Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Ultrasound Obstet Gynecol ; 58(6): 853-863, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34096674

RESUMO

OBJECTIVES: The primary aim of this study was to evaluate the feasibility of automated measurement of fetal atrioventricular (AV) plane displacement (AVPD) over several cardiac cycles using myocardial velocity traces obtained by color tissue Doppler imaging (cTDI). The secondary objectives were to establish reference ranges for AVPD during the second half of normal pregnancy, to assess fetal AVPD in prolonged pregnancy in relation to adverse perinatal outcome and to evaluate AVPD in fetuses with a suspicion of intrauterine growth restriction (IUGR). METHODS: The population used to develop the reference ranges consisted of women with an uncomplicated singleton pregnancy at 18-42 weeks of gestation (n = 201). The prolonged-pregnancy group comprised women with an uncomplicated singleton pregnancy at ≥ 41 + 0 weeks of gestation (n = 107). The third study cohort comprised women with a singleton pregnancy and suspicion of IUGR, defined as an estimated fetal weight < 2.5th centile or an estimated fetal weight < 10th centile and umbilical artery pulsatility index > 97.5th centile (n = 35). Cineloops of the four-chamber view of the fetal heart were recorded using cTDI. Regions of interest were placed at the AV plane in the left and right ventricular walls and the interventricular septum, and myocardial velocity traces were integrated and analyzed using an automated algorithm developed in-house to obtain mitral (MAPSE), tricuspid (TAPSE) and septal (SAPSE) annular plane systolic excursion. Gestational-age specific reference ranges were constructed and normalized for cardiac size. The correlation between AVPD measurements obtained using cTDI and those obtained by anatomic M-mode were evaluated, and agreement between these two methods was assessed using Bland-Altman analysis. The mean Z-scores of fetal AVPD in the cohort of prolonged pregnancies were compared between cases with normal and those with adverse outcome using Mann-Whitney U-test. The mean Z-scores of fetal AVPD in IUGR fetuses were compared with those in the normal reference population using Mann-Whitney U-test. Inter- and intraobserver variability for acquisition of cTDI recordings and offline analysis was assessed by calculating coefficients of variation (CV) using the root mean square method. RESULTS: Fetal MAPSE, SAPSE and TAPSE increased with gestational age but did not change significantly when normalized for cardiac size. The fitted mean was highest for TAPSE throughout the second half of gestation, followed by SAPSE and MAPSE. There was a significant correlation between MAPSE (r = 0.64; P < 0.001), SAPSE (r = 0.72; P < 0.001) and TAPSE (r = 0.84; P < 0.001) measurements obtained by M-mode and those obtained by cTDI. The geometric means of ratios between AVPD measured by cTDI and by M-mode were 1.38 (95% limits of agreement (LoA), 0.84-2.25) for MAPSE, 1.00 (95% LoA, 0.72-1.40) for SAPSE and 1.20 (95% LoA, 0.92-1.57) for TAPSE. In the prolonged-pregnancy group, the mean ± SD Z-scores for MAPSE (0.14 ± 0.97), SAPSE (0.09 ± 1.02) and TAPSE (0.15 ± 0.90) did not show any significant difference compared to the reference ranges. Twenty-one of the 107 (19.6%) prolonged pregnancies had adverse perinatal outcome. The AVPD Z-scores were not significantly different between pregnancies with normal and those with adverse outcome in the prolonged-pregnancy cohort. The mean ± SD Z-scores for SAPSE (-0.62 ± 1.07; P = 0.006) and TAPSE (-0.60 ± 0.89; P = 0.002) were significantly lower in the IUGR group compared to those in the normal reference population, but the differences were not significant when the values were corrected for cardiac size. The interobserver CVs for the automated measurement of MAPSE, SAPSE and TAPSE were 28.1%, 17.7% and 15.3%, respectively, and the respective intraobserver CVs were 33.5%, 15.0% and 17.9%. CONCLUSIONS: This study showed that fetal AVPD can be measured automatically by integrating cTDI velocities over several cardiac cycles. Automated analysis of AVPD could potentially help gather larger datasets to facilitate use of machine-learning models to study fetal cardiac function. The gestational-age associated increase in AVPD is most likely a result of increasing cardiac size, as the AVPD normalized for cardiac size did not change significantly between 18 and 42 weeks. A decrease was seen in TAPSE and SAPSE in IUGR fetuses, but not after correction for cardiac size. © 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Nó Atrioventricular/diagnóstico por imagem , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Coração Fetal/diagnóstico por imagem , Sístole/fisiologia , Ultrassonografia Pré-Natal/estatística & dados numéricos , Nó Atrioventricular/embriologia , Velocidade do Fluxo Sanguíneo , Estudos de Viabilidade , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Retardo do Crescimento Fetal/fisiopatologia , Coração Fetal/embriologia , Peso Fetal , Idade Gestacional , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/embriologia , Humanos , Gravidez , Fluxo Pulsátil , Valores de Referência , Volume Sistólico , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/embriologia , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/embriologia
2.
Cardiovasc Ultrasound ; 12: 48, 2014 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-25422167

RESUMO

BACKGROUND: Carotid Duplex Ultrasonography (CDUS) is one of the non-invasive imaging modalities used to evaluate for carotid artery stenosis. However, it is often used in patients with coronary artery disease (CAD), peripheral artery disease (PAD), before heart surgery, syncope and non-specific neurological symptoms although its value is unclear. Our study aimed to further investigate the yield of CDUS in these conditions. METHODS: A retrospective analysis was conducted on 827 consecutive carotid ultrasounds ordered between March 2013 and August 2013 at Newark Beth Israel Medical Center. Clinical characteristics such as age, sex, smoking status, systemic hypertension, diabetes mellitus, CAD, PAD, carotid bruit and indications for carotid ultrasound were included. Significant cerebrovascular disease (sCBVD) was defined as greater than or equal to 50% diameter reduction in internal carotid arteries (ICA) or any degree of occlusion in vertebrobasilar system. RESULTS: Only 88 out of 827 (10.6%) patients had sCBVD. Using logistic regression analysis we identified age greater than 65 years (OR 2.1, 95% CI 1.2 to 3.7; P=0.006), carotid bruit (OR 7.8, 95% CI 3.6 to 16.6; P <0.001) and history of prior carotid endarterectomy or carotid artery stenting (OR 5.8, 95% CI 2.3 to 14.8; P <0.001) as significant predictors of sCBVD. CONCLUSIONS: Significant carotid artery stenosis is more likely in patients 65 years and older, presence of carotid bruit and prior CEA. On the other hand, it has low diagnostic yield in less than 65-year-old individuals, syncope and non-focal neurological symptoms. This highlights the need for better risk prediction models in order to promote optimal utilization.


Assuntos
Espessura Intima-Media Carotídea/estatística & dados numéricos , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/epidemiologia , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Hospitais Gerais/estatística & dados numéricos , População Urbana/estatística & dados numéricos , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , New Jersey/epidemiologia , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Distribuição por Sexo
3.
J Cardiothorac Vasc Anesth ; 28(5): 1198-202, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24447502

RESUMO

OBJECTIVES: The primary objective of this study was to establish the relationship among tricuspid annular velocity (S'), tricuspid annular plane systolic excursion (TAPSE), and stroke volume (SV) in a cardiac surgical population with and without right ventricular (RV) dysfunction. The secondary objective was to assess the effect of ephedrine on these relationships in a population without RV dysfunction. DESIGN: Prospective, nonrandomized, unblinded study. SETTING: Single tertiary-level, university-affiliated hospital. PARTICIPANTS: Twenty-seven patients undergoing elective coronary artery bypass grafting with no evidence of RV dysfunction (Group 1). Sixteen ventilated postcardiac surgical patients with suspected RV dysfunction (Group 2). INTERVENTIONS: Ten mg of intravenous ephedrine to Group 1 only. MEASUREMENTS AND MAIN RESULTS: Using transthoracic echocardiography, S' and TAPSE were measured using color tissue Doppler applied at the RV base in a 4-chamber view. SV was calculated using thermodilution. Six patients in Group 1 and 6 patients in Group 2 were excluded because of poor imaging or ineligibility. Modest correlation was found between TAPSE and SV in Group 1 (R = 0.50, p<0.001). There was no correlation between TAPSE and SV in Group 2. There was no correlation between S' and SV in both groups. In Group 1, the relationship between TAPSE and S' was curvilinear (R = 0.74 pre-ephedrine, p<0.001; R = 0.64, p = 0.009 post-ephedrine). There was no relationship between TAPSE and S' in Group 2. Ephedrine increased S' and TAPSE. The TAPSE-S' relationship was not significantly altered. CONCLUSIONS: In the presence of RV dysfunction, TAPSE did not correlate with cardiac output. In the absence of RV dysfunction, the relationship between TAPSE and S' described a curvilinear relationship.


Assuntos
Ecocardiografia Doppler em Cores/estatística & dados numéricos , Ecocardiografia/estatística & dados numéricos , Volume Sistólico/fisiologia , Valva Tricúspide/fisiologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/cirurgia , Idoso , Procedimentos Cirúrgicos Cardíacos , Ponte de Artéria Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Disfunção Ventricular Direita/fisiopatologia
4.
J Cardiothorac Vasc Anesth ; 28(5): 1184-90, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25104081

RESUMO

OBJECTIVE: The authors hypothesized that the clinical profile of patients undergoing hTEE after continuous flow left ventricular assist device (CF-LVAD) implant would be in patients with greater acuity, more blood product utilization, and longer length of ICU stay, and that hTEE would change clinical management. DESIGN: Retrospective review. SETTING: University hospital. PARTICIPANTS: One hundred consecutive patients receiving a CF-LVAD. INTERVENTIONS: Retrospective review using a standardized electronic form of a miniaturized disposable transesophageal echocardiography probe that documented not only physical findings but also changes in hemodynamic management (hTEE) in CF-LVAD patients. MEASUREMENTS AND MAIN RESULTS: Of the 100 patients, 41 received an hTEE probe. The INTERMACS score, Leitz-Miller Score, and Kormos score indicated the hTEE group had a statistically significant greater risk of morbidity and mortality. Interoperatively, the hTEE group received more blood products and was more likely to have an open chest. Postoperatively, the hTEE group received more blood products, had a longer total length of stay, and had increased mortality. ICU length of stay, days on inotropes and days on mechanical ventilation were not statistically significant between the 2 groups. Information obtained from hTEE changed ICU management in 72% of studies. CONCLUSION: Retrospective review of CF-LVAD patients revealed that postoperative hTEE is used in sicker CF-LVAD patients and frequently leads to changes in ICU clinical management.


Assuntos
Ecocardiografia Doppler em Cores/estatística & dados numéricos , Ecocardiografia Transesofagiana/estatística & dados numéricos , Coração Auxiliar , Hemodinâmica/fisiologia , Cuidados Pós-Operatórios/métodos , Adulto , Idoso , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/mortalidade , Doenças Cardiovasculares/cirurgia , Estudos de Coortes , Ecocardiografia Doppler em Cores/mortalidade , Ecocardiografia Transesofagiana/mortalidade , Feminino , Ventrículos do Coração , Humanos , Tempo de Internação/tendências , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/mortalidade , Estudos Retrospectivos
5.
AJR Am J Roentgenol ; 200(5): W444-9, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23617512

RESUMO

OBJECTIVE: Testicular torsion is a common acute condition in boys requiring prompt accurate management. The objective of this article was to evaluate ultrasound accuracy, findings, and clinical predictors in testicular torsion in boys presenting to the Stollery pediatric emergency department with acute scrotal pain. METHODS: Retrospective review of surgical and emergency department ultrasound records for boys from 1 month to 17 years old presenting with acute scrotal pain from 2008 to 2011 was performed. Clinical symptoms, ultrasound and surgical findings, and diagnoses were recorded. Surgical results and follow-up were used as the reference standard. RESULTS: Of 342 patients who presented to the emergency department with acute scrotum, 35 had testicular torsion. Of 266 ultrasound examinations performed, 29 boys had torsion confirmed by surgery. The false-positive rate for ultrasound was 2.6%, and there were no false-negative findings. Mean times from presentation at the emergency department to ultrasound and surgery were 209.4 and 309.4 minutes, respectively. Of the torsed testicles, 69% were salvageable. Sensitivity, specificity, and diagnostic accuracy of ultrasound for testicular torsion were 100%, 97.9%, and 98.1%, respectively. Sonographic heterogeneity was seen in 80% of nonviable testes at surgery and 58% of patients with viable testes (p = 0.41). Sudden-onset scrotal pain (88%), abnormal position (86%), and absent cremasteric reflex (91%) were most prevalent in torsion patients. CONCLUSION: Color Doppler ultrasound is accurate and sensitive for diagnosis of torsion in the setting of acute scrotum. Despite heterogeneity on preoperative ultrasound, many testes were considered to be salvageable at surgery. The salvage rate of torsed testes was high.


Assuntos
Abdome Agudo/diagnóstico por imagem , Abdome Agudo/cirurgia , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Escroto/diagnóstico por imagem , Escroto/cirurgia , Torção do Cordão Espermático/diagnóstico por imagem , Torção do Cordão Espermático/cirurgia , Abdome Agudo/epidemiologia , Adolescente , Alberta/epidemiologia , Causalidade , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Masculino , Prevalência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Torção do Cordão Espermático/epidemiologia , Resultado do Tratamento
6.
J Ultrasound Med ; 32(7): 1227-32, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23804345

RESUMO

OBJECTIVES: This study aimed to establish reference ranges for Doppler parameters of the fetal dorsalis pedis artery and to compare them with those of the anterior tibial artery. METHODS: Dorsalis pedis artery velocimetry was performed in 138 singleton fetuses. Intraobserver repeatability coefficients and differences between measurements of bilateral legs were also evaluated. Comparisons were made between the pulsatility index in the dorsalis pedis and anterior tibial arteries. RESULTS: The average maximum velocity of the dorsalis pedis artery increased from approximately 12.2 cm/s at 18 weeks' gestation to 33.6 cm/s at 39 weeks' gestation, whereas the minimum velocity did not show any significant variation during the observed gestational weeks. The average pulsatility index increased from about 2.0 at 18 weeks' gestation to 3.1 at 39 weeks' gestation. The pulsatility index was lower in the dorsalis pedis artery than in the anterior tibial artery. CONCLUSIONS: Doppler parameters of the dorsalis pedis artery can be easily and accurately acquired by trained examiners and therefore are potential means for evaluating related fetal vascular development. However, it is still unclear whether changes exist in fetuses with limb diseases, and further investigation is needed.


Assuntos
Artérias/embriologia , Artérias/fisiologia , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Pé/irrigação sanguínea , Pé/embriologia , Segundo Trimestre da Gravidez/psicologia , Terceiro Trimestre da Gravidez/fisiologia , Fluxo Pulsátil/fisiologia , Artérias/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , China/epidemiologia , Feminino , Humanos , Masculino , Gravidez , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
J Ultrasound Med ; 32(11): 1969-78, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24154901

RESUMO

OBJECTIVES: The purpose of this study was to calculate a number of thyroid grayscale and Doppler sonographic parameters in healthy individuals and patients with Hashimoto thyroiditis or Graves disease and assess their sensitivity and specificity for the diagnosis of autoimmune thyroid disease using receiver operating characteristic curves. METHODS: A consecutive series of 153 patients (70 euthyroid and 54 hypothyroid patients with Hashimoto thyroiditis and 29 patients with Graves disease), all selected from an outpatient endocrine clinic, and 48 age- and sex-matched healthy control participants were evaluated with grayscale and power Doppler sonography. RESULTS: An irregular echo pattern in the thyroid parenchyma had 92.8% sensitivity for the diagnosis of autoimmune thyroid disease, and a left inferior thyroid artery peak systolic velocity (PSV) greater than 26.11 cm/s had 91.7% specificity. Of 8 patients with Hashimoto thyroiditis and normal grayscale sonographic characteristics, 6 had a left inferior thyroid artery PSV greater than 26.11 cm/s. A left inferior thyroid artery PSV greater than 61.65 cm/s had 82.8% sensitivity and 86.9% specificity for differentiating Hashimoto thyroiditis from Graves disease. CONCLUSIONS: The left inferior thyroid artery PSV was the most accurate sonographic parameter for the diagnosis of autoimmune thyroid disease. Measurement of the inferior thyroid artery PSV could be used in patients with a normal grayscale sonographic appearance and inconclusive clinical and biochemical parameters to substantiate the diagnosis of autoimmune thyroid disease. Further studies are needed to evaluate and expand the use of this index.


Assuntos
Ecocardiografia Doppler em Cores/estatística & dados numéricos , Doença de Graves/diagnóstico por imagem , Doença de Graves/fisiopatologia , Doença de Hashimoto/diagnóstico por imagem , Doença de Hashimoto/fisiopatologia , Glândula Tireoide/irrigação sanguínea , Glândula Tireoide/diagnóstico por imagem , Adulto , Velocidade do Fluxo Sanguíneo , Diagnóstico Diferencial , Ecocardiografia Doppler em Cores/métodos , Doença de Graves/epidemiologia , Grécia/epidemiologia , Doença de Hashimoto/epidemiologia , Humanos , Masculino , Prevalência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sístole
8.
Comput Math Methods Med ; 2022: 1310841, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35126616

RESUMO

This study was to investigate the value of echocardiographic data in assessing changes in cardiac function before and after transcatheter closure in children and adult patients with patent ductus arteriosus (PDA). In this study, 150 patients with isolated PDA treated by cardiac catheterization and transcatheter closure were selected as the study sample. Real-time color Doppler echocardiography was used both after and after operation. The results showed that the left ventricle returned to normal in 75 patients one day after operation, with an average age of 10.95 ± 3.27 years; the left ventricle did not return to normal in 10 patients 360 days after operation, with an average age of 64.31 ± 7.05 years. Left ventricular end diastolic volume index (LVEDVI) and left ventricular end systolic volume index (LVESVI) of patients decreased significantly one day after operation and remained at 51.95 ± 9.55 mL/m2 and 20.36 ± 8.11 mL/m-2, respectively. In summary, echocardiographic data have a high reference value in assessing cardiac function characteristics in children and adult patients with PDA and are worthy of further promotion.


Assuntos
Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/cirurgia , Ecocardiografia/métodos , Adolescente , Adulto , Idoso , Fenômenos Fisiológicos Cardiovasculares , Criança , Biologia Computacional , Permeabilidade do Canal Arterial/fisiopatologia , Ecocardiografia/estatística & dados numéricos , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Feminino , Testes de Função Cardíaca , Sopros Cardíacos/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Dispositivos de Oclusão Vascular , Função Ventricular Esquerda , Adulto Jovem
9.
Comput Math Methods Med ; 2022: 5019153, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35126627

RESUMO

The research was aimed at analyzing the value of the optimized eXtreme Gradient Boosting (XGBoost) algorithm-based ultrasound cardiogram images in the diagnosis of pregnant hypertension patients. A total of 145 pregnant women (85 cases suffered from hypertension disease during pregnancy and 60 other normal women were healthy) were selected as the reference to the comparison and analysis of ultrasound cardiac function parameter, common carotid artery parameter, and the coupling relationship between hearts and cervical vessels of pregnant hypertension patients. The results demonstrated ultrasound cardiac function parameter of pregnant hypertension patients as follows. The maximum volume of the left atrium (LAVmax) was 35.65 mm, left ventricular end-systolic volume (LVESV) was 31.07 mm, and left ventricular end-diastolic volume (LVEDV) was 88.73 mm. All the above indexes were obviously higher than those of the normal control group (P < 0.05). Besides, intima-media thickness (IMT) of common carotid artery (465.84 µm), pulse wave velocity (PWV) (8.09 m/s), pressure of turning point 1 from isovolumic contraction phase to ejection phase (PT1) (126.5 mmHg), arterial enhancement pressure (AP) (6.14 mmHg), and arterial pressure enhancement index (8.58%) were all significantly higher than those of the normal control group (P < 0.05). In addition, the correlation between the coupling (E/A) of hearts and carotid artery of pregnant hypertension patients and PWV was not obvious (r = -0.08432, P > 0.05). The results of the research indicated that intima-media inside carotid artery of pregnant hypertension patients thickened obviously, and it became less elastic compared with that of normal healthy pregnant women. What is more, cardiac morphological changes were manifested mainly as the enlargement of the left atrial chamber and the thickening of the interventricular septum. Volume load and blood flow velocity both increased, and left ventricular diastolic function was damaged. XGBoost algorithm-based ultrasound cardiogram images could improve the diagnostic effects of hypertension during pregnancy effectively.


Assuntos
Algoritmos , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Hipertensão/complicações , Hipertensão/diagnóstico por imagem , Complicações Cardiovasculares na Gravidez/diagnóstico por imagem , Adulto , Inteligência Artificial , Velocidade do Fluxo Sanguíneo , Volume Sanguíneo , Espessura Intima-Media Carotídea , Estudos de Casos e Controles , Biologia Computacional , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Hipertensão/fisiopatologia , Gravidez , Complicações Cardiovasculares na Gravidez/fisiopatologia , Função Ventricular Esquerda , Septo Interventricular/diagnóstico por imagem , Adulto Jovem
10.
Comput Math Methods Med ; 2021: 2602688, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34552659

RESUMO

Accurate assessment of mitral regurgitation (MR) severity is critical in clinical diagnosis and treatment. No single echocardiographic method has been recommended for MR quantification thus far. We sought to define the feasibility and accuracy of the mask regions with a convolutional neural network (Mask R-CNN) algorithm in the automatic qualitative evaluation of MR using color Doppler echocardiography images. The authors collected 1132 cases of MR from hospital A and 295 cases of MR from hospital B and divided them into the following four types according to the 2017 American Society of Echocardiography (ASE) guidelines: grade I (mild), grade II (moderate), grade III (moderate), and grade IV (severe). Both grade II and grade III are moderate. After image marking with the LabelMe software, a method using the Mask R-CNN algorithm based on deep learning (DL) was used to evaluate MR severity. We used the data from hospital A to build the artificial intelligence (AI) model and conduct internal verification, and we used the data from hospital B for external verification. According to severity, the accuracy of classification was 0.90, 0.89, and 0.91 for mild, moderate, and severe MR, respectively. The Macro F1 and Micro F1 coefficients were 0.91 and 0.92, respectively. According to grading, the accuracy of classification was 0.90, 0.87, 0.81, and 0.91 for grade I, grade II, grade III, and grade IV, respectively. The Macro F1 and Micro F1 coefficients were 0.89 and 0.89, respectively. Automatic assessment of MR severity is feasible with the Mask R-CNN algorithm and color Doppler electrocardiography images collected in accordance with the 2017 ASE guidelines, and the model demonstrates reasonable performance and provides reliable qualitative results for MR severity.


Assuntos
Algoritmos , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Insuficiência da Valva Mitral/diagnóstico por imagem , Redes Neurais de Computação , Adulto , Idoso , Idoso de 80 Anos ou mais , Biologia Computacional , Aprendizado Profundo , Ecocardiografia Tridimensional/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
11.
Medicine (Baltimore) ; 100(12): e25229, 2021 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-33761712

RESUMO

ABSTRACT: This study aimed to explore the relationship between H558R polymorphism of the SCN5A gene and atrial fibrillation (AF) in Tibetan and Han nationalities at high altitude.A total of 50 Tibetan and 50 Han patients with AF at the same altitude (2260 m) were included. Meanwhile, the general clinical data of patients without AF (50 Tibetan and 50 Han) matched with the data of patients with AF were included during the same period. The blood samples of patients were collected to extract DNA. The DNA sequencing was performed by Xi'an Zhenpin Biotechnology Co., Ltd. The mutation loci of the sequence were located and identified by DNA sequencing. The general information, laboratory examination, color Doppler echocardiography, and genotypes and alleles of each group were analyzed. The multivariate logistic regression analysis was used to determine the independent risk factors for AF.The genotype and allele frequencies of the H558R locus of the SCN5A gene in the AF groups of Tibetan and Han nationalities were significantly different from those in the non-AF groups (P < .05). The genotype and allele frequency of the H558R locus of the SCN5A gene in the AF group of Tibetan nationalities were not significantly different from those in the AF group of Han nationalities (P > .05). The logistic regression analysis of the total population revealed that coronary heart disease, age, total cholesterol (TC), left atrial diameter, and G allele were independent risk factors for AF occurrence.The occurrence of AF in Tibetan and Han nationalities at high altitude is associated with the polymorphism of H558R locus of the SCN5A gene. The G allele is an independent risk factor for the occurrence of AF in Tibetan and Han nationalities.


Assuntos
Altitude , Fibrilação Atrial/genética , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etnologia , Fibrilação Atrial/fisiopatologia , China/epidemiologia , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Feminino , Predisposição Genética para Doença , Humanos , Masculino , Pessoa de Meia-Idade , Polimorfismo de Nucleotídeo Único , Tibet/epidemiologia
12.
J Am Heart Assoc ; 10(1): e018816, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33372529

RESUMO

Background Although women represent half of the population burden of aortic stenosis (AS), little is known whether sex affects the presentation, management, and outcome of patients with AS. Methods and Results In a cohort of 2429 patients with severe AS (49.5% women) we aimed to evaluate 5-year excess mortality and performance of aortic valve replacement (AVR) stratified by sex. At presentation, women were older (P<0.001), with less comorbidities (P=0.030) and more often symptomatic (P=0.007) than men. Women had smaller aortic valve area (P<0.001) than men but similar mean transaortic pressure gradient (P=0.18). The 5-year survival was lower compared with expected survival, especially for women (62±2% versus 71% for women and 69±1% versus 71% for men). Despite longer life expectancy in women than men, women had lower 5-year survival than men (66±2% [expected-75%] versus 68±2% [expected-70%], P<0.001) after matching for age. Overall, 5-year AVR incidence was 79±2% for men versus 70±2% for women (P<0.001) with male sex being independently associated with more frequent early AVR performance (odds ratio, 1.49; 1.18-1.97). After age matching, women remained more often symptomatic (P=0.004) but also displayed lower AVR use (64.4% versus 69.1%; P=0.018). Conclusions Women with severe AS are diagnosed at later ages and have more symptoms than men. Despite prevalent symptoms, AVR is less often performed in women and 5-year excess mortality is noted in women versus men, even after age matching. These imbalances should be addressed to ensure that both sexes receive equivalent care for severe AS.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Ecocardiografia Doppler em Cores , Expectativa de Vida , Medição de Risco , Fatores Sexuais , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Fatores Etários , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Comorbidade , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Feminino , França/epidemiologia , Humanos , Masculino , Mortalidade , Tamanho do Órgão , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Índice de Gravidade de Doença
13.
Echocardiography ; 27(4): 448-53, 2010 04.
Artigo em Inglês | MEDLINE | ID: mdl-20345448

RESUMO

OBJECTIVES: It is fairly easy to detect advanced valve lesions of established rheumatic heart disease by echocardiography in the clinically identified cases of rheumatic heart disease. However, to diagnose a subclinical case of rheumatic heart disease, no uniform set of echocardiographic criteria exist. Moderate thickening of valve leaflets is considered an indicator of established rheumatic heart disease. World Health Organization criteria for diagnosing probable rheumatic heart disease are more sensitive and are based on the detection of significant regurgitation of mitral and/or aortic valves by color Doppler. We attempted diagnosing RHD in school children in Bikaner city by cardiac ultrasound. METHODS: The stratified cluster sampling technique was employed to identify 31 random clusters in the coeducational schools of Bikaner city. We selected 1059 school children aged 6-15 years from these schools. An experienced operator did careful cardiac auscultation and echocardiographic study. A second expert confirmed the echocardiographic findings. FINDINGS: The prevalence of lesions suggestive of rheumatic heart disease by echocardiography was 51 per 1,000 (denominator = 1059; 95% CI: 38-64 per 1,000). We were able to clinically diagnose RHD in one child. None of these children or their parents having echocardiographic evidence of RHD could provide a positive history of acute rheumatic fever. CONCLUSIONS: By echocardiographic screening, we found a high prevalence of rheumatic heart disease in the surveyed population. Clinical auscultation had much lower diagnostic efficacy.


Assuntos
Ecocardiografia Doppler em Cores/métodos , Cardiopatia Reumática/diagnóstico por imagem , Cardiopatia Reumática/epidemiologia , Adolescente , Distribuição por Idade , Causalidade , Criança , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Feminino , Humanos , Índia/epidemiologia , Masculino , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/epidemiologia , Prevalência
14.
J Am Coll Cardiol ; 75(16): 1897-1909, 2020 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-32327100

RESUMO

BACKGROUND: The respective impacts of transvalvular flow, gradient, sex, and their interactions on mortality in patients with severe aortic stenosis undergoing surgical aortic valve replacement (AVR) are unknown. OBJECTIVES: This study sought to compare the impact of pre-operative flow-gradient patterns on mortality after AVR and to examine whether there are sex differences. METHODS: This study analyzed clinical, echocardiographic, and outcome data prospectively collected in 1,490 patients (544 women [37%]), with severe aortic stenosis and preserved left ventricular ejection fraction who underwent AVR. RESULTS: In this cohort, 601 patients (40%) had normal flow (NF) with high gradient (HG), 405 (27%) NF with low gradient (LG), 246 (17%) paradoxical low flow (LF)/HG, and 238 (16%) LF/LG. During a median follow-up of 2.42 years (interquartile range: 1.04 to 4.29 years), 167 patients died. Patients with LF/HG exhibited the highest mortality after AVR (hazard ratio [HR]: 2.01; 95% confidence interval [CI]: 1.33 to 3.03; p < 0.01), which remained significant after multivariate adjustment (HR: 1.96; 95% CI: 1.29 to 2.98; p < 0.01). Both LF/LG and NF/LG patients had comparable outcome to NF/HG (p ≥ 0.47). Optimal thresholds of stroke volume index were obtained for men (40 ml/m2) and women (32 ml/m2). Using these sex-specific cutpoints, paradoxical LF was independently associated with increased mortality in both women (adjusted HR: 2.05; 95% CI: 1.21 to 3.47; p < 0.01) and men (adjusted HR: 1.54; 95% CI: 1.02 to 2.32; p = 0.042), whereas guidelines' threshold (35 ml/m2) does not. CONCLUSIONS: Paradoxical LF/HG was associated with higher mortality following AVR, suggesting that a reduced flow is a marker of disease severity even in patients with HG aortic stenosis. Early surgical AVR (i.e., before gradient attains 40 mm Hg) might be preferable in these patients. Furthermore, the use of sex-specific thresholds (<40 ml/m2 for men and <32 ml/m2 for women) to define low-flow outperforms the guidelines' threshold of 35 ml/m2 in risk stratification after AVR.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Ecocardiografia Doppler em Cores , Implante de Prótese de Valva Cardíaca , Complicações Pós-Operatórias/mortalidade , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Canadá , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Cuidados Pré-Operatórios/métodos , Cuidados Pré-Operatórios/estatística & dados numéricos , Medição de Risco/métodos , Índice de Gravidade de Doença , Fatores Sexuais , Volume Sistólico
15.
J Ultrasound Med ; 27(9): 1313-9, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18716141

RESUMO

OBJECTIVE: The role of vascular risk factors in atherosclerosis development is well established, whereas risk factors involved in determining plaque vulnerability are still a matter of debate. We investigated the vascular risk factor distribution in patients with carotid plaques. METHODS: We consecutively assessed sonographic plaque morphologic characteristics, the degree of stenosis, and the common carotid artery intima-media thickness (IMT) in 1655 patients. Demographic data, a documented history of symptomatic cerebrovascular disease (CVD), and the presence of vascular risk factors were collected. According to literature, heterogeneous hypoechoic plaques with an irregular surface or ulcerations and those with a severe degree of stenosis (>or=70%) have been considered "complex" plaques at "major" risk of stroke; homogeneous hyperechoic plaques with smooth surface lesions have been considered "simple" plaques at minor risk. RESULTS: Univariate analysis showed that all vascular risk factors were associated with the presence of carotid atherosclerotic lesions. Multiple logistic regression showed an independent association of hypertension and diabetes with complex plaques, which also had a thicker IMT. A history of CVD was observed more frequently in complex plaques, which had a higher stenosis percentage even after patients with a severe degree of stenosis (>or=70%) and indications for carotid surgery were excluded. CONCLUSIONS: Hypertension and diabetes are related to a thicker IMT and more severe complex plaques, which may reflect the instability of atherosclerotic process. Because two-thirds of the patients with complex plaques were asymptomatic for CVD, this raises the importance of surveillance sonography to monitor plaque evolution for prevention of symptomatic CVD.


Assuntos
Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/epidemiologia , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/epidemiologia , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Medição de Risco/métodos , Idoso , Comorbidade , Estudos Transversais , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Feminino , Humanos , Hipertensão/diagnóstico , Hipertensão/epidemiologia , Incidência , Itália/epidemiologia , Masculino , Fatores de Risco
16.
Eur J Radiol ; 60(1): 120-4, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16730939

RESUMO

INTRODUCTION AND OBJECTIVES: Our experience concerning the use of color Doppler sonography (CDS) in the differential diagnosis of acute scrotum is reported. MATERIAL AND METHODS: From July 2000 to July 2005, 155 patients (median 17.2 years) were admitted with a diagnosis of acute scrotum (unilateral in 150 cases, bilateral in 5). Along with a careful anamnesis and the physical exam, all patients underwent a CDS study of the scrotal content using a sonograph GE Logiq 500 with a multifrequency (7.5-10 MHz) linear probe Small Part. The following CDS parameters were evaluated: intensity of the color-power signal on the testicular parenchyma and on the epididymis; systolic peak velocity (SPV) and telediastolic velocity (TDV) in correspondence of the gonadal hilum. Ultrasound and flowmetry parameters registered on the painful testis were compared with those registered on the healthy controlateral testis. The reduction/absence versus the increase of color-power signal in the parenchyma and the reduction/absence versus the increase of SPV and TDV in the centripetal intratesticular arteries were considered presumptive of testicular torsion versus orchiepididymitis. RESULTS: The results only refer to the 150 patients (300 testis) with acute monolateral scrotum. The clinical picture and the physical exam suggested a torsion of the spermatic cord in 40 cases, a spontaneous de-torsion in 5, an orchiepididymitis in 80, a blunt scrotal trauma in 15, a bulky epididymal cyst or a hydrocele in 4 and a testicular pain of unknown etiology in the remaining 6 cases. Standard US was pathological in 95 patients (63.3%); CDS was pathologic in 70 patients and in 42 of them suggested a testicular torsion. Fifty-three patients underwent surgical exploration: among 42 patients with a presumptive diagnosis of testicular torsion, the diagnosis was confirmed in 22 cases, no anomaly was found in 16 cases and in 4 patients a torsion of testicular appendix was found. The rupture of the tunica albuginea was present in six out of seven patients submitted to surgical exploration for previous blunt trauma and the sonographic diagnosis of hematocele was documented in all cases. The single false-negative diagnosis of testicular torsion in CDS occurred in an 18-month-old child. In presence of funicular torsion, the sensitivity and specificity of physical exam and CDS were 100% versus 95.7% and 86.5% versus 85.3%, respectively; sensitivity and specificity of SPV, TDV and color-Doppler signal on the testis were 100% and 94.8% versus 100% and 90.1% versus 95.7% and 90.8%. In the pre-operative assessment of scrotal trauma, the B-mode US showed a sensitivity and specificity of 100% and 90%, respectively; the color Doppler analysis has not supplied with additional elements for planning a surgical exploration. In presence of orchiepididymitis, the sensitivity and specificity of the physical exam in association to CDS was equal to 100%. In all patients with torsion of the testicular appendix, physical exam and CDS parameters were within normal limits. DISCUSSION AND CONCLUSIONS: In our experience CDS is an indispensable imaging modality for the clinical assessment of patients with acute scrotum; however, the informations it can afford are operator-dependent and have to be supported by the history and physical exam of the patient. CDS findings constitute probably an important medico-legal support when the necessity of surgical exploration is excluded; anyway, in presence of a clinical suspicion of testicular torsion, even with an apparently normal CDS, the surgical exploration is recommended.


Assuntos
Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Aumento da Imagem/métodos , Avaliação de Resultados em Cuidados de Saúde/métodos , Escroto/diagnóstico por imagem , Torção do Cordão Espermático/diagnóstico por imagem , Torção do Cordão Espermático/epidemiologia , Doença Aguda , Adolescente , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Int J Cardiol ; 221: 1107-15, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-27458659

RESUMO

BACKGROUND/OBJECTIVES: Paradoxical low-flow aortic stenosis (AS) with preserved left ventricular ejection fraction (LVEF) has only been described in severe AS. Controversy surrounds prognosis and management but no studies have reported this phenomenon in mild or moderate AS. We investigated the prevalence of flow and gradient patterns in this population, characterising their clinical and echocardiographic profile. METHODS: Consecutive subjects (n=1362) with isolated AS: mild (n=462, aortic valve area≥1.5cm(2), 2.5m/s

Assuntos
Estenose da Valva Aórtica , Valva Aórtica/fisiopatologia , Hemodinâmica/fisiologia , Volume Sistólico/fisiologia , Remodelação Ventricular/fisiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Feminino , Humanos , Masculino , Prevalência , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Singapura/epidemiologia
18.
J Am Coll Cardiol ; 32(1): 42-8, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9669247

RESUMO

OBJECTIVES: We tested the value of transesophageal Doppler echocardiography (TEDE) for quantitating proximal left coronary artery (LCA) stenosis by using the continuity equation. BACKGROUND: The continuity equation applied to a stenosis states that the ratio of the time-velocity integral (TVI) of prestenotic to stenotic flow velocities is equal to the ratio of stenotic to prestenotic cross-sectional areas. TEDE allows the measurement of coronary blood flow velocities within the proximal part of the LCA. METHODS; Forty-one patients with a stenosis of the proximal or mid left anterior descending coronary artery or with a nonostial stenosis of the left main coronary artery were studied. Coronary flow velocities were recorded by TEDE guided by color flow imaging. Prestenotic velocities were recorded by pulsed Doppler echocardiography and transstenotic velocities were recorded by pulsed or high pulse repetition frequency or continuous wave Doppler echocardiography. The prestenotic and transstenotic diastolic TVIs were calculated and the TEDE-derived percent area stenosis was calculated as (1 - TVI ratio) x 100. Quantitative angiography lesion analysis was performed using a computer-assisted automated edge-detection system. RESULTS: TEDE recordings were successful in 35 of the 41 patients. A good linear correlation was found between TEDE and quantitative angiographically derived percent area stenosis (r = 0.89, p = 0.0001, SEE 5.7). However, TEDE measurements underestimated the actual percent area stenosis (slope of regression 0.54). A better agreement (slope 1.08) was obtained after dividing prestenotic velocity by 2 in the continuity equation, based on the assumption of a parabolic cross-sectional velocity profile in the prestenotic segment. CONCLUSIONS: TEDE may be used for quantitating stenosis of the proximal part of the LCA with the use of a modified continuity equation that takes into account the parabolic velocity profile in the normal prestenotic segment.


Assuntos
Angiografia Coronária/estatística & dados numéricos , Doença das Coronárias/diagnóstico por imagem , Ecocardiografia Doppler de Pulso/estatística & dados numéricos , Ecocardiografia Transesofagiana/estatística & dados numéricos , Computação Matemática , Adulto , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Coronária/fisiologia , Doença das Coronárias/classificação , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
19.
J Am Coll Cardiol ; 25(1): 137-45, 1995 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-7798491

RESUMO

OBJECTIVES: The aim of this study was to provide a detailed description of echocardiographic and Doppler features of pseudoaneurysms involving the mitral-aortic intervalvular fibrosa and to compare echocardiographic and aortographic findings. BACKGROUND: Infection of the aortic valve may spread to the aortic annulus, resulting in ring abscesses or pseudoaneurysms, or both, of the intervalvular fibrosa, which can alter patient management and prognosis. METHODS: The echocardiographic and Doppler findings of 20 patients with pseudoaneurysms or ring abscesses, or both, were reviewed and compared with surgical and aortographic results. RESULTS: A total of 23 lesions were identified, of which 16 were intervalvular pseudoaneurysms, and 7 were ring abscesses. Transthoracic echocardiography detected 43% of the lesions, whereas transesophageal echocardiography identified 90% (p < 0.01). The most distinct feature of the pseudoaneurysms was marked pulsatility, with systolic expansion and diastolic collapse (mean systolic area [+/- SD] 4.1 +/- 3.4 cm2 vs. diastolic mean area 1.8 +/- 2.2 cm2, p < 0.05). Using color Doppler, two types were identified: unruptured pseudoaneurysms (n = 9), which communicated only with the left ventricular outflow tract and had a distinct flow pattern, and ruptured pseudoaneurysms (n = 7), which, in addition, communicated with the left atrium or aorta. Compared with pseudoaneurysms, ring abscesses were smaller and nonpulsatile and showed either no flow or continuous systolic and diastolic flow, the site of paravalvular aortic insufficiency. In 10 patients who underwent aortography, three lesions were identified, and findings were concordant with echocardiography. However, in seven patients aortographic findings were normal, whereas echocardiography identified intervalvular pseudoaneurysms, all of which were documented at operation. CONCLUSIONS: Intervalvular pseudoaneurysms are more frequently detected by transesophageal echocardiography than by aortography or transthoracic examination and exhibit distinct dynamic features and Doppler patterns that can further help characterize cavitary lesions in the aortic root and guide appropriate surgical intervention.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Análise de Variância , Falso Aneurisma/cirurgia , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Valva Aórtica/cirurgia , Aortografia , Cinerradiografia , Ecocardiografia Doppler em Cores/instrumentação , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Ecocardiografia Transesofagiana/instrumentação , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Transesofagiana/estatística & dados numéricos , Feminino , Ruptura Cardíaca/diagnóstico por imagem , Ruptura Cardíaca/cirurgia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Ruptura Espontânea
20.
Comput Math Methods Med ; 2015: 108274, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26078773

RESUMO

Vortex flow imaging is a relatively new medical imaging method for the dynamic visualization of intracardiac blood flow, a potentially useful index of cardiac dysfunction. A reconstruction method is proposed here to quantify the distribution of blood flow velocity fields inside the left ventricle from color flow images compiled from ultrasound measurements. In this paper, a 2D incompressible Navier-Stokes equation with a mass source term is proposed to utilize the measurable color flow ultrasound data in a plane along with the moving boundary condition. The proposed model reflects out-of-plane blood flows on the imaging plane through the mass source term. The boundary conditions to solve the system of equations are derived from the dimensions of the ventricle extracted from 2D echocardiography data. The performance of the proposed method is evaluated numerically using synthetic flow data acquired from simulating left ventricle flows. The numerical simulations show the feasibility and potential usefulness of the proposed method of reconstructing the intracardiac flow fields. Of particular note is the finding that the mass source term in the proposed model improves the reconstruction performance.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Ventrículos do Coração/diagnóstico por imagem , Biologia Computacional , Simulação por Computador , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Cardiovasculares , Modelos Estatísticos , Imagens de Fantasmas , Função Ventricular Esquerda/fisiologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa