catheter technologies. MATERIALS AND METHODS: PVI was performed in a total of 42 patients using the circular-shaped multielectrode pulmonary vein ablation catheter (PVAC) technology in 23, an irrigated radiofrequency (IRF) in 14, and the cryoballoon (CB) technology in 5 patients. TCD was used to detect the total MES burden and sustained thromboembolic showers (TESs) of >30 s. During TES, the site of ablation within the left atrium was registered. MES composition was classified manually into "solid," "gaseous," or "equivocal" by off-line expert assessment. RESULTS: The total MES burden was higher when using IRF compared to CB (2,336 ± 1,654 vs. 593 ± 231; p = 0.007) and showed a tendency toward a higher burden when using IRF compared to PVAC (2,336 ± 1,654 vs. 1,685 ± 2,255; p = 0.08). TES occurred more often when using PVAC compared to IRF (1.5 ± 2 vs. 0.4 ± 1.3; p = 0.04) and most frequently when ablation was performed close to the left superior pulmonary vein (LSPV). Of the MES, 17.004 (23%) were characterized as definitely solid, 13.204 (18%) as clearly gaseous, and 44.366 (59%) as equivocal. DISCUSSION: We investigated the burden and characteristics of MES during left atrial catheter ablation for AF. All ablation techniques applied in this study generated a relevant number of MES. There was a significant difference in total MES burden using IRF compared to CB and a tendency toward a higher burden using IRF compared to PVAC. The highest TES burden was found in the PVAC group, particularly during ablation close to the LSPV. The composition of thromboembolic particles was balanced. The impact of MES, TES, and composition of thromboembolic particles on neurological outcome needs to be evaluated further. (Clinical Trial Registration: Deutsches Register Klinischer Studien, https://drks-neu.uniklinik-freiburg.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00003465. DRKS00003465.).

17.
Herzschrittmacherther Elektrophysiol ; 27(4): 381-389, 2016 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-27878364

RESUMO

The AV-reentrant tachycardia (AVRT) is a supraventricular tachycardia with an incidence of 1-3/1000. The pathophysiological basis is an accessory atrioventricular pathway (AP). Patients with AVRT typically present with palpitations, an on-off characteristic, anxiety, dyspnea, and polyuria. This type of tachycardia may often be terminated by vagal maneuvers. Although the clinical presentation of AVRT is quite similar to AV-nodal reentrant tachycardias, the correct diagnosis is often facilitated by analyzing a standard 12-lead ECG at normal heart rate showing ventricular preexcitation. Curative catheter ablation of the AP represents the therapy of choice in symptomatic patients. This article is the fourth part of a series written to improve the professional education of young electrophysiologists. It explains pathophysiology, symptoms, and electrophysiological findings of an invasive EP study. It focusses on mapping and ablation of accessory pathways.


Assuntos
Ablação por Cateter/métodos , Eletrocardiografia/métodos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/terapia , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/terapia , Mapeamento Potencial de Superfície Corporal/métodos , Diagnóstico Diferencial , Medicina Baseada em Evidências , Humanos , Exame Físico/métodos , Prognóstico , Avaliação de Sintomas/métodos , Resultado do Tratamento
18.
Heart Rhythm ; 2(6): 578-91, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15922263

RESUMO

BACKGROUND: Experience in catheter ablation of left atrial (LA) focal tachycardia and information about interatrial electrical connections during LA focal tachycardia are limited. OBJECTIVES: The purpose of this study was to describe our experience in electroanatomic mapping-guided catheter ablation of LA focal tachycardia and to investigate interatrial electrical connections during LA focal tachycardias. METHODS: Thirty-three patients undergoing catheter ablation for LA focal tachycardia guided by electroanatomic mapping were reported. Interatrial electrical connections were analyzed in LA focal tachycardias with biatrial electroanatomic maps. RESULTS: Of the 35 LA focal tachycardias (cycle length 309 +/- 100 ms) mapped, 19 (54%) originated from the pulmonary veins (PVs), 6 (17%) from the mitral annulus, 3 (8.6%) from LA roof, 3 (8.6%) from LA posterior wall, 2 (5.7%) from LA appendage, and 2 (5.7%) from LA septum. Fourteen of the 19 PV tachycardias (74%) were located in proximity to PV ostia. In 14 (7 PV, 7 non-PV) LA focal tachycardias with biatrial electroanatomic maps, posterior right atrium breakthrough sites at the intercaval area were identified in 7 PV tachycardias and 1 non-PV tachycardia. Five of the 7 PV tachycardias used only the posterior breakthrough for interatrial propagation. Procedural success was achieved in 33 of 35 LA focal tachycardias (94%) in 31 patients. During 23 +/- 19 months of follow-up, 2 patients (6%) had recurrence of ablated tachycardia, and 3 (10%) developed new LA focal tachycardias. CONCLUSIONS: The PVs and the mitral annulus were the main sources of LA focal tachycardias. The majority of PV tachycardias originated from PV ostia. A posterior interatrial connection appeared to play a major role in interatrial electrical propagation during PV tachycardias. Electroanatomic mapping facilitated precise localization of LA focal tachycardias and achievement of a high rate of ablation success.


Assuntos
Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiologia , Taquicardia Atrial Ectópica/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Atrial Ectópica/fisiopatologia , Resultado do Tratamento
19.
J Interv Card Electrophysiol ; 43(3): 217-26, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25921346

RESUMO

PURPOSE: Recently, diffusion-weighted magnetic resonance imaging (DW-MRI) revealed silent cerebral events (SCEs) as an acute complication of pulmonary vein isolation (PVI). We investigated whether SCEs following PVI are associated with neuropsychological deficits observed during patients' follow-up examinations. METHODS: After PVI, 52 patients were eligible for follow-up. PVI was performed using a variety of ablation technologies (duty-cycled phased radiofrequency (RF) multipolar ablation with the Pulmonary Vein Ablation Catheter® (PVAC) in 24 patients, cooled-tip RF ablation in 23 patients, and cryoballoon ablation in five patients). Fluid-attenuated inversion recovery (FLAIR)- and DW-MRI studies were performed 1 day before PVI and 1 day and 1 month afterward to detect pre-existing cerebral lesions or post-ablation SCEs. At the same times, eight neuropsychological tests were administered. We evaluated changes in patients' neuropsychological capabilities and compared changes in patients with SCEs to those without SCEs. RESULTS: FLAIR-MRI revealed pre-existing cerebral lesions in 42 patients (81 %), and DW-MRI demonstrated new SCEs in 25 patients (48 %) (17 treated with phased RF (PVAC) (71 %), six treated with irrigated RF (26 %), and two treated with cryoablation (40 %)). Neuropsychological test results showed no significant impairment (in median z scores) 1 day and 1 month after the ablation procedure. There was no difference in neuropsychological capabilities between patients with SCEs and those without SCEs except in one subtest (part of the verbal working memory test). CONCLUSIONS: The incidence of pre-existing cerebral lesions and post-ablation SCEs was high. The frequency of SCEs depends on the ablation technology used. Neither PVI nor post-ablation SCEs have any effect on neuropsychological capabilities.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Embolia Intracraniana/etiologia , Embolia Intracraniana/patologia , Transtornos Mentais/etiologia , Veias Pulmonares/cirurgia , Doenças Assintomáticas , Fibrilação Atrial/complicações , Feminino , Alemanha , Átrios do Coração/cirurgia , Sistema de Condução Cardíaco/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Transtornos Mentais/diagnóstico , Testes Neuropsicológicos , Resultado do Tratamento
20.
Herzschrittmacherther Elektrophysiol ; 26(4): 351-8, 2015 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-26558907

RESUMO

The AV nodal reentrant tachycardia (AVNRT) is one of the most common arrhythmias encountered in clinical practice. It is characterized by a constant heart rate and an on/off phenomenon. The clinical symptoms may include palpitations, anxiety, polyuria, and dyspnea. Typically, tachycardia may be disrupted by vagal maneuvers in many patients. First-line treatment of symptomatic AVNRT is radiofrequency ablation. The present article deals with the characteristics, differential diagnosis and treatment of AVNRT in the EP lab. It is the second part of a series of manuscripts which may facilitate further education in the specific field of electrophysiology.


Assuntos
Antiarrítmicos/administração & dosagem , Procedimentos Cirúrgicos Cardíacos/métodos , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/terapia , Mapeamento Potencial de Superfície Corporal/métodos , Terapia Combinada/métodos , Diagnóstico Diferencial , Medicina Baseada em Evidências , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa