Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 391
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
Support Care Cancer ; 28(1): 239-247, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31020438

RESUMO

OBJECTIVES: To evaluate the in vitro effects of radiotherapy (RT) on the morphological surface of the enamel and dentin and to determine the best adhesive system and most appropriate time to restore teeth in head and neck cancer patients. METHODS: Sixty third molars were cut into 120 enamel fragments and 120 dentin fragments and divided into four groups (n = 30): G1 (control): nonirradiated, only restorative procedure; G2: restorative procedure immediately before RT; G3: restorative procedure immediately after RT; and G4: restorative procedure 6 months after RT. Each group was divided into two subgroups: Adper™ Single Bond 2 (SB) and Clearfill SE Bond (CL) based on the material used. After RT and restorative procedures, the specimens were subjected to confocal microscopy and shear bond strength test. Data were analyzed using a two-way ANOVA followed by Tukey's test at a significance level of 5%. RESULTS: Morphological changes were observed in both substrates after a cumulative dose of 40 Gy, and after 60 Gy, the changes were more evident in both substrates. CL had the highest strength values in both substrates (p < 0.05), and G2 had the lowest strength values for the enamel and dentin (p < 0.05). CONCLUSIONS: Based on the in vitro study results, we can conclude that RT substantially changes the morphological surface of enamel and dentin and impairs the bond strength. The Clearfill system yielded better results than Adper Single Bond 2, and restoring teeth before RT resulted in the worst results in both substrates.


Assuntos
Adesivos/efeitos da radiação , Esmalte Dentário/efeitos da radiação , Adesivos Dentinários/efeitos da radiação , Dentina/efeitos da radiação , Neoplasias de Cabeça e Pescoço/radioterapia , Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Resinas Compostas/efeitos da radiação , Colagem Dentária , Dentição Permanente , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Teste de Materiais , Dente Molar/efeitos da radiação , Doses de Radiação , Distribuição Aleatória , Cimentos de Resina/efeitos da radiação , Resistência ao Cisalhamento/efeitos da radiação , Fraturas dos Dentes/etiologia , Fraturas dos Dentes/patologia
2.
J Prosthodont ; 28(1): e290-e296, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29380483

RESUMO

PURPOSE: To evaluate the influence of laser-activated irrigation by Er:YAG and Er:YSGG (LAI) protocols and Nd:YAG laser irradiation on the bond strength of self-adhesively cemented fiber posts to root canal dentine. MATERIALS AND METHODS: The study sample consisted of 84 human single-rooted permanent teeth instrumented with ProTaper Next technique. After obturation, post space preparations were created for fiber-reinforced composite posts. The prepared specimens were divided according to the laser treatment of the post space preparations: group 1: LAI (Er:YAG) + saline solution (pulse energy: 20 mJ, repetition rate: 15 Hz); group 2: LAI (Er:YAG) + QMiX solution (pulse energy: 20 mJ, repetition rate: 15 Hz); group 3: LAI (Er,Cr:YSGG) + saline solution (pulse energy: 62.5 mJ, 20 Hz); group 4: LAI (Er,Cr:YSGG) + QMiX (pulse energy: 62.5 mJ, 20 Hz); Nd:YAG laser (pulse energy: 100 mJ, 10 Hz). Fiber-reinforced posts were cemented with a self-adhesive cement. The bond strength was evaluated by the push-out bond strength test, and the mode of failure was determined under a stereomicroscope. Kruskal-Wallis test was used for the intergroup comparative analysis with 5% level of significance. RESULTS: The highest bond strength was recorded in the Er:YAG + QMiX group (mean 3.401 MPa) (p < 0.05), followed by the Er,Cr:YSGG and the Er:YAG + saline solution (mean 1.111 MPa and 1.094 MPa, respectively), which did not differ significantly (p = 0.232). The irradiation with the Nd:YAG laser caused similar bond strength as the Er,Cr:YSGG + QMiX (p = 0.942). CONCLUSION: All laser protocols enhanced the bond strength of the self-adhesive cement in root canals compared to only saline irrigation. The bond strength of the self-adhesive cement depended on the laser parameters and irrigant used for the LAI.


Assuntos
Lasers de Estado Sólido , Técnica para Retentor Intrarradicular , Cimentos de Resina/efeitos da radiação , Autocura de Resinas Dentárias/métodos , Humanos , Cimentos de Resina/uso terapêutico , Dente não Vital
3.
J Prosthodont ; 28(1): e181-e185, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28257161

RESUMO

PURPOSE: In clinical prosthetics procedures, including endodontics and post fixation, the presence of a smear layer can reduce the post bond strength. An Er,Cr:YSGG laser, which emits at 2780 nm, can promote a smear-layer-free surface due to the ablation process. Considering these aspects, the purpose of this work was to evaluate the influence of Er,Cr:YSGG laser irradiation using either a radial or an axial fiber tip on the bond strength of three resin cements to the fiber-reinforced composite posts. MATERIALS AND METHODS: Ninety recently extracted single rooted human teeth had their root canal instrumented and were randomly distributed into nine experimental groups, in which three resin cements (total-etching Variolink II, self-etching Panavia F, and self-adhesive RelyX Unicem Aplicap) and three root canal treatments (no treatment, laser irradiation using the radial fiber tip, laser irradiation using the axial fiber tip) were used. Specimens were then sectioned into three sections (cervical, middle, and apical thirds) with two slices on each section. A push-out test was performed on each slice, and the values were recorded as MPa. The push-out data were analyzed by a Ryan-Joiner normality test followed by a two-way ANOVA test and Tukey pairwise comparison. The statistical analysis was performed on each third section separately, with a 5% significance level. RESULTS: Laser irradiation with axial fiber tip significantly increased the post bond strength of RelyX Unicem Aplicap on middle third of specimens (p < 0.001) when compared to other root canal treatments (unlased or irradiated with radial tip). Considering the Panavia resin cement, laser irradiation with either axial or radial tips promoted a significant increase on the post bond strength of middle third when compared to unlased specimens (p < 0.001); however, laser irradiation did not influence the post bond strength of Variolink resin cement. CONCLUSIONS: The use of the Er,Cr:YSGG laser for clinical prosthetics procedures enhances the post bond strength of Panavia and RelyX Unicem Aplicap resin cements, mainly at middle third of roots, and does not interfere with the bond strength of Variolink resin cement. For the RelyX Unicem Aplicap system, the use of axial tip is most advantageous and can be recommended for future clinical application.


Assuntos
Colagem Dentária/métodos , Lasers de Estado Sólido/uso terapêutico , Cimentos de Resina/química , Cimentos de Resina/efeitos da radiação , Tratamento do Canal Radicular/instrumentação , Tratamento do Canal Radicular/métodos , Raiz Dentária/efeitos da radiação , Corrosão Dentária/métodos , Cavidade Pulpar/efeitos da radiação , Análise do Estresse Dentário , Vidro , Humanos , Teste de Materiais , Técnica para Retentor Intrarradicular/instrumentação , Doses de Radiação , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Autocura de Resinas Dentárias , Estresse Mecânico
4.
Int Endod J ; 51(11): 1301-1312, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29729026

RESUMO

AIM: To evaluate the bond strength and adhesive interface between several resin cements and root dentine immediately and 6 months after radiotherapy. METHODOLOGY: Sixty maxillary canines were selected and randomly assigned to two groups (n = 30): one group was not irradiated and the other one was subjected to a cumulative radiation dose of 60 Gy. The teeth were sectioned to obtain roots 16 mm long and the canals were prepared with the Reciproc system (R50) and filled using a lateral condensation technique with an epoxy resin sealer. Each group was divided into three subgroups (n = 10) according to the resin cement used for fibreglass fibre post cementation: RelyX-U200, Panavia-F2.0 and RelyX ARC. The posts were cemented in accordance with the manufacturer's recommendations. Three 1-mm-thick dentine slices were then obtained from each root third. The first two slices in the crown-apex direction of each third were selected for the push-out test. The failure mode after debonding was determined with a stereo microscope. The third slice from each root third was selected for scanning electron microscopy (SEM) analyses to examine the resin cement-dentine interface with 100, 1000, 2000 and 4000× magnification. Bond strength data were analysed by anova and Tukey's test (α = 0.05). RESULTS: Significantly lower bond strength (P < 0.0001) was obtained after irradiation compared to nonirradiated teeth. RelyX-U200 cemented fibre posts had the higher bond strength (15.17 ± 5.89) compared with RelyX ARC (P < 0.001) and Panavia-F2.0 (P < 0.001). The evaluation after 6 months revealed lower bond strength values compared to the immediate values (P < 0.001) for irradiated and nonirradiated teeth. Cohesive failures occurred in the irradiated dentine. SEM revealed fractures, microfractures and fewer collagen fibres in irradiated root dentine. RelyX-U200 and Panavia-F2.0 were associated with a juxtaposed interface of the cement with the radicular dentine in irradiated and nonirradiated teeth, and for RelyX ARC, hybrid layer formation and tags were observed in both irradiated and nonirradiated teeth. CONCLUSION: Radiation was associated with a decrease in the push-out bond strength and with lower resin cement/root dentine interface adaptation. Self-adhesive resin cement was a better alternative for fibre post cementation in teeth subjected to radiation therapy. The bond strength decreased after 6 months.


Assuntos
Colagem Dentária , Dentina/efeitos dos fármacos , Radioterapia/métodos , Cimentos de Resina/química , Cimentos de Resina/efeitos da radiação , Raiz Dentária/efeitos dos fármacos , Bis-Fenol A-Glicidil Metacrilato/química , Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Cimentação/métodos , Cimentos Dentários/química , Cimentos Dentários/efeitos da radiação , Materiais Dentários/química , Materiais Dentários/efeitos da radiação , Análise do Estresse Dentário , Resinas Epóxi/química , Resinas Epóxi/efeitos da radiação , Vidro , Cimentos de Ionômeros de Vidro/química , Cimentos de Ionômeros de Vidro/efeitos da radiação , Humanos , Teste de Materiais , Polietilenoglicóis/química , Polietilenoglicóis/efeitos da radiação , Ácidos Polimetacrílicos/química , Ácidos Polimetacrílicos/efeitos da radiação , Técnica para Retentor Intrarradicular , Materiais Restauradores do Canal Radicular/química , Materiais Restauradores do Canal Radicular/efeitos da radiação , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície
5.
J Prosthodont ; 27(5): 449-455, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27455118

RESUMO

PURPOSE: To evaluate the color change caused by post-irradiation conversion (ΔE24h and ΔE8 days ) and artificial aging (ΔEAGING ) of resin cements light activated through ceramics of different opacities immediately and 6 minutes after manipulating the material. MATERIALS AND METHODS: Resin cement disks (Allcem and LuxaCore) were light activated through ceramics (without ceramic, e.max HT, LT, and MO) immediately and 6 minutes after the manipulation (n = 10). Spectrophotometry was used to evaluate ΔE24h and ΔE8 days after 37˚C-dry-dark-storage for 24 hours and 8 days, and ΔEAGING after 60˚C-water-storage for 24 hours. Data were analyzed with three-way ANOVA and Tukey's HSD (α = 0.05). RESULTS: Regarding the post-irradiation color change, significant differences were found between the cements (p < 0.0001), light activation protocols (p = 0.037), and ceramics (p < 0.001). The immediate activation (16.2 ± 0.1) showed lower ΔE values than the delayed activation (16.5 ± 0.1). Ceramics influenced the ΔE values as follows: MO (14.0 ± 1.2) < LT (14.9 ± 1.2) ≈ HT (15.4 ± 1.2) < control (21.2 ± 1.2). Regarding ΔEAGING , significant differences were found between cements (p < 0.001), light activation (p = 0.006), and ceramics (p < 0.001). The delayed activation (8.4 ± 0.1) showed lower values than the immediate activation (8.9 ± 0.1). Ceramic spacers influenced ΔEAGING as follows: control (5.6 ± 0.2) < MO (6.6 ± 0.2) < HT (11.0 ± 0.2) ≈ LT (11.5 ± 0.2). CONCLUSION: The delayed light activation resulted in increased color stability, while the ceramic interposition resulted in lower color stability.


Assuntos
Cor , Cura Luminosa de Adesivos Dentários , Cimentos de Resina/efeitos da radiação , Óxido de Alumínio , Resinas Compostas , Porcelana Dentária , Teste de Materiais , Espectrofotometria , Propriedades de Superfície
6.
Lasers Med Sci ; 32(4): 779-785, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28280997

RESUMO

The purpose of this study is to determine the CO2 laser irradiation in comparison with sandblasting (Sb), hydrofluoric acid (Hf) and silane coupling agent (Si) on shear bond strength (SBS), roughness (Rg) and wettability (Wt) of resin cement to CAD/CAM ceramics. Sixty (CAD/CAM) ceramic discs were prepared and distributed into six different groups: group A, control lithium disilicate (Li); group B, control zirconia (Zr); group C, Li: CO2/HF/Si; group D, Li: HF/Si; group E, Zr: CO2/Sb/Si; group F, Zr: Sb/Si. Result showed significant difference between irradiated and non-irradiated in terms of shear bond strength for zirconia ceramics (p value = 0.014). Moreover, partial surface wettability for irradiated and non-irradiated ceramics. Irradiated surface demonstrated more rough surface in lithium disilicate than zirconia ceramics. CO2 irradiation could increase shear bond strength, surface roughness and wettability for both CAD/CAM ceramics.


Assuntos
Cerâmica/efeitos da radiação , Desenho Assistido por Computador , Lasers de Gás , Teste de Materiais , Microscopia de Força Atômica , Resistência ao Cisalhamento , Porcelana Dentária/efeitos da radiação , Ácido Fluorídrico/química , Cimentos de Resina/química , Cimentos de Resina/efeitos da radiação , Estresse Mecânico , Molhabilidade , Zircônio/efeitos da radiação
7.
Lasers Med Sci ; 32(5): 967-974, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28357598

RESUMO

The aim of this study was to evaluate the effect of Er:YAG laser irradiation on the micro-shear bond strength of self-etch adhesives to the superficial dentin and the deep dentin before and after thermocycling. Superficial dentin and deep dentin surfaces were prepared by flattening of the occlusal surfaces of extracted human third molars. The deep or superficial dentin specimens were randomized into three groups according to the following surface treatments: group I (control group), group II (Er:YAG laser; 1.2 W), and group III (Er:YAG laser; 0.5 W). Clearfil SE Bond or Clearfil S3 Bond was applied to each group's dentin surfaces. After construction of the composite blocks on the dentin surface, the micro-shear bond testing of each adhesive was performed at 24 h or after 15,000 thermal cycles. The data were analyzed using a univariate analysis of variance and Tukey's test (p < 0.05). Laser irradiation in superficial dentin did not significantly affect bond strength after thermocycling (p > 0.05). However, deep-dentin specimens irradiated with laser showed significantly higher bond strengths than did control specimens after thermocycling (p < 0.05). Thermocycling led to significant deterioration in the bond strengths of all deep-dentin groups. The stable bond strength after thermocycling was measured for all of the superficial-dentin groups. No significant difference was found between the 0.5 and 1.2 W output power settings. In conclusion, the effect of laser irradiation on the bond strength of self-etch adhesives may be altered by the dentin depth. Regardless of the applied surface treatment, deep dentin showed significant bond degradation.


Assuntos
Adesivos/efeitos da radiação , Colagem Dentária , Dentina/efeitos da radiação , Lasers de Estado Sólido , Resinas Compostas/química , Adesivos Dentinários/efeitos da radiação , Humanos , Cimentos de Resina/efeitos da radiação , Resistência à Tração
8.
J Adhes Dent ; 19(1): 39-48, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28195273

RESUMO

PURPOSE: To evaluate the light transmission characteristics of different types, shades, and thicknesses of novel CAD/CAM materials and their effect on the degree of conversion (DC) of a dual-curing resin cement. MATERIALS AND METHODS: Square specimens (12 × 12 mm2) of three CAD/CAM materials - GC Cerasmart, Lava Ultimate, Vita Enamic - of different thicknesses (1.00, 1.50, and 2.00 mm, n = 5 per thickness) were irradiated with an LED unit. The amount of transmitted light was quantified. Thereafter, the DC% of the dual-curing resin cement (RelyX Ultimate) was recorded after 15 min using Fourier transform infrared spectroscopy. Statistical analysis was performed using two-way ANOVA followed by the Tukey's HSD post-hoc test at a significance level of p < 0.05. Regression analysis was performed to investigate the correlation between the DC and radiant energy, and the DC and thickness. RESULTS: Although the type and shade of CAD/CAM material significantly affect transmitted light irradiation (p < 0.0001), degrees of conversion are similar when the CAD/CAM material or material shade were taken into consideration (p > 0.05). Conversely, material thickness significantly affected light transmission (p < 0.0001) and DC (p < 0.0001). Multiple effects of material, shade, and thickness did not significantly affect the evaluated parameters (p = 0.638 for light irradiation; p = 0.637 for DC). Linear regression analysis showed a correlation between delivered energy and DC% results of the Vita Enamic (R²â€¯= 0.4169, p < 0.0001). CONCLUSION: Reduced light transmission in 2-mm-thick specimens of all CAD/CAM materials indicates that proper curing of the cement beneath CAD/CAM materials should be ensured.


Assuntos
Desenho Assistido por Computador , Luz , Cimentos de Resina/efeitos da radiação , Teste de Materiais
9.
Lasers Surg Med ; 48(1): 36-44, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26743446

RESUMO

BACKGROUND AND OBJECTIVE: The aim of this study was to evaluate the influence of cyclic loading on the shear bond strength (SBS) of a self-adhesive resin cement to zirconia surfaces after femtosecond laser irradiation at different steps and several conventional surface treatments. MATERIALS AND METHODS: One hundred fifty square-shaped zirconia samples were divided into five groups according their surface treatment: NT Group-no surface treatment; APA25 Group-airborne abrasion with 25 µm alumina particles; TSC Group-tribochemical silica coating; FS20 Group-femtosecond laser irradiation (800 nm, 4 mJ, 40 fs/pulse, 1 kHz, step 20); and FS40 Group-femtosecond laser irradiation (same parameters except step 40). Self-adhesive resin cement cylinders were bonded at the centre of the zirconia surface. For each experimental group, half of the specimens were subject to cyclic loading under 90 N (50.000 cycles, 3 cycles/sec) and the rest of the specimens were stored in distilled water at 37°C. All subgroups were tested for SBS with a universal testing machine at a crosshead speed of 0.5 mm/min, until fracture. The results were analyzed statistically. RESULTS: When cyclic loading was applied, all surface treatments had lower SBS values, except APA25. The four surface treatments had the same SBS values when cyclic loading was employed. CONCLUSIONS: Use of femtosecond laser irradiation could be an alternative to conventional surface treatments to achieve suitable adhesion zirconia and resin cements. Femtosecond laser irradiation at step 40 is preferable because it is more efficient and faster.


Assuntos
Lasers , Cimentos de Resina/efeitos da radiação , Resistência ao Cisalhamento/efeitos da radiação , Zircônio/efeitos da radiação , Teste de Materiais
10.
J Adhes Dent ; 18(2): 151-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27022644

RESUMO

PURPOSE: To evaluate the effects of three different radiation doses on the bond strengths of two different adhesive systems to enamel and dentin. MATERIALS AND METHODS: Eighty human third molars were randomly divided into four groups (n = 20) according to the radiation dose (control/no radiation, 20 Gy, 40 Gy, and 70 Gy). The teeth were sagittally sectioned into three slices: one mesial and one distal section containing enamel and one middle section containing dentin. The sections were then placed in the enamel and dentin groups, which were further divided into two subgroups (n = 10) according to the adhesive used. Three restorations were performed in each tooth (one per section) using Adper Single Bond 2 (3M ESPE) or Universal Single Bond (3M ESPE) adhesive system and Filtek Z350 XT (3M ESPE) resin composite and subjected to the microshear bond test. Data were analyzed using a two-way ANOVA followed by Tukey's test. Failure modes were examined under a stereoscopic loupe. RESULTS: Radiotherapy did not affect the bond strengths of the adhesives to either enamel or dentin. In dentin, the Universal Single Bond adhesive system showed higher bond strength values when compared with the Adper Single Bond adhesive system. More adhesive failures were observed in the enamel for all radiation doses and adhesives. CONCLUSION: Radiotherapy did not influence the bond strength to enamel or dentin, irrespective of the adhesive or radiation dose used.


Assuntos
Colagem Dentária , Esmalte Dentário/efeitos da radiação , Dentina/efeitos da radiação , Doses de Radiação , Cimentos de Resina/efeitos da radiação , Condicionamento Ácido do Dente/métodos , Adesividade , Bis-Fenol A-Glicidil Metacrilato/química , Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Resinas Compostas/química , Resinas Compostas/efeitos da radiação , Lâmpadas de Polimerização Dentária/classificação , Cimentos Dentários/química , Cimentos Dentários/efeitos da radiação , Análise do Estresse Dentário/instrumentação , Humanos , Ácidos Fosfóricos/química , Distribuição Aleatória , Cimentos de Resina/química , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo
11.
J Adhes Dent ; 18(2): 161-71, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27022645

RESUMO

PURPOSE: To assess the light irradiance (LI) delivered by two light-curing units and to measure the degree of conversion (DC) of three composite cements and one flowable composite when cured through zirconia or ceramic-veneered zirconia plates with different thicknesses. MATERIALS AND METHODS: Three dual-curing composite cements (Clearfil Esthetic Cement, Panavia F2.0, G-CEM LinkAce) and one light-curing flowable composite (G-aenial Universal Flo) were investigated. Nine different kinds of zirconia plates were prepared from three zirconia grades (YSZ: Aadva and KATANA; Ce-TZP/Al2O3: NANOZR) in three different thicknesses (0.5- and 1.5-mm-thick zirconia, and 0.5-mm-thick zirconia veneered with a 1.0-mm-thick veneering ceramic). Portions of the mixed composite cements and the flowable composite were placed on a light spectrometer to measure LI while being light cured through the zirconia plates for 40 s using two light-curing units (n = 5). After light curing, micro-Raman spectra of the composite films were acquired to determine DC at 5 and 10 min, 1 and 24 h, and at 1 week. RESULTS: The zirconia grade and the thickness of the zirconia/veneered zirconia plates significantly decreased LI. Increased LI did not increase DC. Only the Ce-TZP/Al2O3 (NANOZR) zirconia was too opaque to allow sufficient light transmission and resulted in significantly lower DC. CONCLUSION: Although zirconia-based restorations attenuate the LI of light-curing units, the composite cements and the flowable composite could be light cured through the YSZ zirconia. LI is too low through Ce-TZP/Al2O3 zirconia, necessitating the use of self-/dual-curing composite cements.


Assuntos
Resinas Compostas/efeitos da radiação , Materiais Dentários/efeitos da radiação , Luz , Cimentos de Resina/efeitos da radiação , Zircônio/química , Óxido de Alumínio/química , Cerâmica/química , Cerâmica/efeitos da radiação , Cério/química , Resinas Compostas/química , Lâmpadas de Polimerização Dentária/classificação , Materiais Dentários/química , Facetas Dentárias , Humanos , Cura Luminosa de Adesivos Dentários/instrumentação , Teste de Materiais , Metacrilatos/química , Microespectrofotometria , Polietilenoglicóis/química , Polimerização , Ácidos Polimetacrílicos/química , Poliuretanos/química , Doses de Radiação , Cimentos de Resina/química , Espalhamento de Radiação , Análise Espectral Raman , Propriedades de Superfície , Ítrio/química
12.
Int J Paediatr Dent ; 26(5): 376-82, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26548449

RESUMO

OBJECTIVE: To assess the effects of different modes of a third-generation light-curing unit (LCU) (VALO) on the microhardness of restorative materials. DESIGN: A microhybrid composite resin (Filtek(™) Z550), a giomer (Beautifil II), a compomer (Dyract eXtra) and a RMGIC (Photac(™) Fil) were used in the study. Three different modes of VALO were tested and a second-generation LCU (Elipar S10) was used as a control. The microhardness (VHN) was measured using a Vickers Hardness tester. Data were analyzed using two-way anova and post hoc Tukey's test (P < 0.05). RESULTS: The Filtek Z550 group had the highest VHN values followed by Photac Fil, Beautifil II and the Dyract eXtra at both top and bottom surfaces, however the difference between Filtek Z550 and Photac Fil was not statistically significant for the bottom surfaces (P > 0.05). Of the different curing protocols tested, the VALO LCU in Mode 3 resulted in the lowest VHN values at both top and bottom surfaces (P < 0.05). CONCLUSION: Based on the results of this study, it can be concluded that the high-power mode of the VALO LCU can be recommended for clinical applications especially in pediatric patients, as it can shorten the time required to adequately polymerize resin-based tooth-colored restorative materials.


Assuntos
Resinas Compostas/química , Resinas Compostas/efeitos da radiação , Lâmpadas de Polimerização Dentária/classificação , Materiais Dentários/química , Iluminação/instrumentação , Teste de Materiais , Bis-Fenol A-Glicidil Metacrilato/química , Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Compômeros/química , Compômeros/efeitos da radiação , Materiais Dentários/efeitos da radiação , Restauração Dentária Permanente , Desenho de Equipamento , Cimentos de Ionômeros de Vidro/química , Cimentos de Ionômeros de Vidro/efeitos da radiação , Dureza/efeitos da radiação , Cimentos de Resina/química , Cimentos de Resina/efeitos da radiação , Resinas Sintéticas/química , Resinas Sintéticas/efeitos da radiação , Propriedades de Superfície , Fatores de Tempo
13.
Lasers Med Sci ; 30(8): 2123-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25958172

RESUMO

Yttrium-stabilized tetragonal zirconia polycrystalline (Y-TZP) ceramic is widely used as an all-ceramic core material because of its enhanced mechanical and aesthetic properties. The bond strength of Y-TZP restorations affects long-term success; hence, surface treatment is required on ceramic boundaries. This study evaluated the effect of different laser beam angles on Y-TZP-resin cement shear bond strength (SBS). Forty plates of Y-TZP ceramics were randomly assigned to four groups (n = 10). A femtosecond amplifier laser pulse was applied on Y-TZP surface with different incidence angles (90°, 75°, 60°, 45°). The resin cement was adhered onto the zirconia surfaces. The SBS of each sample was measured using universal testing machine at crosshead speed of 1 mm/min. The SBS was analyzed through one-way analysis of variance (ANOVA)/Tukey tests. The results showed that the degree of laser beam angle affects the SBS of resin cement to Y-TZP. The laser beam was applied to a surface with a 45° angle which resulted in significantly higher SBS (18.2 ± 1.43 MPa) than other groups (at 90° angulation (10.79 ± 1.8 MPa), at 75° (13.48 ± 1.2 MPa) and at 60° (15.85 ± 0.81 MPa); p < 0.001). This study shows that decreasing of the angle between the ceramic surface and the laser beam increased the SBS between the resin cement and the ceramic material, as well as the orifice.


Assuntos
Colagem Dentária , Cimentos Dentários/efeitos da radiação , Lasers , Teste de Materiais , Cimentos de Resina/efeitos da radiação , Zircônio/efeitos da radiação , Microscopia Eletrônica de Varredura , Resistência ao Cisalhamento , Fatores de Tempo , Ítrio/química
14.
J Adhes Dent ; 17(2): 181-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25893225

RESUMO

PURPOSE: To evaluate the effect of different radiant exposure values delivered to two simplified etch-and-rinse adhesive systems on push-out bond strength (PBS) of fiber posts to root canal, as well as nanoleakage (NL) and in situ degree of conversion (DC) within the hybrid layer. MATERIALS AND METHODS: The roots of human premolars were endodontically prepared and divided into 6 groups according to the combination of the main factors adhesive/resin cement (2 commercial brands) and radiant exposure (4, 16, 48, and 288 J/cm2). The posts were cemented and the PBS tested at 0.5 mm/min (n = 7). The NL (n = 3) was evaluated using SEM after immersion of specimens in 50% silver nitrate. Micro-Raman spectroscopy was performed to determine the in situ DC (n = 2). Data were analyzed by three-way repeated measures ANOVA and Tukey's post-hoc test (5%). RESULTS: PBS (MPa) showed a significant difference only for the middle third when an increase in radiant exposure from 4 to 16 J/cm2 or higher was used (p < 0.05). The NL (%) decreased significantly with increasing radiant exposure from 48 to 288 J/cm2 in the middle and apical thirds when compared to lower radiant exposure (p < 0.05). The radiant exposure of 288 J/cm2 significantly increased the DC (%) in the middle and apical thirds, compared the other radiant exposure values (p < 0.05). CONCLUSION: The increase in radiant exposure delivered to the cervical third of root canals during post cementation improved the adhesive performance of simplified etch-and-rinse adhesive systems in the apical and middle thirds.


Assuntos
Cavidade Pulpar/ultraestrutura , Cura Luminosa de Adesivos Dentários/métodos , Técnica para Retentor Intrarradicular/instrumentação , Doses de Radiação , Cimentos de Resina/efeitos da radiação , Dente Pré-Molar/ultraestrutura , Bis-Fenol A-Glicidil Metacrilato/química , Cimentação/métodos , Infiltração Dentária/classificação , Humanos , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Polietilenoglicóis/química , Polimerização , Ácidos Polimetacrílicos/química , Poliuretanos/química , Cimentos de Resina/química , Coloração pela Prata , Análise Espectral Raman , Estresse Mecânico , Propriedades de Superfície , Ápice Dentário/ultraestrutura
15.
J Adhes Dent ; 17(3): 243-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26114163

RESUMO

PURPOSE: To evaluate the hardness of a dual-curing self-adhesive resin cement (RelyX U200) and a conventional dual-curing resin cement (RelyX ARC) cured with different light curing units of different wavelengths (Elipar Freelight 2 LED [430 to 480 nm, conventional], Bluephase LED [380 to 515 nm, polywave], AccuCure 3000 Laser [488 nm]) by means of the nanoindentation test. MATERIALS AND METHODS: Bovine incisors were cleaned and then sectioned at the cementoenamel junction to remove the crown. After embedding in acrylic, dentin surfaces of the specimens were exposed and ground flat to standardize the surfaces. To simulate clinically placing indirect restorations, ceramic (IPS e.maxPress/Ivoclar Vivadent) or indirect composite resin (SR Adoro/Ivoclar Vivadent) slabs were cemented on dentin surfaces. The specimens were sectioned longitudinally at low speed under constant irrigation and then polished. In the positive control group, the cement was light cured without the interposition of indirect restorative material; in the negative control group, after the indirect restorative material was cemented, no light curing was performed, allowing only chemical polymerization of the cement. All specimens were stored in distilled water at 37°C for 7 days. Nanoindentadion hardness of the cement layer was measured under a 100-mN load. Data were statistically analyzed using ANOVA and Tukey's test (p < 0.05). RESULTS: Although the self-adhesive cement is technically simple, conventional cement showed the best polymerization performance. The polywave LED technology did not differ significantly from other light-curing units. The hardness of the resin cements evaluated was negatively influenced by the interposition of an indirect restorative material; only the LEDs were able to maintain the same degree of cement polymerization when an indirect restorative material was used. CONCLUSION: The photoactivation step is required during the cementation of indirect restorations to ensure adequate polymerization of dual-curing resin cements.


Assuntos
Lâmpadas de Polimerização Dentária/classificação , Materiais Dentários/química , Cimentos de Resina/química , Animais , Bis-Fenol A-Glicidil Metacrilato/química , Bovinos , Resinas Compostas/química , Cimentos Dentários/química , Porcelana Dentária/química , Análise do Estresse Dentário/instrumentação , Dentina/ultraestrutura , Dureza , Cura Luminosa de Adesivos Dentários/métodos , Teste de Materiais , Polietilenoglicóis/química , Polimerização , Ácidos Polimetacrílicos/química , Cimentos de Resina/efeitos da radiação , Temperatura , Fatores de Tempo , Água/química
16.
J Prosthet Dent ; 114(1): 103-8, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25882969

RESUMO

STATEMENT OF PROBLEM: Monolithic zirconia restorations are increasingly common. Dual-polymerizing cements have been advocated for cementation. The opacious nature of zirconia restoration can attenuate light, compromising optimal resin polymerization and eventually restoration debonding. PURPOSE: The purpose of this in vitro study was to evaluate the influence of material thickness on light irradiance, radiant exposure, and the degree of monomer conversion (DC) of 2 dual-polymerizing resin cements light-polymerized through different brands of monolithic zirconia. MATERIAL AND METHODS: Dual-polymerizing resin cements (RelyX Ultimate; 3M-ESPE, and Variolink II; Ivoclar, Vivadent) were mixed according to the manufacturers' instructions with a film thickness of 40 µm, placed under a 10 × 10 mm specimen of monolithic zirconia (Prettau Anterior by Zirkonzahn, Katana by Noritake, BruxZir by Glidewell, and Zenostar by Wieland) and a zirconia core control (ICE zirkon by Zirkonzahn) at various thicknesses (0.50, 1.00, 1.50, and 2.00 mm, n = 5 of each thickness). Each specimen was irradiated for 20 seconds (RelyX Ultimate) and 40 seconds (Variolink II) with Elipar S10 (3M-ESPE, 1200 mW/cm(2)). The amount of irradiance and radiant exposure was quantified for each specimen. Fourier transform infrared spectroscopy was used to measure the DC from the bottom surface of the resin. Statistical analysis was performed with 2-way ANOVA and post hoc Tukey honest significant difference (HSD) tests (α = .05). RESULTS: Light irradiance and radiant exposure decreased as the thickness of the specimen increased (P < .05) regardless of the brand. The ranking from least to highest was BruxZir < ICE zircon = Wieland < Katana = Prettau Anterior. The zirconia brand, thickness, and cement type had a significant effect on the DC (P < .001). The DC decreased significantly as the thickness of the zirconia increased (P < .001). Katana and Prettau Anterior showed the highest DC and BruxZir showed the lowest. CONCLUSION: The thickness of zirconia affects the DC of resin-based cements. The DC of the resin cements differed significantly between cements and among zirconia brands. More polymerizing time may be needed to deliver sufficient energy through some brands of zirconia.


Assuntos
Cerâmica/química , Materiais Dentários/química , Cura Luminosa de Adesivos Dentários/métodos , Cimentos de Resina/química , Autocura de Resinas Dentárias/métodos , Ítrio/química , Zircônio/química , Humanos , Luz , Teste de Materiais , Polimerização , Doses de Radiação , Cimentos de Resina/efeitos da radiação , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Propriedades de Superfície , Fatores de Tempo
17.
J Prosthet Dent ; 113(2): 128-34, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25432362

RESUMO

STATEMENT OF PROBLEM: Understanding the effect of the degree of conversion on the mechanical properties of auto- and dual-polymerizing self-adhesive resin cements leads to a better estimation of their performance in different clinical scenarios. PURPOSE: The purpose of this study was to evaluate the effect of photopolymerization on the degree of conversion (DC) and polymerization kinetic of 4 dual-polymerized resin cements, 20 minutes after mixing, and its effects on the mechanical properties (biaxial flexural strength [FS] and modulus [FM]) after short-term aging. MATERIAL AND METHODS: Conventional (RelyX ARC and Clearfil Esthetic Cement) and self-adhesive resin cements (RelyX Unicem and Clearfil SA Cement) were applied to a Fourier infrared spectrometer to assess the DC (n=5) under the following 3 polymerization conditions: direct light exposure (dual-polymerizing mode), exposure through the prepolymerized disk, or autopolymerizing. The polymerization kinetic was recorded for 20 minutes. Then, disk-shaped specimens (n=11) were prepared to evaluate the effect of polymerization on the FS and FM in both extreme polymerization conditions (dual-polymerizing or autopolymerizing). Data were statistically analyzed by 2-way repeated measure ANOVA (DC) and by 2-way ANOVA (FS and FM), followed by the Tukey-Kramer post hoc test (α=.05). RESULTS: Autopolymerizing groups exhibited reduced DC means, whereas intermediate values were observed when resin cements were polymerized through the disk. All groups exhibited higher DC at the end of 20 minutes. The polymerization kinetic revealed a rising curve, and materials, when directly photopolymerized, reached a plateau immediately after light exposure. Regarding the flexural biaxial testing, most of the resin cements were affected by polymerization mode and differences among groups were product dependent. CONCLUSIONS: The resin cements achieved immediate higher DC and mechanical properties when photopolymerized. The total absence of photoactivation may still impair their mechanical properties even after short-term aging.


Assuntos
Cimentos de Resina/efeitos da radiação , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/química , Lâmpadas de Polimerização Dentária/classificação , Escuridão , Módulo de Elasticidade , Vidro/química , Humanos , Luz , Teste de Materiais , Maleabilidade , Polietilenoglicóis/química , Polimerização , Ácidos Polimetacrílicos/química , Doses de Radiação , Cimentos de Resina/química , Autocura de Resinas Dentárias/instrumentação , Autocura de Resinas Dentárias/métodos , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo
18.
Bull Tokyo Dent Coll ; 56(1): 33-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25765573

RESUMO

Atmospheric plasma or ultraviolet (UV) treatment alters the surface characteristics of tetragonal zirconia polycrystal (TZP), increasing its hydrophilicity by reducing the contact angle against water to zero. This suggests that such treatment would increase the wettability of bonding resin. The purpose of this study was to determine how increasing the hydrophilicity of TZP through plasma irradiation, UV treatment, or application of ceramic primer affected initial bonding with resin composites. Here, the effect of each pre-treatment on the hydrophilicity of TZP surfaces was determined by evaluating change in shear bond strength. Plasma irradiation, UV, or ceramic primer pre-treatment showed no significant effect on bonding strength between TZP surfaces and resin composites. In addition, alumina blasting yielded no significant increase in bond strength. Plasma irradiation, UV treatment, or ceramic primer pre-treatment did not lead to significant increase in bond strength between TZP and resin composites.


Assuntos
Cerâmica/química , Cimentos de Resina/química , Zircônio/química , Cerâmica/efeitos da radiação , Colagem Dentária , Radiação Eletromagnética , Interações Hidrofóbicas e Hidrofílicas , Cimentos de Resina/efeitos da radiação , Propriedades de Superfície , Raios Ultravioleta , Zircônio/efeitos da radiação
19.
Acta Odontol Scand ; 72(7): 543-8, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24490641

RESUMO

OBJECTIVE: The aim of this study was to evaluate the micromechanical properties of different adhesive bonding agents when polymerized through ceramics. MATERIALS AND METHODS: Sixty sound extracted human third molars were selected and the crowns were sectioned perpendicular to the long axis in order to obtain dentin slices to be bonded with one of the following adhesives: Syntac/Heliobond (Ivoclar-Vivadent) or Adper-Scotchbond-1XT (3M-ESPE). The adhesives were cured by using a LED-unit (Bluephase®, Ivoclar Vivadent) with three different curing times (10 s, 20 s and 30 s) under two ceramics (IPS-e.max-Press, Ivoclar-Vivadent; IPS-Empress®CAD, Ivoclar-Vivadent) of different thicknesses (0 mm, 0.75 mm, 2 mm). Thirty groups were included, each containing 60 measurements. Micromechanical properties (Hardness, HV; indentation modulus, E; and creep, Cr) of the adhesives were measured with an automatic microhardness indenter (Fisherscope H100C, Germany). Data were statistically analyzed by using one-way ANOVA and Tukey's post-hoc test, as well as a multivariate analysis to test the influence of the study parameters (SPSS 18.0). RESULTS: Significant differences were observed between the micromechanical properties of the adhesives (p < 0.05). The ceramic type showed the highest effect on HV (Partial-eta squared (η(2)) = 0.109) of the tested adhesives, while E (η(2) = 0.275) and Cr (η(2) = 0.194) were stronger influenced by the adhesive type. Ceramic thickness showed no effect on the E and Cr of the adhesives. CONCLUSIONS: The adhesive bonding agents used in this study performed well by curing through different thicknesses of ceramics. The micromechanical properties of the adhesives were determined by the adhesive type and were less influenced by ceramic type and curing time.


Assuntos
Cerâmica/química , Colagem Dentária , Adesivos Dentinários/química , Cura Luminosa de Adesivos Dentários/métodos , Acrilatos/química , Acrilatos/efeitos da radiação , Silicatos de Alumínio/química , Silicatos de Alumínio/efeitos da radiação , Cerâmica/efeitos da radiação , Lâmpadas de Polimerização Dentária , Porcelana Dentária/química , Porcelana Dentária/efeitos da radiação , Adesivos Dentinários/efeitos da radiação , Módulo de Elasticidade , Dureza , Humanos , Teste de Materiais , Polimerização , Cimentos de Resina/química , Cimentos de Resina/efeitos da radiação , Estresse Mecânico , Propriedades de Superfície , Fatores de Tempo
20.
BMC Oral Health ; 14: 48, 2014 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-24885810

RESUMO

BACKGROUND: Surface sealants have been successfully used in the prevention of erosive tooth wear. However, when multiple tooth surfaces should be sealed, the light-curing procedure is very time-consuming. Therefore, the aim of this study was to investigate whether reduced light-curing time (while maintaining similar energy density) has an influence on resin-based surface sealant cytotoxicity. METHODS: Bovine dentine discs were treated as follows: group 1: untreated, groups 2-5: Seal&Protect and groups 6-9: experimental sealer. Groups 2 and 6 were light-cured (VALO LED light-curing device) for 40 s (1000 mW/cm2), groups 3 and 7 for 10 s (1000 mW/cm2), groups 4 and 8 for 7 s (1400 mW/cm2) and groups 5 and 9 for 3 s (3200 mW/cm2). Later, materials were extracted in culture medium for 24 h, and released lactate dehydrogenase (LDH) activity as a measure of cytotoxicity was determined photometrically after cells (dental pulp cells and gingival fibroblasts) were exposed to the extracts for 24 h. Three independent experiments, for both sample preparation and cytotoxicity testing, were performed. RESULTS: Overall, lowest cytotoxicity was observed for the unsealed control group. No significant influence of light-curing settings on the cytotoxicity was observed (p = 0.537 and 0.838 for pulp cells and gingival fibroblasts, respectively). No significant difference in the cytotoxicity of the two sealants was observed after light-curing with same light-curing settings (group 2 vs. 6, 3 vs. 7, 4 vs. 8 and 5 vs. 9: p > 0.05, respectively). CONCLUSIONS: Shortening the light-curing time, while maintaining constant energy density, resulted in no higher cytotoxicity of the investigated sealants.


Assuntos
Materiais Dentários/toxicidade , Dentina/efeitos dos fármacos , Cura Luminosa de Adesivos Dentários/métodos , Selantes de Fossas e Fissuras/toxicidade , Cimentos de Resina/toxicidade , Animais , Bovinos , Técnicas de Cultura de Células , Células Cultivadas , Lâmpadas de Polimerização Dentária/classificação , Materiais Dentários/efeitos da radiação , Polpa Dentária/citologia , Polpa Dentária/efeitos dos fármacos , Fibroblastos/efeitos dos fármacos , Gengiva/citologia , Gengiva/efeitos dos fármacos , Humanos , L-Lactato Desidrogenase/análise , L-Lactato Desidrogenase/efeitos dos fármacos , Cura Luminosa de Adesivos Dentários/instrumentação , Metacrilatos/toxicidade , Selantes de Fossas e Fissuras/efeitos da radiação , Propilenoglicóis/toxicidade , Cimentos de Resina/efeitos da radiação , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa