Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
BMC Vet Res ; 14(1): 6, 2018 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-29304804

RESUMO

BACKGROUND: There is a general consensus in recognizing that traditional meat inspection is no longer able to address the hazards related to meat consumption. Moreover, it has been shown that invasive procedures, such as palpation and incision, can increase microbial contamination in carcasses. For these reasons, legislations all over the world are changing meat inspection techniques, moving towards visual-only techniques. Hence, there was also the need to test visual-only inspection in pigs in Italy. RESULTS: A protocol for visual-only post-mortem inspection was produced together with a 24-class scheme used to record pathological lesions. A list of guidelines needed for univocal interpretation and classification of lesions was developed. To record lesions at the slaughtering line, a light instrument that is resistant to the slaughter environment was designed and then produced in collaboration with an electro-medical company. Six contracted veterinarians were chosen and trained. They performed visual-only post-mortem inspections on 231.673 heavy pigs in three different slaughterhouses of Northern Italy. Visual-only inspection was compared to traditional inspection on 38.819 pig carcasses. No relevant differences were found between the two systems. CONCLUSIONS: The comparison between traditional and visual-only inspection showed that visual-only inspection can be adopted in pig slaughterhouse. The analysis of the performance of the veterinarians stressed the importance of standardization and continuous education for veterinarians working in this field.


Assuntos
Inspeção de Alimentos/métodos , Carne Vermelha/normas , Suínos , Matadouros , Animais , Inspeção de Alimentos/instrumentação , Guias como Assunto , Humanos , Itália , Controle de Qualidade , Software
2.
Crit Rev Food Sci Nutr ; 57(1): 224-236, 2017 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-25831241

RESUMO

This paper aimed to review synchrotron-based and globar-sourced molecular infrared (micro)spectroscopy contributions to advances in new hulless barley (with structure alteration) research on molecular structure, molecular nutrition, and nutrient delivery in ruminants. It reviewed recent progress in barley varieties, its utilization for animal and human, inherent structure features and chemical make-up, evaluation and research methodology, breeding progress, rumen degradation, and intestinal digestion. The emphasis of this review was focused on the effect of alteration of carbohydrate traits of newly developed hulless barley on molecular structure changes and nutrient delivery and quantification of the relationship between molecular structure features and changes and truly absorbed nutrient supply to ruminants. This review provides an insight into how inherent structure changes on a molecular basis affect nutrient utilization and availability in ruminants.


Assuntos
Carboidratos da Dieta/análise , Digestão , Inspeção de Alimentos/métodos , Hordeum/química , Absorção Intestinal , Plantas Geneticamente Modificadas/química , Sementes/química , Ração Animal/análise , Animais , Carboidratos/análise , Carboidratos/biossíntese , Carboidratos/química , Carboidratos da Dieta/metabolismo , Inspeção de Alimentos/instrumentação , Inspeção de Alimentos/tendências , Alimentos Geneticamente Modificados , Hordeum/genética , Hordeum/crescimento & desenvolvimento , Hordeum/metabolismo , Humanos , Gado , Microtecnologia/instrumentação , Estrutura Molecular , Valor Nutritivo , Melhoramento Vegetal , Plantas Geneticamente Modificadas/genética , Plantas Geneticamente Modificadas/crescimento & desenvolvimento , Aves Domésticas , Ruminantes , Sementes/genética , Sementes/crescimento & desenvolvimento , Sementes/metabolismo , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Síncrotrons
3.
J Sci Food Agric ; 96(9): 3007-16, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26399449

RESUMO

BACKGROUND: Recent studies have reported the potential of near infrared (NIR) spectral analysers for monitoring the ripeness of grape berries as an alternative to wet chemistry methods. This study covers various aspects regarding the calibration and implementation of predictive models of total soluble solids (TSS) in grape berries using laboratory and in-field collected NIR spectra. RESULTS: The performance of the calibration models obtained under laboratory conditions indicated that at least 700 berry samples are required to assure enough prediction accuracy. A statistically significant error reduction (ΔRMSECV = 0.1°Brix) with P < 0.001 was observed when measuring berries without epicuticular wax, which was negligible from a practical point of view. Under field conditions, the prediction errors (RMSEP = 1.68°Brix, and SEP = 1.67°Brix) were close to those obtained with the laboratory dataset (RMSEP = 1.42°Brix, SEP = 1.40°Brix). CONCLUSION: This work clarifies several methodological factors to develop a protocol for in-field assessing TSS in grape berries using an affordable, non-invasive, portable NIR spectral analyser. © 2015 Society of Chemical Industry.


Assuntos
Produtos Agrícolas/química , Inspeção de Alimentos/instrumentação , Qualidade dos Alimentos , Frutas/química , Modelos Estatísticos , Vitis/química , Calibragem , Produção Agrícola/normas , Produtos Agrícolas/crescimento & desenvolvimento , Produtos Agrícolas/metabolismo , Confiabilidade dos Dados , Bases de Dados Factuais , Inspeção de Alimentos/normas , Frutas/crescimento & desenvolvimento , Frutas/metabolismo , Guias como Assunto , Teste de Materiais , Análise de Componente Principal , Controle de Qualidade , Refratometria , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Solubilidade , Espanha , Espectroscopia de Luz Próxima ao Infravermelho , Vitis/crescimento & desenvolvimento , Vitis/metabolismo , Ceras/efeitos adversos , Ceras/química , Ceras/metabolismo , Vinho/análise , Vinho/normas
4.
J Sci Food Agric ; 94(7): 1397-402, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24114845

RESUMO

BACKGROUND: In the framework of a breeding programme, the analysis of hundreds of oregano samples to determine their essential oil content (EOC) is time-consuming and expensive in terms of labour. Therefore developing a new method that is rapid, accurate and less expensive to use would be an asset to breeders. The aim of the present study was to develop a method based on near-inrared (NIR) spectroscopy to determine the EOC of oregano dried powder. Two spectroscopic approaches were compared, the first using a hand-held NIR device and the second a Fourier transform (FT) NIR spectrometer. RESULTS: Hand-held NIR (1000-1800 nm) measurements and partial least squares regression allowed the determination of EOC with R² and SEP values of 0.58 and 0.81 mL per 100 g dry matter (DM) respectively. Measurements with FT-NIR (1000-2500 nm) allowed the determination of EOC with R² and SEP values of 0.91 and 0.68 mL per 100 g DM respectively. RPD, RER and RPIQ values for the model implemented with FT-NIR data were satisfactory for screening application, while those obtained with hand-held NIR data were below the level required to consider the model as enough accurate for screening application. CONCLUSION: The FT-NIR approach allowed the development of an accurate model for EOC prediction. Although the hand-held NIR approach is promising, it needs additional development before it can be used in practice.


Assuntos
Inspeção de Alimentos/métodos , Alimentos em Conserva/análise , Modelos Biológicos , Óleos Voláteis/análise , Origanum/química , Folhas de Planta/química , Calibragem , Eficiência Organizacional , Inspeção de Alimentos/instrumentação , Análise dos Mínimos Quadrados , Óleos Voláteis/metabolismo , Origanum/crescimento & desenvolvimento , Origanum/metabolismo , Folhas de Planta/crescimento & desenvolvimento , Folhas de Planta/metabolismo , Reprodutibilidade dos Testes , Especificidade da Espécie , Espectroscopia de Infravermelho com Transformada de Fourier/instrumentação , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Suíça
5.
J Sci Food Agric ; 94(7): 1259-63, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24288215

RESUMO

Computer vision-based image analysis has been widely used in food industry to monitor food quality. It allows low-cost and non-contact measurements of colour to be performed. In this paper, two computer vision-based image analysis approaches are discussed to extract mean colour or featured colour information from the digital images of foods. These types of information may be of particular importance as colour indicates certain chemical changes or physical properties in foods. As exemplified here, the mean CIE a* value or browning ratio determined by means of computer vision-based image analysis algorithms can be correlated with acrylamide content of potato chips or cookies. Or, porosity index as an important physical property of breadcrumb can be calculated easily. In this respect, computer vision-based image analysis provides a useful tool for automatic inspection of food products in a manufacturing line, and it can be actively involved in the decision-making process where rapid quality/safety evaluation is needed.


Assuntos
Inspeção de Alimentos/instrumentação , Qualidade dos Alimentos , Processamento de Imagem Assistida por Computador/instrumentação , Acrilamida/análise , Algoritmos , Carcinógenos/análise , Fast Foods/análise , Fast Foods/economia , Contaminação de Alimentos/economia , Inspeção de Alimentos/economia , Indústria de Processamento de Alimentos/economia , Indústria de Processamento de Alimentos/métodos , Indústria de Processamento de Alimentos/tendências , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador/economia , Reação de Maillard , Porosidade , Controle de Qualidade
6.
Crit Rev Food Sci Nutr ; 52(11): 1039-58, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22823350

RESUMO

Food safety is a great public concern, and outbreaks of food-borne illnesses can lead to disturbance to the society. Consequently, fast and nondestructive methods are required for sensing the safety situation of produce. As an emerging technology, hyperspectral imaging has been successfully employed in food safety inspection and control. After presenting the fundamentals of hyperspectral imaging, this paper provides a comprehensive review on its application in determination of physical, chemical, and biological contamination on food products. Additionally, other studies, including detecting meat and meat bone in feedstuffs as well as organic residue on food processing equipment, are also reported due to their close relationship with food safety control. With these applications, it can be demonstrated that miscellaneous hyperspectral imaging techniques including near-infrared hyperspectral imaging, fluorescence hyperspectral imaging, and Raman hyperspectral imaging or their combinations are powerful tools for food safety surveillance. Moreover, it is envisaged that hyperspectral imaging can be considered as an alternative technique for conventional methods in realizing inspection automation, leading to the elimination of the occurrence of food safety problems at the utmost.


Assuntos
Manipulação de Alimentos/métodos , Inspeção de Alimentos/instrumentação , Inspeção de Alimentos/métodos , Processamento de Imagem Assistida por Computador/métodos , Carne/análise , Imagem Óptica/métodos , Animais , Qualidade de Produtos para o Consumidor , Contaminação de Alimentos/análise , Microbiologia de Alimentos/métodos , Frutas/química , Controle de Qualidade , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Verduras/química
7.
J Sci Food Agric ; 92(3): 638-44, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21919003

RESUMO

BACKGROUND: In Romania, the Alveograph is the most used device to evaluate the rheological properties of wheat flour dough, but lately the Mixolab device has begun to play an important role in the breadmaking industry. These two instruments are based on different principles but there are some correlations that can be found between the parameters determined by the Mixolab and the rheological properties of wheat dough measured with the Alveograph. RESULTS: Statistical analysis on 80 wheat flour samples using the backward stepwise multiple regression method showed that Mixolab values using the 'Chopin S' protocol (40 samples) and 'Chopin + ' protocol (40 samples) can be used to elaborate predictive models for estimating the value of the rheological properties of wheat dough: baking strength (W), dough tenacity (P) and extensibility (L). The correlation analysis confirmed significant findings (P < 0.05 and P < 0.01) between the parameters of wheat dough studied by the Mixolab and its rheological properties measured with the Alveograph. CONCLUSION: A number of six predictive linear equations were obtained. Linear regression models gave multiple regression coefficients with R²(adjusted) > 0.70 for P, R²(adjusted) > 0.70 for W and R²(adjusted) > 0.38 for L, at a 95% confidence interval.


Assuntos
Pão/análise , Farinha/análise , Qualidade dos Alimentos , Modelos Químicos , Absorção Fisico-Química , Fenômenos Químicos , Culinária , Manipulação de Alimentos , Inspeção de Alimentos/instrumentação , Glutens/análise , Glutens/química , Modelos Lineares , Fenômenos Mecânicos , Estabilidade Proteica , Reprodutibilidade dos Testes , Reologia/instrumentação , Romênia , Água/análise , Água/química
8.
Prikl Biokhim Mikrobiol ; 47(6): 685-93, 2011.
Artigo em Russo | MEDLINE | ID: mdl-22288198

RESUMO

An immunochromatographic method for determination of beta-lactam antibiotic ampicillin has been developed. The method is based on the competitive interaction between antibiotic molecules contained in the sample and protein conjugate of penicillin immobilized on a membrane for binding with specific antibodies labeled with colloidal gold, which occurs during movement of the sample to be tested and reagents along the membrane. The completion of the test system ensures control of exceeding the maximum permissible content of the antibiotic in milk and dairy products (10 ng/ml). The possibility of testing milk, raw milk, and dairy products for 10 minutes at room temperature without sample preparation has been demonstrated.


Assuntos
Ampicilina/análise , Cromatografia de Afinidade/métodos , Inspeção de Alimentos/métodos , Imunoensaio/métodos , Leite/química , Animais , Anticorpos/imunologia , Anticorpos/metabolismo , Ligação Competitiva , Bovinos , Cromatografia de Afinidade/instrumentação , Feminino , Inspeção de Alimentos/instrumentação , Coloide de Ouro/química , Proteínas Imobilizadas/química , Proteínas Imobilizadas/imunologia , Proteínas Imobilizadas/metabolismo , Imunoconjugados/química , Imunoconjugados/imunologia , Imunoconjugados/metabolismo , Membranas Artificiais , Albumina Sérica/química , Albumina Sérica/metabolismo
9.
Poult Sci ; 89(6): 1252-64, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20460672

RESUMO

A line-scan machine vision system and multispectral inspection algorithm was developed and evaluated for differentiation of wholesome and systemically diseased chickens on a high-speed processing line. The inspection system acquires line-scan images of chicken carcasses on a 140 bird/min processing line and is able to automatically detect individual birds entering and exiting the field of view of the camera, locate a specified region of interest for spectral image analysis, and produce a decision output for each bird. The same spectral line-scan imaging system was used for hyperspectral data acquisition-analysis to develop the multispectral detection and differentiation algorithm and for multispectral implementation of the algorithm for real-time on-line inspection on the processing line. Results showed that effective multispectral inspection could be achieved by analysis of a selected region of interest across the breast area from images at the 580- and 620-nm wavebands. Overall system performance was evaluated during two 8-h shifts in which the system inspected over 100,000 chickens, with system results compared with Food Safety and Inspection Service inspector tallies of wholesome and systemically diseased birds for that same time period. During system verification, the system accurately classified wholesome and systemically diseased chickens that were observed by a veterinarian posted beside the system to perform real-time identifications of the same birds. The high accuracy of the results demonstrated that the spectra line-scan imaging system and multispectral detection and differentiation algorithm can be effectively used for on-line high-speed presorting applications for young broiler chickens.


Assuntos
Galinhas , Manipulação de Alimentos/instrumentação , Inspeção de Alimentos/instrumentação , Processamento de Imagem Assistida por Computador , Matadouros , Animais , Manipulação de Alimentos/métodos , Inspeção de Alimentos/métodos , Reprodutibilidade dos Testes
10.
Guang Pu Xue Yu Guang Pu Fen Xi ; 29(6): 1445-9, 2009 Jun.
Artigo em Zh | MEDLINE | ID: mdl-19810505

RESUMO

With the development of ultra-fast laser technology and the further understanding of the mechanism behind the interaction of terahertz radiation and materials, THz radiation is actively developed as a new-style technology for a wide range of applications. Currently THz spectroscopy and imaging techniques show great promise in security detection, medical diagnosis, wireless communication, pharmaceutical and many other areas. Because of the growing importance of food safety issues, the detection technology of food safety is also faced with great opportunities and challenges, while THz spectroscopy and imaging techniques provide a new solution to the problem. Compared to other technologies, THz radiation with higher signal-to-noise ratio and wide dynamic range can simultaneously obtain both frequency-domain and time-domain information of the sample which relates to the information of physical structure and chemical composition of materials. Above all THz radiation features unique advantages in food safety inspection. In the present paper, the brief concept of terahertz radiation was introduced, while the properties and technical methods of THz wave were also discussed. The most recent progress in THz technology used in food safety inspection was summarized. The prospect and restricted factors of this novel technology in food industry were also discussed.


Assuntos
Inspeção de Alimentos/métodos , Imagem Molecular/métodos , Análise Espectral/métodos , Contaminação de Alimentos/análise , Inspeção de Alimentos/instrumentação , Substâncias Macromoleculares/análise , Substâncias Macromoleculares/química , Controle de Qualidade
11.
Meat Sci ; 143: 18-23, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29684840

RESUMO

The objective of this study was to investigate the ability of computer vision system to predict pork intramuscular fat percentage (IMF%). Center-cut loin samples (n = 85) were trimmed of subcutaneous fat and connective tissue. Images were acquired and pixels were segregated to estimate image IMF% and 18 image color features for each image. Subjective IMF% was determined by a trained grader. Ether extract IMF% was calculated using ether extract method. Image color features and image IMF% were used as predictors for stepwise regression and support vector machine models. Results showed that subjective IMF% had a correlation of 0.81 with ether extract IMF% while the image IMF% had a 0.66 correlation with ether extract IMF%. Accuracy rates for regression models were 0.63 for stepwise and 0.75 for support vector machine. Although subjective IMF% has shown to have better prediction, results from computer vision system demonstrates the potential of being used as a tool in predicting pork IMF% in the future.


Assuntos
Gorduras na Dieta/análise , Inspeção de Alimentos/métodos , Qualidade dos Alimentos , Carne/análise , Modelos Biológicos , Músculo Esquelético/química , Algoritmos , Animais , Inteligência Artificial , Comportamento do Consumidor , Análise Discriminante , Inspeção de Alimentos/instrumentação , Preferências Alimentares , Humanos , Aprendizado de Máquina , Pigmentos Biológicos/análise , Análise de Regressão , Reprodutibilidade dos Testes , Estatística como Assunto , Máquina de Vetores de Suporte , Sus scrofa
12.
Meat Sci ; 143: 30-38, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29684842

RESUMO

Industry requires non-destructive real-time methods for quality control of meat in order to improve production efficiency and meet consumer expectations. Near Infrared Hyperspectral Images were used for tenderness evaluation of Nellore beef and the construction of tenderness distribution maps. To investigate whether the selection of the region of interest (ROI) in the image at the exact location where the shear force core was collected improves tenderness prediction and classification models, 50 samples from Longissimus muscle were imaged (1000-2500 nm) and shear force were measured (Warner-Bratzler). The data were analyzed by chemometric techniques (Partial Least Squares together with discriminant analysis - PLS-DA). Classification models using local ROI presented better performance than the ROI models of the whole sample (external validation sensitivity for the tough class = 33% and 70%, respectively), but none could be considered as successful model. However, the more general model had better performance in the tenderness distribution maps, with 72% of predicted images correctly classified.


Assuntos
Inspeção de Alimentos/métodos , Qualidade dos Alimentos , Carne/análise , Modelos Biológicos , Músculos Paraespinais/química , Matadouros , Animais , Animais Endogâmicos , Brasil , Calibragem , Bovinos , Análise Discriminante , Estudos de Viabilidade , Inspeção de Alimentos/instrumentação , Análise dos Mínimos Quadrados , Análise de Componente Principal , Reprodutibilidade dos Testes , Resistência ao Cisalhamento , Espectroscopia de Luz Próxima ao Infravermelho
13.
Meat Sci ; 143: 24-29, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29684841

RESUMO

Measurement of thiobarbituric acid reactive substances (TBARS) is a well-established method for determine lipid oxidation in meat. This assay, however, is time-consuming and generates undesired chemical waste. Dam's milk is the principal source of vitamins and provitamins that delay lipid oxidation of light lamb meat; these compounds are stored in the lamb's muscle tissue. Hence, lamb meat could be used to determine the origin of the dam's diet. The aim of this study is to evaluate Near-infrared reflectance spectroscopy (NIRS) as a tool for determining the lipid peroxidation of light lamb meat and differentiate the meat of light lambs according the diet of their dams during lactation (grazing alfalfa, lucerne, or fed a total mixed ration). NIRS using select wavelengths was able to detect the lipid oxidation of meat (TBARS method). NIRS can detect analytes at concentrations of parts per million. Moreover, the feed diets were discriminated successfully.


Assuntos
Fenômenos Fisiológicos da Nutrição Animal , Peroxidação de Lipídeos , Fenômenos Fisiológicos da Nutrição Materna , Carne/análise , Modelos Biológicos , Músculo Esquelético/crescimento & desenvolvimento , Carneiro Doméstico/crescimento & desenvolvimento , Animais , Análise Discriminante , Feminino , Inspeção de Alimentos/instrumentação , Inspeção de Alimentos/métodos , Armazenamento de Alimentos , Lactação , Masculino , Malondialdeído/análise , Malondialdeído/metabolismo , Músculo Esquelético/metabolismo , Pigmentos Biológicos/análise , Pigmentos Biológicos/metabolismo , Gravidez , Carneiro Doméstico/metabolismo , Espectrofotometria , Espectroscopia de Luz Próxima ao Infravermelho , Substâncias Reativas com Ácido Tiobarbitúrico/análise , Substâncias Reativas com Ácido Tiobarbitúrico/metabolismo
14.
Poult Sci ; 86(11): 2450-60, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17954597

RESUMO

A hyperspectral-multispectral line-scan imaging system was developed for differentiation of wholesome and systemically diseased chickens. In-plant testing was conducted for chickens on a commercial evisceration line moving at a speed of 70 birds per minute. Hyperspectral image data was acquired for a calibration data set of 543 wholesome and 64 systemically diseased birds and for a testing data set of 381 wholesome and 100 systemically diseased birds. The calibration data set was used to develop the parameters of the imaging system for conducting multispectral inspection based on fuzzy logic detection algorithms using selected key wavelengths. Using a threshold of 0.4 for fuzzy output decision values, multispectral classification was able to achieve 90.6% accuracy for wholesome birds and 93.8% accuracy for systemically diseased birds in the calibration data set and 97.6% accuracy for wholesome birds and 96.0% accuracy for systemically diseased birds in the testing data set. By adjusting the classification threshold, 100% accuracy was achieved for systemically diseased birds with a decrease in accuracy for wholesome birds to 88.7%. This adjustment shows that the system can be feasibly adapted as needed for implementation for specific purposes, such as paw harvesting operations or prescreening for food safety inspection. This line-scan imaging system is ideal for directly implementing multispectral classification methods developed from hyperspectral image analysis.


Assuntos
Inspeção de Alimentos/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Matadouros , Animais , Automação , Galinhas , Inspeção de Alimentos/métodos , Processamento de Imagem Assistida por Computador/métodos , Fatores de Tempo
15.
Meat Sci ; 128: 8-14, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28160663

RESUMO

Online ultrasound measurements were taken using pulse-echo mode in loins (Longissimus dorsi) and hams at different salting times (up to 30days). From the time-domain ultrasonic wave, the time of flight (TOF) was computed as well as its variation between two signals (ΔTOF). A progressive decrease in TOF during dry salting was found, which was linked to the salt gain, water loss and the reduction in sample thickness. Predictive models based on the ultrasonic parameters (ΔTOF and initial time of flight, TOF0) correctly classified 85% of the loins and 90% of the hams into 3 groups of salt content (low/medium/high). The results obtained confirm that the use of the ultrasonic pulse-echo technique is of great potential in the non-destructive monitoring of dry salting in pork loins and hams, as well as in the prediction of the salt gain for classification purposes.


Assuntos
Inspeção de Alimentos/métodos , Qualidade dos Alimentos , Alimentos em Conserva/análise , Carne/análise , Modelos Biológicos , Ultrassom , Animais , Animais Endogâmicos , Gorduras na Dieta/análise , Estudos de Viabilidade , Inspeção de Alimentos/instrumentação , Conservantes de Alimentos/análise , Aprendizado de Máquina , Carne/economia , Controle de Qualidade , Cloreto de Sódio na Dieta/análise , Espanha , Fatores de Tempo , Água/análise
16.
Lab Chip ; 16(16): 3097-104, 2016 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-27302553

RESUMO

Aflatoxin B1 (AFB1), as the secondary metabolite of molds, is the most predominant and toxic mycotoxin that seriously threatens the health of humans and animals. In this work, an AFB1-responsive hydrogel was synthesized for highly sensitive and portable detection of AFB1. The AFB1-responsive hydrogel was prepared using an AFB1 aptamer and its two short complementary DNA strands as cross-linkers. For visual detection of AFB1, the hydrogel is preloaded with gold nanoparticles (AuNPs). Upon introduction of AFB1, the AFB1 aptamer binds with AFB1, leading to the disruption of the hydrogel and release of the AuNPs with a distinct color change of the supernatant from colorless to red. In order to lower the detection limit and extend the method to quantitative analysis, a distance-readout volumetric bar chart chip (V-chip) was combined with an AFB1-responsive hydrogel preloaded with platinum nanoparticles (PtNPs). In the presence of AFB1, the hydrogel collapses and releases PtNPs which can catalyze the decomposition of H2O2 to generate O2. The increasing gas pressure moves a red ink bar in the V-chip and provides a quantitative relationship between the distance and the concentration of AFB1. The method was applied for detection of AFB1 in beer, with a detection limit of 1.77 nM (0.55 ppb) where an immunoaffinity column (IAC) of AFB1 was used to cleanup and pre-concentrate the sample, which satisfies the testing requirement of 2.0 ppb set by the European Union. The combination of an AFB1-responsive hydrogel with a distance-based readout V-chip offers a user-friendly POCT device, which has great potential for rapid, portable, selective, and quantitative detection of AFB1 in real samples to ensure food safety and avoid subsequent economic losses.


Assuntos
Aflatoxina B1/análise , Carcinógenos Ambientais/análise , Hidrogéis/química , Dispositivos Lab-On-A-Chip , Modelos Químicos , Aptâmeros de Nucleotídeos/química , DNA Complementar/química , Estudos de Viabilidade , Inspeção de Alimentos/instrumentação , Ouro/química , Ácidos Nucleicos Imobilizados/química , Limite de Detecção , Nanopartículas Metálicas/química , Platina/química
17.
Lab Chip ; 16(17): 3251-9, 2016 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-27412355

RESUMO

Here, we introduce a simple and fast method for bonding a poly(dimethylsiloxane) (PDMS) silicone elastomer to different plastics. In this technique, surface modification and subsequent bonding processes are performed at room temperature. Furthermore, only one chemical is needed, and no surface oxidation step is necessary prior to bonding. This bonding method is particularly suitable for encapsulating biomolecules that are sensitive to external stimuli, such as heat or plasma treatment, and for embedding fracturable materials prior to the bonding step. Microchannel-fabricated PDMS was first oxidized by plasma treatment and reacted with aminosilane by forming strong siloxane bonds (Si-O-Si) at room temperature. Without the surface oxidation of the amine-terminated PDMS and plastic, the two heterogeneous substrates were brought into intimate physical contact and left at room temperature. Subsequently, aminolysis occurred, leading to the generation of a permanent seal via the formation of robust urethane bonds after only 5 min of assembling. Using this method, large-area (10 × 10 cm) bonding was successfully realized. The surface was characterized by contact angle measurements and X-ray photoelectron spectroscopy (XPS) analyses, and the bonding strength was analyzed by performing peel, delamination, leak, and burst tests. The bond strength of the PDMS-polycarbonate (PC) assembly was approximately 409 ± 6.6 kPa, and the assembly withstood the injection of a tremendous amount of liquid with the per-minute injection volume exceeding 2000 times its total internal volume. The thermal stability of the bonded microdevice was confirmed by performing a chamber-type multiplex polymerase chain reaction (PCR) of two major foodborne pathogens - Escherichia coli O157:H7 and Salmonella typhimurium - and assessing the possibility for on-site direct detection of PCR amplicons. This bonding method demonstrated high potential for the stable construction of closed microfluidic systems socketed with biomolecule-immobilized surfaces such as DNA, antibody, enzyme, peptide, and protein microarrays.


Assuntos
Técnicas de Tipagem Bacteriana/instrumentação , Materiais Biomiméticos/química , Dimetilpolisiloxanos/química , Inspeção de Alimentos/instrumentação , Microquímica/instrumentação , Tipagem Molecular/instrumentação , Plásticos/química , Escherichia coli O157/classificação , Escherichia coli O157/isolamento & purificação , Estudos de Viabilidade , Humanos , Teste de Materiais , Oxirredução , Cimento de Policarboxilato/química , Resinas Sintéticas/química , Salmonella typhimurium/classificação , Salmonella typhimurium/isolamento & purificação , Propriedades de Superfície , Temperatura
18.
Meat Sci ; 111: 92-100, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26348414

RESUMO

While recent studies state an important role of human sensory methods for daily routine control of so-called boar taint, the evaluation of different heating methods is still incomplete. This study investigated three common heating methods (microwave (MW), hot-water (HW), hot-iron (HI)) for boar fat evaluation. The comparison was carried out on 72 samples with a 10-person sensory panel. The heating method significantly affected the probability of a deviant rating. Compared to an assumed 'gold standard' (chemical analysis), the performance was best for HI when both sensitivity and specificity were considered. The results show the superiority of the panel result compared to individual assessors. However, the consistency of the individual sensory ratings was not significantly different between MW, HW, and HI. The three protocols showed only fair to moderate agreement. Concluding from the present results, the hot-iron method appears to be advantageous for boar taint evaluation as compared to microwave and hot-water.


Assuntos
Gorduras na Dieta/análise , Contaminação de Alimentos , Inspeção de Alimentos/métodos , Qualidade dos Alimentos , Carne/análise , Feromônios/análise , Sus scrofa/fisiologia , Androstenos/análise , Animais , Manipulação de Alimentos/instrumentação , Manipulação de Alimentos/métodos , Inspeção de Alimentos/instrumentação , Alemanha , Temperatura Alta , Humanos , Modelos Logísticos , Masculino , Micro-Ondas , Odorantes , Controle de Qualidade , Reprodutibilidade dos Testes , Sensação , Limiar Sensorial , Escatol/análise
19.
Meat Sci ; 106: 1-5, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25839997

RESUMO

Microbiological contamination in dry-cured ham can occur in the early stages of the process, a large number of microorganisms involved in spoilage can produce alterations in the product. These include non-common odours, which are detected at the end of the process by a procedure called "cala", consisting of a sharp instrument punctured in every ham; this is smelled by an expert taster, who classifies hams as good and altered hams. An electronic device would be suitable for this process given the large amount of hams. The present research aims to develop objective equipment based on the potentiometry technique that identifies altered hams. A probe was developed, containing silver, nickel and copper electrodes, and was employed to classify altered and unaltered hams prior to classification by a tester. The results shown lower Ag and higher Cu potential values for altered hams. The differences in potentiometric response reveal a classification model, although further studies are required to obtain a reliable classification model.


Assuntos
Inspeção de Alimentos/instrumentação , Qualidade dos Alimentos , Alimentos em Conserva/análise , Carne/análise , Animais , Fenômenos Químicos , Alimentos em Conserva/microbiologia , Bactérias Aeróbias Gram-Negativas/crescimento & desenvolvimento , Bactérias Aeróbias Gram-Negativas/isolamento & purificação , Carne/microbiologia , Viabilidade Microbiana , Micrococcaceae/crescimento & desenvolvimento , Micrococcaceae/isolamento & purificação , Potenciometria/instrumentação , Análise de Componente Principal , Espanha , Sus scrofa , Coxa da Perna
20.
Meat Sci ; 106: 61-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25885797

RESUMO

Herein, we developed a novel integrated device to perform phase separation based on ultrasound-assisted, salt-induced, liquid-liquid microextraction for determination of five fluoroquinones in meats by HPLC analysis. The novel integrated device consisted of three simple HDPE (high density polyethylene) parts that were used to separate the solvent from the aqueous solution prior to retrieving the extractant. The extraction parameters were optimized using the response surface method based on central composite design: 589µL of acetone solvent, pH2.1, 4.1min extraction time and 3.5g of Na2SO4. The limits of detection were 0.056-0.64 µgkg(-1) and recoveries were 87.2-110.6% for the five fluoroquinones in muscle tissue from fish, chicken, pork and beef. This method is easily constructed from inexpensive materials, extraction efficiency is high, and the approach is compatible with HPLC analysis. Thus, it has excellent prospects for sample pre-treatment and analysis of fluoroquinones in meat samples.


Assuntos
Antibacterianos/análise , Resíduos de Drogas/análise , Fluoroquinolonas/análise , Contaminação de Alimentos , Inspeção de Alimentos/métodos , Carne/análise , Alimentos Marinhos/análise , Acetona/química , Animais , Antibacterianos/química , Bovinos , Galinhas , China , Resíduos de Drogas/química , Estudos de Viabilidade , Peixes , Fluoroquinolonas/química , Inspeção de Alimentos/instrumentação , Indicadores e Reagentes/química , Limite de Detecção , Microextração em Fase Líquida/instrumentação , Solubilidade , Solventes/química , Sulfitos/química , Sus scrofa , Ultrassom
SELEÇÃO DE REFERÊNCIAS