Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Microvasc Res ; 136: 104164, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33831406

RESUMO

INTRODUCTION: Microcirculatory alterations are key mechanisms in sepsis pathophysiology leading to tissue hypoxia, edema formation, and organ dysfunction. Hyperspectral imaging (HSI) is an emerging imaging technology that uses tissue-light interactions to evaluate biochemical tissue characteristics including tissue oxygenation, hemoglobin content and water content. Currently, clinical data for HSI technologies in critical ill patients are still limited. METHODS AND ANALYSIS: TIVITA® Tissue System was used to measure Tissue oxygenation (StO2), Tissue Hemoglobin Index (THI), Near Infrared Perfusion Index (NPI) and Tissue Water Index (TWI) in 25 healthy volunteers and 25 septic patients. HSI measurement sites were the palm, the fingertip, and a suprapatellar knee area. Septic patients were evaluated on admission to the ICU (E), 6 h afterwards (E+6) and three times a day (t3-t9) within a total observation period of 72 h. Primary outcome was the correlation of HSI results with daily SOFA-scores. RESULTS: Serial HSI at the three measurement sites in healthy volunteers showed a low mean variance expressing high retest reliability. HSI at E demonstrated significantly lower StO2 and NPI as well as higher TWI at the palm and fingertip in septic patients compared to healthy volunteers. StO2 and TWI showed corresponding results at the suprapatellar knee area. In septic patients, palm and fingertip THI identified survivors (E-t4) and revealed predictivity for 28-day mortality (E). Fingertip StO2 and THI correlated to SOFA-score on day 2. TWI was consistently increased in relation to the TWI range of healthy controls during the observation time. Palm TWI correlated positively with SOFA scores on day 3. DISCUSSION: HSI results in septic patients point to a distinctive microcirculatory pattern indicative of reduced skin oxygenation and perfusion quality combined with increased blood pooling and tissue water content. THI might possess risk-stratification properties and TWI could allow tissue edema evaluation in critically ill patients. CONCLUSION: HSI technologies could open new perspectives in microcirculatory monitoring by visualizing oxygenation and perfusion quality combined with tissue water content in critically ill patients - a prerequisite for future tissue perfusion guided therapy concepts in intensive care medicine.


Assuntos
Imageamento Hiperespectral , Microcirculação , Imagem de Perfusão , Testes Imediatos , Sepse/diagnóstico por imagem , Pele/irrigação sanguínea , Espectroscopia de Luz Próxima ao Infravermelho , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/metabolismo , Água Corporal/metabolismo , Estudos de Casos e Controles , Estado Terminal , Feminino , Hemoglobinas/metabolismo , Humanos , Imageamento Hiperespectral/instrumentação , Masculino , Pessoa de Meia-Idade , Escores de Disfunção Orgânica , Oxigênio/metabolismo , Imagem de Perfusão/instrumentação , Projetos Piloto , Sistemas Automatizados de Assistência Junto ao Leito , Valor Preditivo dos Testes , Estudos Prospectivos , Fluxo Sanguíneo Regional , Sepse/metabolismo , Sepse/fisiopatologia , Pele/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Fatores de Tempo
2.
Dis Colon Rectum ; 64(12): 1542-1550, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33661231

RESUMO

BACKGROUND: Recent studies have clarified that near-infrared observation using indocyanine green has the advantage of evaluating perfusion of the anastomotic site, especially in rectal cancer surgery, resulting in a reduction in anastomotic leak. OBJECTIVE: The aim of this study was to evaluate the efficacy of near-infrared observation for reducing the anastomotic leak after stapled side-to-side anastomosis in colon cancer surgery. DESIGN: This was a retrospective propensity score case-matched study. SETTINGS: The study was conducted at 3 institutions in the Yokohama Clinical Oncology Group. PATIENTS: From January 2011 to December 2019, patients who underwent colon cancer surgery with stapled side-to-side anastomosis were included. MAIN OUTCOME MEASURES: The main outcome was the percentage of anastomotic leak within 30 days after surgery. RESULTS: A total of 1034 patients were collected. There were 532 patients who underwent near-infrared observation and 502 who did not. A total of 370 patients were matched to the near-infrared and non-near-infrared groups. In the near-infrared group, 12 patients (3.2%) were judged to have poor perfusion (4 patients) and no perfusion (8 patients), so the planned transection point was changed. There were no cases of anastomotic leak among these 12 patients. The anastomotic leak rates were 3.5% (13/370) in the non-near-infrared group and 0.8% (3/370) in the near-infrared group. The anastomotic leak and reoperation rates were significantly lower in the near-infrared group than in the non-near-infrared group (OR, 0.224; 95% CI, 0.063-0.794, p = 0.001; OR, 0.348; 95% CI, 0.124-0.977, p = 0.036). LIMITATIONS: Although we reduced selection bias by performing propensity score matching, this was a retrospective study and was not randomized. CONCLUSION: This large-scale case-matched study showed that assessing perfusion by near-infrared observation significantly reduced the anastomotic leak and reoperation rates after stapled side-to-side anastomosis in colon cancer surgery and may be better suited to colo-colonic anastomosis. Video Abstract at http://links.lww.com/DCR/B513.Japanese Clinical Trials Registry: UMIN-CTR000039977. EVALUACIN DEL EFECTO DE LA OBSERVACIN INTRAOPERATORIA CON INFRARROJO CERCANO SOBRE LA FUGA ANASTOMTICA DESPUS DE UNA ANASTOMOSIS LATEROLATERAL CON ENGRAPADORA EN LA CIRUGA DE CNCER DE COLON MEDIANTE EL EMPAREJAMIENTO POR PUNTAJES DE PROPENSIN: ANTECEDENTES:Estudios recientes han aclarado que la observación con infrarrojo cercano con verde de indocianina tiene la ventaja de evaluar la perfusión del sitio anastomótico, especialmente en la cirugía de cáncer de recto, lo que resulta en una reducción de la fuga anastomótica.OBJETIVO:El objetivo de este estudio fue evaluar la eficacia de la observación con infrarrojo cercano para reducir la fuga anastomótica después de una anastomosis latero-lateral con engrapadora en la cirugía de cáncer de colon.DISEÑO:Este fue un estudio retrospectivo emparejado con puntaje de propensión.AJUSTE:El estudio se llevó a cabo en tres instituciones del Grupo de Oncología Clínica de Yokohama.PACIENTES:Desde enero de 2011 hasta diciembre de 2019, se incluyeron pacientes que se sometieron a cirugía de cáncer de colon con anastomosis latero-lateral con engrapadora.PRINCIPALES MEDIDAS DE RESULTADO:El resultado principal fue el porcentaje de fuga anastomótica dentro de los 30 días posteriores a la cirugía.RESULTADOS:Se recogió un total de 1034 pacientes. Hubo 532 pacientes que se sometieron a observación con infrarrojo cercano y 502 que no. Un total de 370 pacientes fueron emparejados con los grupos de infrarrojo cercano y no infrarrojo cercano. En el grupo de infrarrojo cercano, se consideró que 12 casos (3,2%) tenían mala perfusión (4 casos) y ninguna perfusión (8 casos), por lo que se cambió el punto de transección planificado. No hubo casos de fuga anastomótica entre estos 12 casos. Las tasas de fuga anastomótica fueron del 3,5% (13/370) en el grupo sin infrarrojo cercano y del 0,8% (3/370) en el grupo con infrarrojo cercano. Las tasas de fuga anastomótica y de reintervención fueron significativamente menores en el grupo con infrarrojo cercano que en el grupo sin infrarrojo cercano (razón de posibilidades 0,224, intervalo de confianza del 95% 0,063-0,794, p = 0,001; razón de posibilidades 0,348, intervalo de confianza del 95% 0,124 -0,977, p = 0,036, respectivamente).LIMITACIONES:Aunque se redujo el sesgo de selección al realizar el emparejamiento por puntaje de propensión, este fue un estudio retrospectivo y no fue aleatorio.CONCLUSIÓN:Este estudio de casos emparejados a gran escala demostró que la evaluación de la perfusión mediante la observación con infrarrojo cercano redujo significativamente la fuga anastomótica y las tasas de reintervención después de la anastomosis latero-lateral con engrapadora en la cirugía de cáncer de colon y puede ser más adecuada para la anastomosis colo-colónica. Consulte Video Resumen en http://links.lww.com/DCR/B513.Registro japonés de ensayos clínicos: UMIN-CTR000039977.


Assuntos
Anastomose Cirúrgica/efeitos adversos , Fístula Anastomótica/diagnóstico por imagem , Neoplasias do Colo/cirurgia , Imagem Óptica/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/prevenção & controle , Estudos de Casos e Controles , Feminino , Humanos , Verde de Indocianina/administração & dosagem , Verde de Indocianina/metabolismo , Cuidados Intraoperatórios/instrumentação , Masculino , Imagem Óptica/métodos , Imagem de Perfusão/instrumentação , Pontuação de Propensão , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Suturas/efeitos adversos
3.
Cerebrovasc Dis ; 50(2): 208-215, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33596563

RESUMO

BACKGROUND: Postoperative cerebral hyperperfusion syndrome (CHS) may occur after superficial temporal artery (STA)-middle cerebral artery (MCA) bypass for moyamoya disease (MMD). Predicting postoperative CHS is challenging; however, we previously reported the feasibility of using a hyperspectral camera (HSC) for monitoring intraoperative changes in brain surface hemodynamics during STA-MCA bypass. OBJECTIVE: To investigate the utility of HSC to predict postoperative CHS during STA-MCA bypass for patients with MMD. METHODS: Hyperspectral images of the cerebral cortex of 29 patients with MMD who underwent STA-MCA bypass were acquired by using an HSC before and after anastomosis. We then analyzed the changes in oxygen saturation after anastomosis and assessed its correlation with CHS. RESULTS: Five patients experienced transient neurological deterioration several days after surgery. 123I-N-Isopropyl-iodoamphetamine single-photon emission computed tomography scan results revealed an intense, focal increase in cerebral blood flow at the site of anastomosis without any cerebral infarction. Patients with CHS showed significantly increased oxygen saturation (SO2) in the cerebral cortex after anastomosis relative to those without CHS (33 ± 28 vs. 8 ± 14%, p < 0.0001). Receiver operating characteristic analysis results show that postoperative CHS likely occurs when the increase rate of cortical SO2 value is >15% (sensitivity, 85.0%; specificity, 81.3%; area under curve, 0.871). CONCLUSIONS: This study indicates that hyperspectral imaging of the cerebral cortex may be used to predict postoperative CHS in patients with MMD undergoing STA-MCA bypass.


Assuntos
Córtex Cerebral/irrigação sanguínea , Revascularização Cerebral , Circulação Cerebrovascular , Imageamento Hiperespectral , Artéria Cerebral Média/cirurgia , Doença de Moyamoya/cirurgia , Imagem de Perfusão , Artérias Temporais/cirurgia , Adolescente , Adulto , Idoso , Revascularização Cerebral/efeitos adversos , Criança , Pré-Escolar , Feminino , Hemodinâmica , Humanos , Imageamento Hiperespectral/instrumentação , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/fisiopatologia , Doença de Moyamoya/diagnóstico por imagem , Doença de Moyamoya/fisiopatologia , Imagem de Perfusão/instrumentação , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Artérias Temporais/diagnóstico por imagem , Artérias Temporais/fisiopatologia , Resultado do Tratamento , Adulto Jovem
4.
J Cardiovasc Magn Reson ; 22(1): 7, 2020 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-31959203

RESUMO

BACKGROUND: 4D flow cardiovascular magnetic resonance (CMR) enables visualization of complex blood flow and quantification of biomarkers for vessel wall disease, such as wall shear stress (WSS). Because of the inherently long acquisition times, many efforts have been made to accelerate 4D flow acquisitions, however, no detailed analysis has been made on the effect of Cartesian compressed sensing accelerated 4D flow CMR at different undersampling rates on quantitative flow parameters and WSS. METHODS: We implemented a retrospectively triggered 4D flow CMR acquisition with pseudo-spiral Cartesian k-space filling, which results in incoherent undersampling of k-t space. Additionally, this strategy leads to small jumps in k-space thereby minimizing eddy current related artifacts. The pseudo-spirals were rotated in a tiny golden-angle fashion, which provides optimal incoherence and a variable density sampling pattern with a fully sampled center. We evaluated this 4D flow protocol in a carotid flow phantom with accelerations of R = 2-20, as well as in carotids of 7 healthy subjects (27 ± 2 years, 4 male) for R = 10-30. Fully sampled 2D flow CMR served as a flow reference. Arteries were manually segmented and registered to enable voxel-wise comparisons of both velocity and WSS using a Bland-Altman analysis. RESULTS: Magnitude images, velocity images, and pathline reconstructions from phantom and in vivo scans were similar for all accelerations. For the phantom data, mean differences at peak systole for the entire vessel volume in comparison to R = 2 ranged from - 2.3 to - 5.3% (WSS) and - 2.4 to - 2.2% (velocity) for acceleration factors R = 4-20. For the in vivo data, mean differences for the entire vessel volume at peak systole in comparison to R = 10 were - 9.9, - 13.4, and - 16.9% (WSS) and - 8.4, - 10.8, and - 14.0% (velocity), for R = 20, 25, and 30, respectively. Compared to single slice 2D flow CMR acquisitions, peak systolic flow rates of the phantom showed no differences, whereas peak systolic flow rates in the carotid artery in vivo became increasingly underestimated with increasing acceleration. CONCLUSION: Acquisition of 4D flow CMR of the carotid arteries can be highly accelerated by pseudo-spiral k-space sampling and compressed sensing reconstruction, with consistent data quality facilitating velocity pathline reconstructions, as well as quantitative flow rate and WSS estimations. At an acceleration factor of R = 20 the underestimation of peak velocity and peak WSS was acceptable (< 10%) in comparison to an R = 10 accelerated 4D flow CMR reference scan. Peak flow rates were underestimated in comparison with 2D flow CMR and decreased systematically with higher acceleration factors.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Angiografia por Ressonância Magnética , Modelos Cardiovasculares , Imagem de Perfusão , Adulto , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/fisiologia , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Angiografia por Ressonância Magnética/instrumentação , Masculino , Imagem de Perfusão/instrumentação , Imagens de Fantasmas , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Estresse Mecânico
5.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 42(5): 646-650, 2020 Oct.
Artigo em Zh | MEDLINE | ID: mdl-33131520

RESUMO

Objective To assess the diagnostic value of dual energy pulmonary perfusion imaging(DEPI)for pulmonary embolism.Methods The clinical data of 87 patients with suspected pulmonary embolism who had received DEPI between August 2017 and July 2018 in Jiaxing Second Hospital were retrospectively analyzed.With the findings of CT pulmonary angiography(CTPA)as the reference standard and with patients and pulmonary lobes as evaluation units,respectively,a diagnostic test was performed to calculate the diagnostic coincidence rate,sensitivity,specificity,positive predictive value,negative predictive value,Youden index,positive likelihood ratio,negative likelihood ratio,and Kappa coefficient value for the diagnosis of DEPI and CTPA.Results The coincidence rate,sensitivity,specificity,positive predictive value,negative predictive value,Youden index,positive likelihood ratio,and negative likelihood ratio were 85.06%,88.41%,72.22%,92.42%,61.90%,0.61,3.18,and 0.16,respectively,when applying the patients as evaluation units.When the pulmonary lobes were invoked as evaluation units,the above-mentioned indexes were 89.57%,76.80%,96.82%,93.20%,88.02%,0.74,24.15,and 0.24,respectively.The diagnostic results of DEPI and CTPA had a good and excellent consistency,respectively(Kappa value=0.571,0.765).Conclusions DEPI has high accuracy,sensitivity,and specificity in the detection of pulmonary embolism.The combination of DEPI with CTPA can simultaneously obtain the anatomical structure and functional information images,greatly improving the diagnostic accuracy for pulmonary embolism.Thus,it can be used as the preferred examination for patients with clinically suspected pulmonary embolism.


Assuntos
Imagem de Perfusão , Embolia Pulmonar , Tomografia Computadorizada por Raios X , Testes Diagnósticos de Rotina , Humanos , Imagem de Perfusão/instrumentação , Imagem de Perfusão/normas , Embolia Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/normas
6.
Microvasc Res ; 121: 37-45, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30267716

RESUMO

We report the development of a 1300 nm swept-source optical coherence tomography (SS-OCT) system specifically designed to perform OCT imaging and optical microangiography (OMAG) in rat eyes in vivo and its use in evaluating the effects of intraocular pressure (IOP) elevation on ocular circulation. The swept laser is operated in single longitude mode with a 90 nm bandwidth centered at 1300 nm and 200 kHz A-line rate, providing remarkable sensitivity fall-off performance along the imaging depth, a larger field of view of 2.5 × 2.5 mm2 (approximately 35°), and more time-efficient imaging acquisition. The advantage of the SS-OCT/OMAG is highlighted by an increased imaging depth of the entire posterior thickness of optic nerve head (ONH) and its surrounding vascular anatomy, to include, for the first time in vivo, the vasculature at the scleral opening, allowing visualization of the circle of Zinn-Haller and posterior ciliary arteries (PCAs). Furthermore, the capillary-level resolution angiograms achieved at the retinal and choroidal layers over a larger field of view enable a significantly improved quantification of the response of vascular area density (VAD) to elevated IOP. The results indicate that reduction in perfusion of the choroid in response to elevated IOP is delayed compared to that seen in the retina; while choroidal VAD doesn't reach 50% of baseline until ~70 mmHg, the same effect is seen for the retinal VAD at ~60 mmHg. The superior image quality offered by SS-OCT may allow more comprehensive investigation of IOP-related ocular perfusion changes and their pathological roles in glaucomatous optic nerve damage.


Assuntos
Corioide/irrigação sanguínea , Técnicas de Diagnóstico Oftalmológico/instrumentação , Pressão Intraocular , Microcirculação , Hipertensão Ocular/diagnóstico por imagem , Imagem de Perfusão/instrumentação , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/instrumentação , Animais , Velocidade do Fluxo Sanguíneo , Modelos Animais de Doenças , Desenho de Equipamento , Hipertensão Ocular/fisiopatologia , Valor Preditivo dos Testes , Ratos Endogâmicos BN , Fluxo Sanguíneo Regional , Vasos Retinianos/fisiopatologia , Fatores de Tempo
7.
J Vasc Interv Radiol ; 30(3): 380-389.e4, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30819480

RESUMO

PURPOSE: To compare different imaging techniques (volume perfusion CT, cone-beam CT, and dynamic gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced dynamic contrast-enhanced MR imaging with golden-angle radial sparse parallel MR imaging) in evaluation of transarterial chemoembolization of hepatocellular carcinoma (HCC) using radiopaque drug-eluting embolics (DEE). MATERIALS AND METHODS: MR imaging and CT phantom investigation of radiopaque DEE was performed. In the clinical portion of the study, 13 patients (22 HCCs) were prospectively enrolled. All patients underwent cross-sectional imaging before and after transarterial chemoembolization using 100-300 µm radiopaque DEE. Qualitative assessment of images using a Likert scale was performed. RESULTS: In the phantom study, CT-related beam-hardening artifacts were markedly visible at a concentration of 12% (v/v) radiopaque DEE; MR imaging demonstrated no significant detectable signal intensity changes. Imaging obtained before transarterial chemoembolization showed no significant difference regarding tumor depiction. Visualization of tumor feeding arteries was significantly improved with volume perfusion CT (P < .001) and cone-beam CT (P = .002) compared with MR imaging. Radiopaque DEE led to significant decrease in tumor depiction (P = .001) and significant increase of beam-hardening artifacts (P = .012) using volume perfusion CT before versus after transarterial chemoembolization. Greater residual arterial tumor enhancement was detected with MR imaging (10 HCCs) compared with volume perfusion CT (8 HCCs) and cone-beam CT (6 HCCs). CONCLUSIONS: Using radiopaque DEE, the imaging modalities provided comparable early treatment assessment. In HCCs with dense accumulation of radiopaque DEE, treatment assessment using volume perfusion CT or cone-beam CT may be impaired owing to resulting beam-hardening artifacts and contrast stasis. Dynamic contrast-enhanced MR imaging may add value in detection of residual arterial tumor enhancement.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Doxorrubicina/administração & dosagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Álcool de Polivinil/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Antibióticos Antineoplásicos/efeitos adversos , Artefatos , Carcinoma Hepatocelular/patologia , Quimioembolização Terapêutica/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/instrumentação , Meios de Contraste/administração & dosagem , Doxorrubicina/efeitos adversos , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/instrumentação , Masculino , Microesferas , Pessoa de Meia-Idade , Imagem de Perfusão/instrumentação , Imagens de Fantasmas , Álcool de Polivinil/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento
8.
J Cardiovasc Magn Reson ; 21(1): 30, 2019 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-31104632

RESUMO

BACKGROUND: A velocity offset error in phase contrast cardiovascular magnetic resonance (CMR) imaging is a known problem in clinical assessment of flow volumes in vessels around the heart. Earlier studies have shown that this offset error is clinically relevant over different systems, and cannot be removed by protocol optimization. Correction methods using phantom measurements are time consuming, and assume reproducibility of the offsets which is not the case for all systems. An alternative previously published solution is to correct the in-vivo data in post-processing, interpolating the velocity offset from stationary tissue within the field-of-view. This study aims to validate this interpolation-based offset correction in-vivo in a multi-vendor, multi-center setup. METHODS: Data from six 1.5 T CMR systems were evaluated, with two systems from each of the three main vendors. At each system aortic and main pulmonary artery 2D flow studies were acquired during routine clinical or research examinations, with an additional phantom measurement using identical acquisition parameters. To verify the phantom acquisition, a region-of-interest (ROI) at stationary tissue in the thorax wall was placed and compared between in-vivo and phantom measurements. Interpolation-based offset correction was performed on the in-vivo data, after manually excluding regions of spatial wraparound. Correction performance of different spatial orders of interpolation planes was evaluated. RESULTS: A total of 126 flow measurements in 82 subjects were included. At the thorax wall the agreement between in-vivo and phantom was - 0.2 ± 0.6 cm/s. Twenty-eight studies were excluded because of a difference at the thorax wall exceeding 0.6 cm/s from the phantom scan, leaving 98. Before correction, the offset at the vessel as assessed in the phantom was - 0.4 ± 1.5 cm/s, which resulted in a - 5 ± 16% error in cardiac output. The optimal order of the interpolation correction plane was 1st order, except for one system at which a 2nd order plane was required. Application of the interpolation-based correction revealed a remaining offset velocity of 0.1 ± 0.5 cm/s and 0 ± 5% error in cardiac output. CONCLUSIONS: This study shows that interpolation-based offset correction reduces the offset with comparable efficacy as phantom measurement phase offset correction, without the time penalty imposed by phantom scans. TRIAL REGISTRATION: The study was registered in The Netherlands National Trial Register (NTR) under TC 4865 . Registered 19 September 2014. Retrospectively registered.


Assuntos
Aorta/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Artéria Pulmonar/diagnóstico por imagem , Adulto , Aorta/fisiopatologia , Velocidade do Fluxo Sanguíneo , Europa (Continente) , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/instrumentação , Imagens de Fantasmas , Valor Preditivo dos Testes , Artéria Pulmonar/fisiopatologia , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Adulto Jovem
9.
Vascular ; 27(3): 242-251, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30419804

RESUMO

OBJECTIVES: Laser speckle flowgraphy is a new method that enables the rapid evaluation of foot blood flow without contact with the skin. We used laser speckle flowgraphy to evaluate foot blood flow in peripheral arterial disease patients before and after surgical revascularization. MATERIALS AND METHODS: A prospective single-center study. Thirty-one patients with 33 limbs that underwent surgical revascularization for peripheral arterial disease were included. Pre- and postoperative foot blood flows were measured on the plantar surface via laser speckle flowgraphy and skin perfusion pressure. The laser speckle flowgraphy device was used to visualize the blood flow distribution of the target skin and processed the pulse wave velocity of synchronized heart beats. The mean blood flow, which was expressed as the area of the pulse wave as the beat strength of skin perfusion on laser speckle flowgraphy converted into a numerical value, was assessed as dynamic changes following surgery. Beat strength of skin perfusion was also investigated in non-peripheral arterial disease controls (23 patients/46 limbs). RESULTS: The suitability of beat strength of skin perfusion in non-peripheral arterial disease controls was achieved; the beat strength of skin perfusion value was significantly higher in every area of interest in non-peripheral arterial disease controls compared to that in peripheral arterial disease limbs at the preoperative stage (105.8 ± 8.2 vs. 26.3 ± 8.2; P < 0.01). Although the pulse wave before surgery was visually flat in peripheral arterial disease patients, the pulse wave was remarkably and immediately improved through surgical revascularization. Beat strength of skin perfusion showed a dynamic change in foot blood flow (26.3 ± 8.2 at preoperation, 98.5 ± 6.7 immediately after surgery, 107.6 ± 5.7 at seven days after surgery, P < 0.01 for each compared to preoperation) that correlated with an improvement in skin perfusion pressure. CONCLUSIONS: Laser speckle flowgraphy is a noninvasive, contact-free modality that is easy to implement, and beat strength of skin perfusion is a useful indicator of foot circulation during the perioperative period. Further analysis with a larger number of cases is necessary to establish appropriate clinical use.


Assuntos
Pé/irrigação sanguínea , Hemodinâmica , Lasers Semicondutores , Imagem de Perfusão/instrumentação , Doença Arterial Periférica/cirurgia , Pele/irrigação sanguínea , Idoso , Índice Tornozelo-Braço , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Imagem de Perfusão/métodos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Análise de Onda de Pulso , Fluxo Sanguíneo Regional , Fatores de Tempo , Resultado do Tratamento
10.
Microvasc Res ; 118: 155-161, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29601875

RESUMO

This study was conducted to evaluate conjunctival blood flow velocities and microvascular network density in patients with dry eye disease (DED). Twenty-five patients with DED and 25 healthy controls were recruited. The microvasculature and microcirculation of the temporal bulbar conjunctiva of the right eyes were assessed using a functional slit-lamp biomicroscope. Vascular variables included blood flow velocity (BFV), blood flow rate (BFR), microvascular network density and vessel diameter. A fractal analysis was performed using the box counting method to measure the fractal dimension (Dbox) representing the vessel density. The bulbar BFV was 0.59 ±â€¯0.09 mm/s in the DED group and 0.47 ±â€¯0.12 in the control group (P < 0.001). BFR was 169.5 ±â€¯1.8 in the DED group compared to the control group (107.2 ±â€¯49.6) (P < 0.001). Dbox was higher in DED patients (1.65 ±â€¯0.04) than controls (1.60 ±â€¯0.07, P < 0.05). Moreover, the vessel diameter was larger in the DED group (21.8 ±â€¯1.8 µm) compared with controls (17.9 ±â€¯2.2 µm, P < 0.001). Dbox was positively related with ocular surface disease index (OSDI) in patients with DED (r = 0.54, P = 0.008). Microvascular alterations were found in the bulbar conjunctiva of DED patients, including increased blood flow velocity, higher vessel density and larger vessel diameter.


Assuntos
Túnica Conjuntiva/irrigação sanguínea , Microcirculação , Microvasos/fisiopatologia , Xeroftalmia/fisiopatologia , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Feminino , Fractais , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Microvasos/patologia , Pessoa de Meia-Idade , Imagem de Perfusão/instrumentação , Imagem de Perfusão/métodos , Fluxo Sanguíneo Regional , Lâmpada de Fenda , Microscopia com Lâmpada de Fenda/instrumentação , Xeroftalmia/diagnóstico , Adulto Jovem
11.
J Vasc Surg ; 64(1): 195-201, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26994959

RESUMO

OBJECTIVE: Lack of a reliable outcome measure often leads to excessive or insufficient interventions for critical limb ischemia (CLI). SPY technology (Novadaq Technologies Inc, Bonita Springs, Fla), widely adapted by plastic and general surgeons, uses laser-assisted fluorescence angiography (LAFA) to assess tissue perfusion. We sought to determine the role of SPY as an alternative, perhaps more reliable outcome measure for vascular interventions. METHODS: All patients undergoing elective or urgent revascularization for claudication and CLI were prospectively recruited from June 2012 to August 2014. LAFA using SPY technology was performed before and after revascularization procedures under a standard Institutional Review Board-approved protocol. Quantitative measures of perfusion at plantar surfaces were analyzed and compared with ankle-brachial index. RESULTS: A total of 93 patients with claudication or CLI underwent LAFA before and after a revascularization procedure in the study period. The mean preoperative ankle-brachial index increased from 0.60 to 0.84 (P < .001) after a revascularization procedure. Plantar perfusion as measured by LAFA also improved significantly after intervention. Ingress, defined as the rate at which fluorescence intensity increases on the plantar surface during LAFA, increased from 7.1 to 12.4 units/s (P < .001). Peak perfusion, defined as the difference between the baseline and the peak of fluorescence intensity, increased from 97.1 and 143.9 units (P < .001). Egress, defined as the rate at which intensity diminishes after reaching peak perfusion, increased from 1.0 to 1.9 units/s (P = .035). Procedure-related digital embolization was also observed in several patients despite lack of an angiographic finding. CONCLUSIONS: This is the largest prospective study evaluating SPY technology in peripheral vascular interventions. Our study shows that SPY is a valuable tool in visualizing real-time procedural outcomes and providing additionally useful information on regional tissue perfusion. Further investigation is warranted to standardize outpatient use and to determine threshold values that predict wound healing.


Assuntos
Angiofluoresceinografia/instrumentação , Corantes Fluorescentes/administração & dosagem , Verde de Indocianina/administração & dosagem , Claudicação Intermitente/diagnóstico , Isquemia/diagnóstico , Lasers , Extremidade Inferior/irrigação sanguínea , Imagem de Perfusão/instrumentação , Imagem de Perfusão/métodos , Doença Arterial Periférica/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Índice Tornozelo-Braço , Velocidade do Fluxo Sanguíneo , Estado Terminal , Embolia/diagnóstico , Embolia/etiologia , Embolia/fisiopatologia , Feminino , Humanos , Injeções Intravenosas , Claudicação Intermitente/fisiopatologia , Claudicação Intermitente/terapia , Isquemia/fisiopatologia , Isquemia/terapia , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/terapia , Valor Preditivo dos Testes , Estudos Prospectivos , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
12.
Clin Orthop Relat Res ; 473(1): 82-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25005480

RESUMO

BACKGROUND: Wound necrosis is a potentially devastating complication of complex knee reconstruction. Laser-assisted indocyanine green angiography (LA-ICGA) is a technology that has been described in the plastic surgery literature to provide an objective assessment of skin perfusion in the operating room. This novel technology uses a plasma protein bound dye (ICG) and a camera unit that is calibrated to view the frequency emitted by the dye. The intention of this technology is to offer real-time visualization of blood flow to skin and soft tissue in a way that might help surgeons make decisions about closure or coverage of a surgical site based on blood flow, potentially avoiding soft tissue reconstruction while preventing skin necrosis or wound breakdown after primary closures, but its efficacy is untested in the setting of complex TKA. QUESTIONS/PURPOSES: The purpose of this study was to evaluate perfusion borders and tension ischemia in a series of complex knee reconstructions to guide optimal wound management. METHODS: Beginning in mid-2011, an LA-ICGA system was used to evaluate soft tissue viability in knee reconstruction procedures that were considered high risk for wound complications. Seven patients undergoing complex primary or revision TKA from 2011 to 2013 were included. These patients were chosen as a convenience sample of knee reconstruction procedures for which we obtained consultation with the plastic surgery service. The perfusion of skin and soft tissue coverage was evaluated intraoperatively for all patients with the LA-ICGA system, and the information was used to guide wound management. Followup was at a mean of 9 months (range, 6-17 months), no patients were lost to followup, and the main study endpoint was uneventful healing of the surgical incision. RESULTS: All seven closures went on to heal without necrosis. One patient, however, was subsequently revised for a deep periprosthetic infection 4 months after their knee reconstruction and underwent flap coverage at the time of that revision. CONCLUSIONS: Implementation of LA-ICGA provides an objective intraoperative assessment of soft tissue perfusion. This technology may help guide the surgeon's decisions about wound closure in real-time to accommodate the perfusion challenges unique to each patient. Specifically, patients with medical risk factors for poor perfusion or wound healing (such as diabetes, peripheral vascular disease, tobacco use, corticosteroid therapy, infection) or anatomical/surgical risk factors (ie, previous surgery about the reconstruction site, trauma wounds, or reconstruction of severe deformity) may benefit from objective intraoperative information regarding perfusion of the wound site. Furthermore, LA-ICGA could be used to prospectively evaluate the physiologic impact of different wound closure techniques. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Joelho/efeitos adversos , Isquemia/diagnóstico , Articulação do Joelho/cirurgia , Monitorização Intraoperatória/métodos , Imagem de Perfusão , Pele/irrigação sanguínea , Idoso , Desenho de Equipamento , Corantes Fluorescentes , Humanos , Verde de Indocianina , Isquemia/etiologia , Isquemia/fisiopatologia , Isquemia/prevenção & controle , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação , Necrose , Imagem de Perfusão/instrumentação , Valor Preditivo dos Testes , Radiografia , Fluxo Sanguíneo Regional , Reoperação , Pele/patologia , Fatores de Tempo , Sobrevivência de Tecidos , Resultado do Tratamento , Técnicas de Fechamento de Ferimentos , Cicatrização
13.
Eur J Anaesthesiol ; 32(6): 392-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25906262

RESUMO

BACKGROUND: Little is known about real-time in-vivo microscopy of pulmonary capillary perfusion because current microscopy requires direct access to lung tissue with surgical intervention such as the thoracic-window technique and open-lung model. OBJECTIVES: To evaluate if probe-based confocal laser scanning endomicroscopy (pCLE) via the trachea allows for real-time in-vivo visualisation of pulmonary capillary density and red blood cell (RBC) velocity in pigs. DESIGN: An interventional animal study. SETTING: European University Hospital. ANIMALS: Nine female domestic pigs (50 to 60 kg) were used. MAIN OUTCOME MEASURES: A pCLE probe was positioned in non-dependent, central and dependent lung zones in nine anaesthetised pigs (Alveoflex, Cellvizio, Maunakea, France). After intravenous administration of fluorescein isothiocyanate dextran as contrast agent repetitive pCLE videos were recorded during pressure-controlled ventilation (PCV) or continuous positive airway pressure for 3 min each. Using fluorescein isothiocyanate-labelled RBC erythrocyte velocities in pulmonary capillaries were quantified. Data are expressed as mean ± SD or median with interquartile range (IQR). RESULTS: Capillary density was greater in dependent and central as compared with non-dependent lung zones [[32 (29 to 34) %] and 32 (30 to 34) % vs. 28 (26 to 28) %, respectively, P < 0.05]. During PCV, RBC velocities were higher in larger lung capillaries [diameter >20 µm, 309 µm s(-1) (209 to 397)] than intermediate [diameter 10.1 to 20 µm, 146 µm s(-1) (118 to 235)] and small [diameter <10 µm, 153 µm s(-1) (117 to 236), P <  .05]. During continuous positive airway pressure of 1.5 kPa, RBC velocities in dependent lung areas decreased to 47 µm s(-1) (30 to 82) compared with 198 µm s(-1) (148 to 290) during PCV (P < 0.05). CONCLUSION: pCLE allows endoscopic real-time in-vivo imaging of pulmonary capillary morphology and perfusion. Alterations in pulmonary capillary blood flow induced by different ventilator regimens can be detected. This minimally invasive approach via the endotracheal route is feasible in an experimental setting and may help to understand changes in regional pulmonary capillary perfusion.


Assuntos
Capilares/fisiologia , Sistemas Computacionais , Pulmão/irrigação sanguínea , Pulmão/fisiologia , Imagem de Perfusão/métodos , Animais , Feminino , Microscopia Confocal/métodos , Imagem de Perfusão/instrumentação , Suínos
14.
Stroke ; 45(5): 1355-62, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24627117

RESUMO

BACKGROUND AND PURPOSE: This study aims to determine whether perfusion computed tomographic (PCT) thresholds for delineating the ischemic core and penumbra are time dependent or time independent in patients presenting with symptoms of acute stroke. METHODS: Two hundred seventeen patients were evaluated in a retrospective, multicenter study. Patients were divided into those with either persistent occlusion or recanalization. All patients received admission PCT and follow-up imaging to determine the final ischemic core, which was then retrospectively matched to the PCT images to identify optimal thresholds for the different PCT parameters. These thresholds were assessed for significant variation over time since symptom onset. RESULTS: In the persistent occlusion group, optimal PCT parameters that did not significantly change with time included absolute mean transit time, relative mean transit time, relative cerebral blood flow, and relative cerebral blood volume when time was restricted to 15 hours after symptom onset. Conversely, the recanalization group showed no significant time variation for any PCT parameter at any time interval. In the persistent occlusion group, the optimal threshold to delineate the total ischemic area was the relative mean transit time at a threshold of 180%. In patients with recanalization, the optimal parameter to predict the ischemic core was relative cerebral blood volume at a threshold of 66%. CONCLUSIONS: Time does not influence the optimal PCT thresholds to delineate the ischemic core and penumbra in the first 15 hours after symptom onset for relative mean transit time and relative cerebral blood volume, the optimal parameters to delineate ischemic core and penumbra.


Assuntos
Isquemia Encefálica/fisiopatologia , Imagem de Perfusão/métodos , Acidente Vascular Cerebral/fisiopatologia , Idoso , Isquemia Encefálica/classificação , Isquemia Encefálica/patologia , Meios de Contraste/administração & dosagem , Bases de Dados Factuais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/instrumentação , Valor Preditivo dos Testes , Estudos Retrospectivos , Acidente Vascular Cerebral/classificação , Acidente Vascular Cerebral/patologia , Fatores de Tempo , Tomografia Computadorizada por Raios X
15.
J Cardiovasc Magn Reson ; 16: 46, 2014 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-24962371

RESUMO

BACKGROUND: Phase contrast (PC) measurements play an important role in several cardiovascular magnetic resonance (CMR) protocols but considerable variation is observed in such measurements. Part of this variation stems from the propagation of thermal noise from the measurement data through the image reconstruction to the region of interest analysis used in flow measurement, which limits the precision. The purpose of this study was to develop a method for direct estimation of the variation caused by thermal noise and to validate this method in phantom and in vivo data. METHODS: The estimation of confidence intervals in flow measurements is complicated by noise correlation among the image pixels and cardiac phases. This correlation is caused by sequence and reconstruction parameters. A method for the calculation of the standard deviation of region of interest measurements was adapted and expanded to accommodate typical clinical PC measurements and the region-of-interest analysis used for such measurements. This included the dependency between cardiac phases that arises due to retrospective cardiac gating used in such studies. The proposed method enables calculation of standard deviations of flow measurements without the need for repeated experiments or repeated reconstructions. The method was compared to repeated trials in phantom measurements and pseudo replica reconstructions of in vivo data. Three different flow protocols (free breathing and breath hold with various accelerations) were compared in terms of the confidence interval ranges caused by thermal noise in the measurement data. RESULTS: Using the proposed method it was possible to accurately predict confidence intervals for flow measurements. The method was in good agreement with repeated measurements in phantom experiments and there was also good agreement with confidence intervals predicted by pseudo replica reconstructions in both phantom and in vivo data. The proposed method was used to demonstrate that the variation in cardiac output caused by thermal noise is on the order of 1% in clinically used free breathing protocols, and on the order of 3-5% in breath-hold protocols with higher parallel imaging factors. CONCLUSIONS: It is possible to calculate confidence intervals for Cartesian PC contrast flow measurements directly without the need for time-consuming pseudo replica reconstructions.


Assuntos
Aorta/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Modelos Cardiovasculares , Imagem de Perfusão/métodos , Artéria Pulmonar/fisiologia , Velocidade do Fluxo Sanguíneo , Suspensão da Respiração , Débito Cardíaco , Intervalos de Confiança , Humanos , Modelos Lineares , Imageamento por Ressonância Magnética/instrumentação , Imagem de Perfusão/instrumentação , Imagens de Fantasmas , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Taxa Respiratória , Razão Sinal-Ruído , Fatores de Tempo
16.
Aesthet Surg J ; 34(5): 741-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24809360

RESUMO

BACKGROUND: Body contouring that involves abdominoplasty and/or liposuction is a common cosmetic surgery procedure. Although single-staged lipoabdominoplasty has gained popularity, safety concerns remain. OBJECTIVES: The authors compared abdominal flap perfusion and overall complication rates for traditional abdominoplasty and limited-undermining lipoabdominoplasty. METHODS: Eighteen abdominoplasty patients were evaluated in a prospective study. All patients were nonsmokers and lacked major comorbidities. The control group (n = 9) underwent traditional abdominoplasty with wide undermining. The study group (n = 9) underwent abdominoplasty with limited undermining as well as liposuction of the abdominal flap. The groups were similar with respect to age and body mass index. Patients received follow-up for an average of 97 days. Fluorescence imaging was utilized for perfusion studies. Results and complications were documented, and statistical significance was ascertained via the Student t test. RESULTS: Neither group had major complications or revisions. Minor complications included an exposed suture, resulting in delayed wound healing, in the control group. A patient in the study group had a small area of fat necrosis and a small seroma, neither of which required further treatment. No significant difference in abdominal flap perfusion was found between the control (57%) and study (50%) groups based on fluorescence levels relative to a designated baseline reference marker. CONCLUSIONS: Results of the study indicate that no significant differences exist between the 2 operations with respect to the rates of abdominal flap perfusion or complications. LEVEL OF EVIDENCE: 3.


Assuntos
Abdominoplastia/métodos , Contorno Corporal/métodos , Lasers , Lipectomia/métodos , Imagem Óptica/instrumentação , Imagem de Perfusão/instrumentação , Retalhos Cirúrgicos , Abdominoplastia/efeitos adversos , Adulto , Idoso , Contorno Corporal/efeitos adversos , Feminino , Corantes Fluorescentes/administração & dosagem , Humanos , Verde de Indocianina/administração & dosagem , Lipectomia/efeitos adversos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Retalhos Cirúrgicos/efeitos adversos , Texas , Resultado do Tratamento
17.
Phys Med Biol ; 69(17)2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39137802

RESUMO

Objective.This study introduces a novel desktop micro-CT scanner designed for dynamic perfusion imaging in mice, aimed at enhancing preclinical imaging capabilities with high resolution and low radiation doses.Approach.The micro-CT system features a custom-built rotating table capable of both circular and helical scans, enabled by a small-bore slip ring for continuous rotation. Images were reconstructed with a temporal resolution of 3.125 s and an isotropic voxel size of 65µm, with potential for higher resolution scanning. The system's static performance was validated using standard quality assurance phantoms. Dynamic performance was assessed with a custom 3D-bioprinted tissue-mimetic phantom simulating single-compartment vascular flow. Flow measurements ranged from 1.51to 9 ml min-1, with perfusion metrics such as time-to-peak, mean transit time, and blood flow index calculated.In vivoexperiments involved mice with different genetic risk factors for Alzheimer's and cardiovascular diseases to showcase the system's capabilities for perfusion imaging.Main Results.The static performance validation confirmed that the system meets standard quality metrics, such as spatial resolution and uniformity. The dynamic evaluation with the 3D-bioprinted phantom demonstrated linearity in hemodynamic flow measurements and effective quantification of perfusion metrics.In vivoexperiments highlighted the system's potential to capture detailed perfusion maps of the brain, lungs, and kidneys. The observed differences in perfusion characteristics between genotypic mice illustrated the system's capability to detect physiological variations, though the small sample size precludes definitive conclusions.Significance.The turn-table micro-CT system represents a significant advancement in preclinical imaging, providing high-resolution, low-dose dynamic imaging for a range of biological and medical research applications. Future work will focus on improving temporal resolution, expanding spectral capabilities, and integrating deep learning techniques for enhanced image reconstruction and analysis.


Assuntos
Desenho de Equipamento , Imagem de Perfusão , Imagens de Fantasmas , Microtomografia por Raio-X , Animais , Camundongos , Microtomografia por Raio-X/instrumentação , Imagem de Perfusão/instrumentação , Imagem de Perfusão/métodos , Processamento de Imagem Assistida por Computador/métodos
18.
PLoS One ; 19(8): e0309204, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39186519

RESUMO

Non-invasive perfusion imaging by Arterial spin labeling (ASL) can be advantageous at Ultra-high field (UHF) MRI, since the image SNR and the T1 relaxation time both increase with the static field. However, ASL implementation, especially at 7T, is not trivial. Especially for ASL, UHF MRI comes with many challenges, mainly due to B1+ inhomogeneities. This study aimed to investigate the effects of different transmit coil configurations on perfusion-weighted imaging at 7T using a flow-sensitive alternating inversion recovery (FAIR) technique with time-resolved frequency offset corrected inversion (TR-FOCI) pulses for labeling and background suppression. We conducted a performance comparison between a parallel transmit (pTx) system equipped with 32 receive (Rx) and 8 transmit (Tx) channels and a standard setup with 32Rx and 2Tx channels. Our findings demonstrate that the pTx system, characterized by a more homogeneous B1 transmit field, resulted in a significantly higher contrast-to-noise ratio, temporal signal-to-noise ratio, and lower coefficient of variance (CoV) than the standard 2Tx setup. Additionally, both setups demonstrated comparable capabilities for functional mapping of the hand region in the motor cortex, achieving reliable results within a short acquisition time of approximately 5 minutes.


Assuntos
Imagem de Perfusão , Razão Sinal-Ruído , Marcadores de Spin , Humanos , Masculino , Imagem de Perfusão/métodos , Imagem de Perfusão/instrumentação , Adulto , Feminino , Imageamento por Ressonância Magnética/métodos , Circulação Cerebrovascular/fisiologia , Processamento de Imagem Assistida por Computador/métodos
19.
Stroke ; 44(9): 2601-3, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23868269

RESUMO

BACKGROUND AND PURPOSE: We assigned a threshold to arterial spin-labeling (ASL) perfusion-weighted images (PWI) from patients with acute ischemic stroke and compared them with dynamic susceptibility contrast perfusion images to examine whether mismatch can be determined. METHODS: Pseudocontinuous ASL was combined with dynamic susceptibility contrast PWI in 23 patients with acute ischemic stroke. Scans were obtained within 24 hours of symptom onset. PWI volumes were defined by ASL cerebral blood flow (<15, <20, and <25 mL/100 g per minute) and dynamic susceptibility contrast-mean transit time (MTT) thresholds (>10 s) that show a strong association with cerebral blood flow <20 mL/100 g per minute in Xenon CT studies. Agreement between the ASL-diffusion-weighted imaging and MTT-diffusion-weighted imaging mismatch and the correlation between penumbra salvage and infarct growth, defined as the difference between the baseline PWI and the baseline diffusion-weighted imaging lesion, respectively, and the final infarct volume were assessed. RESULTS: The lesion volumes defined by MTT>10 s and ASL<20 mL/100 g per minute showed an excellent correlation. There was 100% agreement on the mismatch status between MTT>10 s and ASL<20 mL/100 g per minute. The correlation between infarct growth and penumbra salvage volume was significantly better for PWI lesions defined by ASL<20 mL/100 g per minute and MTT>10 s. CONCLUSIONS: In acute ischemic stroke, PWI lesions based on ASL threshold of <20 mL/100 g per minute can provide a reliable estimate of mismatch in correspondence at MTT threshold of >10 s.


Assuntos
Isquemia Encefálica/diagnóstico , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Marcadores de Spin , Acidente Vascular Cerebral/diagnóstico , Adulto , Encéfalo/irrigação sanguínea , Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/normas , Suscetibilidade a Doenças/diagnóstico , Humanos , Aumento da Imagem , Perfusão/instrumentação , Perfusão/métodos , Perfusão/normas , Imagem de Perfusão/instrumentação , Imagem de Perfusão/normas , Valor Preditivo dos Testes , Estudos Prospectivos
20.
Stroke ; 44(7): 1885-90, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23704106

RESUMO

BACKGROUND AND PURPOSE: To investigate relationships between the degree of early reperfusion achieved on perfusion-weighted imaging and clinical outcomes in the Diffusion and Perfusion Imaging Evaluation for Understanding Stroke Evolution studies. We hypothesized that there would be a strong correlation between the degree of reperfusion achieved and clinical outcomes in target mismatch (TMM) patients. METHODS: The degree of reperfusion was calculated on the basis of the difference in perfusion-weighted imaging volumes (time to maximum of tissue residue function [Tmax]>6 s) between the baseline MRI and the early post-treatment follow-up scan. Patients were grouped into quartiles, on the basis of degree of reperfusion achieved, and the association between the degree of reperfusion and clinical outcomes in TMM and no TMM patients was assessed. Favorable clinical response was determined at day 30 on the basis of the National Institutes of Health Stroke Scale and good functional outcome was defined as a modified Rankin Scale score ≤2 at day 90. RESULTS: This study included 121 patients; 98 of these had TMM. The median degree of reperfusion achieved was not different in TMM patients (60%) versus No TMM patients (64%; P=0.604). The degree of reperfusion was strongly correlated with both favorable clinical response (P<0.001) and good functional outcome (P=0.001) in TMM patients; no correlation was present in no TMM. The frequency of achieving favorable clinical response or good functional outcome was significantly higher in TMM patients in the highest reperfusion quartile versus the lower 3 quartiles (88% versus 41% as odds ratio, 10.3; 95% confidence interval, 2.8-37.5; and 75% versus 34% as odds ratio, 5.9; 95% confidence interval, 2.1-16.7, respectively). A receiver operating characteristic curve analysis identified 90% as the optimal reperfusion threshold for predicting good functional outcomes. CONCLUSION: The degree of reperfusion documented on perfusion-weighted imaging after reperfusion therapies corresponds closely with clinical outcomes in TMM patients. Reperfusion of ≥90% of the perfusion lesion is an appropriate goal for reperfusion therapies to aspire to.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Reperfusão/métodos , Acidente Vascular Cerebral/terapia , Idoso , Idoso de 80 Anos ou mais , Ensaios Clínicos como Assunto , Imagem de Difusão por Ressonância Magnética/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/instrumentação , Índice de Gravidade de Doença , Acidente Vascular Cerebral/classificação , Acidente Vascular Cerebral/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa