Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62.832
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38587261

RESUMO

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bioprótese/efeitos adversos , Insuficiência Cardíaca , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
2.
Lancet ; 403(10445): 2695-2708, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38795719

RESUMO

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
3.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38552656

RESUMO

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Annu Rev Biomed Eng ; 26(1): 503-528, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38594922

RESUMO

Significant advances in bionic prosthetics have occurred in the past two decades. The field's rapid expansion has yielded many exciting technologies that can enhance the physical, functional, and cognitive integration of a prosthetic limb with a human. We review advances in the engineering of prosthetic devices and their interfaces with the human nervous system, as well as various surgical techniques for altering human neuromusculoskeletal systems for seamless human-prosthesis integration. We discuss significant advancements in research and clinical translation, focusing on upper limbprosthetics since they heavily rely on user intent for daily operation, although many discussed technologies have been extended to lower limb prostheses as well. In addition, our review emphasizes the roles of advanced prosthetics technologies in complex interactions with humans and the technology readiness levels (TRLs) of individual research advances. Finally, we discuss current gaps and controversies in the field and point out future research directions, guided by TRLs.


Assuntos
Membros Artificiais , Biônica , Desenho de Prótese , Extremidade Superior , Humanos , Engenharia Biomédica/métodos , Amputados
5.
Arterioscler Thromb Vasc Biol ; 44(5): 1065-1085, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38572650

RESUMO

Blood vessels are subjected to complex biomechanical loads, primarily from pressure-driven blood flow. Abnormal loading associated with vascular grafts, arising from altered hemodynamics or wall mechanics, can cause acute and progressive vascular failure and end-organ dysfunction. Perturbations to mechanobiological stimuli experienced by vascular cells contribute to remodeling of the vascular wall via activation of mechanosensitive signaling pathways and subsequent changes in gene expression and associated turnover of cells and extracellular matrix. In this review, we outline experimental and computational tools used to quantify metrics of biomechanical loading in vascular grafts and highlight those that show potential in predicting graft failure for diverse disease contexts. We include metrics derived from both fluid and solid mechanics that drive feedback loops between mechanobiological processes and changes in the biomechanical state that govern the natural history of vascular grafts. As illustrative examples, we consider application-specific coronary artery bypass grafts, peripheral vascular grafts, and tissue-engineered vascular grafts for congenital heart surgery as each of these involves unique circulatory environments, loading magnitudes, and graft materials.


Assuntos
Prótese Vascular , Hemodinâmica , Humanos , Animais , Modelos Cardiovasculares , Falha de Prótese , Estresse Mecânico , Fenômenos Biomecânicos , Mecanotransdução Celular , Implante de Prótese Vascular/efeitos adversos , Desenho de Prótese , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/etiologia , Remodelação Vascular
6.
Proc Natl Acad Sci U S A ; 119(29): e2203116119, 2022 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-35858310

RESUMO

We use magnetohydrodynamic levitation as a means to create a soft, elastomeric, solenoid-driven pump (ESP). We present a theoretical framework and fabrication of a pump designed to address the unique challenges of soft robotics, maintaining pumping performance under deformation. Using a permanent magnet as a piston and ferrofluid as a liquid seal, we model and construct a deformable displacement pump. The magnet is driven back and forth along the length of a flexible core tube by a series of solenoids made of thin conductive wire. The magnet piston is kept concentric within the tube by Maxwell stresses within the ferrofluid and magnetohydrodynamic levitation, as viscous lift pressure is created due to its forward velocity. The centering of the magnet reduces shear stresses during pumping and improves efficiency. We provide a predictive model and capture the transient nonlinear dynamics of the magnet during operation, leading to a parametric performance curve characterizing the ESP, enabling goal-driven design. In our experimental validation, we report a shut-off pressure of 2 to 8 kPa and run-out flow rate of 50 to 320 mL⋅min-1, while subject to deformation of its own length scale, drawing a total of 0.17 W. This performance leads to the highest reported duty point (i.e., pressure and flow rate provided under load) for a pump that operates under deformation of its own length scale. We then integrate the pump into an elastomeric chassis and squeeze it through a tortuous pathway while providing continuous fluid pressure and flow rate; the vehicle then emerges at the other end and propels itself swimming.


Assuntos
Coração Auxiliar , Robótica , Elasticidade , Desenho de Prótese , Viscosidade
7.
Eur Heart J ; 45(3): 198-210, 2024 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-37874971

RESUMO

BACKGROUND AND AIMS: Transcatheter pulmonary valve implantation (TPVI) is indicated to treat right-ventricular outflow tract (RVOT) dysfunction related to congenital heart disease (CHD). Outcomes of TPVI with the SAPIEN 3 valve that are insufficiently documented were investigated in the EUROPULMS3 registry of SAPIEN 3-TPVI. METHODS: Patient-related, procedural, and follow-up outcome data were retrospectively assessed in this observational cohort from 35 centres in 15 countries. RESULTS: Data for 840 consecutive patients treated in 2014-2021 at a median age of 29.2 (19.0-41.6) years were obtained. The most common diagnosis was conotruncal defect (70.5%), with a native or patched RVOT in 50.7% of all patients. Valve sizes were 20, 23, 26, and 29 mm in 0.4%, 25.5%, 32.1%, and 42.0% of patients, respectively. Valve implantation was successful in 98.5% [95% confidence interval (CI), 97.4%-99.2%] of patients. Median follow-up was 20.3 (7.1-38.4) months. Eight patients experienced infective endocarditis; 11 required pulmonary valve replacement, with a lower incidence for larger valves (P = .009), and four experienced pulmonary valve thrombosis, including one who died and three who recovered with anticoagulation. Cumulative incidences (95%CI) 1, 3, and 6 years after TPVI were as follows: infective endocarditis, 0.5% (0.0%-1.0%), 0.9% (0.2%-1.6%), and 3.8% (0.0%-8.4%); pulmonary valve replacement, 0.4% (0.0%-0.8%), 1.3% (0.2%-2.4%), and 8.0% (1.2%-14.8%); and pulmonary valve thrombosis, 0.4% (0.0%-0.9%), 0.7% (0.0%-1.3%), and 0.7% (0.0%-1.3%), respectively. CONCLUSIONS: Outcomes of SAPIEN 3 TPVI were favourable in patients with CHD, half of whom had native or patched RVOTs.


Assuntos
Endocardite Bacteriana , Endocardite , Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Trombose , Adulto , Humanos , Cateterismo Cardíaco/efeitos adversos , Endocardite/epidemiologia , Endocardite Bacteriana/complicações , Cardiopatias Congênitas/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/epidemiologia , Insuficiência da Valva Pulmonar/cirurgia , Sistema de Registros , Estudos Retrospectivos , Trombose/etiologia , Resultado do Tratamento
8.
Eur Heart J ; 45(33): 3031-3041, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38747561

RESUMO

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all [100%; 95% confidence interval (CI) 94%-100.0%, P < .001] patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 [98.3%; 95% CI (91.1%-100%)] patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1%-99.0%). Within 90 days, freedom from mortality was 95% [95% CI (86.1%-99.0%)], without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favourable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Idoso , Estudos Prospectivos , Estenose da Valva Aórtica/cirurgia , Falha de Prótese , Desenho de Prótese , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Resultado do Tratamento , Oclusão Coronária/cirurgia , Complicações Pós-Operatórias/epidemiologia
9.
Circulation ; 147(17): 1264-1276, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-36866664

RESUMO

BACKGROUND: Concerns have been raised about the long-term performance of aortic stent grafts for the treatment of abdominal aortic aneurysms, in particular, unibody stent grafts (eg, Endologix AFX AAA stent grafts). Only limited data sets are available to evaluate the long-term risks related to these devices. The SAFE-AAA Study (Comparison of Unibody and Non-Unibody Endografts for Abdominal Aortic Aneurysm Repair in Medicare Beneficiaries Study) was designed with the Food and Drug Administration to provide a longitudinal assessment of the safety of unibody aortic stent grafts among Medicare beneficiaries. METHODS: The SAFE-AAA Study was a prespecified, retrospective cohort study evaluating whether unibody aortic stent grafts are noninferior to non-unibody aortic stent grafts with respect to the composite primary outcome of aortic reintervention, rupture, and mortality. Procedures were evaluated from August 1, 2011, through December 31, 2017. The primary end point was evaluated through December 31, 2019. Inverse probability weighting was used to account for imbalances in observed characteristics. Sensitivity analyses were used to evaluate the effect of unmeasured confounding, including assessment of the falsification end points heart failure, stroke, and pneumonia. A prespecified subgroup included patients treated from February 22, 2016, through December 31, 2017, corresponding to the market release of the most contemporary unibody aortic stent grafts (Endologix AFX2 AAA stent graft). RESULTS: Of 87 163 patients who underwent aortic stent grafting at 2146 US hospitals, 11 903 (13.7%) received a unibody device. The average age of the total cohort was 77.0±6.7 years, 21.1% were female, 93.5% were White, 90.8% had hypertension, and 35.8% used tobacco. The primary end point occurred in 73.4% of unibody device-treated patients versus 65.0% of non-unibody device-treated patients (hazard ratio, 1.19 [95% CI, 1.15-1.22]; noninferior P value of 1.00; median follow-up, 3.4 years). Falsification end points were negligibly different between groups. In the subgroup treated with contemporary unibody aortic stent grafts, the cumulative incidence of the primary end point occurred in 37.5% of unibody device-treated patients and 32.7% of non-unibody device-treated patients (hazard ratio, 1.06 [95% CI, 0.98-1.14]). CONCLUSIONS: In the SAFE-AAA Study, unibody aortic stent grafts failed to meet noninferiority compared with non-unibody aortic stent grafts with respect to aortic reintervention, rupture, and mortality. These data support the urgency of instituting a prospective longitudinal surveillance program for monitoring safety events related to aortic stent grafts.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Feminino , Idoso , Estados Unidos , Idoso de 80 Anos ou mais , Masculino , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Estudos Prospectivos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Medicare , Stents , Desenho de Prótese
10.
Circulation ; 147(7): 575-585, 2023 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-36780380

RESUMO

BACKGROUND: Although some studies have investigated sex-related outcomes up to 5 years after percutaneous coronary intervention (PCI), analyses at longer follow-up (ie, to 10 years) in large cohorts treated exclusively with drug-eluting stent (DES) platforms are lacking. Therefore, this study aimed to define whether sex-related differences in long-term outcomes after PCI persist both in the DES era and at longer-term follow-up. METHODS: Individual data of patients treated with DES in 5 randomized controlled trials with 10-year follow-up were pooled. Patients were divided into 2 groups by sex. The analysis of individual participant data was performed using a 1-stage approach by entering a clustering effect by parent study in all univariable and multivariable models focusing on sex. The main outcomes of interest for this analysis included cardiovascular death, myocardial infarction, repeat revascularization, and definite stent thrombosis to 10 years after PCI. Survival was analyzed by the Kaplan-Meier method to estimate the time to first event, and differences between the 2 groups were tested with the log-rank test. Hazard ratios (HRs) and 95% CIs were calculated with a Cox proportional hazards model. Conventional multivariable analyses with adjustment for relevant variables were performed. RESULTS: Among 9700 patients undergoing PCI with DES implantation included in the present analysis, 2296 were women and 7404 were men. Through to 10 years, cardiovascular death occurred in 407 of the 2296 female patients and 1012 of the 7404 male patients (adjusted HR [HRadj], 0.94 [95% CI, 0.80-1.11]). Female sex was associated with a lower risk of repeat revascularization of the target lesion (HRadj, 0.80 [95% CI, 0.74-0.87]), target vessel (HRadj, 0.81 [95% CI, 0.76-0.87]), and nontarget vessels (HRadj, 0.69 [95% CI, 0.62-0.77]). Compared with male patients, female patients displayed an increased risk of myocardial infarction in the first 30 days after PCI with DES (HRadj, 1.65 [95% CI, 1.24-2.19]) but a comparable risk of myocardial infarction thereafter. The risk of definite stent thrombosis was not significantly different between female and male patients (HRadj, 1.14 [95% CI, 0.89-1.47]). CONCLUSIONS: Through to 10-year follow-up after PCI with DES, female patients are at increased risk of early myocardial infarction, receive fewer repeat revascularizations, and have no difference in cardiovascular mortality compared with male patients.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Feminino , Humanos , Masculino , Stents Farmacológicos/efeitos adversos , Estimativa de Kaplan-Meier , Infarto do Miocárdio/complicações , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Risco , Caracteres Sexuais , Stents/efeitos adversos , Trombose/etiologia , Resultado do Tratamento
11.
Ann Surg ; 280(4): 633-639, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38920026

RESUMO

OBJECTIVE: The objective of this study was to report long-term results of an ongoing physician-sponsored, investigational device exemption (IDE) pivotal clinical trial using physician-modified endovascular grafts (PMEGs) for the treatment of patients with juxtarenal aortic aneurysms. METHODS: Data from a nonrandomized, prospective, consecutively enrolling IDE clinical trial were used. Data collection began on April 1, 2011, and data lock occurred on January 2, 2024, with outcomes analysis through December 31, 2023. Primary safety and effectiveness end points were used to measure treatment success. The safety end point was defined as the proportion of subjects who experienced a major adverse event within 30 days of the procedure. The effectiveness end point was the proportion of subjects who achieved treatment success. Treatment success required the following at 12 months: technical success, defined as successful delivery and deployment of a PMEG with preservation of intended branch vessels; and freedom from: type I and III endoleak, stent graft migration >10 mm, aortic aneurysm sack enlargement >5 mm, and aortic aneurysm rupture or open conversion. RESULTS: Over the 12-year study period, 228 patients were enrolled; 205 began the implant procedure, and 203 received PMEG. Thirteen patients withdrew prior to PMEG. Two withdrew (<1.0%) after failure to deploy due to tortuous iliac anatomy and are tracked as intent to treat, and a total of 24 withdrew after receiving the PMEG implant. Forty-four patients died during the study period. A total of 14 were deemed lost to follow-up. Fifty-nine completed the 5-year follow-up period, and 62 remain active in follow-up visits.Aneurysm anatomy, operative details, and lengths of stay were recorded and included: aneurysm diameter (mean, 67.5 mm; range, 49-124 mm), proximal seal zone length (mean, 41.6 mm; range, 18.9-92.9 mm), graft modification time (mean, 48.7 min), procedure time (mean, 137.7 min), fluoroscopy time (mean, 33.8 min), contrast material use (mean, 93.0 mL), estimated blood loss (mean, 118.8 mL), length of hospital stay (mean, 3.7 d), and intensive care unit length of stay (mean, 1.6 d).A total of 575 fenestrations were created for 387 renal arteries, 181 superior mesenteric arteries (SMAs), and 7 celiac arteries. Renal arteries were in 96% of patients and included 410 renal artery stents in 203 patients. The SMA was stented as needed and included one patient with an SMA stent placed before the procedure, 19 during the procedure, and 2 patients who underwent stent placement after the procedure. There were no open conversions or device migrations and 1 partial explant due to late distal graft occlusion. Three ruptures (1.4%) were recorded on days 830, 1346, and 1460. There was 1 presumed graft infection at 750 days (<0.5%) treated with? Thirty-day all-cause mortality was 2.9% (6/204). One type Ia, 1 type Ib, and 7 type III endoleaks were identified during follow-up and treated with successful reintervention at the 1-year period. The overall rate of major adverse events at 30 days was 15% (29/194). Technical success was 93.7%, and overall treatment success was 82.6%. CONCLUSIONS: PMEG can be performed with low rates of long-term morbidity and mortality, confirming our early and midterm reports that endovascular repair with PMEG is safe, durable, and effective for managing patients with juxtarenal aortic aneurysms. While historically considered experimental, these results suggest that PMEG is a safe and durable option and should be considered for patients where off-the-shelf devices are not available.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Prótese Vascular , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares , Desenho de Prótese , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Masculino , Feminino , Idoso , Procedimentos Endovasculares/métodos , Estudos Prospectivos , Ruptura Aórtica/cirurgia , Procedimentos Cirúrgicos Eletivos/métodos , Resultado do Tratamento , Implante de Prótese Vascular/métodos , Pessoa de Meia-Idade , Stents , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Seguimentos , Fatores de Tempo
12.
Lancet ; 402(10412): 1529-1540, 2023 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-37660719

RESUMO

BACKGROUND: With increasing numbers of patients undergoing transcatheter aortic valve replacement (TAVR), data on management of failed TAVR, including repeat TAVR procedure, are needed. The aim of this study was to assess the safety and efficacy of redo-TAVR in a national registry. METHODS: This study included all consecutive patients in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry from Nov 9, 2011, to Dec 30, 2022 who underwent TAVR with balloon-expandable valves in failed transcatheter heart valves (redo-TAVR) or native aortic valves (native-TAVR). Procedural, echocardiographic, and clinical outcomes were compared between redo-TAVR and native-TAVR cohorts using propensity score matching. FINDINGS: Among 350 591 patients (1320 redo-TAVR; 349 271 native-TAVR), 1320 propensity-matched pairs of patients undergoing redo-TAVR and native-TAVR were analysed (redo-TAVR cohort: mean age 78 years [SD 9]; 559 [42·3%] of 1320 female, 761 [57·7%] male; mean predicted surgical risk of 30-day mortality 8·1%). The rates of procedural complications of redo-TAVR were low (coronary compression or obstruction: four [0·3%] of 1320; intraprocedural death: eight [0·6%] of 1320; conversion to open heart surgery: six [0·5%] of 1319) and similar to native-TAVR. There was no significant difference between redo-TAVR and native-TAVR populations in death at 30 days (4·7% vs 4·0%, p=0·36) or 1 year (17·5% vs 19·0%, p=0·57), and stroke at 30 days (2·0% vs 1·9%, p=0·84) or 1 year (3·2% vs 3·5%, p=0·80). Redo-TAVR reduced aortic valve gradients at 1 year, although they were higher in the redo-TAVR group compared with the native-TAVR group (15 mm Hg vs 12 mm Hg; p<0·0001). Moderate or severe aortic regurgitation rates were similar between redo-TAVR and native-TAVR groups at 1 year (1·8% vs 3·3%, p=0·18). Death or stroke after redo-TAVR were not significantly affected by the timing of redo-TAVR (before or after 1 year of index TAVR), or by index transcatheter valve type (balloon-expandable or non-balloon-expandable). INTERPRETATION: Redo-TAVR with balloon-expandable valves effectively treated dysfunction of the index TAVR procedure with low procedural complication rates, and death and stroke rates similar to those in patients with a similar clinical profile and predicted risk undergoing TAVR for native aortic valve stenosis. Redo-TAVR with balloon-expandable valves might be a reasonable treatment for failed TAVR in selected patients. FUNDING: Edwards Lifesciences.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Acidente Vascular Cerebral/etiologia , Sistema de Registros , Fatores de Risco , Desenho de Prótese
13.
Am Heart J ; 274: 84-94, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38729550

RESUMO

INTRODUCTION: Based on technical advancements and clinical evidence, transcatheter aortic valve implantation (TAVI) has been widely adopted. New generation TAVI valve platforms are continually being developed. Ideally, new valves should be superior or at least non-inferior regarding efficacy and safety, when compared to best-in-practice contemporary TAVI valves. METHODS AND ANALYSIS: The Compare-TAVI trial (ClinicalTrials.gov NCT04443023) was launched in 2020, to perform a 1:1 randomized comparison of new vs contemporary TAVI valves, preferably in all comers. Consecutive cohorts will be launched with sample sizes depending on the choice of interim analyses, expected event rates, and chosen superiority or non-inferiority margins. Enrollment has just been finalized in cohort B, comparing the Sapien 3/Sapien 3 Ultra Transcatheter Heart Valve (THV) series (Edwards Lifesciences, Irvine, California, USA) and the Myval/Myval Octacor THV series (Meril Life Sciences Pvt. Ltd., Vapi, Gujarat, India) balloon expandable valves. This non-inferiority study was aimed to include 1062 patients. The 1-year composite safety and efficacy endpoint comprises death, stroke, moderate-severe aortic regurgitation, and moderate-severe valve deterioration. Patients will be followed until withdrawal of consent, death, or completion of 10-year follow-up, whichever comes first. Secondary endpoints will be monitored at 30 days, 1, 3, 5, and 10 years. SUMMARY: The Compare-TAVI organization will launch consecutive cohorts wherein patients scheduled for TAVI are randomized to one of two valves. The aim is to ensure that the short- and long-term performance and safety of new valves being introduced is benchmarked against what achieved by best-in-practice contemporary valves.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Masculino , Feminino
14.
Am Heart J ; 277: 1-10, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39098754

RESUMO

BACKGROUND: Modern drug-eluting stents have seen significant improvements, yet still create a rigid cage within the coronary artery. There is a 2% to 4% annual incidence of target lesion failure (TLF) beyond 1 year, and half of the patients experience angina after 5 years. The DynamX bioadaptor is a sirolimus-eluting, thin (71 µm) cobalt-chromium platform with helical strands that unlock and separate after in vivo degradation of the bioresorbable polymer coating. This allows the vessel to return to normal physiological function and motion, along with compensatory adaptive remodeling, which may reduce the need for reintervention and alleviate angina following percutaneous coronary intervention (PCI). METHODS: The INFINITY-SWEDEHEART trial is a single-blind, registry-based randomized clinical trial (R-RCT) to evaluate the safety and effectiveness of the DynamX bioadaptor compared to the Resolute Onyx stent in the treatment of patients with ischemic heart disease with de novo native coronary artery lesions. The R-RCT framework allows for recruitment, randomization, and pragmatic data collection of baseline demographics, medications, and clinical outcomes using existing national clinical registries integrated with the trial database. The primary objective is to demonstrate noninferiority in terms of freedom from TLF (cardiovascular death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization) at 1 year. Powered secondary endpoints will be tested sequentially for superiority from 6 months to the end of follow-up (5 years) for the following: 1) TLF in all subjects, 2) target vessel failure in all subjects, and 3) TLF in subjects with acute coronary syndrome (ACS). Subsequent superiority testing will be performed at a time determined depending on the number of events, ensuring sufficient statistical power. Change in angina-related symptoms, function and quality of life will be assessed using the Seattle Angina Questionnaire-short version. Predefined sub-groups will be analyzed. In total, 2400 patients have been randomized at 20 sites in Sweden. Available baseline characteristic reveal relatively old age (68 years) and a large proportion of ACS patients including 25% STEMI and 37% NSTEMI patients. SUMMARY: The INFINITY-SWEDEHEART study is designed to evaluate the long-term safety and efficacy of the DynamX bioadaptor compared to the Resolute Onyx stent in a general PCI patient population.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Sistema de Registros , Sirolimo , Humanos , Sirolimo/farmacologia , Sirolimo/análogos & derivados , Método Simples-Cego , Intervenção Coronária Percutânea/métodos , Desenho de Prótese , Doença da Artéria Coronariana/terapia , Resultado do Tratamento , Masculino , Feminino , Implantes Absorvíveis
15.
Am Heart J ; 270: 13-22, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38253304

RESUMO

BACKGROUND: Safety and feasibility of transcatheter aortic valve replacement (TAVR) without balloon aortic valvuloplasty (BAV) using the SAPIEN 3 balloon-expandable device has been previously demonstrated. The impact on long-term valve hemodynamic performances and outcomes remains however unknown. We evaluate long-term clinical and hemodynamic results according to the implant strategy (direct TAVR vs BAV pre-TAVR) in patients included in the DIRECTAVI randomized trial (NCT02729519). METHODS: Clinical and echocardiographic follow-up until January 2023 was performed for all patients included in the DIRECTAVI trial since 2016 (n = 228). The primary endpoint was incidence of moderate/severe hemodynamic valve deterioration (HVD), according to the Valve Academic Research defined Consortium-3 criteria (increase in mean gradient ≥10 mmHg resulting in a final mean gradient ≥20 mmHg, or new/worsening aortic regurgitation of 1 grade resulting in ≥ moderate aortic regurgitation). RESULTS: Median follow-up was 3.8 (2.2-4.7) years. Mean age at follow-up was 87 ± 6.7 years. No difference in incidence of HVD in the direct implantation group compared to the BAV group was found (incidence of 1.97 per 100 person-years and 1.45 per 100 person-years, respectively, P = 0.6). Prevalence of predicted prothesis-patient mismatch was low (n = 13 [11.4%] in the direct TAVR group vs n = 15 [13.2%] in BAV group) and similar between both groups (P = .7). Major outcomes including death, stroke, hospitalization for heart failure and pacemaker implantation were similar between both groups, (P = .4, P = .7, P = .3, and P = .3 respectively). CONCLUSION: Direct implantation of the balloon-expandable device in TAVR was not associated with an increased risk of moderate/severe HVD or major outcomes up to 6-year follow-up. These results guarantee wide use of direct balloon-expandable valve implantation, when feasible. CLINICAL TRIALS REGISTRATION NUMBER: NCT05140317.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Seguimentos , Insuficiência da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Tempo , Desenho de Prótese , Valvuloplastia com Balão/efeitos adversos
16.
Am Heart J ; 275: 21-34, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38815781

RESUMO

Tricuspid regurgitation (TR) is common and associated with significant mortality and morbidity. Because the effectiveness and safety of medical and surgical treatments are limited, there is a significant unmet need for the treatment of this disease. Therefore, there is a growing market for percutaneous devices that offer safer, less invasive, and more effective treatment options in this patient population. On February 13, 2024, the US Food and Drug Administration (FDA) convened a meeting of the Circulatory System Devices Panel to discuss the safety and effectiveness of the TriClip Transcatheter Valve Repair System (Abbott, Santa Clara, CA, USA). Several important points were discussed, including newly published data from the TRILUMINATE Pivotal study, the use of patient-oriented outcomes for device approval, and a discussion about training requirements and rollout plans when approving a breakthrough device. In this manuscript, we summarize the data presented by the sponsor and FDA and describe the deliberations and discussions during the meeting.


Assuntos
Cateterismo Cardíaco , Aprovação de Equipamentos , Insuficiência da Valva Tricúspide , Valva Tricúspide , United States Food and Drug Administration , Humanos , Comitês Consultivos , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Desenho de Prótese , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Estados Unidos
17.
Am Heart J ; 274: 65-74, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38701961

RESUMO

BACKGROUND: There has not been a consensus on the prothesis sizing strategy in type 0 bicuspid aortic stenosis (AS) patients undergoing transcatheter aortic valve replacement (TAVR). Modifications to standard annular sizing strategies might be required due to the distinct anatomical characteristics. We have devised a downsizing strategy for TAVR using a self-expanding valve specifically for patients with type 0 bicuspid AS. The primary aim of this study is to compare the safety and efficacy of downsizing strategy with the Standard Annulus Sizing Strategy in TAVR for patients with type 0 bicuspid AS. TRIAL DESIGN: It is a prospective, multi-center, superiority, single-blinded, randomized controlled trial comparing the Down Sizing and Standard Annulus Sizing Strategy in patients with type 0 bicuspid aortic stenosis undergoing transcatheter aortic valve replacement. Eligible participants will include patients with severe type 0 bicuspid AS, as defined by criteria such as mean gradient across aortic valve ≥40 mmHg, peak aortic jet velocity ≥4.0 m/s, aortic valve area (AVA) ≤1.0 cm², or AVA index ≤0.6 cm2/m2. These patients will be randomly assigned, in a 1:1 ratio, to either the Down Sizing Strategy group or the Standard Sizing Strategy group. In the Down Sizing Strategy group, a valve one size smaller will be implanted if the "waist sign" manifests along with less than mild regurgitation during balloon pre-dilatation. The primary end point of the study is a composite of VARC-3 defined device success, absence of both permanent pacemaker implantation due to high-degree atrioventricular block and new-onset complete left bundle branch block. CONCLUSION: This study will compare the safety and efficacy of Down Sizing Strategy with the Standard Annulus Sizing Strategy and provide valuable insights into the optimal approach for sizing in TAVR patients with type 0 bicuspid AS. We hypothesize that the Down Sizing Strategy will demonstrate superiority when compared to the Standard Annulus Sizing Strategy. (Down Sizing Strategy (HANGZHOU Solution) vs Standard Sizing Strategy TAVR in Bicuspid Aortic Stenosis (Type 0) (TAILOR-TAVR), NCT05511792).


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/complicações , Estudos Prospectivos , Método Simples-Cego , Substituição da Valva Aórtica Transcateter/métodos
18.
Am Heart J ; 276: 70-82, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39032585

RESUMO

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) is uncertain. This study was performed to investigate the risk of all-cause mortality, heart failure hospitalization, and aortic valve reintervention in patients with and without predicted PPM after TAVR. METHODS: This nationwide, population-based cohort study included all patients who underwent transfemoral primary TAVR in Sweden from 2008 to 2022 in the SWEDEHEART register. PPM was defined according to published effective orifice areas for each valve model and size. The patients were divided into those with and without PPM. Additional baseline characteristics and outcome data were obtained from other national health data registers. Regression standardization was used to adjust for intergroup differences. RESULTS: Of 8485 patients, 7879 (93%) had no PPM and 606 (7%) had PPM. The crude cumulative incidence of all-cause mortality at 1, 5, and 10 years in patients with versus without PPM was 7% versus 9%, 40% versus 44%, and 80% versus 85%, respectively. After regression standardization, there was no between-group difference in long-term mortality, and the absolute difference at 10 years was 1.5% (95% confidence interval, -2.9%-6.0%). The mean follow-up was 3.0 years (maximum, 14 years). There was no difference in the risk of heart failure hospitalization or aortic valve reintervention. CONCLUSIONS: The risk of all-cause mortality, heart failure hospitalization, or aortic valve reintervention was not higher in patients with than without predicted PPM following TAVR. Furthermore, PPM was present in only 7% of patients, and severe PPM was almost nonexistent.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Suécia/epidemiologia , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Idoso , Insuficiência Cardíaca , Sistema de Registros , Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Reoperação/estatística & dados numéricos , Causas de Morte , Fatores de Risco , Desenho de Prótese
19.
Am Heart J ; 275: 128-137, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38838970

RESUMO

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, P = .33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 P = .46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, P = .04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, P = .02), reduced SVi (34.2 vs 38 mL/m2, P < .01) and transaortic flow rate (190.6 vs 211 mL/s, P < .01). At predischarge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, P < .01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, P = .03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs 44 IQR 35-59 in those without, P = .02)). No evidence of a significant impact of PPM on overall (P = .71) and CV (P = .70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, P = .03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, P < .001) and LVOT diameter (OR 0.79, 0.65-0.95, P = .01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.


Assuntos
Estenose da Valva Aórtica , Ecocardiografia , Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas/efeitos adversos , Ecocardiografia/métodos , Estenose da Valva Aórtica/cirurgia , Idoso , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Ajuste de Prótese
20.
Am Heart J ; 271: 76-83, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38412895

RESUMO

BACKGROUND: Previous studies primarily demonstrated that transfemoral transcatheter aortic valve replacement (TAVR) with self-expanding valve appeared to be a safe and feasible treatment for patients with pure native aortic regurgitation (AR). However, the routine application of transfemoral TAVR for pure AR patients lacks support from randomized trials. TRIAL DESIGN: SEASON-AR trial is a prospective, multicenter, randomized, controlled, parallel-group, open-label trial, involving at least 20 sites in China, aiming to enroll 210 patients with pure native severe AR and high surgical risk. All enrolled patients are randomly assigned in a 1:1 fashion to undergo transfemoral TAVR with VitaFlowTM valve and receive guideline-directed medical therapy (GDMT) or to receive GDMT alone. The primary endpoint is the rate of major adverse cardiac events (MACE) at 12 months after the procedure, defined by the composite of all-cause mortality, disabling stroke, and rehospitalization for heart failure. The major secondary endpoints encompass various measures, including procedure-related complications, device success, 6-minute walk distance, and the occurrence of each individual component of the primary endpoint. After hospital discharge, follow-up was conducted through clinical visits or telephone contact at 1, 6, and 12 months. The follow-up will continue annually until 5 years after the index procedure to assess the long-term outcomes. CONCLUSION: SEASON-AR trial is the first study designed to investigate the clinical efficacy and safety of transfemoral TAVR with a self-expanding valve in patients with pure native severe AR with inoperable or high-risk, as compared to medical treatment only.


Assuntos
Insuficiência da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/epidemiologia , Estudos Prospectivos , Masculino , Feminino , Idoso , Artéria Femoral , Valva Aórtica/cirurgia , Desenho de Prótese , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , China/epidemiologia , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa