Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.121
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 295-303, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37410179

RESUMO

PURPOSE: To describe the association of refraction development and axial length (AL) in young children and provide new insights into the progression of cylinder power. METHODS: Children (2-3 grades) were enrolled from primary schools in Shanghai and followed up for two years. Cycloplegic refraction, AL, and corneal curvature radius were measured. Refraction parameters were compared among groups with different AL, AL1 (AL < 23.5 mm), AL2 (23.5 mm ≤ AL < 24.5 mm), and AL3 (AL ≥ 24.5 mm). Multiple regression analysis was used to explore risk factors of diopter of cylinder (DC) progression. RESULTS: In total, out of 6891 enrolled children, 5961 participants (7-11 yrs) were included in the final analysis. Over the two-year period, the cylinder power significantly changed, and those with longer AL had more rapid DC progression over the two years (AL1, -0.09 ± 0.35 D; AL2, -0.15 ± 0.39 D; AL3, -0.29 ± 0.44 D) (P < 0.001). The change in DC was independently associated with AL at baseline (P < 0.001). The proportion of with-the-rule astigmatism increased from 91.3% to 92.1% in AL1 group, from 89.1% to 91.8% in AL2 group and from 87.1% to 92.0% in AL3 group. CONCLUSIONS: Young children with long AL experienced rapid progression of cylinder power. Both the control of myopia progression and attention to the correction of astigmatism are necessary in the health management of children with long AL. The significantly increased AL in participants might contribute to both the extent and direction of astigmatism.


Assuntos
Astigmatismo , Criança , Humanos , Pré-Escolar , Seguimentos , Progressão da Doença , China , Refração Ocular , Comprimento Axial do Olho
2.
Graefes Arch Clin Exp Ophthalmol ; 262(4): 1203-1213, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37930444

RESUMO

PURPOSE: To investigate the relationship between relative corneal refractive power shift (RCRPS) and axial length growth (ALG) in bilateral myopic anisometropes treated with orthokeratology. METHODS: A total of 102 children with myopic anisometropia in this prospective interventional study were randomly assigned to the spectacle group and orthokeratology group. Axial length (AL) and corneal topography was measured at baseline and the 12-month follow-up visit. ALG was defined as the difference between the two measurements, and RCRPS profiles were calculated from two axial maps obtained. RESULTS: In the orthokeratology group, the ALG in the more myopic eye (0.06 ± 0.15 mm) was significantly smaller than that in the less myopic eye (0.15 ± 0.15 mm, p < 0.001), and the interocular difference in AL significantly decreased following 1-year treatment, from 0.47 ± 0.32 to 0.38 ± 0.28 mm (p < 0.001). However, in the spectacle group, the ALG was similar between the two eyes, and the interocular difference in AL did not change significantly over one year (all p > 0.05). The interocular difference in ALG in the orthokeratology group was significantly correlated with the interocular difference in RCRPS (dRCRPS, ß=-0.003, p < 0.001) and the interocular difference in baseline AL (ß=-0.1179, p < 0.001), with R2 being 0.6197. CONCLUSION: Orthokeratology was effective in decreasing the magnitude of anisometropia. The interocular variation in RCRPS is an important factor accounting for the reduction of interocular ALG difference in anisomyopic children post-orthokeratology. These results provide insight into establishing eye-specific myopia control guidelines during orthokeratology treatment for myopic anisometropes.


Assuntos
Anisometropia , Miopia , Procedimentos Ortoceratológicos , Criança , Humanos , Anisometropia/terapia , Estudos Prospectivos , Refração Ocular , Comprimento Axial do Olho , Miopia/diagnóstico , Miopia/terapia , Topografia da Córnea
3.
Graefes Arch Clin Exp Ophthalmol ; 262(6): 1819-1828, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38446204

RESUMO

PURPOSE: The aim of this study is to investigate the distribution of spherical equivalent and axial length in the general population and to analyze the influence of education on spherical equivalent with a focus on ocular biometric parameters. METHODS: The Gutenberg Health Study is a population-based cohort study in Mainz, Germany. Participants underwent comprehensive ophthalmologic examinations as part of the 5-year follow-up examination in 2012-2017 including genotyping. The spherical equivalent and axial length distributions were modeled with gaussian mixture models. Regression analysis (on person-individual level) was performed to analyze associations between biometric parameters and educational factors. Mendelian randomization analysis explored the causal effect between spherical equivalent, axial length, and education. Additionally, effect mediation analysis examined the link between spherical equivalent and education. RESULTS: A total of 8532 study participants were included (median age: 57 years, 49% female). The distribution of spherical equivalent and axial length follows a bi-Gaussian function, partially explained by the length of education (i.e., < 11 years education vs. 11-20 years). Mendelian randomization indicated an effect of education on refractive error using a genetic risk score of education as an instrument variable (- 0.35 diopters per SD increase in the instrument, 95% CI, - 0.64-0.05, p = 0.02) and an effect of education on axial length (0.63 mm per SD increase in the instrument, 95% CI, 0.22-1.04, p = 0.003). Spherical equivalent, axial length and anterior chamber depth were associated with length of education in regression analyses. Mediation analysis revealed that the association between spherical equivalent and education is mainly driven (70%) by alteration in axial length. CONCLUSIONS: The distribution of axial length and spherical equivalent is represented by subgroups of the population (bi-Gaussian). This distribution can be partially explained by length of education. The impact of education on spherical equivalent is mainly driven by alteration in axial length.


Assuntos
Comprimento Axial do Olho , Escolaridade , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Alemanha/epidemiologia , Comprimento Axial do Olho/patologia , Distribuição Normal , Biometria/métodos , Refração Ocular/fisiologia , Seguimentos , Erros de Refração/fisiopatologia , Erros de Refração/diagnóstico , Erros de Refração/genética , Idoso , Adulto
4.
Graefes Arch Clin Exp Ophthalmol ; 262(7): 2309-2320, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38358526

RESUMO

PURPOSE: To compare the accuracy of the Barrett II universal (BU II) formula, Hoffer-Q, and SRKT formulae following lensectomy and IOL implantation in a large pediatric cohort. METHODS: Retrospective study of children who underwent lensectomy and IOL implantation between 2015 and 2023 at Hadassah-Hebrew University Medical Center, Jerusalem, Israel. RESULTS: One hundred and fifty-one eyes of 104 children aged 6.0 ± 3.9 years were included. The mean prediction error (PE) was - 0.08 ± 1.54 diopters (D) with BU II, 0.24 ± 1.46 D with Hoffer-Q, and 0.71 ± 1.92 D with SRKT (P = 0.10). In eyes with axial length (AL) < 22 mm, BU II and Hoffer-Q had a smaller PE than SRKT (P = 0.024). In eyes with AL ≥ 22 mm, BU II had a smaller PE than Hoffer-Q (P = 0.048). In children 24 months or older at surgery, BU II had a smaller PE than SRKT and Hoffer-Q (P = 0.012). However, in younger children, no difference was found between the formulae (P = 0.61). For mean k-values ≥ 44.5 D, BU II and Hoffer-Q had a smaller PE than SRKT (P = 0.002). An absolute prediction error < 1.0 D was obtained with BU II in 66% of eyes and SRKT in 35% (P = 0.01). CONCLUSIONS: The BU II formula performed well with a small prediction error. No significant difference in PE was detected overall between the formulae. However, only BU II demonstrated a stable prediction error at varying axial lengths, K-readings, and ages. As the biometric parameters of the developing eye change with growth, the BU II formula offers a reliable and stable option for pediatric IOL calculation.


Assuntos
Biometria , Implante de Lente Intraocular , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Masculino , Feminino , Criança , Pré-Escolar , Refração Ocular/fisiologia , Implante de Lente Intraocular/métodos , Biometria/métodos , Lentes Intraoculares , Erros de Refração/fisiopatologia , Erros de Refração/diagnóstico , Seguimentos , Lactente , Comprimento Axial do Olho/patologia , Adolescente , Reprodutibilidade dos Testes
5.
Retina ; 44(5): 923-927, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38109723

RESUMO

PURPOSE: To demonstrate through a diagnostic test used as a new preoperative assessment that trocar insertion for pars plana vitrectomy could be safely placed at a distance >4.0 mm in highly myopic eyes to facilitate the surgical maneuvers. METHODS: Thirty eyes of 30 patients were tested with a biometer for the axial length measurement and with ultrasound biomicroscopy to measure the pars plana length. Pars plana lengths of highly myopic eyes were then compared with those of emmetropic eyes. The surgeon also measured the pars plana of highly myopic eyes intraoperatively and compared it with ultrasound measurements to assess ultrasound biomicroscopy reliability. RESULTS: The mean axial length was 23.81 mm (SD ± 0.30) in the control group and 31.11 mm (SD ± 0.56) in the myopic group. The mean pars plana length was 4.96 mm (SD ± 0.19) in control eyes and 6.65 (SD ± 0.36) in myopic eyes. An extremely significant statistical difference ( P < 0.001) was obtained by comparing the length of pars plana between control eyes and myopic eyes. The results of pars plana measurements were 6.65 mm (SD ± 0.36, ultrasound biomicroscopy) and 6.66 mm (SD ± 0.34, intraoperative measurements) in myopic eyes. The statistical comparison of the measurements in these two groups did not give a statistically significant result ( P = 0.950). CONCLUSION: Ultrasound biomicroscopy is a reliable technique to calculate the length of pars plana in highly myopic eyes, where this parameter is significantly greater than that of emmetropic eyes. Trocars insertion for pars plana vitrectomy may be performed, in eyes with axial length >30 mm, in relative safety at a distance to limbus higher than 4 mm.


Assuntos
Comprimento Axial do Olho , Microscopia Acústica , Miopia Degenerativa , Vitrectomia , Humanos , Vitrectomia/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Comprimento Axial do Olho/diagnóstico por imagem , Comprimento Axial do Olho/patologia , Miopia Degenerativa/cirurgia , Idoso , Adulto , Instrumentos Cirúrgicos , Reprodutibilidade dos Testes , Biometria/métodos
6.
Retina ; 44(3): 527-536, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37972986

RESUMO

PURPOSE: To investigate fundus tessellation density (TD) and its association with axial length (AL) elongation and spherical equivalent (SE) progression in children. METHODS: The school-based prospective cohort study enrolled 1,997 individuals aged 7 to 9 years in 11 elementary schools in Mojiang, China. Cycloplegic refraction and biometry were performed at baseline and 4-year visits. The baseline fundus photographs were taken, and TD, defined as the percentage of exposed choroidal vessel area in the photographs, was quantified using an artificial intelligence-assisted semiautomatic labeling approach. After the exclusion of 330 ineligible participants because of loss to follow-up or ineligible fundus photographs, logistic models were used to assess the association of TD with rapid AL elongation (>0.36 mm/year) and SE progression (>1.00 D/year). RESULTS: The prevalence of tessellation was 477 of 1,667 (28.6%) and mean TD was 0.008 ± 0.019. The mean AL elongation and SE progression in 4 years were 0.90 ± 0.58 mm and -1.09 ± 1.25 D. Higher TD was associated with longer baseline AL (ß, 0.030; 95% confidence interval: 0.015-0.046; P < 0.001) and more myopic baseline SE (ß, -0.017; 95% confidence interval: -0.032 to -0.002; P = 0.029). Higher TD was associated with rapid AL elongation (odds ratio, 1.128; 95% confidence interval: 1.055-1.207; P < 0.001) and SE progression (odds ratio, 1.123; 95% confidence interval: 1.020-1.237; P = 0.018). CONCLUSION: Tessellation density is a potential indicator of rapid AL elongation and refractive progression in children. TD measurement could be a routine to monitor AL elongation.


Assuntos
Inteligência Artificial , Miopia , Criança , Humanos , Estudos Prospectivos , Refração Ocular , Testes Visuais , Miopia/diagnóstico , Miopia/epidemiologia , Comprimento Axial do Olho
7.
BMC Ophthalmol ; 24(1): 6, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172796

RESUMO

BACKGROUND: To investigate the relationship between body weight and Axial length in guinea pigs. METHODS: Forty pigmented guinea pigs were randomly divided into two groups, namely control group and negative lens-induced myopization (LIM) group. After measuring the baseline axial length and body weight (BW), guinea pigs of LIM group received bilateral negative lens-induced myopization using - 10.0 diopters lenses. One week later, the lenses were removed and biometric and ophthalmoscopic examinations were repeated. RESULTS: Two groups of guinea pigs showed no statistical difference in initial body weight and eye axis length. Compared to the control group, the lens-induced group had a lower weight (P = 0.02) and a longer axial length (P < 0.01) at the end of study Neither at baseline nor at week 1 did AL correlate with BW in both groups (Control Baseline: r = 0.306, P = 0.19; Control Week1: r = 0.333, P = 0.15; LIM Baseline: r=-0.142, P = 0.55; LIM Week 1: r = 0.189, P = 0.42). Lens-induction had a significant effect on axial elongation (P < 0.01) while body weight had no impact on such aspect (P > 0.05). CONCLUSION: In guinea pigs of the same age, axial length was not correlated with body weight. Also, baseline body weight had no impact on natural axial length growth or lens-induced myopia. Lens-induction caused a significant reduction in body weight gain.


Assuntos
Cristalino , Miopia , Animais , Cobaias , Miopia/etiologia , Comprimento Axial do Olho , Biometria , Modelos Animais de Doenças
8.
BMC Ophthalmol ; 24(1): 143, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38549060

RESUMO

AIM: To investigate the correlation of angles α and κ with the refractive and biological parameters in children. METHODS: This case-series study included 438 eyes of 219 children (males/females = 105/114, age: 3-15 years). Ocular biometric parameters, including axial length, corneal radius of curvature (CR), white-to-white distance (WTW), angle κ and angle α, were measured using IOL Master 700; auto-refraction were assessed under cycloplegia. The eyes were assigned to different groups based on CR, WTW, and gender to compare the angles α and κ, and analyze the correlations between the differences of biological parameters on angles α and κ. RESULTS: The means of axial length, CR, WTW, angle α, and angle κ were 23.24 ± 1.14 mm, 7.79 ± 0.27 mm, 11.68 ± 0.41 mm, 0.45 ± 0.25 mm, and 0.27 ± 0.22 mm, respectively. Angle α was correlated with CR and WTW (fixed effect coefficient [FEC] = 0.237, p = 0.015; FEC = -0.109, p = 0.003; respectively), and angle κ also correlated with CR and WTW (FEC = 0.271, p = 0.003; FEC = -0.147, p < 0.001, respectively). Comparing subgroups, the large CR and small WTW group had larger angles α (0.49 ± 0.27 vs. 0.41 ± 0.21, p < 0.001; 0.46 ± 0.27 vs. 0.44 ± 0.21, p < 0.05, respectively) and κ (0.29 ± 0.25 vs. 0.24 ± 0.15, p < 0.01; 0.29 ± 0.25 vs. 0.26 ± 0.19, p < 0.05, respectively). The differences in interocular angles α and κ showed correlation with interocular WTW (r = - 0.255, p < 0.001; r = - 0.385, p < 0.001). Eyes with smaller WTW tended to have larger angle κ (0.28 ± 0.27 vs. 0.25 ± 0.15, p < 0.05). CONCLUSION: The size of angle α/κ may be correlated to CR and WTW, and a larger WTW eye may suggest a smaller angle κ compared with the fellow eye.


Assuntos
Presbiopia , Refração Ocular , Criança , Humanos , Feminino , Masculino , Pré-Escolar , Adolescente , Testes Visuais , Córnea , Biometria , Comprimento Axial do Olho
9.
BMC Ophthalmol ; 24(1): 126, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504225

RESUMO

BACKGROUND: This study evaluates the impact of corneal power on the accuracy of 14 newer intraocular lens (IOL) calculation formulas in cataract surgery. The aim is to assess how these formulas perform across different corneal curvature ranges, thereby guiding more precise IOL selection. METHODS: In this retrospective case series, 336 eyes from 336 patients who underwent cataract surgery were studied. The cohort was divided into three groups according to preoperative corneal power. Key metrics analyzed included mean prediction error (PE), standard deviation of PE (SD), mean absolute prediction error (MAE), median absolute error (MedAE), and the percentage of eyes with PE within ± 0.25 D, 0.50 D, ± 0.75 D, ± 1.00 D and ± 2.00 D. RESULTS: In the flat K group (Km < 43 D), VRF-G, Emmetropia Verifying Optical Version 2.0 (EVO2.0), Kane, and Hoffer QST demonstrated lower SDs (± 0.373D, ± 0.379D, ± 0.380D, ± 0.418D, respectively) compared to the VRF formula (all P < 0.05). EVO2.0 and K6 showed significantly different SDs compared to Barrett Universal II (BUII) (all P < 0.02). In the medium K group (43 D ≤ Km < 46 D), VRF-G, BUII, Karmona, K6, EVO2.0, Kane, and Pearl-DGS recorded lower MAEs (0.307D to 0.320D) than Olsen (OLCR) and Castrop (all P < 0.03), with RBF3.0 having the second lowest MAE (0.309D), significantly lower than VRF and Olsen (OLCR) (all P < 0.05). In the steep K group (Km ≥ 46D), RBF3.0, K6, and Kane achieved significantly lower MAEs (0.279D, 0.290D, 0.291D, respectively) than Castrop (all P < 0.001). CONCLUSIONS: The study highlights the varying accuracy of newer IOL formulas based on corneal power. VRF-G, EVO2.0, Kane, K6, and Hoffer QST are highly accurate for flat corneas, while VRF-G, RBF3.0, BUII, Karmona, K6, EVO2.0, Kane, and Pearl-DGS are recommended for medium K corneas. In steep corneas, RBF3.0, K6, and Kane show superior performance.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Estudos Retrospectivos , Córnea , Olho Artificial , Biometria , Refração Ocular , Óptica e Fotônica , Comprimento Axial do Olho
10.
BMC Ophthalmol ; 24(1): 77, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378504

RESUMO

PURPOSE: To report the refractive outcomes of long (≥25.00 mm) and short (≤22.00 mm) axial length (AL) eyes undergoing immediately sequential bilateral cataract surgery (ISBCS). METHODS: In this retrospective cohort study, patients who underwent ISBCS were identified and eyes of patients with bilateral long and short ALs were included. Pre- and postoperative biometry, autorefraction, and ocular comorbidities or complications were recorded. The primary outcome was the mean refractive prediction error. RESULTS: Thirty-seven patients (74 eyes) with long ALs and 18 patients (36 eyes) with short ALs were included. The means ± standard deviations of the ALs were 26.40 ± 1.38 mm and 21.44 ± 0.46 mm in the long and short AL groups, respectively. In long AL eyes, the mean absolute error from the biometry-predicted refraction was - 0.16 ± 0.46 D, corresponding to 74% of eyes achieving a refraction within ±0.50 D of the predicted value. In short AL eyes, the mean absolute error was - 0.63 ± 0.73 D, corresponding to 44% of eyes achieving a refraction within ±0.50 D of the predicted value. Eight (44.4%) patients with short AL eyes had a myopic deviation greater than ±0.50 D from the predicted result in both eyes. CONCLUSIONS: Compared to patients with long AL eyes, ISBCS in patients with short ALs had a wider variance in refractive outcome and a lower rate of achieving a postoperative refraction within ±0.50 D of the predicted target.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Erros de Refração , Humanos , Acuidade Visual , Implante de Lente Intraocular/efeitos adversos , Estudos Retrospectivos , Lentes Intraoculares/efeitos adversos , Refração Ocular , Erros de Refração/etiologia , Biometria , Comprimento Axial do Olho , Catarata/complicações , Extração de Catarata/efeitos adversos
11.
BMC Ophthalmol ; 24(1): 191, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664659

RESUMO

BACKGROUND: To assess the age and timeline distribution of ocular axial length shortening among myopic children treated with photobiomodulation therapy in the real world situations. METHODS: Retrospective study of photobiomodulation therapy in Chinese children aged 4 to 13 years old where axial length measurements were recorded and assessed to determine effectiveness at two age groups (4 ∼ 8 years old group and 9 ∼ 13 years old group). Data was collected from myopic children who received photobiomodulation therapy for 6 ∼ 12 months. Effectiveness of myopia control was defined as any follow-up axial length ≤ baseline axial length, confirming a reduction in axial length. Independent t-test was used to compare the effectiveness of the younger group and the older group with SPSS 22.0. RESULTS: 342 myopic children were included with mean age 8.64 ± 2.20 years and baseline mean axial length of 24.41 ± 1.17 mm. There were 85.40%, 46.30%, 71.20% and 58.30% children with axial length shortening recorded at follow-up for 1 month, 3 months, 6 months and 12 months, respectively. With respect to the axial length shortened eyes, the mean axial length difference (standard deviation) was - 0.039 (0.11) mm, -0.032 (0.11) mm, -0.037 (0.12) mm, -0.028 (0.57) mm at 1, 3, 6, and 12-month follow-up, respectively. Greater AL shortening was observed among the older group who had longer baseline axial lengths than the younger group (P < 0.001). CONCLUSIONS: Overall myopia control effectiveness using photobiomodulation therapy was shown to be age and time related, with the maximum absolute reduction in axial elongation being cumulative.


Assuntos
Comprimento Axial do Olho , Terapia com Luz de Baixa Intensidade , Miopia , Humanos , Estudos Retrospectivos , Criança , Feminino , Masculino , Miopia/fisiopatologia , Miopia/radioterapia , Adolescente , Pré-Escolar , Terapia com Luz de Baixa Intensidade/métodos , Refração Ocular/fisiologia , Seguimentos
12.
BMC Ophthalmol ; 24(1): 183, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649861

RESUMO

AIM: To evaluate the objective visual outcomes following implantation of extended depth of focus intraocular lens (EDOF IOL) in individuals with varying axial lengths (AL) and targeted refraction. METHODS: This retrospective study comprised age-matched eyes that underwent implantation of the EDOF IOL. Eyes were categorized based on AL into groups: control group with AL < 26 mm; high myopia group with AL ≥ 26 mm. Each group was then subdivided based on postoperative spherical equivalent (SE). Follow-up at three months included assessment of uncorrected visual acuity at different distances, contrast sensitivity (CS), refractive outcomes, and spectacle independence. RESULTS: Overall, this study included 100 eyes from 100 patients, comprising 50 males (50.00%) and 50 females (50.00%), with 20 eyes in each group. In the control group, the uncorrected distance visual acuity (UDVA) at 5 and 3 m (m) in the - 1.50 to -0.75 group was inferior to that of the - 0.75 to 0.00 group (P = 0.004). Conversely, the uncorrected near visual acuity (UNVA) at 33 cm in the - 1.50 to -0.75 group was superior to that of the - 0.75 to 0.00 group (P = 0.005). Within the high myopia group, the UDVA at 5 and 3 m in the - 2.25 to -1.50 group was worse than in the - 0.75 to 0.00 group (P = 0.009 and 0.008, respectively). However, the UNVA at 33 cm in the - 2.25 to -1.50 group was better than in the - 0.75 to 0.00 group (P = 0.020). No significant differences were observed among the groups for corrected distance visual acuity (CDVA) (P > 0.05). Additionally, in the high myopia group, the CS of the - 2.25 to -1.50 group was lower compared to that of the - 0.75 to 0.00 group (P = 0.017). Among high myopia patients, 90.00% with refraction ranging from - 1.50 to -0.75 reported achieving overall spectacle independence. CONCLUSIONS: Implantation of extended depth of focus intraocular lenses (IOLs) yields satisfactory visual and refractive outcomes in eyes with axial myopia. Among high myopia patients, a refraction ranging from - 1.50 to -0.75 diopters achieves superior visual quality compared to other postoperative myopic diopters.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Miopia , Refração Ocular , Acuidade Visual , Humanos , Feminino , Masculino , Estudos Retrospectivos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Miopia/fisiopatologia , Miopia/cirurgia , Idoso , Desenho de Prótese , Adulto , Sensibilidades de Contraste/fisiologia , Facoemulsificação , Pseudofacia/fisiopatologia , Comprimento Axial do Olho , Percepção de Profundidade/fisiologia , Seguimentos
13.
BMC Ophthalmol ; 24(1): 207, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711043

RESUMO

PURPOSE: To understand the ocular biometric parameters characteristics and refractive errors in 3-to 6-year-old preschool children in Chengdu, China, and to investigate the prevalence of refractive errors. METHOD: A school-based cross-sectional study was conducted in Chengdu from 2020 to2022 with a total of 666 kindergartens. All children were measured by non-cycloplegic autorefraction and uncorrected visual acuity (UCVA) and ocular biometric parameters. Finally, univariate linear regression models were used to analyze the relationship between ocular biometric parameters and refraction. RESULTS: A total of 108,578 preschool children aged 3-6 underwent examinations, revealing a myopia prevalence of 6.1%. The mean axial length (AL), keratometry (K), corneal radius (CR), axial length/corneal radius (AL/CR) Ratio, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and vitreous chamber depth (VCD) were 22.35 ± 0.69 mm, 43.35 ± 1.58 D, 7.80 ± 0.28 mm, 2.87 ± 0.08, 533.31 ± 32.51 µm, 2.70 ± 0.28 mm, 3.91 ± 0.27 mm, and 15.20 ± 0.68 mm, respectively. With increasing age, AL, CR, AL/CR ratio, CCT, ACD, LT, and VCD also increased. Regardless of age, males consistently exhibited longer AL, flatter corneal curvature, shallower ACD, thicker CCT, thinner LT, and longer VCD compared to females. AL, K, CR, LT, and VCD all showed significant linear relationships with SE (all P < 0.001) in univariate linear regression analysis after adjusting for gender and age. CONCLUSION: The prevalence of myopia among preschool children aged 3-6 in Chengdu is relatively low. Ocular biometric parameters affecting refractive errors include AL, K, CR, LT, and VCD. The preschool period serves as a critical phase for myopia prevention and control.


Assuntos
Biometria , Refração Ocular , Acuidade Visual , Humanos , Feminino , Masculino , Estudos Transversais , China/epidemiologia , Refração Ocular/fisiologia , Pré-Escolar , Criança , Acuidade Visual/fisiologia , Prevalência , Comprimento Axial do Olho , Córnea/patologia , Córnea/anatomia & histologia , Erros de Refração/epidemiologia , Erros de Refração/fisiopatologia , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , Miopia/epidemiologia , Miopia/fisiopatologia
14.
Ophthalmic Physiol Opt ; 44(1): 199-205, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37897105

RESUMO

PURPOSE: Accumulated axial growth observed during a 6-year clinical trial of a dual focus myopia control contact lens was used to explore different approaches to assess treatment efficacy. METHODS: Axial length measurements from 170 eyes in a 6-year clinical trial of a dual focus myopia control lens (MiSight 1 day, CooperVision) were analysed. Treatment groups comprised one having undergone 6 years of treatment and the other (the initial control group) having 3 years of treatment after 3 years of wearing a single vision control lens. Efficacy was assessed by comparing accumulated ocular growth during treatment to that expected of untreated myopic and emmetropic eyes. The impact of treatment on delaying axial growth was quantified by comparing the increased time required to reach criterion growths for treated eyes and survivor analysis approaches. RESULTS: When compared to the predicted accumulated growth of untreated eyes, 6 years of treatment reduced growth by 0.52 mm, while 3 years of treatment initiated 3 years later reduced growth by 0.19 mm. Accumulated differences between the growth of treated and untreated myopic eyes ranged between 67% and 52% of the untreated myopic growth, and between 112% and 86% of the predicted difference in growth between untreated myopic and age-matched emmetropic eyes. Treated eyes took almost 4 years longer to reach their final accumulated growth than untreated eyes. Treatment increased the time to reach criterion growths by 2.3-2.7 times. CONCLUSION: Estimated growth of age-matched emmetropic and untreated myopic eyes provided evidence of an accumulated slowing in axial elongation of 0.52 mm over 6 years, and the treated growth remained close to that expected of emmetropic eyes. Six years of dual focus myopia control delayed the time to reach the final growth level by almost 4 years.


Assuntos
Lentes de Contato , Miopia , Humanos , Comprimento Axial do Olho , Olho , Miopia/prevenção & controle , Refração Ocular , Resultado do Tratamento , Ensaios Clínicos como Assunto
15.
Ophthalmic Physiol Opt ; 44(2): 472-480, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38234008

RESUMO

PURPOSE: With the rising prevalence of myopia, especially among the young, orthokeratology (Ortho-K) stands out as a promising approach, not only to reduce myopia but also to control the progression of axial length (AL). This study examined how the intersection area between the pupil and defocus ring influenced retinal defocus and axial growth after Ortho-K. METHODS: A case-control study was conducted with 100 participants (100 eyes). Both AL and the refraction difference value (RDV), that is, the peripheral refractive error measured with respect to the central value after wearing Ortho-K lenses, were determined. Subjects were categorised into two groups based on the size of the intersection area after 3 months of lens wear: Group A (<4.58 mm2 ) and Group B (≥4.58 mm2 ). RESULTS: Group B demonstrated significantly lower changes in AL and RDV at 30-40° and 40-53° compared with Group A after 3 months of lens wear (all p < 0.05). After 6 months of lens wear, Group B showed significantly lower changes in AL and RDV in the 40-53° region compared with Group A (all p < 0.05). Correlation analysis revealed that as the intersection area increased, the changes in AL and RDV at 0-53°, 30-40° and 40-53° eccentricity decreased after both 3 and 6 months of lens wear (all p < 0.01). CONCLUSIONS: A larger intersection area between the pupil and defocus ring within a certain time period can cause a greater amount of myopic defocus at 30-53° from the fovea. The results suggest that a larger intersection area might lead to more effective control of axial growth.


Assuntos
Miopia , Procedimentos Ortoceratológicos , Erros de Refração , Humanos , Pupila , Estudos de Casos e Controles , Retina , Refração Ocular , Comprimento Axial do Olho , Procedimentos Ortoceratológicos/métodos
16.
Ophthalmic Physiol Opt ; 44(5): 1017-1030, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38760986

RESUMO

PURPOSE: To assess the feasibility of using multifunction instruments to measure axial length for monitoring myopia progression in children and adults. METHODS: Axial length was measured in 60 children (aged 6-18 years) and 60 adults (aged 19-50 years) with multifunction instruments (Myah and Myopia Master) and stand-alone biometers (Lenstar LS900 and IOLMaster 700). Repeatability (measurements by the same examiner) and reproducibility (measurements by different examiners) were computed as the within-subject standard deviation (Sw) and 95% limits of agreement (LoA). Inter-instrument agreement was computed as intraclass correlation coefficients. The threshold for detecting myopic progression was taken as 0.1 mm. Measures were repeated only in children following the administration of 1% tropicamide to determine the impact of cycloplegia on axial length. RESULTS: Overall, the IOLMaster 700 had the best repeatability in children (0.014 mm) and adults (0.009 mm). Repeatability Sw values for all devices ranged from 0.005 to 0.021 mm (children) and 0.003 to 0.016 mm (adults). In children, reproducibility fell within 0.1 mm 95% of the time for the Myah, Myopia Master and IOLMaster 700. Agreement among all devices was classified as excellent (ICC 0.999; 95% CI 0.998-0.999), but the 95% LoA among the Myah, Myopia Master and Lenstar LS900 was ≥0.1 mm. Cycloplegia had no statistically significant effect on axial length (all p > 0.13). CONCLUSIONS: The Myah and Myopia Master multifunction instruments demonstrated good repeatability and reproducibility, and their accuracy was comparable to stand-alone biometers. Axial length measurements using different instruments can be considered interchangeable but should be compared with some caution. Accurate axial length measurements can be obtained without cycloplegia. The multifunction instruments Myah and Myopia Master are as well suited for monitoring myopia progression in children as the stand-alone biometers IOLMaster 700 and Lenstar LS900.


Assuntos
Comprimento Axial do Olho , Progressão da Doença , Miopia , Humanos , Criança , Adolescente , Masculino , Feminino , Adulto , Reprodutibilidade dos Testes , Adulto Jovem , Comprimento Axial do Olho/diagnóstico por imagem , Miopia/fisiopatologia , Miopia/diagnóstico , Pessoa de Meia-Idade , Biometria/instrumentação , Biometria/métodos , Refração Ocular/fisiologia , Estudos de Viabilidade
17.
Ophthalmic Physiol Opt ; 44(5): 954-962, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38557968

RESUMO

PURPOSE: To determine whether visible light is needed to elicit axial eye shortening by exposure to long wavelength light. METHODS: Incoherent narrow-band red (620 ± 10 nm) or near-infrared (NIR, 875 ± 30 nm) light was generated by an array of light-emitting diodes (LEDs) and projected monocularly in 17 myopic and 13 non-myopic subjects for 10 min. The fellow eye was occluded. Light sources were positioned 50 cm from the eye in a dark room. Axial length (AL) was measured before and after the exposure using low-coherence interferometry. RESULTS: Non-myopic subjects responded to red light with significant eye shortening, while NIR light induced minor axial elongation (-13.3 ± 17.3 µm vs. +6.5 ± 11.6 µm, respectively, p = 0.005). Only 41% of the myopic subjects responded to red light exposure with a decrease in AL and changes were therefore, on average, not significantly different from those observed with NIR light (+0.2 ± 12.1 µm vs. +1.1 ± 11.2 µm, respectively, p = 0.83). Interestingly, there was a significant correlation between refractive error and induced changes in AL after exposure to NIR light in myopic eyes (r(15) = -0.52, p = 0.03) and induced changes in AL after exposure to red light in non-myopic eyes (r(11) = 0.62, p = 0.02), with more induced axial elongation with increasing refractive error. CONCLUSIONS: Incoherent narrow-band red light at 620 nm induced axial shortening in 77% of non-myopic and 41% of myopic eyes. NIR light did not induce any significant changes in AL in either refractive group, suggesting that the beneficial effect of red laser light therapy on myopia progression requires visible stimulation and not simply thermal energy.


Assuntos
Comprimento Axial do Olho , Raios Infravermelhos , Miopia , Humanos , Comprimento Axial do Olho/diagnóstico por imagem , Miopia/fisiopatologia , Masculino , Feminino , Raios Infravermelhos/efeitos adversos , Adulto , Adulto Jovem , Interferometria/métodos , Refração Ocular/fisiologia , Luz/efeitos adversos , Adolescente
18.
Ophthalmic Physiol Opt ; 44(5): 1000-1009, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38666416

RESUMO

PURPOSE: To present a paraxial method to estimate the influence of variations in ocular biometry on changes in refractive error (S) at a population level and apply this method to literature data. METHODS: Error propagation was applied to two methods of eye modelling, referred to as the simple method and the matrix method. The simple method defines S as the difference between the axial power and the whole-eye power, while the matrix method uses more accurate ray transfer matrices. These methods were applied to literature data, containing the mean ocular biometry data from the SyntEyes model, as well as populations of premature infants with or without retinopathy, full-term infants, school children and healthy and diabetic adults. RESULTS: Applying these equations to 1000 SyntEyes showed that changes in axial length provided the most important contribution to the variations in refractive error (57%-64%), followed by lens power/gradient index power (16%-31%) and the anterior corneal radius of curvature (10%-13%). All other components of the eye contributed <4%. For young children, the largest contributions were made by variations in axial length, lens and corneal power for the simple method (67%, 23% and 8%, respectively) and by variations in axial length, gradient lens power and anterior corneal curvature for the matrix method (55%, 21% and 14%, respectively). During myopisation, the influence of variations in axial length increased from 54.5% to 73.4%, while changes in corneal power decreased from 9.82% to 6.32%. Similarly, for the other data sets, the largest contribution was related to axial length. CONCLUSIONS: This analysis confirms that the changes in ocular refraction were mostly associated with variations in axial length, lens and corneal power. The relative contributions of the latter two varied, depending on the particular population.


Assuntos
Comprimento Axial do Olho , Biometria , Refração Ocular , Erros de Refração , Humanos , Erros de Refração/fisiopatologia , Erros de Refração/diagnóstico , Biometria/métodos , Refração Ocular/fisiologia , Criança , Comprimento Axial do Olho/diagnóstico por imagem , Córnea/diagnóstico por imagem , Adulto , Lactente , Pré-Escolar , Recém-Nascido , Masculino , Feminino , Adolescente
19.
Clin Exp Ophthalmol ; 52(5): 507-515, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38400607

RESUMO

BACKGROUND: A rebound in myopia progression following cessation of atropine eyedrops has been reported, yet there is limited data on the effects of stopping 0.01% atropine compared to placebo control. This study tested the hypothesis that there is minimal rebound myopia progression after cessation of 0.01% atropine eyedrops, compared to a placebo. METHODS: Children with myopia (n = 153) were randomised to receive 0.01% atropine eyedrops or a placebo (2:1 ratio) daily at bedtime during the 2-year treatment phase of the study. In the third year (wash-out phase), all participants ceased eyedrop instillation. Participants underwent an eye examination every 6 months, including measurements of spherical equivalent (SphE) after cycloplegia and axial length (AL). Changes in the SphE and AL during the wash-out phase and throughout the 3 years of the study (treatment + wash-out phase) were compared between the treatment and control groups. RESULTS: During the 1-year wash-out phase, SphE and AL progressed by -0.41D (95% CI = -0.33 to -0.22) and +0.20 mm (95% CI = -0.46 to -0.36) in the treatment group compared to -0.28D (95% CI = 0.11 to 0.16) and +0.13 mm (95% CI = 0.18 to 0.21) in the control group. Progression in the treatment group was significantly faster than in the control group (p = 0.016 for SphE and <0.001 for AL). Over the 3-year study period, the cumulative myopia progression was similar between the atropine and the control groups. CONCLUSIONS: These findings showed evidence of rapid myopia progression following cessation of 0.01% atropine. Further investigations are warranted to ascertain the long-term effects of atropine eyedrops.


Assuntos
Atropina , Comprimento Axial do Olho , Progressão da Doença , Midriáticos , Soluções Oftálmicas , Refração Ocular , Humanos , Atropina/administração & dosagem , Masculino , Feminino , Criança , Midriáticos/administração & dosagem , Refração Ocular/fisiologia , Método Duplo-Cego , Miopia/tratamento farmacológico , Miopia/fisiopatologia , Austrália Ocidental , Adolescente
20.
Eye Contact Lens ; 50(1): 41-47, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37934166

RESUMO

OBJECTIVES: To develop and validate a deep learning-based model for predicting 12-month axial length (AL) elongation using baseline factors and early corneal topographic changes in children treated with orthokeratology (Ortho-K) and to investigate the association between these factors and myopia control impact. METHODS: A total of 115 patients with Ortho-K were enrolled. Influential baseline factors that have a statistically significant correlation with 12-month AL from medical records were selected using Pearson correlation coefficients. Simultaneously, the height, area, and volume of the defocus region were directly calculated from the corneal topography. Then, the prediction model was developed by combining multiple linear regression and deep neural network and evaluated in an independent group (83 patients for developing the algorithm and 32 patients for evaluation). RESULTS: Age ( r= -0.30, P <0.001), spherical equivalent refractive (SE; r =0.20, P =0.032), and sex ( r =0.19, P =0.032) were significantly correlated with the AL elongation while pupil diameter, flat k, steep k, horizontal corneal diameter (white to white), anterior chamber depth, and cell density were not ( P >0.1). The prediction model was developed using age, SE, and corneal topographic variation, and the validation of the model demonstrated its effectiveness in predicting AL elongation. CONCLUSIONS: The AL elongation was accurately predicted by the deep learning model, which effectively incorporated both baseline factors and corneal topographic variation.


Assuntos
Aprendizado Profundo , Miopia , Procedimentos Ortoceratológicos , Criança , Humanos , Comprimento Axial do Olho , Miopia/terapia , Topografia da Córnea , Refração Ocular , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa