RESUMO
AIM: Natural orifice specimen extraction (NOSE) in left-sided colorectal surgery requires application of the circular stapler anvil to the proximal bowel without exteriorization through an additional abdominal incision. We describe an intracorporeal method to secure the stapler anvil, termed the intracorporeal antimesenteric ancillary trocar (IAAT) technique. METHOD: The ancillary trocar is attached to the stapler anvil before introduction into the abdominal cavity through the anal or vaginal orifice. The colon is incised before the trocar spike is brought out through the antimesenteric surface 3-4 cm within the cut edge. A linear stapler is used to seal the bowel end. The ancillary trocar is detached and retrieved via the NOSE conduit. Following the NOSE procedure, a side-to-end colorectal anastomosis is performed with the transanal circular stapler. RESULTS: Ten consecutive patients underwent elective left-sided colorectal resection with IAAT for NOSE (seven transanal, three transvaginal) from January to June 2023. Median age and body mass index were 66 (range 47-74) years and 24.3 (range 17.9-30.8) kg/m2 respectively. Two (20%) patients underwent sigmoid colectomy for sigmoid volvulus while eight (80%) underwent anterior resection for colorectal cancer. Median operating time, operative blood loss and postoperative length of hospital stay were 170 (range 140-240) min, 20 (range 10-40) mL and 1 (range 1-3) day respectively. There were no postoperative complications, readmissions or reoperations. Median follow-up duration was 3 (range 1-6) months. CONCLUSION: The IAAT double-stapling side-to-end anastomotic technique is safe and feasible for patients undergoing left-sided colorectal resection with NOSE, resulting in good outcomes.
Assuntos
Anastomose Cirúrgica , Colectomia , Cirurgia Endoscópica por Orifício Natural , Humanos , Feminino , Pessoa de Meia-Idade , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/instrumentação , Idoso , Masculino , Cirurgia Endoscópica por Orifício Natural/métodos , Cirurgia Endoscópica por Orifício Natural/instrumentação , Colectomia/métodos , Colectomia/instrumentação , Colo/cirurgia , Instrumentos Cirúrgicos , Vagina/cirurgia , Grampeadores Cirúrgicos , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Reto/cirurgia , Duração da CirurgiaRESUMO
AIM: Creation of an overlapped anastomosis using handsewn sutures for common enterotomy is very popular in robotic right colectomy (RRC) with intracorpareal anastomosis (IA). The aim of this study is to present a simple method for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in RRC with IA. METHOD: The distal ileum and proximal colon were put in overlapping positions. Enterotomies were created 2 cm proximal to the ileal stump and 8 cm distal to the colonic stump on the antimesenteric side. Subsequently, a 60 mm linear stapler with a reinforced bioabsorbable material was inserted into each lumen and fired. Finally, the bowel was elevated while holding the bioabsorbable material, and the common enterotomy was grasped with the robotic instrument in the middle and closed using a linear stapler with a reinforced bioabsorbable material. RESULTS: This technique was applied to 10 patients with tumours of the caecum, ascending colon, or transverse colon. The median operating time, anastomosis construction time, blood loss, and postoperative stay were 281 min (range 228-459 min), 12 min (range 11-17 min), 10 mL (range 0-110 mL), and 10 days (range 8-15 days), respectively. No adverse intraoperative events were observed. Postoperatively, one patient developed chylous ascites, but there were no other complications. CONCLUSION: The simple technique for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis appears to be safe and feasible.
Assuntos
Implantes Absorvíveis , Anastomose Cirúrgica , Colectomia , Neoplasias do Colo , Íleo , Procedimentos Cirúrgicos Robóticos , Grampeadores Cirúrgicos , Colectomia/métodos , Colectomia/instrumentação , Humanos , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Neoplasias do Colo/cirurgia , Íleo/cirurgia , Procedimentos Cirúrgicos sem Sutura/métodos , Procedimentos Cirúrgicos sem Sutura/instrumentação , Duração da Cirurgia , Colo/cirurgia , Resultado do Tratamento , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Adulto , Tempo de InternaçãoRESUMO
BACKGROUND: The objective of this study was to compare the anastomotic leak rates between powered and manual circular staplers in elective left-sided colorectal resections. METHODS: A retrospective cohort study of elective left-sided colorectal resections before and after implementation of a powered circular stapler at a tertiary care center was conducted. The manual stapler group consisted of consecutive resections performed between January 2016 to December 2016 and the powered stapler group, between September 2021 and December 2022. Primary outcome was 30-day anastomotic leak rate. A chi-squared analysis was performed to compare anastomotic leak rates. Factors associated with anastomotic leak were examined. RESULTS: Two-hundred forty-seven patients were included: 154 in the manual stapler group and 93 in the powered stapler group. Mean (SD) age was 60 (15) years old, 37.7% were female and 72.9% of resections were performed for malignancy. Both groups had similar patient characteristics and surgical technique. Overall leak rate was 2.0% in the manual stapler group and 10.8% in the powered stapler group. The powered staplers were found to have 6.06 times the odds of leak compared to manual staplers (95% CI, 1.62-22.65; p = 0.01). None of the other factors were found to be associated with anastomotic leak. CONCLUSIONS: Patients who had left-sided colorectal anastomosis had higher anastomotic leak rates with powered compared to manual circular staplers. This finding is contrary to previous retrospective studies that found lower leak rates with powered staplers.
Assuntos
Fístula Anastomótica , Procedimentos Cirúrgicos Eletivos , Grampeadores Cirúrgicos , Grampeamento Cirúrgico , Humanos , Fístula Anastomótica/prevenção & controle , Fístula Anastomótica/etiologia , Fístula Anastomótica/epidemiologia , Feminino , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Idoso , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/instrumentação , Colectomia/métodos , Colectomia/efeitos adversos , AdultoRESUMO
BACKGROUND: Since the introduction of powered circular staplers in colorectal surgery, there has been growing interest in their impact on reducing complications, particularly anastomotic leakage. This study compared short-term postoperative outcomes between powered and manual circular staplers. METHODS: This retrospective study included colorectal cancer patients at the tertiary referral center from April to October 2023 who underwent anterior or low anterior resection (LAR) using a circular stapler. According to energy source, patients were divided into powered and manual groups, which used two powered and four types of manual staplers, respectively. All open, laparoscopic, and robotic approaches were included. Propensity score matching (PSM) analysis was used to reduce selection bias. Postoperative complications within 30 days, especially for anastomosis-related complications, were compared between the groups. RESULTS: Among 511 patients, the powered group was 161 (32%). After PSM, 143 pairs of 286 patients were analyzed. The proportions of LAR were 53.8% and 51.0%, and initial diverting stoma rates were 23.1% and 22.4% for the Powered and Manual groups, respectively. Comprehensive complication rates were similar between the Powered group and the Manual group, without statistical significance (13.3% vs. 21.0%, P = 0.063). Anastomotic leakage was not different between the Powered and Manual groups (4.2% vs. 4.9%, P = 0.782). There was no significant difference in other complications, including anastomotic bleeding, ileus, surgical site infection, and intra-abdominal hematoma. CONCLUSIONS: The study implies that powered circular staplers may not significantly reduce postoperative complications, including anastomotic leakages, compared to manual staplers in colorectal surgery of high-volume centers.
Assuntos
Fístula Anastomótica , Neoplasias Colorretais , Grampeadores Cirúrgicos , Humanos , Fístula Anastomótica/prevenção & controle , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/etiologia , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Neoplasias Colorretais/cirurgia , Idoso , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/instrumentação , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Laparoscopia/métodos , Laparoscopia/efeitos adversosRESUMO
BACKGROUND: The growing use of staplers, manual and powered, especially in minimally invasive surgeries, necessitates evaluating their efficacy in gastrointestinal and thoracic surgeries. Parameters analysed include anastomotic and air leakage rates, bleeding, infection, cost, and operative duration. METHODS: We searched Cochrane Library, CINAHL, EMBASE, PubMed, and Web of Science using terms like "surgical staplers," "manual staplers," "automatic staplers," and "powered staplers." We assessed study quality using the Joanna Briggs Institute (JBI) Critical Appraisal tools and conducted meta-analysis using Review Manager software. RESULTS: A total of 43,104 patients with a mean age of 60.8 were involved in the studies. The meta-analysis revealed a significant reduction in anastomotic leaks in GI surgery patients (OR 0.31, p = 0.0001) and a significant decrease in postoperative air leakage in thoracic surgery patients (OR 0.65, p = 0.05) when powered staplers were employed. Additionally, we observed a significant decline in hemostasis-related complications for both thoracic and GI surgeries (OR 0.48, p = 0.002) with the use of powered staplers. Although individually costlier than manual staplers, powered staplers significantly decreased total hospitalisation costs (MD -1725.82, p < 0.00001) amoungst the thoracic surgeries, due to the cost saved on remedying the lower rate of complications compared to manual staplers. It also decreased the average operative times in thoracic and GI surgeries, although not significant (p = 0.06, p = 0.07 respectively). CONCLUSION: Powered staplers surpass manual staplers by reducing operative duration, total hospital costs, and complications like anastomotic leaks and bleeding. Hence, they are poised to become the preferred alternative in future surgeries.
Assuntos
Grampeadores Cirúrgicos , Humanos , Grampeamento Cirúrgico/instrumentação , Grampeamento Cirúrgico/economia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Procedimentos Cirúrgicos Torácicos/instrumentação , Desenho de Equipamento , Fístula Anastomótica/prevenção & controle , Fístula Anastomótica/etiologia , Procedimentos Cirúrgicos do Sistema Digestório/instrumentação , Duração da CirurgiaRESUMO
BACKGROUND: Pancreaticoduodenectomy is a highly difficult and invasive type of gastrointestinal surgery. Prevention of postoperative pancreatic fistula is important, and this may be possible by the stapler method. METHODS: STRAP-PD is a single center randomized controlled trial. We compare a method of transecting the pancreatic parenchyma in pancreaticoduodenectomy using a surgical stapler device with a conventional transecting method using energy devices (e.g., scalpel, ultrasonic coagulator and incision devices). Patients with soft pancreas who are scheduled to undergo pancreaticoduodenectomy are randomized to arm A (conventional method) or arm B (stapler method). We aim to examine the safety and usefulness of dissection by the automatic suture device, with attention to the rate of pancreatic fistula ISGPF grade B or C and to postoperative complications. This is a single-center randomized study, which began in September 2023 at Wakayama Medical University Hospital. DISCUSSION: Pancreatic parenchymal transection is typically performed either by direct incision using a scalpel or by employing energy devices such as ultrasonic coagulating cutting devices during pancreaticoduodenectomy. In a prospective pilot study, we conducted pancreatic parenchymal transection in 20 consecutive normal pancreatic cases during pancreaticoduodenectomy, observing postoperative pancreatic fistula grade B in one case (5%). Traditional methods involving scalpel incision or the use of ultrasonic coagulating cutting devices have been historically favored but perceived as technically challenging, and they have been reliant upon the surgeon's skill. Notably, relatively high incidences of postoperative pancreatic fistula among patients with soft pancreas have also been observed. Our proposed stapler method may therefore be a useful method responsible for reducing the development of pancreatic fistula. This method would be as part of minimally-invasive surgery for pancreaticoduodenectomy. It uses an endoscopic linear stapler to cut the pancreatic parenchyma, so it is likely to be more convenient than conventional methods and can be used universally. TRIAL REGISTRATION: University Hospital Medical Information Network Clinical Trials Registry, UMIN000052089. the Registration Date on 1st September 2023.
Assuntos
Pâncreas , Fístula Pancreática , Pancreaticoduodenectomia , Pancreaticoduodenectomia/métodos , Pancreaticoduodenectomia/efeitos adversos , Humanos , Estudos Prospectivos , Pâncreas/cirurgia , Fístula Pancreática/prevenção & controle , Fístula Pancreática/etiologia , Fístula Pancreática/epidemiologia , Projetos Piloto , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Grampeadores Cirúrgicos , Ensaios Clínicos Controlados Aleatórios como Assunto , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Resultado do Tratamento , Masculino , FemininoRESUMO
BACKGROUND: Colorectal anastomotic leakage causes severe consequences for patients and healthcare system as it will lead to increased consumption of hospital resources and costs. Technological improvements in anastomotic devices could reduce the incidence of leakage and its economic impact. The aim of the present study was to assess if the use of a new powered circular stapler is cost-effective. METHOD: This observational study included patients undergoing left-sided circular stapled colorectal anastomosis between January 2018 and December 2021. Propensity score matching was carried out to create two comparable groups depending on whether the anastomosis was performed using a manual or powered circular device. The rate of anastomotic leakage, its severity, the consumption of hospital resources, and its cost were the main outcome measures. A cost-effectiveness analysis comparing the powered circular stapler versus manual circular staplers was performed. RESULTS: A total of 330 patients were included in the study, 165 in each group. Anastomotic leakage rates were significantly different (p = 0.012): 22 patients (13.3%) in the manual group versus 8 patients (4.8%) in the powered group. The effectiveness of the powered stapler and manual stapler was 98.27% and 93.69%, respectively. The average cost per patient in the powered group was 6238.38, compared with 9700.12 in the manual group. The incremental cost-effectiveness ratio was - 74,915.28 per patient without anastomotic complications. CONCLUSION: The incremental cost of powered circular stapler compared with manual devices was offset by the savings from lowered incidence and cost of management of anastomotic leaks.
Assuntos
Anastomose Cirúrgica , Fístula Anastomótica , Colo , Análise Custo-Benefício , Reto , Grampeadores Cirúrgicos , Grampeamento Cirúrgico , Humanos , Fístula Anastomótica/prevenção & controle , Fístula Anastomótica/economia , Fístula Anastomótica/etiologia , Feminino , Grampeadores Cirúrgicos/economia , Masculino , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/economia , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Pessoa de Meia-Idade , Idoso , Incidência , Grampeamento Cirúrgico/economia , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/instrumentação , Colo/cirurgia , Reto/cirurgia , Pontuação de Propensão , Adulto , Análise de Custo-EfetividadeRESUMO
Surgical stapling has evolved significantly over time, with the primary goal of improving patient outcomes. This study describes the technological advancements in surgical stapling from the perspective of staple and cartridge design, assessing the impact of staple design when it changes from the traditional B form (also known as 2D staple form) to a three-dimensional form (known as 3D staple form). The change in configuration helps compress a larger surface area of the tissue. The 3D configuration is designed to optimize compression not only underneath each staple but also across staples and multiple staple lines, including both stapled and unstapled regions of the tissue. By achieving more evenly distributed compression throughout the staple line, there is potential for reduced leak paths. The study demonstrates that the 3D staple form in surgical stapling results in more evenly distributed compression. In the future, this advanced technology should seamlessly integrate into emerging systems such as the surgical robot, enabling continued progress in surgical instrumentation and ultimately in surgical care.
Assuntos
Desenho de Equipamento , Grampeamento Cirúrgico , Suturas , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Humanos , Grampeadores CirúrgicosRESUMO
AIM: To compare the biomechanical properties of three different sternal closure techniques in a 3D-printed bone model of a sternum from a 30-kg dog. METHODS: Median sternotomy was performed on a total of 90 three-dimensional (3D) copies of a polycarbonate (PC) model of a sternum, generated from the CT images of the sternum of a 30-kg German Shepherd dog. Three different methods were used to repair the sternotomies: polydioxanone suture (group PDS, n = 30), stainless steel bone staples (group SS, n = 30), and nitinol bone staples (group NS, n = 30). Each repair method was tested by applying tensile force in one of three ways (longitudinally, laterally, or torsionally) resulting in a sample size of n = 10 for each repair method-loading combination. In all experiments, the loads at 1-mm and 2-mm gap formation, failure, and the displacement at the failure point were measured. RESULTS: In lateral distraction and longitudinal shear tests, NS and SS staple repairs required application of significantly greater force than PDS across all displacement criteria (1 and 2 mm). NS exhibited significantly greater failure load than PDS. In torsion tests, NS required significantly greater application of force compared to SS or PDS at all displacement criteria (1 and 2 mm) and exhibited a greater failure load than PDS. In terms of displacement at failure point, PDS suture showed more displacement than SS or NS across all experiments (laterally, longitudinally, torsionally). CONCLUSIONS: In this study, bone staples were mechanically superior to PDS suture in median sternotomy closure using 3D-printed bone model in terms of 1-mm, 2-mm displacement loads, and displacement at failure. NS had a higher failure load than PDS under lateral, longitudinal, and torsional distraction. CLINICAL RELEVANCE: These study results imply that bone staples can be considered as an alternative surgical method for median sternotomy closure in dogs.
Assuntos
Impressão Tridimensional , Esternotomia , Suturas , Animais , Suturas/veterinária , Cães , Fenômenos Biomecânicos , Esternotomia/veterinária , Esternotomia/métodos , Grampeamento Cirúrgico/veterinária , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Esterno/cirurgia , Modelos Anatômicos , Técnicas de Sutura/veterináriaRESUMO
BACKGROUND AND PURPOSE: The primary aim of this systematic review and meta-analysis was to evaluate the success rate of 3 different epiphysiodesis techniques with implant usage for the treatment of leg-length discrepancy (LLD) in the pediatric population. The secondary aim was to address effectiveness (final LLD) and the reported complications of staples, tension-band plates (TBP), and percutaneous epiphysiodesis screws (PETS). METHODS: In this systematic review we searched MEDLINE (PubMed), Embase, Cochrane Library, Web of Science and Scopus for studies on skeletally immature patients with LLD treated with epiphysiodesis with an implant. The extracted outcome categories were effectiveness of epiphysiodesis (LLD measurements pre-/postoperatively, successful/unsuccessful) and complications that were graded on severity. RESULTS: 44 studies (2,184 patients) were included. 455 underwent epiphysiodesis with PETS, 578 patients with TBP, and 1,048 with staples. Successful epiphysiodesis was reported in 76% (95% confidence interval [CI] 61-89) with PETS (9 studies), 67% (CI 54-79) with TBP (10 studies), and 51% (CI 28-65) with Blount staples (8 studies). From pooled analysis, the severe complications rate was 7% for PETS, 17% for TBP, and 16% for Blount staples. Angular deformity was reported in 4% after PETS, 10% after TBP, and 17% after Blount staples. CONCLUSION: Our results showed that epiphysiodesis with PETS implants was the most successful technique. PETS had a higher success rate, fewer severe complications, and a lower proportion with angular deformity.
Assuntos
Placas Ósseas , Parafusos Ósseos , Epífises , Desigualdade de Membros Inferiores , Humanos , Desigualdade de Membros Inferiores/cirurgia , Epífises/cirurgia , Criança , Resultado do Tratamento , Suturas , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/instrumentaçãoRESUMO
BACKGROUND: The International Transanal Total Mesorectal Excision Registry group showed that transanal total mesorectal excision included clinical issues regarding anastomosis-related complications. OBJECTIVE: This study evaluated anastomotic complications in patients whose anastomoses were created with the stapler plus reinforced sutures procedure after transanal total mesorectal excision for low rectal cancer. DESIGN: This was a retrospective single-center study. SETTING: The study was conducted at the National Cancer Center Hospital East, Japan. PATIENTS: Between June 2016 and December 2019, 150 patients underwent transanal total mesorectal excision for low rectal cancer. Stapled anastomosis was performed for 55 patients, and coloanal handsewn anastomosis was performed for 95 patients. Blood perfusion of the colon was routinely evaluated with intraoperative indocyanine green fluorescence angiography. All patients who underwent stapled anastomosis received additional handsewn sutures on all rounds of the stapled line. Patients who underwent intersphincteric resection were excluded. MAIN OUTCOME MEASURES: The anastomosis-related complications were compared between the groups. RESULTS: Early anastomotic leakage was found in one (1.8%) and eight (8.4%) patients in the stapled group and handsewn group. Overall anastomosis-related complications, pelvic abscess, and anastomotic stenosis were significantly less frequent in the stapled group (p < 0.001, p < 0.048, and p < 0.032). Incomplete donuts after the stapled anastomosis were observed in 9 patients (16.4%); however, we reinforced all around the stapled line in these patients, and this reduced the subsequent occurrence of anastomotic leakage. LIMITATIONS: First, this was a retrospective single-center study that was not randomized or controlled. Second, there were chronological differences regarding the anastomotic method between the two groups. Third, our study included a relatively small number of patients who received preoperative chemoradiotherapy. CONCLUSIONS: Stapled anastomosis with reinforced handsewn sutures resulted in fewer anastomosis-related complications than did coloanal handsewn anastomosis after transanal total mesorectal excision for low rectal cancer; thus, the former may be superior and should be the preferred method, when technically possible. See Video Abstract at http://links.lww.com/DCR/B749.COMPLICACIONES RELACIONADAS CON LAS ANASTOMOSIS ENGRAMPADAS Y REFORZADAS CON SUTURAS EN LA EXCISIÓN TOTAL DEL MESORRECTO POR VÍA TRANSANAL EN CASOS DE CÁNCER DE RECTO BAJO: ESTUDIO RETROSPECTIVO UNICÉNTRICO. ANTECEDENTES: El grupo del Registro Internacional de Excisión Total del Mesorrecto por vía Transanal mostró que la excisión total mesorrectal transanal incluía problemas clínicos relacionados a las complicaciones involucradas con la anastomosis. OBJETIVO: Se evaluaron las complicaciones anastomóticas en pacientes cuyas anastomosis se realizaron con engrampadora reforzada de suturas después de la excisión total de l mesorrecto por vía transanal en casos de cáncer de recto bajo. DISEO: Estudio retrospectivo unicéntrico. AJUSTE: El Hospital del Centro Nacional del Cáncer del Este, Japón. PACIENTES: Entre junio de 2016 y diciembre de 2019, 150 pacientes se sometieron a excisión total del mesorrecto por vía transanal en casos de cáncer de recto bajo. Se realizó anastomosis con engrampadora en 55 y anastomosis coloanal suturada a mano en 95 pacientes. La perfusión tisular sanguínea del colon operado se evaluó de forma rutinaria con angiografía de fluorescencia con verde de indocianina intraoperatoria. Todos los pacientes que se sometieron a anastomosis con grapas recibieron suturas realizadas a mano adicionales sobre la totalidad de la línea de grapas. Se excluyeron los pacientes sometidos a resección interesfintérica. PRINCIPALES MEDIDAS DE RESULTADO: Las complicaciones relacionadas con la anastomosis se compararon entre los grupos. RESULTADOS: Se encontró fuga anastomótica temprana en 1 (1.8%) y 8 (8.4%) pacientes en el grupo de engrampado y en el grupo suturado a mano, respectivamente. En general, las complicaciones relacionadas con la anastomosis, el absceso pélvico y la estenosis anastomótica fueron significativamente menos frecuentes en el grupo con grapas (p < 0.001, p < 0.048, p < 0.032, respectivamente). Se observaron donas incompletas después de la anastomosis grapada en 9 pacientes (16,4%); sin embargo, reforzamos todo alrededor de la línea de grapas en estos pacientes, y esto redujo la aparición posterior de fugas anastomóticas. LIMITACIONES: Inicialmente, este fue un estudio retrospectivo de un solo centro que no fue aleatorizado ni controlado. En segundo lugar, hubo diferencias cronológicas con respecto al método anastomótico entre los dos grupos. En tercer lugar, nuestro estudio incluyó un número relativamente pequeño de pacientes que recibieron quimiorradioterapia preoperatoria. CONCLUSIONES: La anastomosis engrapada reforzada con suturas realizadas a mano dio como resultado menos complicaciones relacionadas con la anastomosis que la anastomosis coloanal suturada a mano después de la excisión total del mesorrecto por vía transanal en casos de cáncer de recto bajo; por tanto, el primero puede ser superior y debería ser el método preferido, cuando sea técnicamente posible. Consulte Video Resumen en http://links.lww.com/DCR/B749. (Traducción-Dr. Xavier Delgadillo).
Assuntos
Anastomose Cirúrgica/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Protectomia/efeitos adversos , Neoplasias Retais/cirurgia , Grampeamento Cirúrgico/efeitos adversos , Suturas/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Anastomose Cirúrgica/instrumentação , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Neoplasias Retais/patologia , Estudos Retrospectivos , Grampeamento Cirúrgico/instrumentaçãoRESUMO
PURPOSE: Postoperative pancreatic fistula (POPF) remains the most clinically relevant complication of laparoscopic distal pancreatectomy (LDP). The present study evaluated the efficacy of the "slow firing method" using a reinforced triple-row stapler (Covidien, Tokyo, Japan) during LDP. METHODS: This retrospective single-center study included 73 consecutive patients who underwent LDP using the slow firing method. A black cartridge was used in all patients. The primary endpoint was the rate of clinically relevant POPF (CR-POPF) after LDP. Secondary endpoints included perioperative outcomes and factors associated with CR-POPF as well as the correlation between the transection time and thickness of the pancreas. RESULTS: Four patients (5.5%) developed CR-POPF (grade B). Overall morbidity rates, defined as grade ≥ II and ≥ III according to the Clavien-Dindo classification, were 21 and 11%, respectively. The median postoperative hospital stay was 10 days. Preoperative diabetes (13.6 vs. 0.2%, P = 0.044) and thickness of the pancreas ≥ 15 mm (13.8% vs. 0%, P = 0.006) were identified as independent risk factors for CR-POPF. The median transection time was 16 (8-29) min. CONCLUSION: The slow firing method using a reinforced triple-row stapler for pancreatic transection is simple, safe, and effective for preventing CR-POPF after LDP.
Assuntos
Laparoscopia/métodos , Pancreatectomia/métodos , Fístula Pancreática/prevenção & controle , Complicações Pós-Operatórias/prevenção & controle , Grampeadores Cirúrgicos , Grampeamento Cirúrgico/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Glicosídeos , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Pregnanos , Fatores de Risco , Segurança , Grampeamento Cirúrgico/instrumentação , Resultado do Tratamento , Adulto JovemRESUMO
BACKGROUND: Postoperative pancreatic fistula is the leading cause of morbidity after distal pancreatectomy. Strategies investigated to reduce the incidence have been disappointing. Recent data showed a reduction in postoperative pancreatic fistula with the use of synthetic mesh reinforcement of the staple line. METHODS: An RCT was conducted between May 2014 and February 2016 at four tertiary referral centres in Sweden. Patients scheduled for distal pancreatectomy were eligible. Enrolled patients were randomized during surgery to stapler transection with biological reinforcement or standard stapler transection. Patients were blinded to the allocation. The primary endpoint was the development of any postoperative pancreatic fistula. Secondary endpoints included morbidity, mortality, and duration of hospital stay. RESULTS: Some 107 patients were randomized and 106 included in an intention-to-treat analysis (56 in reinforced stapling group, 50 in standard stapling group). No difference was demonstrated in terms of clinically relevant fistulas (grade B and C): 6 of 56 (11 per cent) with reinforced stapling versus 8 of 50 (16 per cent) with standard stapling (P = 0.332). There was no difference between groups in overall postoperative complications: 45 (80 per cent) and 39 (78 per cent) in reinforced and standard stapling groups respectively (P = 0.765). Duration of hospital stay was comparable: median 8 (range 2-35) and 9 (2-114) days respectively (P = 0.541). CONCLUSION: Biodegradable stapler reinforcement at the transection line of the pancreas did not reduce postoperative pancreatic fistula compared with regular stapler transection in distal pancreatectomy. Registration number: NCT02149446 (http://www.clinicaltrials.gov).
Assuntos
Implantes Absorvíveis , Pancreatectomia/efeitos adversos , Fístula Pancreática/prevenção & controle , Grampeamento Cirúrgico/instrumentação , Grampeamento Cirúrgico/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Fístula Pancreática/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Telas CirúrgicasRESUMO
Accumulation of experience and advances in techniques and instruments have enabled surgeons to perform video-assisted thoracic surgery (VATS) safely for sublobar resection, including segmentectomy and wedge resection. A key to successful VATS sublobar resection is to have adequate resection margins and the appropriate use of articulated surgical staplers is essential for this purpose. The SigniaTM stapling system (Covidien Japan, Tokyo) has been used extensively in the fields of thoracic surgery. Its features include high maneuverability with fully powered articulation, rotation, clamping, and firing, which the surgeon can control with one hand. We introduce the "sliding technique" using the SigniaTM system, which allows for adjustment of the resection lines of the pulmonary parenchyma to optimize safe surgical margins with minimal stapler movement, and without repetitively moving the stapler in and out of the pleural cavity, during VATS sublobar resection.
Assuntos
Neoplasias Pulmonares/cirurgia , Pulmão/cirurgia , Margens de Excisão , Pneumonectomia/instrumentação , Pneumonectomia/métodos , Grampeadores Cirúrgicos , Grampeamento Cirúrgico/instrumentação , Grampeamento Cirúrgico/métodos , Cirurgia Torácica Vídeoassistida/instrumentação , Cirurgia Torácica Vídeoassistida/métodos , Humanos , SegurançaRESUMO
PURPOSE: Using a circular stapler to create an anastomosis for esophagogastrostomy after esophagectomy is well accepted; however, it remains uncertain if the greater curvature (GC) or lesser curvature (LC) of the gastric conduit is better for the anastomosis. We conducted this prospective study to compare the integrity of esophagogastrostomy between the esophagus and the GC or LC side of the gastric conduit. METHODS: The subjects of this study were 70 patients who underwent esophagectomy and were randomized to a "GC" group and an "LC" group (n = 35 each). The primary and secondary end points were anastomotic leakage (AL) and anastomotic stricture (AS), respectively. RESULTS: The overall AL rate was 22.1%, without a significant difference between the groups. Stump leakage developed in eight of nine patients in the GC group, whereas leakage developed at the esophagogastric anastomosis in five of six patients in the LC group. The rate of stump leakage was significantly higher than that of esophagogastric AL in the GC group. The overall AS rate was 4.4%, with a significant difference between the groups (0% in the GC group vs. 9.1% in the LC group). CONCLUSIONS: AL rates were comparable in the two groups, but the sites of leakage were significantly different.
Assuntos
Neoplasias Esofágicas/cirurgia , Esofagectomia/métodos , Esôfago/cirurgia , Gastrostomia/métodos , Grampeadores Cirúrgicos , Grampeamento Cirúrgico/instrumentação , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/etiologia , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Grampeadores Cirúrgicos/efeitos adversos , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/métodos , Resultado do TratamentoRESUMO
BACKGROUND: Recently, due to increasing reports of stenosis after esophagojejunostomy created using circular staplers and a transorally inserted anvil (OrVil™) following laparoscopic proximal gastrectomy (LPG) and total gastrectomy (LTG), linear staplers are being used instead. We investigated our preventive procedure for esophagojejunostomy stenosis following use of circular staplers. METHODS: Since the anastomotic stenosis is considered to be mainly caused by tension in the esophageal and jejunal stumps at the anastomotic site, we have been performing procedures to relieve this tension, by cutting off the rubber band and pushing the shaft of the circular stapler toward the esophageal side, since July 2015. We retrospectively compared the incidence of anastomotic stenosis in cases of LPG and LTG performed before July 2015 (early phase, 30 cases) versus those performed after this period (later phase, 22 cases). RESULTS: Comparison of the incidence of anastomotic stenosis according to the type of surgery, LPG or LTG, and between the two time periods versus all cases, indicated a significantly lower incidence in the later phase than in the early phase (4.5 vs. 26.7%, p < 0.05), especially for LPG (0 vs. 38.5%, p < 0.05). CONCLUSIONS: It is possible to use a circular stapler during laparoscopic esophagojejunostomy, as with open surgery, if steps to reduce tension on the anastomotic site are undertaken. These procedures will contribute to the spread of safe and simple laparoscopic anastomotic techniques.
Assuntos
Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Constrição Patológica/prevenção & controle , Esôfago/cirurgia , Jejuno/cirurgia , Neoplasias Gástricas , Idoso , Anastomose Cirúrgica/instrumentação , Constrição Patológica/etiologia , Feminino , Gastrectomia/efeitos adversos , Gastrectomia/métodos , Humanos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Neoplasias Gástricas/cirurgia , Grampeamento Cirúrgico/instrumentação , Grampeamento Cirúrgico/métodosRESUMO
OBJECTIVE: To determine the influence of stapling on leakage pressures after canine partial gastrectomy. STUDY DESIGN: Ex vivo study. SAMPLE POPULATION: Gastric specimens from 24 adult canine cadavers. METHODS: Partial gastrectomy constructs were assigned to one of three closure techniques (n = 8 per group): group 1, stapled closure with a 90-mm thoracoabdominal stapling device and a 4.8-mm staple cartridge; group 2, hand-sewn double-layer inverting suture closure with 3-0 glycomer 631; and group 3, staple line reinforcement with an inverting Cushing suture pattern. Leakage and pressure testing were performed. Initial leakage pressure (ILP), maximal leakage pressure (MLP), and leakage location were recorded. Significance was set at P < .05. RESULTS: Placement of a Cushing suture (group 3) increased ILP and MLP by 3.2-fold and 2.8-fold, respectively, compared with stapled closures alone (P < .001). Constructs closed with double-layer suture closure reached ILP and MLP 4.5-fold and threefold greater, respectively, compared with those with stapled closures alone (P < .001). Maximal leakage pressure did not differ between groups 2 and 3 (P = .14). Leakage occurred from the inverting suture line in all constructs of groups 2 and 3 and from staple holes in six of eight group 1 constructs. CONCLUSION: Double-layer suture closure of canine partial gastrectomies achieved superior biomechanical properties compared with stapled closure techniques. Reinforcing staple closures with an inverting suture line improved resistance to leakage. CLINICAL SIGNIFICANCE: Reinforcing single-layer closure of partial gastrectomies with an inverting Cushing pattern is recommended to improve resistance to leakage. In vivo investigation is warranted to evaluate influence of closure technique on gastric healing, postoperative stasis, ischemic injury, and postoperative dehiscence.
Assuntos
Gastrectomia/veterinária , Grampeamento Cirúrgico/veterinária , Animais , Fenômenos Biomecânicos , Cadáver , Cães , Gastrectomia/métodos , Grampeamento Cirúrgico/instrumentaçãoRESUMO
Objective: To evaluate the safety and efficacy of stent-assisted coil embolization in patients with recurrent intracranial bifurcation aneurysms,after initial simple coiling or microsurgical clipping. Methods: Clinical data of 20 patients with recurrent intracranial bifurcation aneurysms who initially underwent simple coiling or surgical clipping and subsequently re-treated by stent-assisted coiling embolization at the Radiology Intervention Department of Huashan Hospital between March 2009 and November 2019 were collected and analyzed retrospectively.There were 9 males and 11 females,with a median age of 55.5 years (range:33 to 71 years),including 17 aneurysms initially treated with simple coiling and 3 treated with surgical clipping.All cases were re-treated with stent-assisted coiling,15 using a single stent and 5 employing two stents in a Y-configuration.Peri-and post-operative complications and outcomes were evaluated.Mann-Whitney U tests were performed to compare the follow-up duration between initial treatment and re-treatment.Student's t tests were used to compare the parent artery angles before re-treatment, after re-treatment and at the last follow-up. The parent artery angle was defined using the proximal main trunk and the stented branch. Results: Immediate complete occlusion (Raymond â ) was achieved in 18 aneurysms (90.0%) while 2 aneurysms (10.0%) had a residual neck (Raymond â ¡).The median follow-up time(M(QR)) was 8.5(16.3)months,which had no significantly different from the initial treatment follow-up duration (15.5(27.0)months)(U=157.7,P=0.25). During the follow-up period,2 aneurysms (10.0%) with immediate post-operative residual necks recanalized again,including 1 aneurysm re-treated with the Y-configuration stent.Symptomatic thromboembolic complications occurred in 6 patients,including 4 re-treated with the Y-configuration stent.No peri-operative hemorrhagic complications occurred,along with no operation-related permanent disability or death. The parent artery angle increased significantly from pre-operative(90.1±21.1)°to post-operative and the last follow-up ((115.4±28.9)° and (132.6±26.8)°);t=5.14,P<0.01;t=7.78,P<0.01). Conclusion: For recurrent intracranial bifurcation aneurysms after initial surgical clipping or simple coiling,stent assisted coil embolization is proved to be safe and can decrease recurrence rate.
Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Stents , Adulto , Idoso , Angiografia Cerebral , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/instrumentação , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Recidiva , Reoperação , Estudos Retrospectivos , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/instrumentação , Falha de Tratamento , Resultado do TratamentoRESUMO
Background: Stapled hemorrhoidopexy (Longo operation) is a infrequent technique in our area. A different concept from hemorrhoidectomy, a proportionally important raise in cost and a special training may have contributed to it. We report our long-term results with the standard technique. Methods: The data of 35 patients with symptomatic second- and third-degree hemorrhoids who had stapled hemorrhoidopexy using a PPH03 stapler, from 01 January 2012 to 04 December 2020, were retrospectively collected. The sex ratio male: female was 3:4 and the mean age 45 (range 28-60) years. The follow-up consisted in a rectal exam and evaluated anatomical recurrence or prolapse. Results: The mean operative time was 42 (30-70) min. The mean parenteral analgesic doses during the first 24 h were 1,52. The mean postoperative hospital stay was 1.55 (1-2) days. A single patient needed reoperation for a staple line bleeding, two patients had a thrombosis of internal hemorrhoids and in one patient a small prolapse was diagnosed at 3 months follow-up. No hematoma, anastomotic stenosis, persistent anal pain, tenesmus, or impaired anal continence was recorded. One patient mentioned discomfort related to the presence of staples. Patients were followed-up for 6 (1-9) years. Global satisfaction rate was 94%. Conclusion: Stapled hemorrhoidopexy procedure is a safe and feasible procedure, which necessitates few analgesics and allows an early discharge. A rigorous selection of cases and a correct surgical technique allow to obtain good long-term results and offer a high level of patients satisfaction.
Assuntos
Hemorroidas , Grampeamento Cirúrgico , Adulto , Feminino , Hemorroidas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Grampeamento Cirúrgico/instrumentação , Grampeamento Cirúrgico/métodos , Resultado do TratamentoRESUMO
BACKGROUND: The use of a small circular stapler (CS) has been reported to increase the incidence of benign anastomotic stricture of the intrathoracic anastomosis after esophagectomy, but no study has evaluated the effects of the CS size on cervical esophagogastrostomy. Based on a propensity-matched comparison, the present study was designed to determine whether the perioperative outcomes differ between 21- and 25-mm CSs after minimally invasive esophagectomy with cervical anastomosis. METHODS: From January 2015 to December 2017, 162 patients who received CS cervical esophagogastric anastomosis after minimally invasive esophagectomy for esophageal cancer were identified from our surgical database. A propensity-matched analysis was used to compare the outcomes between the 21- and 25-mm CS groups. Endpoints included anastomotic leak, dysphagia, reflux, stricture, and other major postoperative outcomes within 6 postoperative months. RESULTS: There were 69 and 93 patients in the 21- and 25-mm CS groups, respectively. Propensity matching produced 57 patients in each group. The two groups were not remarkably different in benign anastomotic stricture rate (P = 0.528). All strictures were resolved by balloon dilatation. The 25-mm CS group had a significantly longer operative time in cervical anastomosis than the 21-mm group (P = 0.005). No statistically significant differences in anastomotic leak rates, dysphagia scores, reflux scores, or other postoperative complications were noted between the two groups. CONCLUSIONS: The use of a 21-mm CS in minimally invasive esophagectomy with cervical esophagogastric anastomosis did not result in greater anastomotic stricture as compared with a 25-mm CS. The 21-mm CS was associated with a significantly shorter operative time.