1.
Alzheimers Dement ; 20(9): 6506-6516, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39030981

RESUMO

INTRODUCTION: We aimed to evaluate clinical interpretation cutpoints for two plasma phosphorylated tau (p-tau)217 assays (ALZpath and Lumipulse) as predictors of amyloid status for implementation in clinical practice. METHODS: Clinical performance of plasma p-tau217 against amyloid positron emission tomography status was evaluated in participants with mild cognitive impairment or mild dementia (n = 427). RESULTS: Using a one-cutpoint approach (negative/positive), neither assay achieved ≥ 90% in both sensitivity and specificity. A two-cutpoint approach yielding 92% sensitivity and 96% specificity provided the desired balance of false positives and false negatives, while categorizing 20% and 39% of results as indeterminate for the Lumipulse and ALZpath assays, respectively. DISCUSSION: This study provides a systematic framework for selection of assay-specific cutpoints for clinical use of plasma p-tau217 for determination of amyloid status. Our findings suggest that a two-cutpoint approach may have advantages in optimizing diagnostic accuracy while minimizing potential harm from false positive results. HIGHLIGHTS: Phosphorylated tau (p-tau)217 cutpoints for detection of amyloid pathology were established. A two-cutpoint approach exhibited the best performance for clinical laboratory use. p-tau217 assays differed in the percentage of results categorized as intermediate.


Assuntos
Encéfalo , Disfunção Cognitiva , Tomografia por Emissão de Pósitrons , Proteínas tau , Humanos , Proteínas tau/sangue , Feminino , Idoso , Masculino , Imunoensaio/métodos , Encéfalo/diagnóstico por imagem , Disfunção Cognitiva/sangue , Disfunção Cognitiva/diagnóstico , Fosforilação , Biomarcadores/sangue , Sensibilidade e Especificidade , Idoso de 80 Anos ou mais
2.
Int J Mol Sci ; 25(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38731812

RESUMO

We compared the clinical and analytical performance of Alzheimer's disease (AD) plasma biomarkers measured using the single-molecule array (Simoa) and Lumipulse platforms. We quantified the plasma levels of amyloid beta 42 (Aß42), Aß40, phosphorylated tau (Ptau181), and total tau biomarkers in 81 patients with mild cognitive impairment (MCI), 30 with AD, and 16 with non-AD dementia. We found a strong correlation between the Simoa and Lumipulse methods. Concerning the clinical diagnosis, Simoa Ptau181/Aß42 (AUC 0.739, 95% CI 0.592-0.887) and Lumipulse Aß42 and Ptau181/Aß42 (AUC 0.735, 95% CI 0.589-0.882 and AUC 0.733, 95% CI 0.567-0.900) had the highest discriminating power. However, their power was significantly lower than that of CSF Aß42/Aß40, as measured by Lumipulse (AUC 0.879, 95% CI 0.766-0.992). Simoa Ptau181 and Lumipulse Ptau181/Aß42 were the markers most consistent with the CSF Aß42/Aß40 status (AUC 0.801, 95% CI 0.712-0.890 vs. AUC 0.870, 95% CI 0.806-0.934, respectively) at the ≥2.127 and ≥0.084 cut-offs, respectively. The performance of the Simoa and Lumipulse plasma AD assays is weaker than that of CSF AD biomarkers. At present, the analysed AD plasma biomarkers may be useful for screening to reduce the number of lumbar punctures in the clinical setting.


Assuntos
Doença de Alzheimer , Peptídeos beta-Amiloides , Biomarcadores , Disfunção Cognitiva , Proteínas tau , Humanos , Doença de Alzheimer/líquido cefalorraquidiano , Doença de Alzheimer/sangue , Doença de Alzheimer/diagnóstico , Biomarcadores/sangue , Biomarcadores/líquido cefalorraquidiano , Masculino , Feminino , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Peptídeos beta-Amiloides/sangue , Idoso , Proteínas tau/líquido cefalorraquidiano , Proteínas tau/sangue , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/líquido cefalorraquidiano , Disfunção Cognitiva/sangue , Pessoa de Meia-Idade , Fragmentos de Peptídeos/líquido cefalorraquidiano , Fragmentos de Peptídeos/sangue , Idoso de 80 Anos ou mais , Fosforilação
3.
Clin Chem Lab Med ; 61(2): 323-331, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36282616

RESUMO

OBJECTIVES: The rapid, accurate and safe detection of SARS-CoV-2 is the key to improving surveillance and infection containment. The aim of the present study was to ascertain whether, after heat/chemical inactivation, SARS-CoV-2 N antigen chemiluminescence (CLEIA) assay in saliva remains a valid alternative to molecular testing. METHODS: In 2022, 139 COVID-19 inpatients and 467 healthcare workers were enrolled. In 606 self-collected saliva samples (Salivette), SARS-CoV-2 was detected by molecular (TaqPath rRT-PCR) and chemiluminescent Ag assays (Lumipulse G). The effect of sample pre-treatment (extraction solution-ES or heating) on antigen recovery was verified. RESULTS: Salivary SARS-CoV-2 antigen assay was highly accurate (AUC=0.959, 95% CI: 0.943-0.974), with 90% sensitivity and 92% specificity. Of the 254 antigen positive samples, 29 were false positives. We demonstrated that heterophilic antibodies could be a cause of false positive results. A significant antigen concentration decrease was observed after ES treatment (p=0.0026), with misclassification of 43 samples. Heat had a minimal impact, after treatment the correct classification of cases was maintained. CONCLUSIONS: CLEIA SARS-CoV-2 salivary antigen provides accurate, timely and high-throughput results that remain accurate also after heat inactivation, thus ensuring a safer work environment. This supports the use of salivary antigen detection by CLEIA in surveillance programs.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , Saliva , Sensibilidade e Especificidade
4.
J Infect Chemother ; 29(1): 15-19, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36089257

RESUMO

INTRODUCTION: Anterior nasal sampling (AN) might be more convenient for patients than NP sampling to diagnose coronavirus disease. This study investigated the feasibility of rapid antigen tests for AN sampling, and the factors affecting the test accuracy. METHODS: This single-center prospective study evaluated one qualitative (ESP) and two quantitative (LUMI and LUMI-P) rapid antigen tests using AN and NP swabs. Symptomatic patients aged 20 years or older, who were considered eligible for reverse-transcription quantitative polymerase chain reaction using NP samples within 9 days of onset were recruited. Sensitivity, specificity, and positive and negative concordance rates between AN and NP samples were assessed for the rapid antigen tests. We investigated the characteristics that affected the concordance between AN and NP sampling results. RESULTS: A total of 128 cases were recruited, including 28 positive samples and 96 negative samples. The sensitivity and specificity of AN samples using ESP were 0.81 and 1.00, while those of NP samples were 0.94 and 1.00. The sensitivity of AN and NP samples was 0.91 and 0.97, respectively, and specificity was 1.00, for both LUMI and LUMI-P. The positive concordance rates of AN to NP sampling were 0.87, 0.94, and 0.85 for ESP, LUMI, and LUMI-P, respectively. No factor had a significant effect on the concordance between the sampling methods. CONCLUSIONS: ESP, LUMI, and LUMI-P showed practical diagnostic accuracy for AN sampling compared to NP sampling. There was no significant factor affecting the concordance between AN and NP sampling for these rapid antigen tests.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Estudos Prospectivos , COVID-19/diagnóstico , Teste para COVID-19 , Sensibilidade e Especificidade , Nasofaringe
5.
BMC Infect Dis ; 22(1): 221, 2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35246055

RESUMO

BACKGROUND: The nucleic acid amplification test (NAAT) and antigen test are approved diagnostic tests for COVID-19. In this study, we aimed to investigate the assay performance of two NAATs (Xpert Xpress SARS-CoV-2 and FilmArray Respiratory Panel) and a quantitative antigen test (Lumipulse). METHODS: One hundred and sixty-five nasopharyngeal swabs were subjected to Xpert, FilmArray, Lumipulse, and RT-qPCR assays. RESULTS: Of 165 samples, RT-qPCR showed 100 positives and 65 negatives. The Xpert had an overall agreement of 99.4% (95% confidence interval [CI]: 96.7-99.4%), sensitivity of 99% (95% CI: 96.8-99%), and specificity of 100% (95% CI: 96.6-100%). FilmArray had an overall agreement of 98.8% (95% CI: 95.9-98.8%), sensitivity of 98% (95% CI: 95.6-98%), and specificity of 100% (95% CI: 96.3-100%). Lumipulse had an overall agreement of 95.5% (95% CI: 91.8-95.5%), sensitivity of 92.3% (95% CI: 89.2-92.3%), and specificity of 100% (95% CI: 95.5-100%). The κ coefficient showed excellent agreement between each test and RT-qPCR. There was a high correlation between Xpert Ct values, RT-qPCR Ct values, viral loads and antigen level. CONCLUSIONS: Xpert Xpress and FilmArray Respiratory Panel exhibited an equivalent performance. The Lumipulse antigen test was slightly less sensitive than the NAATs, but showed high assay performance except for samples with low viral load. The Xpert Xpress, FilmArray Respiratory Panel and Lumipulse antigen tests offer rapid sample-to-answer data, allowing random access detection on automated devices.


Assuntos
COVID-19 , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , Nasofaringe , SARS-CoV-2 , Sensibilidade e Especificidade
6.
Clin Chem Lab Med ; 60(2): 207-219, 2022 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-34773730

RESUMO

OBJECTIVES: The core cerebrospinal fluid (CSF) biomarkers; total tau (tTau), phospho-tau (pTau), amyloid ß 1-42 (Aß 1-42), and the Aß 1-42/Aß 1-40 ratio have transformed Alzheimer's disease (AD) research and are today increasingly used in clinical routine laboratories as diagnostic tools. Fully automated immunoassay instruments with ready-to-use assay kits and calibrators has simplified their analysis and improved reproducibility of measurements. We evaluated the analytical performance of the fully automated immunoassay instrument LUMIPULSE G (Fujirebio) for measurement of the four core AD CSF biomarkers and determined cutpoints for AD diagnosis. METHODS: Comparison of the LUMIPULSE G assays was performed with the established INNOTEST ELISAs (Fujirebio) for hTau Ag, pTau 181, ß-amyloid 1-42, and with V-PLEX Plus Aß Peptide Panel 1 (6E10) (Meso Scale Discovery) for Aß 1-42/Aß 1-40, as well as with a LC-MS reference method for Aß 1-42. Intra- and inter-laboratory reproducibility was evaluated for all assays. Clinical cutpoints for Aß 1-42, tTau, and pTau was determined by analysis of three cohorts of clinically diagnosed patients, comprising 651 CSF samples. For the Aß 1-42/Aß 1-40 ratio, the cutpoint was determined by mixture model analysis of 2,782 CSF samples. RESULTS: The LUMIPULSE G assays showed strong correlation to all other immunoassays (r>0.93 for all assays). The repeatability (intra-laboratory) CVs ranged between 2.0 and 5.6%, with the highest variation observed for ß-amyloid 1-40. The reproducibility (inter-laboratory) CVs ranged between 2.1 and 6.5%, with the highest variation observed for ß-amyloid 1-42. The clinical cutpoints for AD were determined to be 409 ng/L for total tau, 50.2 ng/L for pTau 181, 526 ng/L for ß-amyloid 1-42, and 0.072 for the Aß 1-42/Aß 1-40 ratio. CONCLUSIONS: Our results suggest that the LUMIPULSE G assays for the CSF AD biomarkers are fit for purpose in clinical laboratory practice. Further, they corroborate earlier presented reference limits for the biomarkers.


Assuntos
Doença de Alzheimer , Doença de Alzheimer/líquido cefalorraquidiano , Doença de Alzheimer/diagnóstico , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Biomarcadores/líquido cefalorraquidiano , Humanos , Imunoensaio/métodos , Fragmentos de Peptídeos/líquido cefalorraquidiano , Reprodutibilidade dos Testes , Proteínas tau/líquido cefalorraquidiano
7.
Int J Mol Sci ; 23(13)2022 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-35805894

RESUMO

BACKGROUND: Clinical diagnosis of Alzheimer's disease (AD) increasingly incorporates CSF biomarkers. However, due to the intrinsic variability of the immunodetection techniques used to measure these biomarkers, establishing in-house cutoffs defining the positivity/negativity of CSF biomarkers is recommended. However, the cutoffs currently published are usually reported by using cross-sectional datasets, not providing evidence about its intrinsic prognostic value when applied to real-world memory clinic cases. METHODS: We quantified CSF Aß1-42, Aß1-40, t-Tau, and p181Tau with standard INNOTEST® ELISA and Lumipulse G® chemiluminescence enzyme immunoassay (CLEIA) performed on the automated Lumipulse G600II. Determination of cutoffs included patients clinically diagnosed with probable Alzheimer's disease (AD, n = 37) and subjective cognitive decline subjects (SCD, n = 45), cognitively stable for 3 years and with no evidence of brain amyloidosis in 18F-Florbetaben-labeled positron emission tomography (FBB-PET). To compare both methods, a subset of samples for Aß1-42 (n = 519), t-Tau (n = 399), p181Tau (n = 77), and Aß1-40 (n = 44) was analyzed. Kappa agreement of single biomarkers and Aß1-42/Aß1-40 was evaluated in an independent group of mild cognitive impairment (MCI) and dementia patients (n = 68). Next, established cutoffs were applied to a large real-world cohort of MCI subjects with follow-up data available (n = 647). RESULTS: Cutoff values of Aß1-42 and t-Tau were higher for CLEIA than for ELISA and similar for p181Tau. Spearman coefficients ranged between 0.81 for Aß1-40 and 0.96 for p181TAU. Passing-Bablok analysis showed a systematic and proportional difference for all biomarkers but only systematic for Aß1-40. Bland-Altman analysis showed an average difference between methods in favor of CLEIA. Kappa agreement for single biomarkers was good but lower for the Aß1-42/Aß1-40 ratio. Using the calculated cutoffs, we were able to stratify MCI subjects into four AT(N) categories. Kaplan-Meier analyses of AT(N) categories demonstrated gradual and differential dementia conversion rates (p = 9.815-27). Multivariate Cox proportional hazard models corroborated these findings, demonstrating that the proposed AT(N) classifier has prognostic value. AT(N) categories are only modestly influenced by other known factors associated with disease progression. CONCLUSIONS: We established CLEIA and ELISA internal cutoffs to discriminate AD patients from amyloid-negative SCD individuals. The results obtained by both methods are not interchangeable but show good agreement. CLEIA is a good and faster alternative to manual ELISA for providing AT(N) classification of our patients. AT(N) categories have an impact on disease progression. AT(N) classifiers increase the certainty of the MCI prognosis, which can be instrumental in managing real-world MCI subjects.


Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/psicologia , Peptídeos beta-Amiloides , Biomarcadores , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/psicologia , Estudos Transversais , Progressão da Doença , Humanos , Fragmentos de Peptídeos , Proteínas tau
8.
Clin Chem Lab Med ; 59(8): 1468-1476, 2021 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-33823089

RESUMO

OBJECTIVES: Compared to RT-PCR, lower performance of antigen detection assays, including the Lumipulse G SARS-CoV-2 Ag assay, may depend on specific testing scenarios. METHODS: We tested 594 nasopharyngeal swab samples from individuals with COVID-19 (RT-PCR cycle threshold [Ct] values ≤ 40) or non-COVID-19 (Ct values >40) diagnoses. RT-PCR positive samples were assigned to diagnostic, screening, or monitoring groups of testing. RESULTS: With a limit of detection of 1.2 × 104 SARS-CoV-2 RNA copies/mL, Lumipulse showed positive percent agreement (PPA) of 79.9% (155/194) and negative percent agreement of 99.3% (397/400), whereas PPAs were 100% for samples with Ct values of <18 or 18-<25 and 92.5% for samples with Ct values of 25-<30. By three groups, Lumipulse showed PPA of 87.0% (60/69), 81.1% (43/53), or 72.2% (52/72), respectively, whereas PPA was 100% for samples with Ct values of <18 or 18-<25, and was 94.4, 80.0, or 100% for samples with Ct values of 25-<30, respectively. Additional testing of RT-PCR positive samples for SARS-CoV-2 subgenomic RNA showed that, by three groups, PPA was 63.8% (44/69), 62.3% (33/53), or 33.3% (24/72), respectively. PPAs dropped to 55.6, 20.0, or 41.7% for samples with Ct values of 25-<30, respectively. All 101 samples with a subgenomic RNA positive result had a Lumipulse assay's antigen positive result, whereas only 54 (58.1%) of remaining 93 samples had a Lumipulse assay's antigen positive result. CONCLUSIONS: Lumipulse assay was highly sensitive in samples with low RT-PCR Ct values, implying repeated testing to reduce consequences of false-negative results.


Assuntos
COVID-19/diagnóstico , RNA Viral/análise , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2/genética , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19 , Humanos , Limite de Detecção , Nasofaringe/virologia , Kit de Reagentes para Diagnóstico , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
9.
J Infect Chemother ; 27(6): 800-807, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33546959

RESUMO

INTRODUCTION: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is rapidly spreading all over the world. A new quantifying reagent for detecting SARS-CoV-2 antigen was developed for early and accurate detection. We evaluated the novel quantitative reagent for detecting SARS-CoV-2 antigen using an automated laboratory device. METHODS: One-hundred nasopharyngeal samples were collected from 47 SARS-CoV-2-infected patients, and 200 samples were collected from healthy donners. We measured the SARS-CoV-2 antigen and nucleic acid using Lumipulse Presto SARS-CoV-2 Ag and the 2019 Novel Coronavirus Detection Kit, respectively. RESULTS: The sensitivity and specificity of the SARS-CoV-2 antigen test were 75.7% (56/74) and 96.0% (192/200), respectively. The concordance rate in the positive group between the antigen and nucleic acid tests was 66% (66/100). In addition, the correlation coefficient between the concentration of SARS-CoV-2 antigen and the level of SARS-CoV-2 RNA was 0.74. There were 19 discrepant samples in which SARS-CoV-2 RNA was detected without SARS-CoV-2 antigen. There was significant difference between the discrepant and matched samples in terms of the time since symptom onset: the 19 discrepant samples were collected a median of 33 days after onset, while the 55 matched samples were collected a median of 19 days after onset. In addition, the 19 discrepant samples were collected from patients who were immune against SARS-CoV-2. CONCLUSIONS: This novel SARS-CoV-2 antigen detection assay is highly sensitive, rapid, accurate, easily diagnostic. It may be useful in both clinical diagnosis and in screening because it does not require special methods such as PCR.


Assuntos
Antígenos Virais/análise , Teste para COVID-19/instrumentação , COVID-19/diagnóstico , Indicadores e Reagentes , Automação Laboratorial , Humanos , RNA Viral , SARS-CoV-2 , Sensibilidade e Especificidade
10.
J Infect Chemother ; 27(6): 915-918, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33676843

RESUMO

INTRODUCTION: The rapid and accurate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is required to prevent the spread of COVID-19. This study evaluated the utility of two SARS-CoV-2 antigen detection methods. METHODS: We evaluated two types of antigen detection methods using immunochromatography (Espline) and quantitative chemiluminescent enzyme immunoassay (Lumipulse). RT-PCR was performed as a standard procedure for COVID-19 diagnosis. Lumipulse and RT-PCR were performed for all 486 nasopharyngeal swabs and 136 saliva samples, and the Espline test was performed for 271 nasopharyngeal swabs and 93 saliva samples. RESULTS: The sensitivity and specificity of the Espline test were 10/11 and 260/260 (100%), respectively for the nasopharyngeal swabs and 3/9 and 84/84 (100%), respectively for the saliva samples. High sensitivities for both saliva (8/9) and nasopharyngeal swabs (22/24) were observed in the Lumipulse test. The specificities of the Lumipulse test for nasopharyngeal swabs and saliva samples were 460/462 (99.6%) and 123/127 (96.9%), respectively. CONCLUSION: The Espline test is not effective for saliva samples but is useful for simple and rapid COVID-19 tests using nasopharyngeal swabs because it does not require special devices. The Lumipulse test is a powerful high-throughput tool for COVID-19 diagnosis because it has high detection performance for nasopharyngeal swabs and saliva samples.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Cromatografia de Afinidade , Técnicas Imunoenzimáticas , Medições Luminescentes , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antígenos Virais/isolamento & purificação , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nasofaringe/virologia , Saliva/virologia , Adulto Jovem
11.
J Infect Chemother ; 27(11): 1669-1673, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34454833

RESUMO

INTRODUCTION: The automated quantitative antigen test (QAT), which detects severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is suitable for mass screening. However, its diagnostic capability differentiated by time from onset and potential contribution to infectivity assessment have not been fully investigated. METHODS: A retrospective, observational study using nasopharyngeal swab specimens from coronavirus disease (COVID-19) inpatients was conducted using LumipulseⓇ SARS-CoV-2 antigen test. Diagnostic accuracy was examined for the early (up to 10 days after onset) and late (over 10 days after onset) stages. Time-course QAT changes and reverse-transcription quantitative polymerase chain reaction tests results were displayed as locally estimated scatterplot smoothing curve, and receiver operating characteristic curve (ROC) analysis was used to determine the appropriate cutoff value for differentiating the early and late stages. RESULTS: We obtained 100 specimens from 68 COVID-19 patients, including 51 early-stage and 49 late-stage specimens. QAT sensitivity and specificity were 0.82 (0.72-0.90) and 0.95 (0.75-0.99) for all periods, 0.93 (0.82-0.98) and 1.00 (0.39-1.00) for the early stage, and 0.66 (0.48-0.82) and 0.93 (0.69-0.99) for the late stage, respectively. The ROC analysis indicated an ideal cutoff value of 6.93 pg/mL for distinguishing early-from late-stage specimens. The sensitivity, specificity, positive predictive value, and negative predictive value for predicting the late stage were 0.76 (0.61-0.87), 0.76 (0.63-0.87), 0.76 (0.61-0.87), and 0.76 (0.63-0.87). CONCLUSIONS: QAT has favorable diagnostic accuracy in the early COVID-19 stages. In addition, an appropriate cutoff point can potentially facilitate rapid identification of noncontagious patients.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Testes Imunológicos , Nasofaringe , Estudos Retrospectivos , Sensibilidade e Especificidade
12.
J Clin Lab Anal ; 34(2): e23070, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31691368

RESUMO

BACKGROUND: The sputum saccharide chain antigen (Krebs von den Lungen-6 [KL-6]) is a serum biomarker of lung injury. We aimed to evaluate the clinical performance of the automated immunoassay analyzer HISCL-5000 in detecting KL-6 by comparing it with LUMIPULSE G1200 and determine the diagnostic value of KL-6 in interstitial lung disease (ILD). METHODS: A total of 145 serum samples from patients were tested using the two automated immunoassay analyzers in parallel. RESULTS: With a cutoff level of 500 U/mL, comparing the two systems, the agreement, sensitivity, specificity, and kappa value were 99.20%, 100%, 98.63%, and 0.984 (95% CI, 0.952-1.000), respectively. Spearman's correlation and ICC showed that there was a strong correlation between serum KL-6 levels measured by the two systems (rS  = .991 [95% CI, 0.981-0.995], ICC = 0.984 [95% CI, 0.978-0.989], P < .01). The clinical diagnosis agreement rate in both systems was >80%. The kappa value was 0.707 (95% CI, 0.582-0.832; SYSTEM B) and 0.707 (95% CI, 0.588-0.826; SYSTEM A). The KL-6 level in the ILD group (1339.5, 662.5-2363) was significantly higher than that in the non-ILD groups (252, 158.5-353; Mann-Whitney U = 381.5, P < .01), and the KL-6 level (1558, 726-2772.5) in the ILD group detected by SYSTEM A was significantly higher than that in the lung cancer group (339, 207-424), other respiratory disease group (249, 194-366), and control group (198, 131.5-297; Kruskal-Wallis H = 63.19, P < .01). CONCLUSIONS: HISCL-5000 showed well-concordant results with those of HISCL-5000 in the KL-6 tests. In patients with ILD, KL-6 showed a good diagnostic performance.


Assuntos
Imunoensaio/instrumentação , Doenças Pulmonares Intersticiais/diagnóstico , Mucina-1/sangue , Adulto , Idoso , Feminino , Humanos , Doenças Pulmonares Intersticiais/sangue , Neoplasias Pulmonares/sangue , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos
13.
Alzheimers Dement ; 16(1): 144-152, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31914216

RESUMO

INTRODUCTION: Cerebrospinal fluid (CSF) biomarkers can identify individuals with Alzheimer's disease (AD) pathology (eg, amyloid plaques, neurofibrillary tangles), but defined analyte cut-points using high-throughput automated assays are necessary for general clinical use. METHODS: CSF amyloid ß42 peptide (Aß42), t-tau, and t-tau/Aß42 were quantified by the Lumipulse platform in two test cohorts (A/B: Eisai BAN2401-201/MISSION AD E2609-301/302, n = 138; C: Knight Alzheimer's Disease Research Center (ADRC), n = 198), and receiver operating characteristic (ROC) curve analyses defined cut-points corresponding best to amyloid determinations using positron emission tomography (PET) imaging. The best-performing cut-point was then validated as a predictor of amyloid status in an independent cohort (D: MISSION AD E2609-301/302, n = 240). RESULTS: Virtually identical t-tau/Aß42 cut-points (∼0.54) performed best in both test cohorts and with similar accuracy (areas under ROC curve [AUCs] [A/B: 0.95; C: 0.94]). The cut-point yielded an overall percent agreement with amyloid PET of 85.0% in validation cohort D. DISCUSSION: Lumipulse CSF biomarker measures with validated cut-points have clinical utility in identifying AD pathology.


Assuntos
Doença de Alzheimer/líquido cefalorraquidiano , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Amiloide/metabolismo , Biomarcadores/líquido cefalorraquidiano , Fragmentos de Peptídeos/líquido cefalorraquidiano , Proteínas tau/líquido cefalorraquidiano , Idoso , Peptídeos beta-Amiloides/metabolismo , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/metabolismo , Tomografia por Emissão de Pósitrons , Reprodutibilidade dos Testes
14.
J Clin Lab Anal ; 33(6): e22921, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31131509

RESUMO

BACKGROUND: Protein induced by vitamin K antagonist-II (PIVKA-II), in addition to alpha-fetoprotein, is a useful tumor marker for diagnosis of hepatocellular carcinoma (HCC). We evaluated the analytical performance of the HISCL-5000 analyzer (Sysmex Corporation) in the measurement of serum PIVKA-II. METHODS: We evaluated the precision and linearity of PIVKA-II assays using the HISCL-5000 analyzer. Methods using HISCL-5000, LUMIPULSE G1200 (Fujirebio Diagnostics), and ARCHITECT i2000 (Abbott Diagnostics) were compared according to the guidelines of the Clinical and Laboratory Standards Institute. A total of 501 subjects (median age 59 years, age range 24-90 years) were enrolled. Among them, 335 were HCC patients, 46 were patients with non-HCC liver disease, and 120 were healthy individuals. Non-HCC liver disease included liver cirrhosis, chronic hepatitis, HBV or HCV carrier, hepatic adenoma, and intrahepatic cholangiocarcinoma. RESULTS: Repeatability (%CV) in low- and high-level controls and pooled serum was 2.81%-10.30%, and within-laboratory precision was 4.24%-8.86%. In a linearity test, the coefficient of determination (R2 ) was 0.9957, ranging from 11 to 69 897 mAU/mL. In comparison, the coefficient of correlation (r) was 0.9561-0.9644, agreement was 93.4%-97.6%, and the κ value was 0.855-0.945 among the three analyzers. About 99.2% of healthy individuals and 84.8% of non-HCC liver disease patients were below the cutoff value (40 mAU/mL) on HISCL-5000. CONCLUSIONS: A PIVKA-II assay using HISCL-5000 showed acceptable analytical performance including precision, linearity, and method comparison. This indicates that HISCL-5000 can be potentially helpful in clinical laboratories.


Assuntos
Biomarcadores/sangue , Análise Química do Sangue/instrumentação , Precursores de Proteínas/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise Química do Sangue/métodos , Ensaio de Imunoadsorção Enzimática/instrumentação , Feminino , Humanos , Hepatopatias/sangue , Masculino , Pessoa de Meia-Idade , Protrombina , Reprodutibilidade dos Testes , Adulto Jovem
15.
J Clin Lab Anal ; 32(4): e22334, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28984383

RESUMO

BACKGROUND: Ongoing efforts in the development of HBsAg detection kits are focused on improving sensitivity and specificity. The purpose of this study was to evaluate an improved, highly sensitive quantitative assay, "Lumipulse HBsAg-HQ", a chemiluminescent enzyme immunoassay designed for a fully automated instrument, the "Lumipulse G1200". METHODS: Serum samples for reproducibility, dilution, correlation, sensitivity, and specificity studies were obtained from patients at the Osaka University Hospital. Seroconversion and sensitivity panels were purchased from a commercial vender. Subtype, sensitivity panels, and HBsAg recombinant proteins with one or two amino acid substitutions were prepared in-house. RESULTS: The coefficients of variation for the low, medium, and high concentration samples ranged from 1.93 to 2.55%. The HBsAg-HQ reagent for dilution testing showed good linearity in the 0.005-150 HBsAg IU/mL range and no prozone phenomenon. All 102 HBV carrier samples were positive by HBsAg-HQ, while other commercial reagents showed one or more to be negative. In the seroconversion panel, the 14-day blood sample was positive. The sensitivity against HBsAg-HQ "ad" and "ay" subtypes was 0.025 ng/mL. Comparisons among the HBsAg-HQ, HISCL, and Architect HBsAg reagents were performed using the Bland-Altman plot. Specificity for 1000 seronegative individuals was 99.7%. HBsAg-HQ detected 29 positive serum among 12 231 routinely obtained serum samples, which showed concentrations of 0.005-0.05 HBsAg IU/mL. CONCLUSIONS: According to these results, the Lumipulse HBsAg-HQ assay, with a highly sensitive limit of detection of 0.005 IU/mL, may facilitate the development of a better management strategy for a considerable proportion of infected patients.


Assuntos
Antígenos de Superfície da Hepatite B/sangue , Vírus da Hepatite B , Hepatite B/diagnóstico , Técnicas Imunoenzimáticas/métodos , Humanos , Limite de Detecção , Modelos Lineares , Medições Luminescentes/métodos , Reprodutibilidade dos Testes
16.
J Clin Microbiol ; 55(11): 3236-3241, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28878003

RESUMO

A syphilis diagnosis is often aided by the detection of treponemal and nontreponemal antibodies. Automated treponemal antibody detection systems enable high-volume clinical laboratories to perform syphilis screening at a faster pace with lower labor costs. The Lumipulse G TP-N chemiluminescent immunoassay is an automated system that qualitatively detects IgG and IgM antibodies against Treponema pallidum antigens in human serum and plasma. To assess performance characteristics and workflow efficiency, the Lumipulse G TP-N assay was compared to the Bioplex 2200 Syphilis IgG multiplex flow immunoassay. Among the 4,134 routine and HIV samples tested by the two automated assays, the percentage of agreement was excellent at 99.0% (95% confidence interval [CI], 98.6% to 99.2%; κ, 0.89), with the Lumipulse G TP-N having a shorter time to first and subsequent results. All specimens with reactive syphilis screening results were further tested by rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TP·PA) testing (n = 231). The results from the RPR-reactive samples (n = 82) showed complete concordance with the two automated assays, while the TP·PA assay displayed some discrepancies. The positive percent agreement (PPA) and negative percent agreement (NPA) between the TP·PA test and the Lumipulse G TP-N test were 98.9% and 77.3%, respectively. The Bioplex 2200 Syphilis IgG immunoassay displayed a similar PPA (100%) but a substantially lower NPA (15.9%). Patient chart reviews of discrepant results suggested that the Lumipulse G TP-N assay produced 27 fewer falsely reactive results and can reduce the amount of additional confirmatory RPR and TP·PA testing needed. The analogous performance characteristics of the two automated systems indicate that the Lumipulse G TP-N assay is suitable for high-throughput syphilis screening.


Assuntos
Anticorpos Antibacterianos/sangue , Testes Diagnósticos de Rotina/métodos , Imunoensaio/métodos , Medições Luminescentes/métodos , Programas de Rastreamento/métodos , Sífilis/diagnóstico , Treponema pallidum/imunologia , Automação Laboratorial/métodos , Erros de Diagnóstico , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Fatores de Tempo
17.
J Viral Hepat ; 24(1): 80-85, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27699936

RESUMO

The increasing incidence of hepatocellular carcinoma (HCC) in Western countries requests reliable tumour markers for preclinical diagnosis. We evaluated the diagnostic accuracy of des-gamma-carboxy prothrombin (DCP), in comparison with alpha-fetoprotein (AFP) in a French cohort using a new analyser. One hundred and sixty-two patients with virus-related cirrhosis (46 HCC patients and 116 controls) were recruited in this retrospective proof-of-concept study. DCP was measured on new Lumipulse® G600 analyzer and AFP on usual Cobas e602 analyzer in serum samples that were collected at the time of HCC diagnosis for HCC patients or during follow-up for controls. DCP and AFP levels were higher in HCC patients. The area under receiver operating characteristic curve was larger for DCP than for AFP (0.89 vs 0.77, P=.03). At the cut-off value of 128 mAU/mL, sensitivity and specificity for DCP were 74% and 92%. At the cut-off value of 20 µg/L, sensitivity and specificity for AFP were 63% and 82%. NRI>0 for the association of "AFP+DCP" were 101%, P<.0001, and 23%, P=.03, compared to "AFP" or "DCP" alone, respectively. We conclude that DCP outperformed AFP for the detection of HCC.


Assuntos
Biomarcadores/sangue , Carcinoma Hepatocelular/diagnóstico , Neoplasias Hepáticas/diagnóstico , Precursores de Proteínas/sangue , Idoso , Carcinoma Hepatocelular/sangue , Feminino , França , Humanos , Neoplasias Hepáticas/sangue , Masculino , Pessoa de Meia-Idade , Protrombina , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Soro/química , alfa-Fetoproteínas/análise
19.
J Neurol Sci ; 463: 123115, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38964268

RESUMO

OBJECTIVE: Blood neurofilament light chain (NfL) is robustly associated with disease worsening in multiple sclerosis (MS), though potentially affected by concomitant factors also determining neuro-axonal loss. We investigated the association between plasma NfL (pNfL) measured with Lumipulse™ immunoassay and demographic and clinical variables in MS. METHODS: This cross-sectional study included 685 people with MS (age 49.7 ± 12.4 years; sex 65.55% females). On the same day, we collected plasma samples, along with demographics, comorbidities, and clinical variables (MS disease duration, expanded disability status scale (EDSS), Symbol Digit Modalities Test (SDMT), descriptor of disease progression, current disease modifying treatment (DMT), number of previous DMTs, evidence of disease activity in the past year (i.e. relapse or MRI new lesions), EDSS progression). pNfL was evaluated using Lumipulse™ fully automated chemiluminescent enzyme immunoassay. RESULTS: On multivariable linear regression model, higher pNfL was associated with higher EDSS (Coeff = 1.73; 95%CI 0.78, 2.68; p < 0.01), recent disease activity (Coeff = 15.70; 95%CI = 5.35, 26.06; p < 0.01), and presence of cardiovascular comorbidity (Coeff = 3.84; 95%CI 0.48, 7.20; p = 0.025). Lower pNfL was found in patients on DMT treatment (Coeff = -10.23; 95%CI -18.42, -2.04; p = 0.015), when compared with no DMT (reference). For 77.81% of our population there was correspondence between pNfL levels and two previously-validated cutoffs. CONCLUSIONS: pNfL measured using Lumipulse™ confirms known associations with MS activity, disability and treatments, and related confounding (e.g., cardiovascular comorbidity), thus granting further utilization in research and clinical practice.


Assuntos
Esclerose Múltipla , Proteínas de Neurofilamentos , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Proteínas de Neurofilamentos/sangue , Estudos Transversais , Esclerose Múltipla/sangue , Esclerose Múltipla/diagnóstico , Imunoensaio/métodos , Adulto , Biomarcadores/sangue , Progressão da Doença , Avaliação da Deficiência
20.
Neurobiol Aging ; 143: 30-40, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39208716

RESUMO

Aim of the project was to evaluate the technical and clinical validity of plasma Lumipulse p-tau, Aß42 and Aß40 species and their correlation with CSF core Alzheimer's Disease (AD) markers; a method comparison with SIMOA was also performed. One-hundred-thirthy-three participants, namely 55 A+T+N+ AD, 28 Neurodegenerative disorders (NDD) and 50 controls were enrolled for the study. Lumipulse technical validity showed high stability for p-tau181, Aß42, and Aß40, with higher stability of p-tau to repeated freezing thaw cycles. p-tau181 levels detected by both techniques were higher in AD compared to both NDD/controls and exhibited a similar correlation with CSF p-tau levels, whereas Aß42 levels were slightly lower in AD with both methods. In the comparison between SIMOA and Lumipulse plasma markers, both techniques exhibited similar diagnostic accuracy for AD for p-tau181 (0.87; 95 %CI 0.81-0.94, vs 0.85; 95 %CI 0.78-0.93), whereas the best performance was reached by p-tau181/ Aß42 Lumipulse ratio (ROC AUC 0.915, 95 %CI 0.86-0.97). The study thus confirmed the construct validity of both Lumipulse and SIMOA techniques for the identification of CSF AD pattern in clinical settings.


Assuntos
Doença de Alzheimer , Peptídeos beta-Amiloides , Biomarcadores , Proteínas tau , Doença de Alzheimer/sangue , Doença de Alzheimer/diagnóstico , Humanos , Proteínas tau/sangue , Proteínas tau/líquido cefalorraquidiano , Biomarcadores/sangue , Biomarcadores/líquido cefalorraquidiano , Peptídeos beta-Amiloides/sangue , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Fragmentos de Peptídeos/sangue , Fragmentos de Peptídeos/líquido cefalorraquidiano , Idoso de 80 Anos ou mais