Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 13.485
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38587261

RESUMO

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bioprótese/efeitos adversos , Insuficiência Cardíaca , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
2.
Proc Natl Acad Sci U S A ; 120(1): e2219054120, 2023 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-36574676

RESUMO

Bioprosthetic heart valves (BHV), made from glutaraldehyde-fixed xenografts, are widely used for surgical and transcatheter valve interventions but suffer from limited durability due to structural valve degeneration (SVD). We focused on metabolic syndrome (MetS), a risk factor for SVD and a highly prevalent phenotype in patients affected by valvular heart disease with a well-recognized cluster of comorbidities. Multicenter patient data (N = 251) revealed that patients with MetS were at significantly higher risk of accelerated SVD and required BHV replacement sooner. Using a next-generation proteomics approach, we identified significantly differential proteomes from leaflets of explanted BHV from MetS and non-MetS patients (N = 24). Given the significance of protein infiltration in MetS-induced SVD, we then demonstrated the protective effects of polyoxazoline modification of BHV leaflets to mitigate MetS-induced BHV biomaterial degeneration (calcification, tissue cross-linking, and microstructural changes) in an ex vivo serum model and an in vivo with MetS rat subcutaneous implants.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Síndrome Metabólica , Humanos , Animais , Ratos , Síndrome Metabólica/complicações , Valvas Cardíacas , Fatores de Risco , Valva Aórtica/cirurgia
3.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Assuntos
Endocardite , Falha de Prótese , Infecções Relacionadas à Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Endocardite/cirurgia , Endocardite/mortalidade , Remoção de Dispositivo , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
4.
Small ; 20(23): e2309844, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38279610

RESUMO

Valvular heart disease (VHD) has become a burden and a growing public health problem in humans, causing significant morbidity and mortality worldwide. An increasing number of patients with severe VHD need to undergo heart valve replacement surgery, and artificial heart valves are in high demand. However, allogeneic valves from donors are lacking and cannot meet clinical practice needs. A mechanical heart valve can activate the coagulation pathway after contact with blood after implantation in the cardiovascular system, leading to thrombosis. Therefore, bioprosthetic heart valves (BHVs) are still a promising way to solve this problem. However, there are still challenges in the use of BHVs. For example, their longevity is still unsatisfactory due to the defects, such as thrombosis, structural valve degeneration, calcification, insufficient re-endothelialization, and the inflammatory response. Therefore, strategies and methods are needed to effectively improve the biocompatibility and longevity of BHVs. This review describes the recent research advances in BHVs and strategies to improve their biocompatibility and longevity.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Humanos , Animais , Materiais Biocompatíveis/química , Valvas Cardíacas
5.
Curr Opin Cardiol ; 39(5): 457-464, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38899782

RESUMO

PURPOSE OF REVIEW: Subclinical leaflet thrombosis (SLT) is often an incidental finding characterized by a thin layer of thrombus involving one, two or three leaflets, with typical appearance on multi-detector computed tomography (MDCT) of hypo-attenuating defect at the aortic side of the leaflet, also called hypo-attenuating leaflet thickening (HALT). SLT may occur following both transcatheter aortic replacement (TAVR) or biological surgical aortic valve replacement (SAVR). The aim of this review is to present an overview of the current state of knowledge on the incidence, diagnosis, clinical impact, and management of SLT following TAVR or SAVR. RECENT FINDINGS: SLT occurs in 10-20% of patients following TAVR and is somewhat more frequent than following SAVR (5-15%). SLT may regress spontaneously without treatment in about 50% of the cases but may also progress to clinically significant valve thrombosis in some cases. Oral anticoagulation with vitamin K antagonist is reasonable if SLT is detected by echocardiography and/or MDCT during follow-up and is generally efficient to reverse SLT. SLT is associated with mild increase in the risk of stroke but has no impact on survival. SLT has been linked with accelerated structural valve deterioration and may thus impact valve durability and long-term outcomes. SUMMARY: SLT is often an incidental finding on echocardiography or MDCT that occurs in 10-20% of patients following TAVR or 5-15% following biological SAVR and is associated with a mild increase in the risk of thrombo-embolic event with no significant impact on mortality but may be associated with reduced valve durability.


Assuntos
Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Trombose/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Complicações Pós-Operatórias/etiologia , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada Multidetectores/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos
6.
Catheter Cardiovasc Interv ; 103(1): 234-237, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37890002

RESUMO

Transcatheter mitral valve-in-valve (ViV) has emerged as a safe and effective therapeutic option for patients with a degenerated mitral bioprosthesis. As procedural techniques mature and operator experience improve, there is a push to adopt a "minimalist" approach of using conscious sedation instead of general anesthesia for faster recovery. The heavy reliance on fluoroscopy for ViV deployment makes feasible the use of intracardiac echocardiography (ICE) instead of transesophageal echocardiography for other procedural imaging requirements. We hereby use a case example to illustrate a step-by-step approach of using four-dimensional ICE to guide transcatheter mitral ViV under conscious sedation.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Ecocardiografia Transesofagiana , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Falha de Prótese
7.
Catheter Cardiovasc Interv ; 104(2): 419-421, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38880999

RESUMO

Nowadays, the long-life management of patients with aortic stenosis has emerged as one of the most debated issues. Transcatheter aortic valve replacement is more frequently performed in younger patients with lower surgical risk, and also the number of valve-in-valve (ViV) procedures has increased in the last few years. However, coronary obstruction is the most dreadful complication related to this procedure. To prevent coronary obstruction in the context of transcatheter aortic ViV implantation, the BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) technique was developed. Although effective, BASILICA is complex and time-consuming. Hence, simpler, reproducible, and faster strategies are desirable. Here we present a promising simplified BASILICA technique employing an Armada Balloon to perform the leaflet laceration.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Doença Iatrogênica
8.
Catheter Cardiovasc Interv ; 103(7): 1111-1124, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38591535

RESUMO

BACKGROUND: The dry-pericardium Vienna transcatheter aortic valve system is repositionable and retrievable, already premounted on the delivery system, eliminating the need for assembly and crimping of the device before valve implantation. METHODS: The VIVA first-in-human feasibility study, a prospective, nonrandomized, single-center trial, evaluated the Vienna aortic valve in 10 patients with severe symptomatic aortic stenosis, who were at intermediate or high surgical risk. This study, registered at ClinicalTrials.gov (NCT04861805), focused on the safety, feasibility, clinical and hemodynamic performance of the Vienna system up to 1-year follow-up. RESULTS: The mean patient age was 79 ± 5 years, 60% male. Valve sizes used: 26 mm (10%), 29 mm (30%), 31 mm (60%). Key hemodynamic improvements were significant: mean aortic valve pressure gradient (mmHg) decreased from 48.7 to 8.1, aortic valve area (cm2) increased from 0.75 to 1.91, and maximum jet velocity through the aortic valve (m/s) decreased from 4.41 to 1.95 (p < 0.0001). No moderate/severe paravalvular leakage was observed, and computed tomography scans revealed no evidence of hypo-attenuated leaflet thickening. The study recorded one life-threatening bleeding event, two cases requiring postprocedural pacemaker implantation, and three ischemic events, with only one causing lasting neurological impairment. Importantly, there were no cases of cardiovascular mortality and only one noncardiovascular death, which was confirmed as unrelated to the device. CONCLUSIONS: The study indicates the Vienna valve as a potential option for severe symptomatic aortic stenosis, designed to streamline the procedure and potentially lower healthcare costs by reducing resource and equipment needs, also procedural errors. Further research is essential to thoroughly evaluate its safety and efficacy.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estudos de Viabilidade , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Idoso , Feminino , Estudos Prospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Índice de Gravidade de Doença , Recuperação de Função Fisiológica , Bioprótese , Fatores de Risco
9.
Catheter Cardiovasc Interv ; 103(7): 1156-1158, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38529691

RESUMO

Subclinical bioprosthetic valve thrombosis (BPVT) is a relatively common finding in asymptomatic patients during follow-up imaging. However, its clinical significance is unclear. Data from registries associate BPVT with elevated valve gradients, thromboembolic complications, recurrence, and valve degeneration. Given the dynamic nature of the disease process, management is challenging. The duration of anticoagulation is unpredictable, and the need for frequent monitoring of BPVT, even in subclinical scenarios, is unclear. Our report is shedding the light on the clinical implications BPVT.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Recidiva , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Resultado do Tratamento , Trombose/etiologia , Trombose/diagnóstico por imagem , Idoso de 80 Anos ou mais , Masculino , Desenho de Prótese , Feminino , Anticoagulantes/uso terapêutico , Idoso , Fatores de Tempo
10.
Catheter Cardiovasc Interv ; 103(6): 1069-1073, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38584521

RESUMO

An 86-year-old female with history of surgical aortic valve replacement presented with clinical signs of heart failure. Echocardiography revealed a reduction in left ventricular systolic function and severe bioprosthetic aortic valve dysfunction. This is the first reported case of valve-in-valve transcatheter aortic valve replacement with concomitant undermining iatrogenic coronary obstruction with radiofrequency needle procedure in a surgical bioprosthetic valve.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Doença Iatrogênica , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Ablação por Cateter/efeitos adversos , Falha de Prótese , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/terapia , Agulhas , Função Ventricular Esquerda , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Oclusão Coronária/fisiopatologia , Angiografia Coronária
11.
Catheter Cardiovasc Interv ; 103(7): 1159-1164, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38639138

RESUMO

Despite progressively uncommon in Western countries, rheumatic heart disease still portrays a significant global burden. In elderly or high-surgical risk patients, plurivalvular disease may require a complex percutaneous approach. Transcatheter aortic valve implantation (TAVI) in patients with previous monoleaflet mitral prosthesis is challenging due to interference between the aortic valve and the rigid mitral mechanical prosthesis "ring." Prior cases report the use of CoreValve or Edwards Sapien aortic valves in patients with adequate mitro-aortic distance. Performing a second major procedure, such as tricuspid valve-in-valve (TVIV), sequentially during a single percutaneous intervention, increases treatment complexity. An 83-year-old woman with rheumatic heart disease, with previous implantation of a Bjork-Shiley monoleaflet mitral prosthesis, and Carpentier-Edwards 29 tricuspid bioprosthesis presented with decompensated heart failure due to severe aortic stenosis and tricuspid bioprosthesis stenosis. After HeartTeam discussion, the patient was deemed as inoperable due to a prohibitive surgical risk. As an alternative, a TAVI (Navitor FlexNav) and a transcatheter TVIV replacement (Edwards Sapiens 3 Ultra) were discussed and proposed, with both techniques being performed sequentially in a single procedure. TAVI in a patient with a previous monoleaflet mitral mechanical prosthesis and TVIV may be a feasible approach in inoperable patients with plurivalvular disease.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Desenho de Prótese , Cardiopatia Reumática , Substituição da Valva Aórtica Transcateter , Valva Tricúspide , Humanos , Feminino , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Valva Tricúspide/fisiopatologia , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Cardiopatia Reumática/diagnóstico por imagem , Cardiopatia Reumática/fisiopatologia , Cardiopatia Reumática/cirurgia , Cardiopatia Reumática/terapia , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Recuperação de Função Fisiológica , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico por imagem
12.
Xenotransplantation ; 31(1): e12845, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38407937

RESUMO

The 2023 IXA conference, hosted in San Diego, CA, brimmed with excitement against the backdrop of recent innovations in both the pre-clinical and clinical realms with several first-in-human applications of xenotransplantation. The theme, "Pigs are flying," alluded to the adage that xenotransplantation would only become a clinical reality "when pigs fly," suggesting a day that might never come. The event witnessed significant attendance, with 600 participants-the highest in the history of an IXA-IPITA joint congress. Among the attendees were members of the Food and Drug Administration (FDA), the National Institutes of Health (NIH), and corporate sponsors deeply engaged in the field. We summarize the latest topics from the congress, ranging from the pros/cons of decedent models of xenotransplantation and genetic engineering of porcine heart valves, solid organs, and cells for clinical translation and their regulatory and ethical landscape.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Estados Unidos , Suínos , Animais , Humanos , Transplante Heterólogo , Engenharia Genética , United States Food and Drug Administration
13.
Eur J Vasc Endovasc Surg ; 67(6): 997-1005, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38341175

RESUMO

OBJECTIVE: This study examines outcome and durability of physician made bovine pericardial tube grafts in aortic infections in all anatomical locations. METHODS: This was a retrospective and prospective international multicentre study. Peri-operative and long term outcomes of patients undergoing in situ aortic reconstruction for native or graft infections with physician made bovine pericardial tube grafts between January 2008 and December 2020 in four European tertiary referral centres were analysed. The primary endpoint was recurrent aortic infection. Secondary endpoints were persistent infection, aortic re-operation for infection, graft related complications, and death. RESULTS: One hundred and sixty eight patients (77% male, mean age 67 ± 11 years) were identified: 38 (23%) with native and 130 (77%) with aortic graft infection. The thirty day mortality rate was 15% (n = 26) overall, 11% (n = 4), and 17% (n = 22) for native and aortic graft infections, respectively (p = .45). Median follow up was 26 months (interquartile range [IQR] 10, 51). Estimated survival at one, two, three, and five years was 64%, 60%, 57%, and 50%, and significantly better for native (81%, 77%, 77%, and 69%) than for graft infections (58%, 55%, 51%, and 44%; p = .011). Nine patients (5.3%) had persistent infection and 10 patients (6%) had aortic re-infection after a median of 10 months (IQR 5, 22), resulting in an estimated freedom from re-infection at one, two, three, and five years of 94%, 92%, 90%, and 86%. Estimated freedom from graft complications at one, two, three, and five years was 91%, 89%, 87%, and 87%. CONCLUSION: This multicentre study demonstrates low re-infection rates when using physician made bovine pericardial tube grafts, comparable to those of other biological grafts. The rate of graft complications, mainly anastomotic aneurysms and stenoses, was low, while graft degeneration was absent. Physician made bovine pericardial tube grafts are an excellent tool for in situ reconstruction in the setting of native aortic infection or aortic graft infection.


Assuntos
Bioprótese , Implante de Prótese Vascular , Prótese Vascular , Pericárdio , Infecções Relacionadas à Prótese , Reoperação , Humanos , Masculino , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/microbiologia , Idoso , Feminino , Prótese Vascular/efeitos adversos , Bovinos , Pericárdio/transplante , Estudos Retrospectivos , Pessoa de Meia-Idade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Europa (Continente) , Bioprótese/efeitos adversos , Reoperação/estatística & dados numéricos , Estudos Prospectivos , Animais , Resultado do Tratamento , Recidiva , Desenho de Prótese , Aorta/cirurgia , Fatores de Tempo
14.
Circ J ; 88(4): 549-558, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-36709983

RESUMO

BACKGROUND: This study analyzed the safety and performance of the Perceval valve for aortic valve replacement (AVR) in patients at 1 year after undergoing aortic stenosis (AS) treatment, and its effect on significant declines in the platelet count during the immediate postoperative period.Methods and Results: Data were collected retrospectively for the initial 121 patients (median age 77 years; 47.1% females) who underwent Perceval sutureless AVR between May 2019 and July 2022. Implantation was successful in all (100%), with median cross-clamp and CPB times of 59 and 100 min, respectively. Postoperative thrombocytopenia (platelet count <50×103/µL) was noted in 80 (66.1%) patients. Multivariate analysis showed advanced age (>80 years), preoperative low platelet count (<200×103/µL), and a sternotomy approach as significant risk factors for postoperative thrombocytopenia. One (0.8%) patient died within 30 days after the procedure. The 2-year site-reported event rate was 14% (n=17) for all-cause mortality, 0.8% (n=1) for cardiac mortality, 4.1% (n=5) for stroke, and 1.7% (n=2) for endocarditis and valve-related reoperation; there were no instances of paravalvular leakage or structural valve deterioration. CONCLUSIONS: Thrombocytopenia was common after Perceval sutureless AVR, although its impact was not significant. Although Perceval sutureless AVR was found to be a safe and effective option, preoperative assessment of potential bleeding should be performed and the Perceval valve should not be used for patients with a high bleeding risk.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Trombocitopenia , Feminino , Humanos , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Trombocitopenia/etiologia , Desenho de Prótese , Bioprótese/efeitos adversos
15.
Circ J ; 88(4): 559-567, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37019644

RESUMO

BACKGROUND: Studies of the influence of smaller body type on the severity of prosthesis-patient mismatch (PPM) after small-sized surgical aortic valve replacement (SAVR) are few, but the issue is particularly relevant for Asian patients.Methods and Results: 695 patients who underwent SAVR with bioprosthetic valves had their hemodynamic valve performance analyzed at 3 months, 1 year, 3 years, and 5 years after operation, and clinical outcomes were assessed. The patients were stratified into 3 valve size groups: 19/21, 23, and 25/27 mm. A smaller valve was associated with higher mean pressure gradients at the 4 time points after operation (P trend <0.05). However, the 3 valve size groups demonstrated no significant differences in the risk of clinical events. At none of the time points did patients with projected PPM show increased mean pressure gradients (P>0.05), whereas patients with measured PPM did (P<0.05). Compared with patients with projected PPM, those with measured PPM demonstrated higher rates of infective endocarditis readmission (adjusted hazard ratio [aHR] 3.31, 95% confidence interval [CI] 1.06-10.39) and a higher risk of composite outcomes (aHR 1.45, 95% CI 0.95-2.22, P=0.087). CONCLUSIONS: Relative to those receiving larger valves, patients receiving small bioprosthetic valves had poorer hemodynamic performance but did not demonstrate differences in clinical events in long-term follow-up.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Seguimentos , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Desenho de Prótese , Hemodinâmica
16.
BMC Cardiovasc Disord ; 24(1): 301, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872098

RESUMO

BACKGROUND: Studies of transcatheter pulmonary valve replacement (TPVR) with the Melody valve have demonstrated good clinical and hemodynamic outcomes. Our study analyzes the midterm clinical and hemodynamic outcomes for patients who underwent Melody valve implantation in Southeast Asia. METHODS: Patients with circumferential conduits or bioprosthetic valves and experiencing post-operative right ventricular outflow tract (RVOT) dysfunction were recruited for Melody TPVR. RESULTS: Our cohort (n = 14) was evenly divided between pediatric and adult patients. The median age was 19 years (8-38 years), a male-to-female ratio of 6:1 with a median follow-up period of 48 months (16-79 months), and the smallest patient was an 8-year-old boy weighing 18 kg. All TPVR procedures were uneventful and successful with no immediate mortality or conduit rupture. The primary implant indication was combined stenosis and regurgitation. The average conduit diameter was 21 ± 2.3 mm. Concomitant pre-stenting was done in 71.4% of the patients without Melody valve stent fractures (MSFs). Implanted valve size included 22-mm (64.3%), 20-mm (14.3%), and 18-mm (21.4%). After TPVR, the mean gradient across the RVOT was significantly reduced from 41 mmHg (10-48 mmHg) to 16 mmHg (6-35 mmHg) at discharge, p < 0.01. Late follow-up infective endocarditis (IE) was diagnosed in 2 patients (14.3%). Overall freedom from IE was 86% at 79 months follow-up. Three patients (21.4%) developed progressive RVOT gradients. CONCLUSION: For patients in Southeast Asia with RVOT dysfunction, Melody TPVR outcomes are similar to those reported for patients in the US in terms of hemodynamic and clinical improvements. A pre-stenting strategy was adopted and no MSFs were observed. Post-implantation residual stenosis and progressive stenosis of the RVOT require long term monitoring and reintervention. Lastly, IE remained a concern despite vigorous prevention and peri-procedural bacterial endocarditis prophylaxis.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Valva Pulmonar , Recuperação de Função Fisiológica , Humanos , Masculino , Criança , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Adolescente , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiopatologia , Valva Pulmonar/diagnóstico por imagem , Resultado do Tratamento , Adulto Jovem , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Fatores de Tempo , Adulto , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Bioprótese , Estenose da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Sudeste Asiático
17.
Heart Vessels ; 39(3): 252-265, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37843552

RESUMO

This study retrospectively evaluated the mid-term outcomes of surgical aortic valve replacement (SAVR) using a stented porcine aortic valve bioprosthesis (Mosaic; Medtronic Inc., Minneapolis, MN, USA) with concomitant mitral valve (MV) repair. From 1999 to 2014, 157 patients (median [interquartile range] age, 75 [70-79] years; 47% women) underwent SAVR with concomitant MV repair (SAVR + MV repair), and 1045 patients (median [interquartile range] age, 76 [70-80] years; 54% women) underwent SAVR only at 10 centers in Japan as part of the long-term multicenter Japan Mosaic valve (J-MOVE) study. The 5-year overall survival rate was 81.5% ± 4.1% in the SAVR + MV repair group and 85.1% ± 1.4% in the SAVR only group, and the 8-year overall survival rates were 75.2% ± 5.7% and 78.1% ± 2.1%, respectively. Cox proportional hazards analysis showed no significant difference in the survival rates between the two groups (hazard ratio, 0.87; 95% confidence interval, 0.54-1.40; P = 0.576). Among women with mild or moderate mitral regurgitation who were not receiving dialysis, those who underwent SAVR + MV repair, were aged > 75 years, and had a preoperative left ventricular ejection fraction of 30-75% tended to have a lower mortality risk. In conclusion, this subgroup analysis of the J-MOVE cohort showed relevant mid-term outcomes after SAVR + MV repair.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Feminino , Suínos , Animais , Idoso , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Volume Sistólico , Estudos Retrospectivos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda , Estenose da Valva Aórtica/cirurgia , Fatores de Risco
18.
Artif Organs ; 48(9): 977-987, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38651352

RESUMO

BACKGROUND: In vitro assessment is mandatory for artificial heart valve development. This study aims to investigate the effects of pulse duplicator features on valve responsiveness, conduct a sensitivity analysis across valve prosthesis types, and contribute on the development of versatile pulse duplicator systems able to perform reliable prosthetic aortic valve assessment under physiologic hemodynamic conditions. METHODS: A reference pulse duplicator was established based on literature. Further optimization process led to new designs that underwent a parametric study, also involving different aortic valve prostheses. These designs were evaluated on criteria such as mean pressure differential and pulse pressure (assessed from high-fidelity pressure measurements), valve opening and closing behavior, flow, and regurgitation. Finally, the resulting optimized setup was tested under five different hemodynamic settings simulating a range of physiologic and pathologic conditions. RESULTS: The results show that both, pulse duplicator design and valve type significantly influence aortic and ventricular pressure, flow, and valve kinematic response. The optimal design comprised key features such as a compliance chamber and restrictor for diastolic pressure maintenance and narrow pulse pressure. Additionally, an atrial reservoir was included to prevent atrial-aortic interference, and a bioprosthetic valve was used in mitral position to avoid delayed valve closing effects. CONCLUSION: This study showed that individual pulse duplicator features can have a significant effect on valve's responsiveness. The optimized versatile pulse duplicator replicated physiologic and pathologic aortic valve hemodynamic conditions, serving as a reliable characterization tool for assessing and optimizing aortic valve performance.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Humanos , Valva Aórtica/cirurgia , Modelos Cardiovasculares , Bioprótese
19.
Ann Vasc Surg ; 105: 177-188, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38599483

RESUMO

BACKGROUND: The use of biological grafts provides acceptable mid- and long-term results in native or prosthetic vascular infections. Several reports describe the successful use of bovine pericardium in case of vascular infections, mainly as a large patch to be sutured as a tubular graft. Recently, a novel prefabricated bovine pericardium graft (Biointegral Surgical No-React® Inc, Mississauga, ON, Canada) has been introduced in clinical practice with promising results. In this study, we report our preliminary experience utilizing Biointegral Surgical graft in case of native and or prosthetic aorto-iliac and infrainguinal infection. METHODS: We retrospectively analyzed data from 20 patients with native or prosthetic aorto-iliac and infrainguinal infection who underwent in situ reconstruction (ISR) with a Biointegral Surgical No-React bovine pericardium prosthesis between October 2020 and February 2023 at the Vascular Surgery Unit of the Fondazione Policlinico Universitario Gemelli - IRCCS in Rome, Italy. All patients followed a standardized protocol including postoperative anticoagulation and long-term intravenous antibiotics. RESULTS: The indication for surgery was: mycotic aortic aneurysm in 4 patients (20%), graft infection after abdominal aortic repair in 11 patients (55%), peripheral graft infection in 5 patients (25%). Complete excision of the infected aorta or prosthetic graft, surgical debridement and ISR were performed in all patients. Hospital mortality rate was 5% (n = 1) and graft-related mortality of 0%. During follow-up (median 13 months, range 6-34 months), reinfection was 5.2% and primary graft patency 94.7%. CONCLUSIONS: The use of prefabricated bovine pericardial grafts represents a promising option for the treatment of native and prosthetic aorto-iliac and infrainguinal infections. The application of this biological graft with a standardized postoperative protocol has been associated with a satisfactory patency and reinfection rate without increased bleeding complications.


Assuntos
Bioprótese , Implante de Prótese Vascular , Prótese Vascular , Pericárdio , Desenho de Prótese , Infecções Relacionadas à Prótese , Humanos , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/mortalidade , Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Pericárdio/transplante , Masculino , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Idoso , Resultado do Tratamento , Feminino , Pessoa de Meia-Idade , Animais , Bovinos , Fatores de Tempo , Xenoenxertos , Idoso de 80 Anos ou mais , Artéria Ilíaca/cirurgia , Antibacterianos/administração & dosagem , Fatores de Risco , Grau de Desobstrução Vascular , Aneurisma Infectado/cirurgia , Aneurisma Infectado/microbiologia , Aneurisma Infectado/mortalidade , Aneurisma Infectado/diagnóstico por imagem , Reoperação
20.
Ann Vasc Surg ; 102: 181-191, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38307226

RESUMO

BACKGROUND: Infected aortic grafts and mycotic aneurysms represent one of the most complex challenges faced by vascular surgeons. Treatment has progressed from extra-anatomical bypass to in situ reconstruction. Additionally, bovine pericardium reconstruction (BPR) has increased, due to accessibility and reduced lower limb morbidity. There remains, however, limited evidence for its use. The aim is to pool all known data to understand outcomes following BPR of mycotic aneurysms or infected vascular grafts. METHODS: A systematic review was conducted in November 2021 with subsequent computerized meta-analysis of the pooled results and a final search in March 2022. Three databases, Excerpta Medica dataBASE (EMBASE), Cumulative Index of Nursing and Allied Health Literature (CINAHL), and National Institutes of Health PubMed (PubMed), were searched for the search term "(bovine OR xenoprosthetic) AND (aneurysm)", according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. RESULTS: From 9 studies, there were 133 patients: 67% graft infections and 33% mycotic aneurysms. Fifty-seven percent of reconstructions were in the abdominal aorta and 33% were in the thoracic aorta. One hundred fifty-eight pathogens were identified, including Staphylococcus aureus (23%), Candida albicans (13%), and Escherichia coli (13%). In 12%, no microorganisms were identified. Thirty-day mortality was 19.14% (CI 10.83-28.71), late mortality was 19.08% (confidence interval [CI] 7.76-32.83), and overall mortality was 40.20% (CI 29.82-50.97). One patient died intraoperatively. There were a total of 151 in-hospital complications after 30 days postoperation. Common complications were acute renal failure (17%), pneumonia (14%), delirium (12%), respiratory insufficiency (11%) and renal insufficiency (7%). Lower limb ischemia was low, occurring in 5.66% (CI 0.54-13.82) of patients. Loss of graft patency leading to reintervention occurred in 1.20% (CI 0.00-7.71) of the grafts. Reinfection rate was 0.00% (CI 0.00-1.21). CONCLUSIONS: This meta-analysis highlights low reinfection and high graft patency using BPR with medium-length follow-up; however, there remain limited long-term and comparative data regarding options for aortic reconstruction. As expected in this complex cohort, the complication rate and 30-day mortality remain high.


Assuntos
Aneurisma Infectado , Bioprótese , Implante de Prótese Vascular , Prótese Vascular , Xenoenxertos , Pericárdio , Infecções Relacionadas à Prótese , Aneurisma Infectado/cirurgia , Aneurisma Infectado/microbiologia , Aneurisma Infectado/mortalidade , Aneurisma Infectado/diagnóstico por imagem , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Animais , Pericárdio/transplante , Resultado do Tratamento , Bovinos , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Fatores de Risco , Masculino , Feminino , Fatores de Tempo , Idoso , Pessoa de Meia-Idade , Aneurisma Aórtico/cirurgia , Aneurisma Aórtico/microbiologia , Aneurisma Aórtico/mortalidade , Aneurisma Aórtico/diagnóstico por imagem , Medição de Risco , Idoso de 80 Anos ou mais
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa