RESUMO
Developing long bones alter their shape while maintaining uniform cortical thickness via coordinated activity of bone-forming osteoblasts and bone-resorbing osteoclasts at periosteal and endosteal surfaces, a process we designate trans-pairing. Two types of trans-pairing shift cortical bone in opposite orientations: peri-forming trans-pairing (peri-t-p) increases bone marrow space and endo-forming trans-pairing (endo-t-p) decreases it, via paired activity of bone resorption and formation across the cortex. Here, we focused on endo-t-p in growing bones. Analysis of endo-t-p activity in the cortex of mouse fibulae revealed osteoclasts under the periosteum compressed by muscles, and expression of RANKL in periosteal cells of the cambium layer. Furthermore, mature osteoblasts were localized on the endosteum, while preosteoblasts were at the periosteum and within cortical canals. X-ray tomographic microscopy revealed the presence of cortical canals more closely associated with endo- than with peri-t-p. Sciatic nerve transection followed by muscle atrophy and unloading induced circumferential endo-t-p with concomitant spread of cortical canals. Such canals likely supply the endosteum with preosteoblasts from the periosteum under endo-t-p, allowing bone shape to change in response to mechanical stress or nerve injury.
Assuntos
Osteoblastos , Osteoclastos , Periósteo , Animais , Osteoblastos/metabolismo , Osteoblastos/citologia , Periósteo/citologia , Periósteo/metabolismo , Osteoclastos/metabolismo , Osteoclastos/citologia , Camundongos , Desenvolvimento Ósseo , Osteogênese/fisiologia , Reabsorção Óssea/patologia , Osso Cortical , Ligante RANK/metabolismo , Camundongos Endogâmicos C57BLRESUMO
BACKGROUND AND OBJECTIVES: Curettage is the removal of a tumor from the bone while preserving the surrounding healthy cortical bone, and is associated with higher rates of local recurrence. To lower these rates, curettage should be combined with local adjuvants, although their use is associated with damage to nearby healthy bone. OBJECTIVE: The purpose of this analysis is to determine the effect of local adjuvants on cortical porcine bone by using micro-computed tomography (micro-CT) along with histological and mechanical examination. METHODS: Local adjuvants were applied to porcine specimens under defined conditions. To assess changes in bone mineral density (BMD), a micro-CT scan was used. The pixel gray values of the volume of interest (VOI) were evaluated per specimen and converted to BMD values. The Vickers hardness test was employed to assess bone hardness (HV). The depth of necrosis was measured histologically using hematoxylin and eosin-stained tissue sections. RESULTS: A noticeable change in BMD was observed on the argon beam coagulation (ABC) sample. Comparable hardness values were measured on samples following electrocautery and ABC, and lowering of bone hardness was obtained in the case of liquid nitrogen. Extensive induced depth of necrosis was registered in the specimen treated with liquid nitrogen. CONCLUSION: This study determined the effect of local adjuvants on cortical bone by using micro-CT along with histological and mechanical examination. Phenolization and liquid nitrogen application caused a decrease in bone hardness. The bone density was affected in the range of single-digit percentage values. Liquid nitrogen induced extensive depth of necrosis with a wide variance of values.
Assuntos
Densidade Óssea , Neoplasias Ósseas , Osso Cortical , Curetagem , Microtomografia por Raio-X , Animais , Suínos , Neoplasias Ósseas/cirurgia , Neoplasias Ósseas/patologia , Curetagem/métodos , Osso Cortical/patologia , Osso Cortical/diagnóstico por imagem , Osso Cortical/cirurgia , Osso Cortical/efeitos dos fármacos , Densidade Óssea/efeitos dos fármacosRESUMO
Rib fractures remain the most frequent thoracic injury in motor vehicle crashes. Computational human body models (HBMs) can be used to simulate these injuries and design mitigation strategies, but they require adequately detailed geometry to replicate such fractures. Due to a lack of rib cross-sectional shape data availability, most commercial HBMs use highly simplified rib sections extracted from a single individual during original HBM development. This study provides human rib shape data collected from chest CT scans of 240 females and males across the full adult age range. A cortical bone mapping algorithm extracted cross-sectional geometry from scans in terms of local periosteal position with respect to the central rib axis and local cortex thickness. Principal component analysis was used to reduce the dimensionality of these cross-sectional shape data. Linear regression found significant associations between principal component scores and subject demographics (sex, age, height, and weight) at all rib levels, and predicted scores were used to explore the expected rib cross-sectional shapes across a wide range of subject demographics. The resulting detailed rib cross-sectional shapes were quantified in terms of their total cross-sectional area and their cortical bone cross-sectional area. Average-sized female ribs were smaller in total cross-sectional area than average-sized male ribs by between 20% and 36% across the rib cage, with the greatest differences seen in the central portions of rib 6. This trend persisted although to smaller differences of 14%-29% when comparing females and males of equal intermediate weight and stature. Cortical bone cross-sectional areas were up to 18% smaller in females than males of equivalent height and weight but also reached parity in certain regions of the rib cage. Increased age from 25 to 80 years was associated with reductions in cortical bone cross-sectional area (up to 37% in females and 26% in males at mid-rib levels). Total cross-sectional area was also seen to reduce with age in females but to a lesser degree (of up to 17% in mid-rib regions). Similar regions saw marginal increases in total cross-sectional area for male ribs, indicating age affects rib cortex thickness moreso than overall rib cross-sectional size. Increased subject height was associated with increased rib total and cortical bone cross-sectional areas by approximately 25% and 15% increases, respectively, in mid-rib sections for a given 30 cm increase in height, although the magnitudes of these associations varied by sex and rib location. Increased weight was associated with approximately equal changes in both cortical bone and total cross-sectional areas in males. These effects were most prominent (around 25% increases for an addition of 50 kg) toward lower ribs in the rib cage and had only modest effects (less than 12% change) in ribs 2-4. Females saw greater increases with weight in total rib area compared to cortical bone area, of up to 21% at the eighth rib level. Results from this study show the expected shapes of rib cross-sections across the adult rib cage and across a broad range of demographics. This detailed geometry can be used to produce accurate rib models representing widely varying populations.
Assuntos
Costelas , Tórax , Adulto , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Costelas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Modelos Lineares , Osso CorticalRESUMO
The aim of the current study was to investigate the feasibility of three-dimensional ultrashort echo time quantitative susceptibility mapping (3D UTE-QSM) for the assessment of gadolinium (Gd) deposition in cortical bone. To this end, 40 tibial bovine cortical bone specimens were divided into five groups then soaked in phosphate-buffered saline (PBS) solutions with five different Gd concentrations of 0, 0.4, 0.8, 1.2, and 1.6 mmol/L for 48 h. Additionally, eight rabbits were randomly allocated into three groups, consisting of a normal-dose macrocyclic gadolinium-based contrast agent (GBCA) group (n = 3), a high-dose macrocyclic GBCA group (n = 3), and a control group (n = 2). All bovine and rabbit tibial bone samples underwent magnetic resonance imaging (MRI) on a 3-T clinical MR system. A 3D UTE-Cones sequence was utilized to acquire images with five different echo times (i.e., 0.032, 0.2, 0.4, 0.8, and 1.2 ms). The UTE images were subsequently processed with the morphology-enabled dipole inversion algorithm to yield a susceptibility map. The average susceptibility was calculated in three regions of interest in the middle of each specimen, and the Pearson's correlation between the estimated susceptibility and Gd concentration was calculated. The bone samples soaked in PBS with higher Gd concentrations exhibited elevated susceptibility values. A mean susceptibility value of -2.47 ± 0.23 ppm was observed for bovine bone soaked in regular PBS, while the mean QSM value increased to -1.75 ± 0.24 ppm for bone soaked in PBS with the highest Gd concentration of 1.6 mmol/L. A strong positive correlation was observed between Gd concentrations and QSM values. The mean susceptibility values of rabbit tibial specimens in the control group, normal-dose GBCA group, and high-dose GBCA group were -4.11 ± 1.52, -3.85 ± 1.33, and -3.39 ± 1.35 ppm, respectively. In conclusion, a significant linear correlation between Gd in cortical bone and QSM values was observed. The preliminary results suggest that 3D UTE-QSM may provide sensitive noninvasive assessment of Gd deposition in cortical bone.
Assuntos
Gadolínio , Imageamento Tridimensional , Animais , Bovinos , Coelhos , Osso e Ossos/diagnóstico por imagem , Meios de Contraste , Osso Cortical/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodosRESUMO
The primary function of the tetrapod jaw is to transmit jaw muscle forces to bite points. The routes of force transfer in the jaw have never been studied but can be quantified using load paths - the shortest, stiffest routes from regions of force application to support constraints. Here, we use load path analysis to map force transfer from muscle attachments to bite point and jaw joint, and to evaluate how different configurations of trabecular and cortical bone affect load paths. We created three models of the mandible of the Virginia opossum, Didelphis virginiana, each with a cortical bone shell, but with different material properties for the internal spaces: (1) a cortical-trabecular model, in which the interior space is modeled with bulk properties of trabecular bone; (2) a cortical-hollow model, in which trabeculae and mandibular canal are modeled as hollow; and (3) a solid-cortical model, in which the interior is modeled as cortical bone. The models were compared with published in vivo bite force and bone strain data, and the load paths calculated for each model. The trabecular model, which is preferred because it most closely approximates the actual morphology, was best validated by in vivo data. In all three models, the load path was confined to cortical bone, although its route within the cortex varied depending on the material properties of the inner model. Our analysis shows that most of the force is transferred through the cortical, rather than trabecular bone, and highlights the potential of load path analysis for understanding form-function relationships in the skeleton.
Assuntos
Força de Mordida , Mandíbula , Modelos Biológicos , Animais , Fenômenos Biomecânicos , Mandíbula/fisiologia , Mandíbula/anatomia & histologia , Didelphis/fisiologia , Didelphis/anatomia & histologia , Arcada Osseodentária/fisiologia , Arcada Osseodentária/anatomia & histologia , Osso Cortical/fisiologia , Osso Cortical/anatomia & histologia , Osso Esponjoso/fisiologia , Osso Esponjoso/anatomia & histologiaRESUMO
INTRODUCTION: Trabecular bone score (TBS) estimates bone microstructure, which is directly measured by high-resolution peripheral quantitative computed tomography (HRpQCT). We evaluated the correlation between these methods and TBS influence on fracture risk assessed by FRAX. MATERIALS AND METHODS: We evaluated 129 individuals (82 women, 43 postmenopausal) 20 to 82.3 years without prevalent clinical or non-clinical morphometric vertebral fractures, using DXA (spine and hip), HR-pQCT at distal radius (R) and tibia (T) and TBS which classifies bone microarchitecture as normal (TBS ≥ 1.350), partially degraded (1.200 < TBS < 1.350), or degraded (TBS ≤ 1.200). RESULTS: Spine and hip BMD and HR-pQCT parameters at cortical bone: area (T), density (R,T) thickness (T) and trabecular bone: density (R,T), number (T) and thickness (R) were significantly better in the 78 individuals with normal TBS (group 1) versus the 51 classified as partially degraded (n = 42) or degraded microarchitecture (n = 9) altogether (group 2). TBS values correlated with age (r = - 0.55), positively with spine and hip BMD and all cortical and trabecular bone density and microstructure parameters evaluated, p < 0.05 all tests. Binary logistic regression defined age (p = 0.008) and cortical thickness (p = 0.018) as main influences on TBS, while ANCOVA demonstrated that HR-pQCT data corrected for age were not different between TBS groups 1 and 2. TBS adjustment increased FRAX risk for major osteoporotic fractures and hip fractures. CONCLUSION: We describe significant association between TBS and both trabecular and cortical bone parameters measured by HR-pQCT, consistent with TBS influence on fracture risk estimation by FRAX, including hip fractures, where cortical bone predominates.
Assuntos
Densidade Óssea , Osso Esponjoso , Osso Cortical , Tomografia Computadorizada por Raios X , Humanos , Feminino , Idoso , Pessoa de Meia-Idade , Osso Cortical/diagnóstico por imagem , Osso Esponjoso/diagnóstico por imagem , Masculino , Idoso de 80 Anos ou mais , Adulto , Absorciometria de Fóton , Adulto JovemRESUMO
Finite element analysis (FEA) has been used to analyze the behavior of dental materials, mainly in implantology. However, FEA is a mechanical analysis and few studies have tried to simulate the biological characteristics of the healing process of loaded implants. This study used the rule of mixtures to simulate the biological healing process of immediate implants in an alveolus socket and bone-implant junction interface through FEA. Three-dimensional geometric models of the structures were obtained, and material properties were derived from the literature. The rule of mixtures was used to simulate the healing periods-immediate and early loading, in which the concentration of each cell type, based on in vivo studies, influenced the final elastic moduli. A 100 N occlusal load was simulated in axial and oblique directions. The models were evaluated for maximum and minimum principal strains, and the bone overload was assessed through Frost's mechanostat. There was a higher strain concentration in the healing regions and cortical bone tissue near the cervical portion. The bone overload was higher in the immediate load condition. The method used in this study may help to simulate the biological healing process and could be useful to relate FEA results to clinical practice.
Assuntos
Implantes Dentários , Módulo de Elasticidade , Análise de Elementos Finitos , Carga Imediata em Implante Dentário , Alvéolo Dental , Cicatrização , Humanos , Alvéolo Dental/fisiologia , Cicatrização/fisiologia , Fenômenos Biomecânicos , Simulação por Computador , Interface Osso-Implante/fisiologia , Estresse Mecânico , Processo Alveolar/fisiologia , Modelos Biológicos , Osseointegração/fisiologia , Força de Mordida , Análise do Estresse Dentário/métodos , Osteoblastos/fisiologia , Osso Cortical/fisiologia , Imageamento Tridimensional/métodosRESUMO
BACKGROUND: This study aimed to evaluate the mandibular bone structure of patients using oral anticoagulants (OACs) vitamin K antagonist drugs (warfarin) and other OACs including direct oral anticoagulants [(DOACs) apixaban, rivaroxaban, dabigatran, edoxaban]. Analyses were based upon the fractal dimension (FD), the panoramic mandibular index (PMI) and the Klemetti index (KI), which is also known as the mandibular cortical index (MCI). METHODOLOGY: Ninety participants were divided into three groups: group 1: 30 systemically healthy individuals who had not used any anticoagulants before, group 2: 30 individuals using warfarin, and group 3: 30 individuals using DOACs. FD was used to analyze trabecular bone architecture in the condyle, angle, and two sites in the alveolar bone. PMI was used to evaluate the quantity of cortical bone and KI was used to evaluate the cortical bone quality. RESULTS: There was no difference between the groups regarding FD analysis and KI; however, a difference was found between groups 1, 2, and 3 in the PMI (P≤ 0.001). The PMI in group 1 was higher than in groups 2 and 3. CONCLUSION: Mandibular radiomorphometric indices can be used on panoramic radiographs to evaluate the quantity of mandibular cortical bone in patients using oral anticoagulants.
Assuntos
Anticoagulantes , Osso Esponjoso , Osso Cortical , Dabigatrana , Mandíbula , Rivaroxabana , Varfarina , Humanos , Mandíbula/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Anticoagulantes/administração & dosagem , Anticoagulantes/farmacologia , Dabigatrana/administração & dosagem , Rivaroxabana/administração & dosagem , Varfarina/administração & dosagem , Osso Esponjoso/diagnóstico por imagem , Osso Esponjoso/efeitos dos fármacos , Osso Cortical/diagnóstico por imagem , Osso Cortical/efeitos dos fármacos , Piridonas/administração & dosagem , Adulto , Pirazóis/administração & dosagem , Tiazóis/administração & dosagem , Idoso , Vitamina K/antagonistas & inibidores , Piridinas/administração & dosagem , Radiografia Panorâmica , Administração Oral , Densidade Óssea/efeitos dos fármacos , Inibidores do Fator Xa/administração & dosagemRESUMO
In orthopedic surgery, precise bone screw insertion is crucial for stabilizing fractures, necessitating a preliminary cortical bone drilling procedure. However, this process can induce temperatures exceeding 70 °C due to the low thermal conductivity of cortical bone, potentially leading to thermal osteonecrosis. Furthermore, significant cutting forces and torque pose risks of tool breakage and bone damage, underlining the need for high precision and optimal processing parameters. Traditionally, drilling relies on the surgeon's experience and often results in imprecise outcomes due to inconsistent feed rates. Therefore, this study proposes the use of a 6-axis robot for controlled drilling, offering precise control over angular velocities and consistent feed rates. Additionally, explore the use of cryogenic liquid nitrogen (LN2) as a novel cooling method compared to conventional saline solutions, examining its efficacy under various cutting conditions. The results demonstrate that LN2 cooling conditions lead to a reduction in thrust and torque under specific processing conditions, and facilitate smoother chip evacuation. Additionally, LN2 significantly lowers the peak temperature around the drilling site, thus minimizing the risk of thermal osteonecrosis. Consequently, the use of a 6-axis robot provides consistent feed rates, and LN2 cooling achieves optimal processing conditions, enabling a more controlled and effective drilling process.
Assuntos
Osso Cortical , Osso Cortical/cirurgia , Animais , Procedimentos Cirúrgicos Robóticos/instrumentação , Nitrogênio/química , Robótica/instrumentação , Temperatura Baixa , Fenômenos Mecânicos , Torque , Procedimentos Ortopédicos/instrumentação , Procedimentos Ortopédicos/métodosRESUMO
PURPOSE: To compare the clinical outcomes and radiographic outcomes of cortical bone trajectory (CBT) and traditional trajectory (TT) pedicle screw fixation in patients treated with single-level transforaminal lumbar interbody fusion (TLIF). METHODS: This trial included a total of 224 patients with lumbar spine disease who required single-level TLIF surgery. Patients were randomly assigned to the CBT and TT groups at a 1:1 ratio. Demographics and clinical and radiographic data were collected to evaluate the efficacy and safety of CBT and TT screw fixation in TLIF. RESULTS: The baseline characteristic data were similar between the CBT and TT groups. Back and leg pain for both the CBT and TT groups improved significantly from baseline to 24 months postoperatively. The CBT group experienced less pain than the TT group at one week postoperatively. The postoperative radiographic results showed that the accuracy of screw placement was significantly increased in the CBT group compared with the TT group (P < 0.05). The CBT group had a significantly lower rate of FJV than the TT group (P < 0.05). In addition, the rate of fusion and the rate of screw loosening were similar between the CBT and TT groups according to screw loosening criteria. CONCLUSION: This prospective, randomized controlled analysis suggests that clinical outcomes and radiographic characteristics, including fusion rates and caudal screw loosening rates, were comparable between CBT and TT screw fixation. Compared with the TT group, the CBT group showed advantages in the accuracy of screw placement and the FJV rate. CLINICAL TRIALS REGISTRATION: This trial has been registered at the US National Institutes of Health Clinical Trials Registry: NCT03105167.
Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Parafusos Pediculares/efeitos adversos , Fusão Vertebral/métodos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Osso Cortical/diagnóstico por imagem , Osso Cortical/cirurgia , Dor/etiologiaRESUMO
BACKGROUND: Supplemental bone grafting is regularly required before dental implant placement in patients with cleft lip and palate (CLP). PURPOSE: The study purpose was to measure and compare implant osseointegration and changes in graft dimensions following lateral incisor onlay cortical bone grafting in CLP and non-CLP patients. STUDY DESIGN, SETTING, SAMPLE: Retrospective cohort study composed of patients who presented to Boston Children's Hospital and underwent autogenous onlay cortical block bone grafting at lateral incisor sites from 2015 through 2023. Patients were excluded if the cone beam computed tomography (CBCT) quality was insufficient for accurate measurements. PREDICTOR VARIABLE: The predictor variable was CLP status coded as CLP or non-CLP. MAIN OUTCOME VARIABLE: The primary outcome variable was successful implant osseointegration confirmed by a torque of 35 N/cm or more after 3 months of implant healing. Secondary outcomes were change in bone width between preoperative and postoperative CBCT scans at lateral incisor sites and the need for additional bone augmentation prior to or during implant placement. COVARIATES: Covariates were age, sex, cleft location, and time from bone graft to postoperative CBCT and implant placement. ANALYSES: Data analyses were performed using t-tests, Fisher's exact tests, Mann-Whitney U tests, and Pearson's correlation. P < .05 was considered statistically significant. RESULTS: A total of 22 subjects (16 with CLP) were evaluated. The mean age at the time of graft was 19.3 ± 2.4 years with 52.6% males. Implants were osseointegrated at 20 of 22 lateral incisor sites (1 CLP failure, 1 non-CLP failure). There was significant change in bone width after grafting for patients with CLP (P < .001). Patients with CLP experienced a 3.32 (± 1.80) mm and 2.99 (± 1.61) mm increase in bone width at 2 different levels. Patients with CLP achieved greater boney changes near the alveolar crest than noncleft patients (P = .008) but the change was not significantly different more apically (P = .86). One subject with CLP required additional grafting during implant placement. CONCLUSION AND RELEVANCE: Cortical block onlay bone grafting is a predictable technique to augment lateral incisor sites in patients with CLP for placement of a dental implant.
Assuntos
Fenda Labial , Fissura Palatina , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Humanos , Masculino , Estudos Retrospectivos , Feminino , Fissura Palatina/cirurgia , Fissura Palatina/diagnóstico por imagem , Fenda Labial/cirurgia , Implantação Dentária Endóssea/métodos , Adolescente , Transplante Ósseo/métodos , Criança , Osseointegração/fisiologia , Incisivo/diagnóstico por imagem , Osso Cortical/transplante , Osso Cortical/diagnóstico por imagem , Resultado do Tratamento , Implantes DentáriosRESUMO
OBJECTIVES: Modified cortical bone trajectory (MCBT) technique was proposed by our team in previous studies, but its biomechanical properties at adjacent segments have not been discussed yet. Therefore, the purpose of this study is to investigate the biomechanical properties of modified cortical bone trajectory (MCBT) technique on adjacent segment degeneration (ASD) in transforaminal intradiscal lumbar disc fusion (TLIF) compare to traditional bone trajectory (TT) technique and cortical bone trajectory (CBT) technique. METHODS: The four human cadaveric lumbar specimens were provided by the anatomy teaching and research department of Xinjiang Medical University and four intact finite element models of the L1-S1 segment were generated. For each of these, three transforaminal lumbar interbody fusion procedures with three different fixation techniques were reconstructed at the L4-L5 segment, as follows: TT-TT (TT at both L4 and L5 segments), CBT-CBT (CBT at both L4 and L5 segments), MCBT-MCBT (MCBT at both L4 and L5 segments). The range of motion and von Mises stress of the intervertebral disc of the L3-L4 and L5-S1 segments were recorded with a 400N compressive load and 7.5 Nm moments in flexion, extension, left-right bending, and left-right rotation. RESULTS: The peak ROM of the L3-L4 segment in the MCBT-MCBT group was reduced by 10.5%, 6.1%, 12.2%, 4.1%, and 1.5% in flexion, extension, left-right bending, and left rotation compared to the TT-TT group and reduced by 1.8%, 5.5%, 10.0%, 12.8%, and 8.8% in flexion, left-right bending, and left-right rotation compared to the CBT-CBT group, respectively. The MCBT-MCBT group has the lowest peak ROM of the L3-L4 segment in flexion, left bending, and right rotation, the lowest peak ROM of the L5-S1 segment in extension and right rotation, and the lowest peak von Mises stress of the intervertebral disc at the L5-S1 segment in right rotation compared to the TT-TT and CBT-CBT group. In addition, the peak von Mises stress at the L3-L4 segment was lowest and more dispersed in all motions, the MCBT-MCBT group exhibited lower peak ROM of the L5-S1 segment in flexion, extension, and right rotation, and showed lower peak von Mises stress of the disc at the L5-S1 segment in flexion, extension, and right rotation compared with the TT-TT group. CONCLUSION: The modified cortical bone trajectory technique may have a beneficial effect on reducing the incidence of ASD in the L4-L5 TLIF model compared to the traditional bone trajectory technique and cortical bone trajectory technique.
Assuntos
Vértebras Lombares , Fusão Vertebral , Humanos , Análise de Elementos Finitos , Vértebras Lombares/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Fenômenos Biomecânicos , Osso Cortical/cirurgia , Amplitude de Movimento ArticularRESUMO
BACKGROUND: Endoscopically assisted screw fixation with lumbar interbody fusion is rarely performed. We succeeded in implanting the cortical bone trajectory (CBT) screws under the guidance of unilateral biportal endoscopy (UBE). METHOD: We attempted endoscopically assisted screw fixation in a patient with degenerative spondylolisthesis. Through a third portal, ipsilateral CBT screws were implanted without complications. CONCLUSIONS: We successfully performed unilateral biportal endoscopic lumbar interbody fusion (ULIF) with CBT and reversed CBT screws. Compared with percutaneous pedicle screw (PPS) placement, this procedure is a minimally invasive, endoscopic alternative that allows precise screw placement.
Assuntos
Parafusos Pediculares , Fusão Vertebral , Espondilolistese , Humanos , Espondilolistese/diagnóstico por imagem , Espondilolistese/cirurgia , Endoscopia , Osso Cortical/diagnóstico por imagem , Osso Cortical/cirurgia , Osso e Ossos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Fusão Vertebral/métodos , Resultado do TratamentoRESUMO
Frequently orthopedic surgeries require mechanical drilling processes especially for inserted biodegradable screws or removing small bone lesions. However mechanical drilling techniques induce large number of forces as well as have substantially lower material removal rates resulting in prolong healing times. This study focuses on analyzing the impact of quasi-continuous laser drilling on the bone's surface as well as optimizing the drilling conditions to achieve high material removal rates. An ex-vivo study was conducted on the cortical region of desiccated bovine bone. The laser-based drilling on the bovine bine specimens was conducted in an argon atmosphere using a number of laser pulses ranging from 100 to 15,000. The morphology of the resulting laser drilled cavities was characterized using Energy dispersive Spectroscopy (EDS) and the width and depth of the drills were measured using a laser based Profilometer. Data from the profilometer was then used to calculate material removal rates. At last, the material removal rates and laser processing parameters were used to develop a statistical model based on Design of Experiments (DOE) approach to predict the optimal laser drilling parameters. The main outcome of the study based on the laser drilled cavities was that as the number of laser pulses increases, the depth and diameter of the cavities progressively increase. However, the material removal rates revealed a decrease in value at a point between 4000 and 6000 laser pulses. Therefore, based on the sequential sum of square method, a polynomial curve to the 6th power was fit to the experimental data. The predicted equation of the curve had a p-value of 0.0010 indicating statistical significance and predicted the maximum material removal rate to be 32.10 mm3/s with 95%CI [28.3,35.9] which was associated with the optimum number of laser pulses of 4820. Whereas the experimental verification of bone drilling with 4820 laser pulses yielded a material removal rate of 33.37 mm3/s. Therefore, this study found that the carbonized layer formed due to laser processing had a decreased carbon content and helped in increasing the material removal rate. Then using the experimental data, a polymetric equation to the sixth power was developed which predicted the optimized material removal rate to occur at 4820 pulses.
Assuntos
Osso Cortical , Terapia a Laser , Animais , Bovinos , Osso Cortical/cirurgia , Osso Cortical/efeitos da radiação , Terapia a Laser/métodos , Terapia a Laser/instrumentação , Espectrometria por Raios X , Procedimentos Ortopédicos/métodos , Procedimentos Ortopédicos/instrumentaçãoRESUMO
Over the past few decades, early osteoporosis detection using ultrasonic bone quality evaluation has gained prominence. Specifically, various studies focused on axial transmission using ultrasonic guided waves and have highlighted this technique's sensitivity to intrinsic properties of long cortical bones. This work aims to demonstrate the potential of low-frequency ultrasonic guided waves to infer the properties of the bone inside which they are propagating. A proprietary ultrasonic transducer, tailored to transmit ultrasonic guided waves under 500 kHz, was used for the data collection. The gathered data underwent two-dimensional fast Fourier transform processing to extract experimental dispersion curves. The proposed inversion scheme compares experimental dispersion curves with simulated dispersion curves calculated through the semi-analytical iso-geometric analysis (SAIGA) method. The numerical model integrates a bone phantom plate coupled with a soft tissue layer on its top surface, mimicking the experimental bone phantom plates. Subsequently, the mechanical properties of the bone phantom plates were estimated by reducing the misfit between the experimental and simulated dispersion curves. This inversion leaned heavily on the dispersive trajectories and amplitudes of ultrasonic guided wave modes. Results indicate a marginal discrepancy under 5% between the mechanical properties ascertained using the SAIGA-based inversion and those measured using bulk wave pulse-echo measurements.
Assuntos
Osso Cortical , Imagens de Fantasmas , Ultrassonografia , Osso Cortical/diagnóstico por imagem , Osso Cortical/fisiologia , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Análise de Fourier , Ondas Ultrassônicas , Humanos , Transdutores , Análise Numérica Assistida por Computador , Simulação por ComputadorRESUMO
OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.
Assuntos
Benzofenonas , Coroas , Dente Suporte , Análise do Estresse Dentário , Análise de Elementos Finitos , Cetonas , Teste de Materiais , Polietilenoglicóis , Polímeros , Titânio , Zircônio , Cetonas/química , Polietilenoglicóis/química , Humanos , Zircônio/química , Titânio/química , Fibra de Carbono/química , Projeto do Implante Dentário-Pivô , Incisivo , Materiais Dentários/química , Implantes Dentários para Um Único Dente , Osso Cortical , Vidro/química , Planejamento de Prótese DentáriaRESUMO
Cortical bone thickness is essential for the mechanical function of bone. Some factors including aging, sex, body size, hormone levels, behavior, and genetics lead to changes in cranial cortical robusticity. Moreover, the skull is one of the hardest and most durable structures in the human body. Schizophrenia is defined as a psychiatric disease characterized by delusions and hallucinations, and these patients have reduced brain volume; however, there is no study including cortical bone structure. For this reason, the aim of this study was to determine whether there is a difference in the skull cortical thickness of patients with schizophrenia and, compare it with healthy subjects. The cranial length, cranial width, anterior cortical thickness, right and left anterior cortical thickness, right and left lateral cortical thickness, right and left posterior lateral thickness, and posterior cortical thickness were measured with axial computed tomography images of 30 patients with schizophrenia and 132 healthy individuals aged between 18 and 69years. A statistically significant difference was found between the two groups in the measurements of right and left posterior lateral thickness, and posterior cortical thickness ( P = 0.006, P = 0.001, and P = 0.047, respectively). The sexes were compared, and it was found that the cranial width, anterior thickness, left anterior thickness, and right and left posterior thickness measurements of patients with schizophrenia showed a statistically significant difference compared with the control group ( P < 0.001, P = 0.003, P = 0.001, P < 0.001 and P < 0.001, respectively). The authors observed that skull cortical thickness may be different in schizophrenia. The results obtained from this study may be beneficial for evaluating these structures for clinical and pathological processes. Furthermore, knowledge about the skull cortical thickness in planning surgical procedures will increase the reliability and effectiveness of the surgical method, and this will minimize the risk of complications.
Assuntos
Esquizofrenia , Crânio , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Esquizofrenia/diagnóstico por imagem , Esquizofrenia/patologia , Adulto , Pessoa de Meia-Idade , Crânio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Idoso , Adulto Jovem , Osso Cortical/diagnóstico por imagem , Osso Cortical/patologia , Estudos de Casos e ControlesRESUMO
Fatigue crack propagation resistance and high-cycle S-N fatigue life of cortical bone allograft tissue are both negatively impacted in a radiation dose-dependent manner from 0 to 25 kGy. The standard radiation sterilization dose of 25-35 kGy has been shown to induce cleavage of collagen molecules into smaller peptides and accumulation of stable crosslinks within the collagen matrix, suggesting that these mechanisms may influence radiation-induced losses in cyclic fracture resistance. The objective of this study was to determine the radiation dose-dependency of collagen chain fragmentation and crosslink accumulation within the dose range of 0-25 kGy. Previously, cortical bone compact tension specimens from two donor femoral pairs were divided into four treatment groups (0 kGy, 10 kGy, 17.5 kGy, and 25 kGy) and underwent cyclic loading fatigue crack propagation testing. Following fatigue testing, collagen was isolated from one compact tension specimen in each treatment group from both donors. Radiation-induced collagen chain fragmentation was assessed using SDS-PAGE (n = 5), and accumulation of pentosidine, pyridinoline, and non-specific advanced glycation end products were assessed using a fluorometric assay (n = 4). Collagen chain fragmentation increased progressively in a dose-dependent manner (p < 0.001). Crosslink accumulation at all radiation dose levels increased relative to the 0 kGy control but did not demonstrate dose-dependency (p < 0.001). Taken together with our previous findings on fatigue crack propagation behavior, these data suggest that while collagen crosslink accumulation may contribute to reduced notched fatigue behavior with irradiation, dose-dependent losses in fatigue crack propagation resistance are mainly influenced by radiation-induced chain fragmentation.
Assuntos
Aloenxertos , Colágeno , Relação Dose-Resposta à Radiação , Raios gama , Esterilização , Humanos , Esterilização/métodos , Colágeno/metabolismo , Osso Cortical/efeitos da radiação , Transplante Ósseo , Produtos Finais de Glicação Avançada/metabolismo , Fêmur/efeitos da radiação , Lisina/metabolismo , Lisina/análogos & derivados , Aminoácidos/análise , Aminoácidos/metabolismo , Arginina/análogos & derivadosRESUMO
BACKGROUND: Cortical thickness and porosity are two main determinants of cortical bone strength. Thus, mapping variations in these parameters across the full width of the distal end of the clavicle may be helpful for better understanding the basis of distal clavicle fractures and for selecting optimal surgical treatment. METHODS: Distal ends of 11 clavicles (6 men, 5 women; age: 81.9 ± 15.1 years) were scanned by micro-computed tomography at 10-µm resolution. We first analyzed cortical thickness and porosity of each 500-µm-wide area across the superior surface of distal clavicle at the level of conoid tubercle in an antero-posterior direction. This level was chosen for detailed evaluation because previous studies have demonstrated its superior microarchitecture relative to the rest of the distal clavicle. Subsequently, we divided the full width of distal clavicle to three subregions (anterior, middle, and posterior) and analyzed cortical porosity, pore diameter, pore separation, and cortical thickness. RESULTS: We found the largest number of low-thickness and high-porosity areas in the anterior subregion. Cortical porosity, pore diameter, pore separation, and cortical thickness varied significantly among the three subregions (p < 0.001 p = 0.016, p = 0.001, p < 0.001, respectively). Cortex of the anterior subregion was more porous than that of the middle subregion (p < 0.001) and more porous and thinner than that of the posterior subregion (p < 0.001, p = 0.030, respectively). Interaction of site and sex revealed higher porosity of the anterior subregion in women (p < 0.001). The anterior subregion had larger pores than the middle subregion (p = 0.019), whereas the middle subregion had greater pore separation compared with the anterior (p = 0.002) and posterior subregions (p = 0.006). In general, compared with men, women had thinner (p < 0.001) and more porous cortex (p = 0.03) with larger cortical pores (p < 0.001). CONCLUSIONS: Due to high cortical porosity and low thickness, the anterior conoid subregion exhibits poor bone microarchitecture, particularly in women, which may be considered in clinical practice. LEVELS OF EVIDENCE: Level IV.
Assuntos
Clavícula , Fraturas Ósseas , Humanos , Clavícula/lesões , Clavícula/cirurgia , Clavícula/diagnóstico por imagem , Feminino , Masculino , Idoso , Fraturas Ósseas/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Idoso de 80 Anos ou mais , Microtomografia por Raio-X , Osso Cortical/diagnóstico por imagem , Osso Cortical/cirurgia , Osso Cortical/anatomia & histologia , Porosidade , Pessoa de Meia-Idade , CadáverRESUMO
AIM: Distal femur fractures (DFF) are rare, but associated with high complication rates and mortality, particularly in patients with osteoporosis. To improve preoperative assessment, we analyzed if cortical bone thickness on CT and AP radiographs is associated with clinical parameters of bone quality. METHODS: Retrospective single-center study of adult patients presenting at a level-one trauma center, with a DFF between 2011 and 2020. Clinical parameters for bone quality, such as age, sex, body mass index (BMI), energy impact level of trauma, and known history of osteoporosis, were assessed. Mean cortical bone thickness (CBTavg) on AP radiograph was determined using a previously published method. Cortical thickness on CT scan was measured at 8 and 14 cm proximal to the articular surface of the lateral condyle. RESULTS: 71 patients (46 females) between 20 and 100 years were included in the study. Cortical thickness determined by CT correlated significantly with CBTavg measurements on AP radiograph (Spearman r = 0.62 to 0.80; p < 0.001). Cortical thickness was inversely correlated with age (Spearman r = - 0.341 to - 0.466; p < 0.001) and significantly associated with trauma impact level and history of osteoporosis (p = < 0.001). The CT-based values showed a stronger correlation with the clinical parameters than those determined by AP X-ray. CONCLUSION: Our results showed that cortical thickness of the distal femur correlates with clinical parameters of bone quality and is therefore an excellent tool for assessing what surgical care should be provided. Interestingly, our findings indicate that cortical thickness on CT is more strongly correlated with clinical data than AP radiograph measurements.