Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.107
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 39(9): 2363-2367, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38604277

RESUMO

BACKGROUND: Arthrofibrosis is a debilitating postoperative complication and a major cause of patient dissatisfaction following total knee arthroplasty (TKA). There is no consensus regarding the optimal treatment for stiffness after TKA. For cases not amenable to manipulation under anesthesia (MUA), one component or full revision are both suitable options. In a value-based healthcare era, maximizing cost-effectiveness with optimized clinical outcomes for patients remains the ultimate goal. As such, we compared (1) Knee Injury and Osteoarthritis Outcome Scores for Joint Replacement (KOOS, JR), (2) range of motion (ROM), as well as (3) complication rates, including MUA and lysis of adhesions (LOA), between polyethylene exchange and full component revision for TKA arthrofibrosis. METHODS: Patients were queried from an institutional database who underwent revision TKA for arthrofibrosis between January 1, 2015, and April 31, 2021. There were 33 patients who underwent full revision and 16 patients who underwent polyethylene exchange. Demographics and baseline characteristics between the cohorts were analyzed. Postoperative outcomes included MUA, LOA, and re-revision rates as well as KOOS, JR, and extension and flexion ROM at a mean follow-up of 3.8 years. Baseline comorbidities, including age, body mass index, alcohol use, tobacco use, and diabetes, were comparable between the full revision and polyethylene exchange revision cohorts (P > .05). The one and full component revisions had similar preoperative KOOS, JR (43 versus 42, P = .85), and flexion (81 versus 82 degrees, P = .80) versus extension (11 versus 11 degrees, P = .87) ROM. RESULTS: The full component revision had higher KOOS, JR (65 versus 55, P = .04), and flexion (102 versus 92 degrees, P = .02), but similar extension (3 versus 3 degrees, P = .80) ROM at final follow-up compared to the polyethylene exchange revision, respectively. The MUA (18.2 versus 18.8%, P = .96) and LOA (2.0 versus 0.0%, P = .32) rates were similar between full component and polyethylene exchange revisions. There was one re-revision (3.0%) for the cohort of patients who initially underwent full revision. There were four full re-revisions (25.0%) and two polyethylene exchange re-revisions (12.5%) performed in the cohort of patients who initially underwent a polyethylene exchange revision. CONCLUSIONS: The full component revision for stiffness after TKA showed favorable KOOS, JR, ROM, and outcomes in comparison to the polyethylene exchange revision. While the optimal treatment for stiffness after TKA is without consensus, this study supports the use of the full component revision when applied to the institutional population at hand. It is imperative that homogeneity exists in preoperative definitions, preoperative baseline patient demographics, ROM and function levels, outcome measures, and preoperative indications, as well as the inclusion of clinical data that assesses complete exchange, single exchange, and tibial insert exchange.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Polietileno , Amplitude de Movimento Articular , Reoperação , Humanos , Artroplastia do Joelho/efeitos adversos , Feminino , Reoperação/estatística & dados numéricos , Masculino , Idoso , Pessoa de Meia-Idade , Prótese do Joelho/efeitos adversos , Articulação do Joelho/cirurgia , Fibrose , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Falha de Prótese/etiologia
2.
J Arthroplasty ; 39(6): 1545-1549, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38128624

RESUMO

BACKGROUND: The mode of femoral fixation for primary total hip arthroplasty (THA) is undetermined, with reported outcomes favoring different fixation methods. This study aimed to compare postoperative complications between cemented and cementless fixation at 90 days, 1 year, and 2 years in patients aged 65 years of age and older undergoing THA for osteoarthritis. METHODS: Using an all-payer, national database, patients 65 years and older undergoing primary THA, either with cementless (n = 56,701) or cemented (n = 6,283) femoral fixation for osteoarthritis were identified. A 1:1 propensity-matched analysis for age, sex, comorbidity index, alcohol abuse, tobacco use, obesity, and diabetes was performed, resulting in n = 6,283 patients in each cohort. Postoperative outcomes, including postoperative periprosthetic joint infection, aseptic revision, surgical site infection, pulmonary embolism, venous thromboembolism, wound complications, dislocation, periprosthetic fracture, and aseptic loosening were assessed. RESULTS: The cemented cohort had higher rates of infection (4.5 versus 0.8%, odds ratio [OR] 5.9, 95% confidence interval [CI] 4.33 to 7.93, P < .001), aseptic revision (2.9 versus 2.0%, OR 1.47, 95% CI 1.17 to 1.85, P = .001), venous thromboembolism (1.8 versus 1.3%, OR 1.40, 95% CI 1.05 to 1.87, P < .001), and aseptic loosening (1.5 versus 0.7%, OR 2.31, 95% CI 1.60 to 3.32, P < .001) at 90-days. At 1 and 2 years, the cemented cohort had higher rates of infection, aseptic revision, and aseptic loosening (all P < .001). Rates of periprosthetic fracture were similar at all time points (all P < .001). CONCLUSIONS: Cemented fixation had higher rates of infection, aseptic loosening, and aseptic revision. This finding supports the current use of cementless fixation, but the ultimate decision regarding fixation type should be based on the proper optimization of the patient's comorbidities and bone quality.


Assuntos
Artroplastia de Quadril , Cimentos Ósseos , Osteoartrite do Quadril , Complicações Pós-Operatórias , Reoperação , Humanos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Artroplastia de Quadril/efeitos adversos , Feminino , Masculino , Idoso , Osteoartrite do Quadril/cirurgia , Reoperação/estatística & dados numéricos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Idoso de 80 Anos ou mais , Prótese de Quadril/efeitos adversos , Falha de Prótese/etiologia , Infecções Relacionadas à Prótese/etiologia , Fêmur/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
3.
Eur J Orthop Surg Traumatol ; 34(4): 1825-1830, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38429555

RESUMO

INTRODUCTION: There is continued debate regarding the survivorship and revision rate of cementless versus cemented total knee arthroplasty (TKA) prostheses. This includes the assessment of early revision surgery due to aseptic loosenings and periprosthetic joint infections (PJIs). Studies have not always taken into account the impact of comorbidities, such as diabetes, obesity, and tobacco. Therefore, we compared revisions in a large population of patients undergoing cemented or cementless TKAs at 90 days, 1 year, and 2 years. METHODS: A review of an administrative claims database was used to identify patients undergoing primary TKA, either cementless (n = 8,890) or cemented (n = 215,460), from October 1, 2015 to October 31, 2020. Revision surgery for PJI and aseptic loosening were identified with diagnosis and associated procedural codes at 90 days, 1 year, and 2 years and then compared between groups. A propensity matched-analysis was performed for age, sex, Charles Comorbidity Index (CCI) > 3, alcohol abuse, tobacco use, obesity, and diabetes. Chi square tests assessed statistical significance of differences in the matched cohorts using odds ratios (ORs) with 95% confidence intervals (CIs). A P < 0.05 was defined as statistically significant. RESULTS: Cementless TKA was associated with similar revisions rates due to PJIs at 90 days (OR, 1.04, 95% CI 0.79-1.38, p = 0.83), 1 year (OR, 0.93, 95% CI 0.75-1.14, p = 0.53, and 2 years (OR, 0.87, 95% CI 0.73-1.05, p = 0.17) in comparison to the cemented TKA cohort. The odds ratio of revision due to aseptic loosening was similar as well at 90 days (OR, 0.67, 95% CI 0.34-1.31, 0.31), 1 year (OR, 1.09, 95% CI 0.73-1.61, p = 0.76), and 2 years (OR, 1.00, 95% CI 0.73-1.61, p = 0.99). CONCLUSIONS: This study found a comparable risk of PJI and aseptic loosening in cementless and cemented TKA when controlling for several comorbidities, such as tobacco, diabetes, and alcohol. Therefore, with proper patient selection, cementless TKAs can be performed with expectation of low risks of infections and aseptic loosenings.


Assuntos
Artroplastia do Joelho , Cimentos Ósseos , Pontuação de Propensão , Falha de Prótese , Infecções Relacionadas à Prótese , Reoperação , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/instrumentação , Feminino , Masculino , Reoperação/estatística & dados numéricos , Idoso , Falha de Prótese/etiologia , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/etiologia , Prótese do Joelho/efeitos adversos , Estudos Retrospectivos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Comorbidade , Cimentação
4.
Circ Res ; 128(9): 1398-1417, 2021 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-33914604

RESUMO

Aortic stenosis is the most common valvular disease requiring valve replacement. Valve replacement therapies have undergone progressive evolution since the 1960s. Over the last 20 years, transcatheter aortic valve replacement has radically transformed the care of aortic stenosis, such that it is now the treatment of choice for many, particularly elderly, patients. This review provides an overview of the pathophysiology, presentation, diagnosis, indications for intervention, and current therapeutic options for aortic stenosis.


Assuntos
Estenose da Valva Aórtica/terapia , Idoso , Idoso de 80 Anos ou mais , Aloenxertos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Bioprótese , Tomada de Decisão Clínica , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese/etiologia , Valva Pulmonar/transplante , Avaliação de Sintomas , Substituição da Valva Aórtica Transcateter
5.
World J Urol ; 39(2): 579-588, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32307555

RESUMO

OBJECTIVE: To preliminarily study the characteristics of bacterial flora distribution in the urine of ureteral stent encrustation patients as well as the relation between Bacteroides and stent encrustation. METHODS: Patients undergoing ureteral stenting were included in the study and divided into encrustation group and non-encrustation group based on the condition of stent encrustation. The urine of patients was collected to undergo 16s DNA test to compare the bacterial flora distribution characteristics of the two groups. The bacterial genus with highest abundance in the urine of encrustation group was used for animal experiment. A rat model with a foreign body in the bladder was created, in which the rats were injected with the aforesaid bacterial genus. A control group injected with normal saline was also formed. The incidence of foreign body tube encrustation between the two groups was compared. RESULTS: The urine collected from the patients in encrustation group contained a variety of bacteria, while dominant bacteria genera included g_Lactobacillus (23.1%), g_Bacteroides (18.8%) and g_norank_Bacteroides (17.1%). While the urine from the non-encrustation group was less diverse in bacteria flora, as the major bacteria genera were g_Escherichia-Shigella (32.2%), g_Enterococcus (24.9%) and g_Pseudomonas (18.2%). Bacteroidetes in the encrustation group were significantly higher, therefore Bacteroides fragilis in this genus was adopted for animal experiment, resulting in a higher incidence of foreign body tube encrustation in the bladder among rats. CONCLUSION: The present study enriches our knowledge about ureteral stent encrustation and reveals that the target regulation of urine bacteria is worth further research and clinical application.


Assuntos
Infecções por Bacteroides/complicações , Bacteroides fragilis , Complicações Pós-Operatórias/microbiologia , Falha de Prótese/etiologia , Stents , Ureter/cirurgia , Adulto , Animais , Modelos Animais de Doenças , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ratos
6.
Med Sci Monit ; 27: e930760, 2021 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-33712550

RESUMO

BACKGROUND Patients with hip joint infections in childhood often have many aftereffects of different degrees, regardless of the kind of treatment or natural course. Total hip arthroplasty is currently the most effective treatment for sequelae of childhood hip septic or tuberculous infection. This is a mid-term follow-up study of treatment results of patients who had undergone total hip arthroplasty (THA) with cementless prostheses. MATERIAL AND METHODS We retrospectively analyzed and followed 45 patients (45 hips) who underwent THA with cementless prostheses between 2010 and 2017. There were 45 patients, including 17 men and 28 women. The average age of the patients was 46 years (range, 18-67 years). All hip infections occurred in early childhood or adolescence, and the mean interval between initial infection and THA was 38.2 years (range, 15-60 years). The mean follow-up was 6.1 years (range, 2.7-9.5 years). RESULTS Two patients underwent revision surgery because of loosening of the prosthesis, and 1 patient underwent revision surgery because of a new infection with no relationship with childhood infection during the follow-up. The average Harris hip scores significantly increased from 43.1 to 86.4 (P<0.01), and the average visual analog scale significantly increased from 4.6 to 1.7 (P<0.01). The hip dysfunction and osteoarthritis outcome scores were also significantly changed (P<0.01) at the final follow-up. There were 2 cases of transient sciatic nerve palsy and intraoperative periprosthetic fractures in 3 cases. During follow-up, single revision was performed after 6 years of primary arthroplasty because of aseptic loosening in 2 cases and prosthesis infection in 1 case, which was not related to childhood pathogens. CONCLUSIONS THA for patients with sequelae of hip joint infection has a satisfactory effect that can effectively relieve joint pain and improve hip function. The recurrence rate of infection after either pyogenic infection or tuberculous is very low. The mid-term outcomes of THA in this setting were satisfactory, with high prosthesis survivorship and hip function scores.


Assuntos
Artroplastia de Quadril/métodos , Articulação do Quadril/cirurgia , Adulto , Experiências Adversas da Infância , Idoso , China , Feminino , Seguimentos , Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Infecções/fisiopatologia , Masculino , Pessoa de Meia-Idade , Falha de Prótese/etiologia , Reoperação/tendências , Estudos Retrospectivos , Resultado do Tratamento
7.
J Artif Organs ; 24(2): 234-242, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33449228

RESUMO

We evaluated the clinical and radiographic outcomes of femoral head penetration and total hip arthroplasties with untreated and poly (2-methacryloyloxyethyl phosphorylcholine) (PMPC)-grafted highly cross-linked polyethylene (HXLPE) acetabular liners against 26-, 28-, and 32-mm cobalt-chromium alloy femoral heads 3 years after the index surgery. Three combinations of the articulating surfaces were evaluated in the present study: untreated or PMPC-grafted HXLPE liner against 26- or 28-mm femoral heads (n = 16, 24) [control (26 or 28 mm) and PMPC (26 or 28 mm)] and PMPC-grafted HXLPE liner against 32-mm femoral heads (n = 64) [PMPC (32 mm)]. The clinical outcomes improved at 3 years postoperatively for the groups. No periprosthetic osteolysis or acetabular component migration was detected, and no revision surgery was performed among the groups. The steady-state wear rate of the PMPC (26 or 28 mm) group (0.021 mm/year) was lower than that of the control (26 or 28 mm) group (- 0.015 mm/year); the steady-state wear was under the clinical threshold. In contrast, the steady-state wear rate of the PMPC (32 mm) group (-0.006 mm/year) showed no significant difference when compared to that of the PMPC (26 or 28 mm) group (p < 0.01). The results obtained in the present study clearly demonstrate that PMPC-grafting onto an HXLPE surface improved the wear resistance of acetabular liners, even when coupled with larger femoral heads. Although further follow-up evaluations are required, PMPC-grafted HXLPE acetabular liners may be a promising approach to extend the longevity of artificial joints.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fosforilcolina/análogos & derivados , Polietileno/química , Ácidos Polimetacrílicos/química , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Artroplastia de Quadril/estatística & dados numéricos , Análise de Falha de Equipamento , Feminino , Cabeça do Fêmur/química , Cabeça do Fêmur/cirurgia , Seguimentos , Prótese de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Fosforilcolina/química , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Falha de Prótese/etiologia , Reoperação/estatística & dados numéricos , Resultado do Tratamento
8.
J Pediatr Orthop ; 41(4): e347-e352, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33560710

RESUMO

BACKGROUND: Although Fassier-Duval (FD) rods have been used for almost 2 decades, knowledge of factors predisposing to their failure is limited. Thus, the purpose of this study was to: (1) present the most common complications of FD rodding, (2) present tips on how to avoid or overcome them, and (3) identify factors predisposing to treatment failure. METHODS: Fifty-eight rod segments in 19 patients with osteogenesis imperfecta (mainly type III) underwent analysis with a median follow-up (FU) time of 4.4 years. We assessed the total number of complications clinically and radiographically. Next, the possible predisposing factors leading to failure were assessed using the Mann-Whitney U test. In addition, we evaluated the cutoff age for the increased rate of complications using the Youden index. A P<0.05 was considered significant. RESULTS: The total number of complications reached 44.8%. The most common complications included: migration of the male or female implant (45.7% and 25.7% out of the total number of complications, respectively), bone fracture with bending of the rod (8.6%), and rotational deformities (8.6%). Significant differences in patients' ages at the time of surgery were found between the group with and without complications (P=0.04), while sex, segment treated, preceding surgeries, length of FU, FD rod diameter, and length of bisphosphonate treatment were not significant. The Youden index showed that the risk of complications rose significantly in patients treated when younger than 5.5 years of age (P<0.05). CONCLUSIONS: This series displays the effectiveness and utility of FD rods at a median FU of over 4 years. Complication rates were comparable with the existing literature, with a notable increase in the number of side effects observed in younger patients (below the age of 5). LEVEL OF EVIDENCE: Level IV-therapeutic study.


Assuntos
Fraturas Ósseas/etiologia , Fixadores Internos/efeitos adversos , Osteogênese Imperfeita/cirurgia , Próteses e Implantes/efeitos adversos , Falha de Prótese/etiologia , Adolescente , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Masculino , Osteogênese Imperfeita/complicações , Osteogênese Imperfeita/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Falha de Tratamento
9.
Int J Mol Sci ; 22(5)2021 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-33670995

RESUMO

Nickel (Ni2+) is one of the most common allergens, affecting around 10-15% of the general population. As the demand for orthopedic implant surgery rises, the number of surgical revisions due to joint implant failure also increases. There is evidence that some patients develop joint failure due to an immune response to a component of the implant, and we have found that Ni2+ is an especially important cause. Hence, understanding the mechanisms by which Ni2+ allergy induces joint implant failure becomes a critical research question. The structural basis of Ni2+ activation of pathogenic T cells is still not clear. The purpose of this study was to characterize Ni2+-reactive T cell repertoires derived from the peripheral blood of joint failure patients due to Ni2+ sensitization using single-cell sequencing techniques. We stimulated the proliferation of Ni2+ -reactive T cells from two implant failure patients in vitro, and sorted them for single-cell VDJ sequencing (10× genomics). We identified 2650 productive V-J spanning pairs. Both TCR α chains and ß chains were enriched. TRBV18 usage is the highest in the P7 CD4+ population (18.1%), and TRBV5-1 usage is the highest in the P7 CD8+ population (12.1%). TRBV19 and TRBV20-1 segments are present in a high percentage of both P7 and P9 sequenced T cells. Remarkably, the alpha and beta chain combination of TRAV41-TRBV18 accounts for 13.5% of the CD4+ population of P7 patient. Compared to current Ni specific T cell repertoire studies of contact dermatitis, the Vα and Vß usages of these joint implant failure patients were different. This could be due to the different availability of self-peptides in these two different tissues. However, TRBV19 (Vß17) was among frequently used TCR ß chains, which are common in previous reports. This implies that some pathogenic T cells could be similar in Ni2+ hypersensitivities in skin and joints. The alignment of the TCR CDR3ß sequences showed a conserved glutamic acid (Glu) that could potentially interact with Ni2+. The study of these Ni2+ specific TCRs may shed light on the molecular mechanism of T cell activation by low molecular weight chemical haptens.


Assuntos
Haptenos , Hipersensibilidade/metabolismo , Prótese Articular , Níquel/imunologia , Falha de Prótese/etiologia , Receptores de Antígenos de Linfócitos T/genética , Linfócitos T/imunologia , Feminino , Humanos , Hipersensibilidade/complicações , Hipersensibilidade/genética , Hipersensibilidade/imunologia , Análise de Sequência de DNA , Análise de Célula Única , Linfócitos T/metabolismo , Éxons VDJ/genética
10.
Acta Orthop ; 92(1): 91-96, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33143501

RESUMO

Background and purpose - The population of the Nordic countries is aging and the number of elderly patients undergoing total knee arthroplasty (TKA) is also expected to increase. Reliable fixation methods are essential to avoid revisions. We compared the survival of different TKA fixation concepts with cemented fixation as the gold standard.Patients and methods - We used data from the Nordic Arthroplasty Register Association (NARA) database of 265,877 unconstrained TKAs performed for patients aged ≥ 65 years with primary knee osteoarthritis between 2000 and 2016. Kaplan-Meier (KM) survival analysis with 95% confidence intervals (CI) and the Cox multiple-regression model were used to compare the revision risk of the fixation methods.Results - Cemented fixation was used in 243,166 cases, uncemented in 8,000, hybrid (uncemented femur with cemented tibia) in 14,248, and inverse hybrid (cemented femur with uncemented tibia) fixation in 463 cases. The 10-year KM survivorship (95% CI) of cemented TKAs was 96% (96 - 97), uncemented 94% (94 - 95), hybrid 96% (96 - 96), and inverse hybrid 96% (94 - 99), respectively. Uncemented TKA was associated with increased risk of revision compared with the cemented TKA; the adjusted hazard ratio was 1.3 (95% CI 1.1 - 1.4).Interpretation - Cemented, hybrid, and inverse hybrid TKAs showed 10-year survival rates exceeding 95%. Uncemented fixation was associated with an increased risk of revision in comparison with cemented fixation. As both hybrid and inverse hybrid fixation were used in only a limited number of TKAs, indicating possibility of selection bias in their favor, cemented TKA still remains the gold standard, as it works reliably in the hands of many.


Assuntos
Artroplastia do Joelho/métodos , Cimentação , Prótese do Joelho , Desenho de Prótese , Falha de Prótese/etiologia , Reoperação/estatística & dados numéricos , Idoso , Artroplastia do Joelho/instrumentação , Estudos de Coortes , Feminino , Humanos , Masculino , Sistema de Registros , Países Escandinavos e Nórdicos
11.
Acta Orthop ; 92(1): 97-101, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33143505

RESUMO

Background and purpose - Obesity is a considerable medical challenge in society. We investigated the risk of revision for any reasons and for infection in patients having total knee arthroplasty (TKA) for osteoarthritis (OA) within 2 years after bariatric surgery (BS) and compared them with TKAs without BS.Patients and methods - We used the Scandinavian Obesity Surgery Registry (SOReg) and the Swedish Knee Arthroplasty Register (SKAR) to identify patients operated on in 2009-2019 with BS who had had primary TKA for OA within 2 years after the BS (BS group) and compared them with TKAs without prior BS (noBS group). We determined adjusted hazard ratio (HR) for the BS group and noBS group using Cox proportional hazard regression for revision due to any reasons and for infection. Adjustments were made for sex, age groups, and BMI categories preoperatively.Results - 441 patients were included in the BS group. The risk of revision for infection was higher for the BS group with HR 2.2 (95% CI 1.1-4.7) adjusting for BMI before the TKA, while the risk of revision for any reasons was not statistically significant different for the BS group with HR 1.3 (CI 0.9-2.1). Corresponding figures when adjusting for BMI before the BS were HR 0.9 (CI 0.4-2) and HR 1.2 (CI 0.7-2).Interpretation - Our findings did not indicate that BS prior to TKA was associated with lower risk of revision.


Assuntos
Artroplastia do Joelho , Cirurgia Bariátrica , Falha de Prótese/etiologia , Infecções Relacionadas à Prótese/etiologia , Reoperação/estatística & dados numéricos , Adulto , Idoso , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Sistema de Registros , Suécia
12.
Acta Orthop ; 92(4): 413-418, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33821752

RESUMO

Background and purpose - Reported revision rates due to dislocation after hemiarthroplasty span a wide range. Dislocations treated with closed reduction are rarely reported despite the fact that they can be expected to constitute most of the dislocations that occur. We aimed to describe the total dislocation rate on the national level, and to identify risk factors for dislocation.Patients and methods - We co-processed a national cohort of 25,678 patients in the Swedish Hip Arthroplasty Register, with the National Patient Register (NPR) and Statistics Sweden. Dislocation was defined as the occurrence of any ICD-10 or procedural code related to hip dislocation recorded in the NPR, with a minimum of 1-year-follow-up. In theory, all early dislocations should thereby be traced, including those treated with closed reduction only.Results - 366/13,769 (2.7%) patients operated on with direct lateral approach dislocated, compared with 850/11,834 (7.2%) of those with posterior approach. Posterior approach was the strongest risk factor for dislocation (OR = 2.7; 95% CI 2.3-3.1), followed by dementia (OR = 1.3; CI 1.1-1.5). The older the patients, the lower the risk of dislocation (OR = 0.98 per year of age; CI 0.98-1.0). Neither bipolar design nor cementless stems influenced the risk.Interpretation - The choice of posterior approach and dementia was associated with an increased dislocation risk. When hips treated with closed reduction were identified, the frequency of dislocation with use of direct lateral and posterior approach more than doubled and tripled, respectively, compared with when only revisions due to dislocation are measured.


Assuntos
Fraturas do Colo Femoral/cirurgia , Hemiartroplastia/métodos , Luxação do Quadril/etiologia , Complicações Pós-Operatórias/etiologia , Falha de Prótese/etiologia , Reoperação/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Luxação do Quadril/cirurgia , Humanos , Masculino , Complicações Pós-Operatórias/cirurgia , Fatores de Risco , Suécia
13.
Acta Orthop ; 92(2): 137-142, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33438503

RESUMO

Background and purpose - Dislocation of total hip arthroplasties (THA) is often treated with closed reduction and traditionally not registered in orthopedic registers. This study aimed to create an algorithm designed to identify cases of dislocations of THAs with high sensitivity, specificity, and positive predictive value (PPV) based on codes from the Danish National Patient Register (DNPR).Patients and methods - All patients (n = 31,762) with primary osteoarthritis undergoing THA from January 1, 2010 to December 31, 2014 were included from the Danish Hip Arthroplasty Register (DHR). We extracted available data for every hospital contact in the DNPR during a 2-year follow-up period, then conducted a comprehensive nationwide review of 5,096 patient files to register all dislocations and applied codes.Results - We identified 1,890 hip dislocations among 1,094 of the included 31,762 THAs. More than 70 different diagnoses and 55 procedural codes were coupled to the hospital contacts with dislocation. A combination of the correct codes produced a sensitivity of 63% and a PPV of 98%. Adding alternative and often applied codes increased the sensitivity to 91%, while the PPV was maintained at 93%. Additional steps increased sensitivity to 95% but at the expense of an unacceptable decrease in the PPV to 82%. Specificity was, in all steps, greater than 99%.Interpretation - The developed algorithm achieved high and acceptable values for sensitivity, specificity, and predictive values. We found that surgeons in most cases coded correctly. However, the codes were not always transferred to the discharge summary. In perspective, this kind of algorithm may be used in Danish quality registers.


Assuntos
Algoritmos , Artroplastia de Quadril , Luxação do Quadril/diagnóstico , Luxação do Quadril/epidemiologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese/etiologia , Estudos de Coortes , Dinamarca/epidemiologia , Humanos , Classificação Internacional de Doenças , Valor Preditivo dos Testes , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco
14.
Foot Ankle Surg ; 27(4): 381-388, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32505511

RESUMO

BACKGROUND: The prevalence of osteoarthritis of the hallux metatarsophalangeal joint (MTPJ) is 1 in 40 people over the age of 50. Surgical treatment options for MTPJ arthritis include joint preservation, joint resurfacing, and arthrodesis. Hallux MTPJ implants have evolved over the past several decades, but are associated with various complications. The aim of this study was to examine the MAUDE database to determine reported adverse events for hallux MTPJ implants. MATERIALS AND METHODS: The US Food and Drug Administration's (FDA) Manufacturer and User Facility Device Experience (MAUDE) database was reviewed from 2010 to 2018 to review voluntary reported adverse event reports for approved implants within the United States. We recorded the type of adverse event and excluded duplicate reports and those extracted from already published literature. RESULTS: Among 64 reported hallux MTPJ implant adverse events, the most common modes of adverse events were component loosening (34%), infection (14.1%), component fracture (9.4%), inflammation (9.4%), and allergic reaction (7.8%). Regarding implant type, Cartiva SCI had the highest percentage of adverse events (23.4%), followed by Arthrosurface ToeMotion (20.3%), Ascension MGT (12.5%), Arthrosurface HemiCAP® (10.9%), Futura primus (9.4%), and Osteomed Reflexion (6.3%). There was an increase in reported adverse events after 2016. The MAUDE database does not report the total incidence of implant insertion. CONCLUSION: Our study of the MAUDE database demonstrated that component loosening and infection are the most common modes of adverse events for hallux MTPJ implants. Cartiva accounted for one-fourth of the implant-related adverse events during our study period, followed by ToeMotion, and Ascension MGT implants. Continued reporting of adverse events will improve our understanding on short and long-term complications of various hallux MTPJ implants. LEVEL OF EVIDENCE: Level IV; Case Series from Large Database Analysis; Treatment Study.


Assuntos
Artrodese/instrumentação , Artroplastia de Substituição/instrumentação , Bases de Dados Factuais , Hallux Rigidus/cirurgia , Hallux/cirurgia , Prótese Articular/efeitos adversos , Articulação Metatarsofalângica/cirurgia , Osteoartrite/cirurgia , United States Food and Drug Administration , Adulto , Idoso , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Osteoartrite/epidemiologia , Falha de Prótese/etiologia , Infecções Relacionadas à Prótese/etiologia , Resultado do Tratamento , Estados Unidos/epidemiologia
15.
Int J Colorectal Dis ; 35(6): 1163-1166, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32144532

RESUMO

AIM: Lead migration is a common cause of loss of efficacy in sacral nerve modulation. Our aim was to systematically study the migration pattern of tined leads in sacral nerve modulation. Our hypothesis was that tined leads may promote forward migration because of their configuration. METHOD: Consecutive patients treated with sacral nerve modulation with a tined lead electrode, who had experienced loss of efficacy and had radiographs both at baseline and after loss of efficacy between 2005 and 2016 were eligible for inclusion. RESULTS: Twenty-five patients out of 70 with loss of efficacy were studied. Lead migration was measured as percent electrode movement in relation to sacral cortex at lateral projection. All had some degree of lead migration, ranging from 35% backward to 74% forward migration. Sixteen (64%) had forward migration while nine (36%) had backward migration. In seven patients (28%), loss of efficacy was associated with an episode of perceived mechanical strain on the electrode. Fifty percent (4/8) who associated their loss of efficacy with an adverse event had forward migration of the electrode. CONCLUSIONS: Forward lead migration with concomitant loss of efficacy seems to be a common event in patients with tined leads, hence supporting our hypothesis. The retrospective design and that some of the patients with loss of efficacy could not be included because of incomplete data, which is a limitation to the study. Further studies are needed to confirm to what extent the direction and magnitude of the migration relate to loss of efficacy.


Assuntos
Terapia por Estimulação Elétrica , Eletrodos Implantados/efeitos adversos , Incontinência Fecal/terapia , Falha de Prótese , Constipação Intestinal/terapia , Humanos , Plexo Lombossacral , Desenho de Prótese , Falha de Prótese/etiologia , Radiografia , Estudos Retrospectivos
16.
Eur Spine J ; 29(7): 1544-1552, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32447531

RESUMO

PURPOSE: As yet, there are no studies describing a relationship between radiographic subsidence after lumbar total disc replacement (TDR) and patient symptoms. To investigate if subsidence, in terms of penetrated bone volume or angular rotation over time (ΔPBV and ΔAR), is related to clinical outcome. To assess if subsidence can be predicted by position implant asymmetry (IA) or relative size of the TDR, areal undersizing index (AUI) on direct post-operative radiographs. METHODS: Retrospective cohort study consists of 209 consecutive patients with lumbar TDR for degenerative disc disease. A three-dimensional graphical representation of the implant in relation to the bony endplates was created on conventional radiographs. Consequently, the PBV, AR, IA and AUI were calculated, direct post-operative (DPO) and at last follow-up (LFU). For clinical evaluation, patients with substantial pain (VAS ≥ 50) and malfunction (ODI ≥ 40) were considered failures. RESULTS: At a mean follow-up of 16.7 years, 152 patients (73%) were available for analysis. In 32 patients, revision by spinal fusion had been performed. Both ΔAR (4.33° vs. 1.83°, p = 0.019) and ΔPBV (1448.4 mm3 vs. 747.3 mm3, p = 0.003) were significantly higher in the failure-compared to the success-group. Using ROC curves, thresholds for symptomatic subsidence were defined as ΔPBV ≥ 829 mm3 or PBV-LFU ≥ 1223 mm3 [area under the curve (AUC) 0.723, p = 0.003 and 0.724, p = 0.005, respectively]. Associations between symptomatic subsidence and AUI-DPO ≥ 0.50 (AUC 0.750, p = 0.002) and AR-DPO ≥ 3.95° (AUC 0.690, p = 0.022) were found. CONCLUSION: Subsidence of a TDR is associated with a worse clinical outcome. The occurrence of subsidence is higher in case of incorrect placement or shape mismatch.


Assuntos
Degeneração do Disco Intervertebral , Disco Intervertebral , Prótese Articular , Vértebras Lombares , Fusão Vertebral , Substituição Total de Disco , Adulto , Feminino , Humanos , Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/cirurgia , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/cirurgia , Prótese Articular/efeitos adversos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Falha de Prótese/efeitos adversos , Falha de Prótese/etiologia , Estudos Retrospectivos , Substituição Total de Disco/efeitos adversos , Resultado do Tratamento
17.
BMC Musculoskelet Disord ; 21(1): 230, 2020 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-32284062

RESUMO

BACKGROUND: Femoral neck fractures are one of the problems in clinical treatment. The prognosis is uncertain. Currently, No internal fixation method is superior to other internal fixation methods in the treatment of femoral neck fractures. Therefore, the internal fixation system needs to be further explored. The aim of this study was to compare clinical outcomes of femoral neck dynamic compression locking system (DCLS) and multiple cannulated compression screws(MCCS) in the treatment of femoral neck fractures. METHODS: A prospective analysis of 54 cases of femoral neck fractures treated with either a DCLS (n = 28) or MCCS (n = 26) was conducted between December 2015 and November 2017 in authors' hospitals. The perioperative and postoperative parameters of the two groups were recorded and evaluated. RESULTS: Fifty-four patients were followed up for 24-47 months. The etiology was caused by a fall. There was no significant difference in follow-up time, operation time, incision length, surgical blood loss, the incidence of perioperative and postoperative healing complications, and mobility in the two groups (all P > 0.05). The Harris score, fracture healing time, femoral neck shortening, partial weight-bearing time and complete weight-bearing time were significantly better in the DCLS group than in the MCCS group (all P < 0.05). The fracture healing rate in the DCLS group was higher than that in the MCCS group. CONCLUSIONS: The DCLS and MCCS might be equally effective in terms of operation time, incision length, surgical blood loss, the incidence of perioperative and postoperative healing complications, and mobility in the treatment of femoral neck fractures. However, the DCLS is superior to the MCCS in Harris score, fracture healing time, femoral neck shortening, weight-bearing time and fracture healing rate. So, DCLS deserves further study.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral/cirurgia , Colo do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Idoso , Perda Sanguínea Cirúrgica/prevenção & controle , Feminino , Colo do Fêmur/diagnóstico por imagem , Consolidação da Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias , Pressão , Estudos Prospectivos , Falha de Prótese/etiologia , Radiografia , Resultado do Tratamento
18.
BMC Musculoskelet Disord ; 21(1): 411, 2020 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-32600293

RESUMO

BACKGROUND: Both cylindrical and tapered stems are commonly used in revision total hip arthroplasty. However, whether the geometry of prosthesis stem has an effect on patient prognosis is unclear. We assume that the tapered stem results in better clinical outcome than the cylindrical stem. METHODS: A multicenter review of 120 femoral revisions with Paprosky I, II, and III defects using cobalt chrome cylindrical stem (54 hips) or titanium tapered stem (66 hips) was performed with an average follow-up of 6 years. Demographic data were comparable between groups. RESULTS: No significant group differences were found in surgery time, bleeding volume, postoperative Harris Hip Score, level of overall satisfaction, and 8-year cumulative survival. However, intraoperative fractures occurred significantly less in the tapered group (4.5%) than in the cylindrical group (14.8%), and stem subsidence was significantly less in the tapered group (2.17 mm) than in the cylindrical group (4.17 mm). A higher ratio of bone repair and lower bone loss were observed in the tapered group compared with the cylindrical group. The postoperative thigh pain rate was higher in the cylindrical group (12.9%) than in the tapered group (4.5%). CONCLUSION: Both cylindrical stem and tapered stem can achieve satisfactory mid-term clinical results in revision total hip arthroplasty. The tapered stem has better bone restoration of proximal femur, lower incidence of intraoperative fractures, and lower postoperative thigh pain rate compared with the cylindrical stem.


Assuntos
Artroplastia de Quadril/instrumentação , Colo do Fêmur , Prótese de Quadril/classificação , Osseointegração/fisiologia , Desenho de Prótese , Idoso , Idoso de 80 Anos ou mais , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiologia , Articulação do Quadril/cirurgia , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Falha de Prótese/etiologia , Radiografia , Reoperação/instrumentação , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
19.
BMC Musculoskelet Disord ; 21(1): 69, 2020 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-32013950

RESUMO

BACKGROUND: En bloc excision has been increasingly used for the management of giant cell tumors (GCTs) in the distal radius. An osteoarticular allograft has been used extensively for decades, and custom-made prosthesis reconstruction has been more recently applied. We aimed to compare the clinical outcomes of the two procedures. METHODS: We retrospectively analyzed 30 patients with Campanacci III or recurrent GCTs of the distal radius for follow-up at a mean of 33.2 months. In total, 15 underwent osteoarticular allograft reconstruction (allograft group) and 15 received cementless three-dimensional (3D)-printed prosthesis reconstruction (prosthesis group) between March 18, 2013, and May 20, 2018. All patients underwent by clinical and radiological examinations, including pre- and postoperative active range of motion (ROM) of the wrist, VAS score, grip strength, degenerative change of wrist, Mayo wrist score and Musculoskeletal Tumor Society (MSTS) score. Complications were evaluated using the Henderson classification. RESULTS: Both groups showed significantly increased ROM, grip strength, Mayo score and MSTS score postoperatively. Furthermore, the extension, flexion, MSTS, and Mayo score were significantly higher in the prosthesis group. There was no significant difference in grip strength and VAS between the groups. In allograft group, one patient had a late infection one had resorption of allograft without allograft bone fracture. and four had wrist subluxation. All patients had degenerative changes (mean 9 months). In the prosthesis group, three patients developed wrist subluxation, three had separation of the distal radioulnar joint, and none of the patients developed wrist degeneration. CONCLUSIONS: Our study compared the objective functional outcomes and complications of two reconstructive methods for Campanacci III or recurrent GCT in the distal radius. 3D-printed prosthesis replacement can partially preserve wrist function better than allograft reconstruction in the short-term. During the design of 3D-printed prosthesis, preoperative morphological assessment of the affected proximal row carpal is helpful to control postoperative dislocation. After allograft reconstruction, wrist degeneration, which has been demonstrated in all patients, severely influence their wrist function. Therefore, compared to allograft reconstruction, 3D-printed prosthesis reconstruction has irreplaceable advantages at early-stage application, especially in wrist function, however, further studied with a larger number of cases and longer follow-up.


Assuntos
Membros Artificiais/efeitos adversos , Neoplasias Ósseas/cirurgia , Transplante Ósseo/métodos , Tumor de Células Gigantes do Osso/cirurgia , Recidiva Local de Neoplasia/cirurgia , Implantação de Prótese/métodos , Rádio (Anatomia)/patologia , Adulto , Aloenxertos/transplante , Biópsia , Neoplasias Ósseas/patologia , Neoplasias Ósseas/fisiopatologia , Transplante Ósseo/efeitos adversos , Feminino , Seguimentos , Tumor de Células Gigantes do Osso/patologia , Tumor de Células Gigantes do Osso/fisiopatologia , Humanos , Imageamento Tridimensional , Luxações Articulares/epidemiologia , Luxações Articulares/etiologia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/fisiopatologia , Impressão Tridimensional , Falha de Prótese/etiologia , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Transplante Homólogo/efeitos adversos , Transplante Homólogo/métodos , Resultado do Tratamento , Articulação do Punho/fisiopatologia , Articulação do Punho/cirurgia , Adulto Jovem
20.
Clin Exp Ophthalmol ; 48(1): 89-97, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31581356

RESUMO

Intraocular lens (IOL) opacification is an infrequent complication of cataract surgery. Surface analysis has demonstrated that the opacification of IOLs is related to calcium or phosphate precipitation on or within the lenses, but the associated mechanisms are unknown, and the scientific literature is heterogeneous and limited to case series and retrospective studies. The purpose of this systematic review was to analyse the most frequent conditions associated with opacification of IOLs reported by studies. A search was carried out using the PubMed MEDLINE, Web of Science and Scopus databases. The quality of the studies selected was evaluated using the Pierson tool. The search provided a total of 811 articles, of which 39 were selected following the inclusion and exclusion criteria. The most common opacified lenses were hydrophilic IOLs according to our analysis. The mean time of appearance of lens opacification was 14.93 ± 17.82 months. The most frequent conditions associated with opacification of the IOLs were Descemet Stripping with Automated Endothelial Keratoplasty (DSAEK/DSEK) and diabetes mellitus (DM), followed by pars plana vitrectomy (PPV), blood hypertension (HT), and glaucoma. Concerning the quality analysis, the mean score was 7.00 ± 1.43 (scoring range from 0 to 10), indicating an acceptable quality of the case reports and retrospective studies. In conclusion, DSAEK/DSEK, DM, PPV, glaucoma and hypertension are conditions with potential risk of IOL opacification after cataract surgery, especially when implanting hydrophilic acrylic IOLs.


Assuntos
Lentes Intraoculares/efeitos adversos , Complicações Pós-Operatórias , Falha de Prótese/etiologia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/efeitos adversos , Remoção de Dispositivo , Complicações do Diabetes , Glaucoma/complicações , Humanos , Hipertensão/complicações , Fatores de Risco , Fatores de Tempo , Vitrectomia/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa