BACKGROUND: Previous studies have suggested that oil-based contrast agents used during hysterosalpingography (HSG) in infertile patients can enhance fertility. However, limited research has investigated the effect of oil-based contrast medium specifically in individuals with endometriosis-related infertility. OBJECTIVE: This study aims to explore the impact of oil-based contrast medium on fertility outcomes in women with endometriosis-related infertility. METHODS: Conducted at the First Affiliated Hospital of Guangxi Medical University (January 2020 to June 2022), the study included 512 patients undergoing HSG. Patients were categorized into oil-based and non-oil-based groups, and after propensity score matching, demographic characteristics were compared. Main outcomes included clinical pregnancy rates, live birth rates, early miscarriage rates, and ectopic pregnancy rates. RESULTS: In our analysis, the Oil-based group showed significantly better outcomes compared to the Non-oil-based group. Specifically, the Oil-based group had higher clinical pregnancy rates (51.39% vs. 27.36%) and increased live birth rates (31.48% vs. 19.93%). This trend held true for expectant treatment, IUI, and IVF/ICSI, except for surgical treatment where no significant difference was observed. After adjusting for various factors using propensity score matching, the Non-oil-based group consistently exhibited lower clinical pregnancy rates compared to the Oil-based group. The Odds Ratio (OR) was 0.38 (95%CI: 0.27-0.55) without adjustment, 0.34 (0.22-0.51) in multivariable analysis, 0.39 (0.27-0.57) using inverse probability of treatment weighting (IPTW), and 0.22 (0.14-0.35) in propensity score matching. CONCLUSION: Oil-based contrast medium used in HSG for women with endometriosis-related infertility is associated with higher clinical pregnancy rates and live birth rates compared to Non-oil-based contrast medium.
Assuntos
Endometriose , Infertilidade Feminina , Gravidez , Humanos , Feminino , Meios de Contraste , Histerossalpingografia , Endometriose/complicações , Endometriose/diagnóstico por imagem , Infertilidade Feminina/diagnóstico por imagem , Infertilidade Feminina/etiologia , Infertilidade Feminina/terapia , Estudos Retrospectivos , China/epidemiologia , Fertilidade , Taxa de Gravidez , Nascido VivoRESUMO
OBJECTIVE: The objective of this study was to investigate whether the use of carbon dioxide (CO2) angiography decreases the intraoperative use of iodine contrast medium (ICM), thereby decreasing the risk of developing postoperative renal damage in patients undergoing iliac branch device (IBD) implantation. METHODS: Patients undergoing IBD implantation at a single tertiary center between May 2013 and August 2019 were screened for inclusion in the study. A cohort of patients in whom an intraoperative imaging protocol using predominantly CO2 was compared with a control group in whom ICM was used (CO2 and ICM groups). Fusion imaging was used in both groups. Retrospective review of the medical charts and all imaging was performed. Variables were expressed as median with interquartile range (IQR) or absolute number and percentage. Wilcoxon-Mann-Whitney and χ2 tests were used to compare continuous and categorical variables, respectively. P values of <0 .05 were considered statistically significant. RESULTS: Twenty-three patients were included in the CO2 group and 21 in the ICM group without significant differences in patient characteristics between the groups. Intraoperative iodine exposure was lower in the CO2 group than in the ICM group (8.2 g [IQR, 7.1-10.9 g) vs 15.8 g (IQR 7.6-21 g); P = 0.015, respectively). There were no differences in technical success, clinical success, fluoroscopy time, and dose-area product in the 2 groups. There were no adverse events that could be related to the intraoperative use of CO2. There was no difference in postoperative survival nor renal function assessment between the groups despite the higher number of accessory renal arteries embolized in the CO2 group (P = 0.221). CONCLUSIONS: Reduction of intraoperative ICM exposure during IBD implantation is feasible through the predominant use of CO2 automated angiography. This can be done safely without affecting the technical success or radiation exposure. The immediate postoperative renal damage was low when a modern intraoperative imaging protocol with ICM was used and was not significantly reduced by the use of CO2. Further and larger studies are needed to investigate the long-term effects. CLINICAL IMPACT: This study aimed to investigate how to minimize intraoperative risk during iliac branched repair exploring the intraoperative use of automated carbon dioxide angiography in order to decrease the use of contrast media protecting renal function and thereby potentially impacting long-term survival.
RESUMO
BACKGROUND: J waves may be augmented by coronary angiography (CAG) or intracoronary drug administration but the underlying mechanism is unknown. PURPOSE: The effect of intracoronary normal saline (NS) on J waves were investigated. PATIENTS AND METHODS: After the standard CAG using iopamidol (IopamiroR Inj), NS was injected into the right coronary artery in 10 patients with and eight patients without J waves at the baseline. The 12-lead ECG was monitored, stored on a computer and retrieved later for measurement of the J wave amplitude before or during the coronary interventions. RESULTS: J waves in leads II, III and aVF at baseline increased significantly in each lead during the right CAG and NS injection into the right coronary artery. The J wave changes were similar between the two interventions and distinct similar alterations were observed in the QRS complex. We postulated that the ischemic myocardium that was induced during CAG or intracoronary NS administration slowed the conduction velocity of depolarization in the perfusion territory and delayed the timing of J waves to appear. Then, the delayed appearance of J waves would be less opposed by electromotive force from other areas resulting in augmentation. CONCLUSION: J wave augmentation was observed during CAG and intracoronary NS administration. As a mechanism of augmentation, we postulated that contrast media and NS induce myocardial ischemia and delay the timing of J waves to a point of less opposition by electromotive force from other areas. HIGHLIGHTS: J wave augmentation has been reported during intracoronary injection of contrast media or drugs. The present study confirmed that normal saline alone was able to augment J waves. Mechanistically, coronary interventions using anoxic solutions can cause regional myocardial ischemia and reduce the conduction velocity of depolarization. Then, delayed J waves are less opposed by the electromotive force from remote areas which leads to augmentation. When a drug is diluted in normal saline and given intracoronarily, changes in J waves can be due to normal saline. The pathophysiological and clinical significance of J waves augmented during coronary interventions need to be established.
Assuntos
Angiografia Coronária , Eletrocardiografia , Isquemia Miocárdica , Solução Salina , Humanos , Masculino , Feminino , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/diagnóstico por imagem , Solução Salina/administração & dosagem , Pessoa de Meia-Idade , Idoso , Injeções Intra-ArteriaisRESUMO
BACKGROUND: Computed tomography angiography (CTA) is a reliable, non-invasive screening method for diagnosing panvascular disease. By using low contrast agent volume, CTA imaging enables one-stop multi-organ scanning, thereby minimizing the potential risk of contrast-induced nephropathy in patients with impaired renal function. PURPOSE: To evaluate the feasibility of one-stop CTA following a heart rate (HR)-based protocol using a low volume of contrast medium (CM) for examination of the coronary, carotid and cerebrovascular arteries. MATERIAL AND METHODS: Sixty patients undergoing coronary carotid, and cerebrovascular CTA after a single injection of CM were recruited and randomly divided into two groups. Group A (n = 30) underwent CTA following a traditional protocol. The timing of the scans in Group B (n = 30) was determined according to the patient's HR. RESULTS: The CT values for the thoracic aorta (432.2 ± 104.28â HU), anterior cerebral artery (303.96 ± 99.29â HU), and right coronary artery (366.70 ± 85.10â HU) in Group A did not differ significantly from those in Group B (445.80 ± 106.13, 293.73 ± 75.25 and 344.13 ± 111.04â HU, respectively). The qualities of most of the scanned images for both groups were scored as 3 or 4 (on a five-point scale). The radiation dose and the volume of CM were significantly higher in Group A (303.05 ± 110.95â mGy) (100â mL) than in Group B (239.46 ± 101.12â mGy) (50â mL). CONCLUSION: The radiation dose and volume of CM were significantly reduced in CTA following the HR-based protocol. The personalized administration of CM also simplified the scanning process.
Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Humanos , Angiografia por Tomografia Computadorizada/métodos , Frequência Cardíaca , Tomografia Computadorizada por Raios X/métodos , Artérias Carótidas , Doses de Radiação , Angiografia Coronária/métodosRESUMO
This study aimed to evaluate the potential reduction in contrast medium utilization using photon-counting detector computed tomography (PCD-CT). One PCD-CT scan (CT1) and three conventional (non-PCD-CT) CT scans (CT2-CT4) were performed using a multi-energy CT phantom that contained eight rods with different iodine concentrations (0.2, 0.5, 1, 2, 5, 10, 15, and 20 mg/ml). The CT values of the seven groups (CT1 for 40, 50, 60, and 70 keV; and CT2-4) were measured. Noise and contrast-to-noise ratio (CNR) were assessed for the eight rods at various iodine concentrations. CT2 and CT1 (40 keV) respectively required 20 mg/ml and 5 mg/ml of iodine, indicating that a comparable contrast effect could be obtained with approximately one-fourth of the contrast medium amount. The standard deviation values increased at lower energy levels irrespective of the iodine concentration. The CNR exhibited a decreasing trend with lower iodine concentrations, while it remained relatively stable across all iodine levels (40-70 keV). This study demonstrated that virtual monochromatic 40 keV images offer a similar contrast effect with a reduced contrast medium amount when compared to conventional CT systems at 120 kV.
Assuntos
Meios de Contraste , Imagens de Fantasmas , Fótons , Tomografia Computadorizada por Raios X , Meios de Contraste/química , Tomografia Computadorizada por Raios X/métodos , Iodo , HumanosRESUMO
OBJECTIVE: The use of computed tomography (CT) in aquarium animals, including elasmobranchs, has increased dramatically. To take advantage of CT, contrast medium is used to enhance internal organs and provide contrast since elasmobranchs lack visceral fat. In this study, the contrast effects of iopamidol were examined for up to 260 days after intravenous administration to establish the time course of the CT values for the target organs in eight mature Cloudy Catsharks Scyliorhinus torazame. METHODS: A micro-CT system was used to measure the CT values of the designated region of interest in the target organs (ventricular cavity, kidneys, liver, gallbladder, ovarian follicles, uterine horn cavity) over time and the eggs laid, following administration of iopamidol (700 mg of iodine/kg). RESULT: The CT values of the ventricular cavity and kidneys peaked at 30 min and showed low values after day 22. The CT values for the liver increased over time and peaked at day 200, whereas values for the gallbladder and ovarian follicles peaked on day 6, with the gallbladder showing a low value and the ovarian follicles still showing a high value on day 260. Computed tomography images with identifiable enhancement within bilateral uterine horns were followed from days 1 to 35. The mean and maximum CT values of yolk and jelly in eggs laid after day 30 were significantly higher than the values for eggs laid up to day 29; embryonic development was confirmed in 88.7% of the eggs. CONCLUSION: There was no mortality or morbidity of the sharks during the experiment, indicating that the administration of iopamidol at 700 mg of iodine/kg did not result in any adverse effects for 260 days. This is the first study to describe the long-term contrast effects of iopamidol, thus contributing new information about the application of contrast studies in Cloudy Catsharks.
Assuntos
Meios de Contraste , Iopamidol , Tubarões , Animais , Meios de Contraste/administração & dosagem , Feminino , Iopamidol/administração & dosagem , Tomografia Computadorizada por Raios X/veterinária , MasculinoRESUMO
PURPOSE: To compare image quality, iodine intake, and radiation dose in overweight and obese patients undergoing abdominal computed tomography (CT) enhancement using different scanning modes and contrast medium. METHODS: Ninety overweight and obese patients (25âkg/m2≤body mass index (BMI)<â30âkg/m2 and BMI≥30âkg/m2) who underwent abdominal CT-enhanced examinations were randomized into three groups (A, B, and C) of 30 each and scanned using gemstone spectral imaging (GSI) +320âmgI/ml, 100âkVp + 370âmgI/ml, and 120âkVp + 370âmgI/ml, respectively. Reconstruct monochromatic energy images of group A at 50-70âkeV (5âkeV interval). The iodine intake and radiation dose of each group were recorded and calculated. The CT values, contrast-to-noise ratios (CNRs), and subjective scores of each subgroup image in group A versus images in groups B and C were by using one-way analysis of variance or Kruskal-Wallis H test, and the optimal keV of group A was selected. RESULTS: The dual-phase CT values and CNRs of each part in group A were higher than or similar to those in groups B and C at 50-60âkeV, and similar to or lower than those in groups B and C at 65âkeV and 70âkeV. The subjective scores of the dual-phase images in group A were lower than those of groups B and C at 50âkeV and 55âkeV, whereas no significant difference was seen at 60-70âkeV. Compared to groups B and C, the iodine intake in group A decreased by 12.5% and 13.3%, respectively. The effective doses in groups A and B were 24.7% and 25.8% lower than those in group C, respectively. CONCLUSION: GSI +320âmgI/ml for abdominal CT-enhanced in overweight patients satisfies image quality while reducing iodine intake and radiation dose, and the optimal keV was 60âkeV.
Assuntos
Meios de Contraste , Obesidade , Sobrepeso , Radiografia Abdominal , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/diagnóstico por imagem , Sobrepeso/diagnóstico por imagem , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso de 80 Anos ou maisRESUMO
OBJECTIVES: To further reduce the contrast medium (CM) dose of full aortic CT angiography (ACTA) imaging using the augmented cycle-consistent adversarial framework (Au-CycleGAN) algorithm. METHODS: We prospectively enrolled 150 consecutive patients with suspected aortic disease. All received ACTA scans of ultra-low-dose CM (ULDCM) protocol and low-dose CM (LDCM) protocol. These data were randomly assigned to the training datasets (n = 100) and the validation datasets (n = 50). The ULDCM images were reconstructed by the Au-CycleGAN algorithm. Then, the AI-based ULDCM images were compared with LDCM images in terms of image quality and diagnostic accuracy. RESULTS: The mean image quality score of each location in the AI-based ULDCM group was higher than that in the ULDCM group but a little lower than that in the LDCM group (all p < 0.05). All AI-based ULDCM images met the diagnostic requirements (score ≥ 3). Except for the image noise, the AI-based ULDCM images had higher attenuation value than the ULDCM and LDCM images as well as higher SNR and CNR in all locations of the aorta analyzed (all p < 0.05). Similar results were also seen in obese patients (BMI > 25, all p < 0.05). Using the findings of LDCM images as the reference, the AI-based ULDCM images showed good diagnostic parameters and no significant differences in any of the analyzed aortic disease diagnoses (all K-values > 0.80, p < 0.05). CONCLUSIONS: The required dose of CM for full ACTA imaging can be reduced to one-third of the CM dose of the LDCM protocol while maintaining image quality and diagnostic accuracy using the Au-CycleGAN algorithm. KEY POINTS: ⢠The required dose of contrast medium (CM) for full ACTA imaging can be reduced to one-third of the CM dose of the low-dose contrast medium (LDCM) protocol using the Au-CycleGAN algorithm. ⢠Except for the image noise, the AI-based ultra-low-dose contrast medium (ULDCM) images had better quantitative image quality parameters than the ULDCM and LDCM images. ⢠No significant diagnostic differences were noted between the AI-based ULDCM and LDCM images regarding all the analyzed aortic disease diagnoses.
Assuntos
Doenças da Aorta , Angiografia por Tomografia Computadorizada , Humanos , Angiografia por Tomografia Computadorizada/métodos , Doses de Radiação , Inteligência Artificial , Meios de Contraste , Aorta/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodosRESUMO
BACKGROUND. Patients with cancer undergo frequent CT examinations with iodinated contrast media and may be uniquely predisposed to contrast-associated acute kidney injury (CA-AKI). OBJECTIVE. The purpose of this study was to develop and validate a model for predicting the risk of CA-AKI after contrast-enhanced CT in patients with cancer. METHODS. This retrospective study included 25,184 adult patients (12,153 men, 13,031 women; mean age, 62.3 ± 13.7 [SD] years) with cancer who underwent 46,593 contrast-enhanced CT examinations between January 1, 2016, and June 20, 2020, at one of three academic medical centers. Information was recorded regarding demographics, malignancy type, medication use, baseline laboratory values, and comorbid conditions. CA-AKI was defined as a 0.3-mg/dL or greater increase in serum creatinine level from baseline within 48 hours after CT or a 1.5-fold or greater increase in the peak measurement within 14 days after CT. Multivariable models accounting for correlated data were used to identify risk factors for CA-AKI. A risk score for predicting CA-AKI was generated in a development set (n = 30,926) and tested in a validation set (n = 15,667). RESULTS. CA-AKI occurred after 5.8% (2682/46,593) of CT examinations. The final multivariable model for predicting CA-AKI included hematologic malignancy, diuretic use, angiotensin-converting enzyme inhibitor or angiotensin receptor blocker use, chronic kidney disease (CKD) stage 3a, CKD stage 3b, CKD stage 4 or 5, serum albumin level less than 3.0 g/dL, platelet count less than 150 × 103/µL, 1+ or greater proteinuria on baseline urinalysis, diabetes mellitus, heart failure, and contrast medium volume 100 mL or greater. A risk score (range, 0-53 points) was generated with these variables. The most points (13) were for CKD stage 4 or 5 and for albumin level less than 3 g/dL. The frequency of CA-AKI progressively increased in higher risk categories. For example, in the validation set, CA-AKI occurred after 2.2% of CT examinations in the lowest risk category (score ≤ 4) and after 32.7% of CT examinations in the highest risk category (score ≥ 30). The Hosmer-Lemeshow test result indicated that the risk score was a good fit (p = .40). CONCLUSION. A risk model in which readily available clinical data are used to predict the likelihood of CA-AKI after contrast-enhanced CT in patients with cancer was developed and validated. CLINICAL IMPACT. The model may help facilitate appropriate implementation of preventive measures in the care of patients at high risk of CA-AKI.
Assuntos
Injúria Renal Aguda , Neoplasias , Insuficiência Renal Crônica , Masculino , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Meios de Contraste/efeitos adversos , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico por imagem , Injúria Renal Aguda/epidemiologia , Fatores de Risco , Neoplasias/complicações , Tomografia Computadorizada por Raios X/efeitos adversosRESUMO
BACKGROUND: J-waves may be observed during coronary angiography (CAG) or intracoronary acetylcholine (ACh) administration, but their significance is unknown. METHODS: Forty-nine patients, 59.1 ± 11.5 years old and 59% male, were studied on suspicion of vasospastic angina, and J wave dynamicity was compared between CAG and Ach administration. RESULTS: Diagnostic (≥0.1 mV) or nondiagnostic (<0.1 mV) J waves in 9 and 3 patients, respectively, were augmented, and J waves were newly observed in 2 patients during CAG and Ach administration. Similar changes in the J-wave amplitude were observed: from 0.10 ± 0.09 mV to 0.20 ± 0.15 mV (p < .002) and from 0.10 ± 0.10 mV to 0.20 ± 0.16 mV (p < .001) during CAG and Ach administration, respectively. J waves were located in the inferior leads and changed only during the right coronary interventions. In the remaining 35 patients, J waves were absent before and during the coronary interventions. Augmentation of J waves was found when the RR interval was shortened in some patients. Injection of anoxic media into the coronary artery might induce a conduction delay from myocardial ischemia that manifests as augmentation or new occurrence of J waves. CONCLUSIONS: Both CAG and intracoronary Ach administration affected J waves similarly in the same individuals. A myocardial ischemia-induced conduction delay may be responsible for the changes in J waves, but further studies are needed.
Assuntos
Doença da Artéria Coronariana , Vasoespasmo Coronário , Isquemia Miocárdica , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Acetilcolina/efeitos adversos , Angiografia Coronária , Arritmias Cardíacas , Vasos Coronários/diagnóstico por imagem , Vasoespasmo Coronário/diagnóstico por imagem , Vasoespasmo Coronário/induzido quimicamenteRESUMO
BACKGROUND: In women with unexplained infertility, tubal flushing with oil-based contrast during hysterosalpingography leads to significantly more live births as compared to tubal flushing with water-based contrast during hysterosalpingography. However, it is unknown whether incorporating tubal flushing with oil-based contrast in the initial fertility work-up results to a reduced time to conception leading to live birth when compared to delayed tubal flushing that is performed six months after the initial fertility work-up. We also aim to evaluate the effectiveness of tubal flushing with oil-based contrast during hysterosalpingography versus no tubal flushing in the first six months of the study. METHODS: This study will be an investigator-initiated, open-label, international, multicenter, randomized controlled trial with a planned economic analysis alongside the study. Infertile women between 18 and 39 years of age, who have an ovulatory cycle, who are at low risk for tubal pathology and have been advised expectant management for at least six months (based on the Hunault prediction score) will be included in this study. Eligible women will be randomly allocated (1:1) to immediate tubal flushing (intervention) versus delayed tubal flushing (control group) by using web-based block randomization stratified per study center. The primary outcome is time to conception leading to live birth with conception within twelve months after randomization. We assess the cumulative conception rate at six and twelve months as two co-primary outcomes. Secondary outcomes include ongoing pregnancy rate, live birth rate, miscarriage rate, ectopic pregnancy rate, number of complications, procedural pain score and cost-effectiveness. To demonstrate or refute a shorter time to pregnancy of three months with a power of 90%, a sample size of 554 women is calculated. DISCUSSION: The H2Oil-timing study will provide insight into whether tubal flushing with oil-based contrast during hysterosalpingography should be incorporated in the initial fertility work-up in women with unexplained infertility as a therapeutic procedure. If this multicenter RCT shows that tubal flushing with oil-based contrast incorporated in the initial fertility work-up reduces time to conception and is a cost-effective strategy, the results may lead to adjustments of (inter)national guidelines and change clinical practice. TRIAL REGISTRATION NUMBER: The study was retrospectively registered in International Clinical Trials Registry Platform (Main ID: EUCTR2018-004153-24-NL).
Assuntos
Infertilidade Feminina , Feminino , Humanos , Gravidez , Meios de Contraste/uso terapêutico , Tubas Uterinas/diagnóstico por imagem , Histerossalpingografia/efeitos adversos , Infertilidade Feminina/etiologia , Estudos Multicêntricos como Assunto , Taxa de Gravidez , Ensaios Clínicos Controlados Aleatórios como AssuntoRESUMO
BACKGROUND: Arterial enhancement after contrast injection affects the quality of computed tomography angiography (CTA) images. PURPOSE: To evaluate whether the dilution of contrast medium (CM) for CTA increases arterial enhancement after the adjustment of iodine concentration as per the patient's body weight (BW). MATERIAL AND METHODS: We retrospectively studied 700 patients who underwent coronary CTA. The first 350 consecutive patients underwent standard CTA with a fixed iodine concentration, whereas the remaining 350 underwent CTA with a diluted CM injection. All patients were classified into three groups according to their BW (<55, 55-65, and 66-73â kg). The mean and proportion of contrast enhancements (CEs) in the ascending aorta of ≥350 Hounsfield units (HUs) (CE350) were compared between the standard CTA and diluted CM injection and among the BW groups. The associations between BW and CE were analyzed using linear regression. RESULTS: Receiving diluted CM increased the mean CE in the <55-kg group (403.4 ± 55.4 HU vs. 382.8 ± 59.3 HU; P < 0.01) but not in the groups with heavier BW. The proportion of patients with CE350 increased with BW (<55â kg = 71%, 55-65â kg = 84%, and 66-73â kg = 91%) and increased after dilution (86%, 93%, and 96%, respectively). After CM dilution, the correlation between BW and CE among patients undergoing CTA decreased from 0.37 to 0.22 (P < 0.05). CONCLUSION: CM dilution for CTA improves arterial enhancement.
Assuntos
Angiografia por Tomografia Computadorizada , Iodo , Humanos , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Peso CorporalRESUMO
Little is known about whether preventative practices for post-contrast acute kidney injury (PC-AKI) recommended in guidelines have been adopted in clinical practice and translated into a lower incidence of PC-AKI. The aim of this study was to examine the yearly trends in the incidence of PC-AKI, and comorbidities and care practices associated with PC-AKI in hospitalized patients who received intravenous administration of iodinated contrast medium (ICM). Adult patients receiving intravenous ICM at the Second Xiangya Hospital of Central South University in China between 2015 and 2021 were included. Temporal trends in the incidence and risk factors for PC-AKI were evaluated using logistic regression analyses with adjustments for relevant variables. The incidence of PC-AKI has declined significantly from 5.3% in 2015 to 4.1% in 2021 (p < 0.001). This decreasing trend persisted after extensive multivariable adjustments. Of the comorbidities associated with PC-AKI, the proportion of patients with congestive heart failure or hypertension increased, while the proportion of patients older than 75 years, or with an estimated glomerular filtration rate (eGFR) < 30 mL/min/1.73 m2, diabetic nephropathy, or renal stone disease decreased. Among the care practices associated with PC-AKI, the proportion of patients using nephrotoxic drugs decreased, whereas the proportion of patients receiving intravenous fluids > 1000 mL on the day of ICM administration or using iso-osmolar ICM increased. In conclusion, a declining trend in PC-AKI incidence was observed in patients receiving intravenous ICM between 2015 and 2021, which may be related to increased awareness and efforts to prevent PC-AKI.
Assuntos
Injúria Renal Aguda , Nefropatias Diabéticas , Adulto , Humanos , Administração Intravenosa , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/prevenção & controle , China , Meios de Contraste/efeitos adversosRESUMO
Although main criteria like non-rim enhancement in the arterial phase, non-peripheral washout, enhancing envelope, lesion size, and threshold growth have definitions and interpretations in the Liver Imaging Reporting and Data System, there are still some problems and pitfalls that clinicians and radiologists need to understand and avoid when assessing the main criteria based on gadoxetate disodium in clinical work-up. This article reviews the existing problems and current solutions in the assessment of the main criteria based on the hepatic contrast agent gadoxetate disodium.
Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Meios de Contraste , Neoplasias Hepáticas/diagnóstico por imagem , HepatócitosRESUMO
BACKGROUND: There have been few studies published on the use of contrast media (CM) in metformin-treated patients. In this study, we conducted a systematic review and meta-analysis to investigate the relationship between metformin and contrast-induced acute kidney injury (CI-AKI). METHODS: A comprehensive search of the Medline, PubMed, Embase, and Web of Science databases for literature on associations between metformin use and CI-AKI incidence was conducted. The pooled odds ratio (OR), or relative risk, as well as the corresponding 95% confidence intervals (CIs), was calculated to assess the relationship between metformin and CI-AKI risk as well as the incidence of lactic acidosis (LA). RESULTS: In total, seven studies met our eligibility criteria on associations between metformin use and CI-AKI incidence, comprising 2,325 individuals, with 279 new cases of CI-AKI exposed to CM. The pooled analysis revealed no statistically significant increase in the risk of CI-AKI development in patients who used metformin continuously (random-effects OR: 1.15, 95% CI: 0.70-1.90, p = 0.57). No cases of LA that occurred during CM exposure were reported. CONCLUSION: Metformin can be safely used in patients with moderate renal impairment (eGFR ≥ 30 mL/min/1.73 m2) during CM exposure.
Assuntos
Injúria Renal Aguda , Metformina , Humanos , Metformina/efeitos adversos , Meios de Contraste/efeitos adversos , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/epidemiologia , Incidência , Razão de ChancesRESUMO
BACKGROUND: Atherosclerosis is a common cardiovascular disease in parrots but the antemortem diagnosis is challenging. In human medicine, computed tomography angiography (CTA) has been used widely for the diagnosis of atherosclerosis. By adjusting the injection rate and total dose of contrast medium, the image quality can be improved. To test the effects of different injection conditions on the image quality of major arteries, 10 African grey parrots (Psittacus erithacus) were used. Three injection rates (0.3, 0.4, 0.5 mL/s) and three doses (740, 370, 222 mg of iodine/bird) were tested while the other variables of the studies were fixed. RESULT: A higher injection dose led to a significantly higher attenuation, image noise and diameter, with a lower signal-to-noise ratio and contrast-to-noise ratio of the six major arteries. The 370 mg of iodine/bird group showed significantly better subjective image quality. Furthermore, with increasing injection rates, the prevalence of heterogeneity decreased. However, we found an increased risk of injection failure for the 0.5 mL/s groups. CONCLUSION: We recommend a combination of 370 mg of iodine/bird with 0.4 mL/s for clinical use to achieve better image quality for CTA.
Assuntos
Angiografia por Tomografia Computadorizada , Iodo , Animais , Humanos , Angiografia por Tomografia Computadorizada/veterináriaRESUMO
In cryoballoon ablation (CBA), a contrast medium is commonly used to confirm balloon occlusion of the pulmonary veins (PVs). However, a contrast medium cannot always be used in patients with renal dysfunction and allergy. The present study aimed to assess the efficacy and safety of CBA without the use of a contrast medium. We retrospectively examined consecutive patients with paroxysmal atrial fibrillation (PAF) who underwent first-time CBA. We compared the procedural results and outcomes in patients for whom a contrast medium was used (contrast group) and those from whom a contrast medium was not used (non-contrast group). In the non-contrast group, we used saline injection on the intracardiac echocardiography and pressure wave monitoring for PV occlusion. Fifty patients (200 PVs) and 22 patients (88 PVs) underwent CBA with and without a contrast medium, respectively. The success rate of PV isolation with CBA alone was 93% and 90% in the non-contrast and contrast groups, respectively (p = 0.40). The fluoroscopy time and nadir temperature were significantly lower in the non-contrast group as compared to that in the contrast group. The recurrence rate 1 year after ablation did not differ between the two groups (18% vs. 18%, p > 0.99). Furthermore, the number of reconnected PVs in patients with recurrence was significantly lower in the non-contrast group than in the contrast group (6% vs. 36%, p = 0.017). In conclusion, CBA using the intracardiac echocardiography and pressure monitoring approach without the use of a contrast medium was safe and efficient.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Ecocardiografia/métodos , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND: Noncardiogenic pulmonary edema (NCPE) is a rare and life-threatening allergy-like reaction to the intravascular injection of a nonionic radiographic agent. We first describe a very rare case of fatal NCPE after the intravenous injection of nonionic, iso-osmolar iodine contrast media. Case presentation A 55-year-old male patient was admitted to the hospital with esophageal cancer. After the intravenous administration of 100 mL iodixanol, the patient first exhibited digestive tract symptoms, including abdominal pain, diarrhea, and vomiting, with no dyspnea, rash, itching, or throat edema. He received anti-allergy treatment, but his symptoms did not improve; instead, he further developed pulmonary edema. Arterial blood gas analysis results were as follows: pH, 7.08; PO2, 70 mm Hg; PCO2, 40 mm Hg; and SaO2, 52%. Then, the patient received emergent tracheal intubation and ventilation to assist breathing, and he was transferred to the intensive care unit (ICU) for further treatment. In the ICU, the patient developed shock and respiratory and circulatory failure; therefore, he received shock resuscitation, acidosis correction, muscle relaxants to lower the work of breathing, and cardiotonic therapy. The patient eventually died. During the ICU period, emergency bedside color ultrasound showed a diffuse B line in both lungs, and the size of the cardiac cavity was normal, but the ventricular rate was extremely fast. Chest radiography showed pulmonary edema with a normal cardiac silhouette, and the brain natriuretic peptide (BNP) level was in the normal range. CONCLUSIONS: NCPE is a rare and critical allergy-like reaction to the use of a nonionic iso-osmolar radiocontrast contrast medium. Clinicians should pay very close attention to digestive tract manifestations during the medical observation of patients, as gastrointestinal manifestations may be the prodromal symptoms of NCPE caused by iso-osmolar contrast medium injection.
Assuntos
Iodo , Edema Pulmonar , Meios de Contraste/efeitos adversos , Humanos , Injeções Intravenosas , Pulmão , Masculino , Pessoa de Meia-Idade , Edema Pulmonar/induzido quimicamente , Edema Pulmonar/diagnóstico por imagemRESUMO
BACKGROUND: The low-tube-voltage scan generally needs a higher tube current than the conventional 120 kVp to maintain the image noise. In addition, the low-tube-voltage scan increases the photoelectric effect, which increases the radiation absorption in organs. PURPOSE: To compare the organ radiation dose caused by iodine contrast medium between low tube voltage with low contrast medium and that of conventional 120-kVp protocol with standard contrast medium. MATERIAL AND METHODS: After the propensity-matching analysis, 66 patients were enrolled including 33 patients with 120 kVp and 600 mgI/kg and 33 patients with 80 kVp and 300 mgI/kg (50% iodine reduction). The pre- and post-contrast phases were assessed in all patients. The Monte Carlo simulation tool was used to simulate the radiation dose. The computed tomography (CT) numbers for 10 organs and the organ doses were measured. The organ doses were normalized by the volume CT dose index, and the 120-kVp protocol was compared with the 80-kVp protocol. RESULTS: On contrast-enhanced CT, there were no significant differences in the mean CT numbers of the organs between 80-kVp and 120-kVp protocols except for the pancreas, kidneys, and small intestine. The normalized organ doses at 80 kVp were significantly lower than those of 120 kVp in all organs (e.g. liver, 1.6 vs. 1.9; pancreas, 1.5 vs. 1.8; spleen, 1.7 vs. 2.0) on contrast-enhanced CT. CONCLUSION: The low tube voltage with low-contrast-medium protocol significantly reduces organ doses at the same volume CT dose index setting compared with conventional 120-kVp protocol with standard contrast medium on contrast-enhanced CT.
Assuntos
Meios de Contraste , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/instrumentação , Imagem Corporal Total/métodos , Adulto , Feminino , Humanos , Iodo , Masculino , Pessoa de Meia-IdadeRESUMO
Contrast-induced acute kidney injury (CI-AKI) is a common clinical complication and an important cause of increased mortality, prolonged hospitalization, and increased medical costs. For taking effective interventions in CI-AKI, early diagnosis and active prevention are of key importance. Currently, early CI-AKI detection depends on serum creatinine (Scr) levels, which lags behind the actual time of renal injury and seriously affects early diagnosis and interventions. MicroRNA (miRNA) has been found to be a useful biomarker in early CI-AKI diagnosis. Several studies have reported on tissue and time-specific miRNAs in AKI as effective diagnostic biomarkers and potential therapeutic targets, but there are only a few studies on miRNA in CI-AKI. However, these studies are preliminary exploratory investigations on changes in miRNA expression in CI-AKI, and whether these specific miRNAs can be used as biomarkers for early CI-AKI diagnosis and as clinical therapeutic targets requires systematic and in-depth studies. Therefore, more sensitive and specific miRNAs of CI-AKI could be discovered, providing newer options and development directions for early diagnosis and intervention in clinical CI-AKI practice. This review evaluates the research progress on specific miRNAs in the early diagnosis of CI-AKI with an aim of providing basic data for the clinical application of these molecular markers in CI-AKI.