1.
BMC Public Health ; 24(1): 2031, 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39075367

RESUMO

BACKGROUND: The majority of existing industries in Ethiopia discharge untreated effluents into nearby water bodies, streams and open land. The wastewater generated by Gondar malt factory (GMF) was disposed freely and join a natural wetland implemented for the treatment of the wastewater. The objective of the study was to analyze and characterize wastewater from GMF and to evaluate the effectiveness of the wetland for the treatment purpose. METHODS: Different Physicochemical quality indicators (color, turbidity pH, temperature, Total Dissolved solids, Total Suspended solids, total solid, conductivity, alkalinity, hardness, nitrate, phosphate, sulfate, free chlorides, heavy metals-(Cd, Cr, Fe, Mn, and Pb)and Biological Oxygen Demand were measured according to the standard procedures. Data was analyzed using Statistical Package for Social Sciences (SPSS-25). Analysis of Variance (ANOVA) was used to find whether significant differences existed in the different sampling stations for the parameters studied. P value less than 0.05 was considered to show significant difference. RESULTS: The results of this study revealed that most of the quality indicators were improved in value after the water passed through the wetland except for alkalinity M, sulfite, Mn, temperature and pH. From ANOVA result, it was noted that there was a significant mean difference between the stations except for chromium, manganese and lead. The result showed that the wetland plays a great role in the removal of pollutants where the best performance was obtained at removal efficiency of 96.188% PO4HR,75.63% Nitrate,>99% Cl2, ammonia and nitrite 99.99%, 92.77% sulfate,84.36% Total hardness,87.43% color, and for others it is ranged between 30 and 60%. CONCLUSION: the study concluded that GMF wetland was almost effective and had potential in treatment of the wastewater from the discharging facilities (especially for nutrients, alkalinity P, hardness, color and chloride). It is recommended that wetlands should be conserved and used as wastewater treatment facility.


Assuntos
Águas Residuárias , Áreas Alagadas , Etiópia , Águas Residuárias/química , Eliminação de Resíduos Líquidos/métodos , Resíduos Industriais/análise , Metais Pesados/análise , Poluentes Químicos da Água/análise , Poaceae , Purificação da Água/métodos , Purificação da Água/normas
2.
Rev. salud pública ; 20(2): 204-207, mar.-abr. 2018. tab
Artigo em Espanhol | LILACS | ID: biblio-978959

RESUMO

RESUMEN Objetivo Analizar los resultados del Índice de Riesgo de la Calidad del Agua para Consumo Humano (IRCA) para los 116 municipios del Departamento de Cundinamarca, del año 2007 a 2013. Materiales y Métodos Información recolectada de los 116 municipios del Departamento de Cundinamarca, seleccionados y clasificados en función de los datos porcentuales del IRCA. Resultados Se observa una disminución del promedio anual del IRCA, lo cual refleja un mejoramiento de la calidad del agua entregada en el departamento; sin embargo, un 26,7% de municipios no reportan información de la zona rural y un 56,9% de los municipios reportan un IRCA superior a 5, que aunque se ubican en Riesgo Bajo, son un agua no apta para consumo humano. Conclusiones Se propone una nueva ponderación de los parámetros evaluados en el IRCA, con el fin de permitir que este índice sea más representativo del riesgo a la salud y, como estudios futuros un análisis estadístico concienzudo sobre el tamaño de la muestra que permita que los resultados obtenidos sean confiables para los tomadores de decisiones sobre el mejoramiento de la calidad del agua potable.(AU)


ABSTRACT Objective To analyze the results of the Water Quality Risk Index (IRCA) in the 116 municipalities of the department of Cundinamarca, between 2007 and 2013. Materials and Methods Information collected from the 116 municipalities of the department of Cundinamarca, selected and classified according to the percentage data retrieved by IRCA. Results A decrease of the annual IRCA average is observed, which reflects an improvement of the water quality delivered in the department. However, 26.7% of the municipalities do not report information from their rural areas, and 56.9% of the municipalities report IRCA figures over 5, which means that even though they are at low risk, they receive water unfit for human consumption. Conclusions A new weighting method for the parameters evaluated with the IRCA is proposed to make this index more representative of the risk to health. In addition, future studies should carry out a thorough statistical analysis on the size of the sample that allows the obtained results to be reliable for decision makers to improve the quality of drinking water.(AU)


Assuntos
Humanos , Abastecimento de Água/normas , Normas de Qualidade da Água , Doenças Transmitidas pela Água/epidemiologia , Epidemiologia Descritiva , Colômbia/epidemiologia , Purificação da Água/normas
3.
Rev. salud pública ; 19(6): 806-813, nov.-dic. 2017. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-962075

RESUMO

RESUMEN Objetivo Caracterizar la microbiota bacteriana presente en los biosólidos generados en una de las plantas de tratamiento de aguas residuales más grande de Colombia. Materiales y Métodos Se utilizó la plataforma de secuenciamiento 454 de la compañía Roche para secuenciar las regiones variables V1-V3 y V6-V9 del marcador molecular 16S rRNA y caracterizar la microbiota. Adicionalmente, se aplicaron estrategias filogenéticas para la identificación de especies bacterianas de importancia. Resultados Nuestros análisis muestran que los Phyla más abundantes son Chloro-flexi, Proteobacteria, Bacteroidetes, Actinobacteria y Firmicutes. Los géneros clasificados más abundantes fueron Pseudomonas, Dysgonomonas y Proteiniphilum. Sin embargo, el grupo dominante según la región variable V1-V3 es una Anaerolineaceae que no se ajusta a las especies descritas para esta familia. Conclusiones En las muestras de biosólido analizadas predominan bacterias ambientales que participan en los procesos de estabilización de la materia orgánica durante los tratamientos biológicos de tipo secundario y la digestión anaerobia. Se detectaron secuencias de especies dentro de la familia Anaerolineaceae, los análisis filogenéticos muestran que probablemente se trata de especies no descritas. En el momento del estudio, se encontró que en el sistema de digestión anaerobia se genera biosolido con una baja carga de bacterias potencialmente patógenas.(AU)


ABSTRACT Objective To describe bacterial microbiota in the biosolids generated in one of the largest wastewater treatment plants of Colombia. Materials and Methods Using NGS technology, 16S rRNA Gene Amplicon libraries were amplified and sequenced. The Roche 454 FLX Titanium platform was used, while the V1-V3 and V6-V9 hypervariable regions were amplified and analyzed independently. Amplicon processing and bacterial classification were performed using the AmpliconNoise pipeline and the RDP Classifier tool. Results The analysis showed that the most dominant Phyla in the biosolids were Chlo-roflexi, Proteobacteria, Bacteroidetes, Actinobacteria and Firmicutes. The most dominant genera were Pseudomonas, Dysgonomonas and Proteiniphilum; however, the dominant group according in the V1-V3 variable region was Anaerolineaceae, which does not conform to the species described for this family. Pathogenic bacteria such as Salmonella and E. coli/Shigella were not detected in the studied biosolid sample. Conclusions In the biosolids samples analyzed, environmental bacteria involved in organic matter stabilization processes during secondary biological treatments and anaerobic digestion were predominant. One of the dominant species in this sludge is a novel species of the Anaerolineaceae group. At the time of the study, it was found that the anaerobic digester system was able to maintain pathogenic bacteria at very low concentrations.(AU)


Assuntos
Esgotos/análise , RNA Ribossômico 16S , Purificação da Água/normas , Microbiota , Colômbia , Técnicas de Diagnóstico Molecular
4.
Rev. salud pública ; 18(2): 275-289, mar.-abr. 2016. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-783668

RESUMO

Objetivo Evaluar la eficiencia de dos sistemas de filtración casera: LifeStraw® family (FM) y Filtro de Olla Cerámica (FOC) en el tratamiento del agua para consumo humano bajo condiciones controladas de laboratorio y en términos de remoción de Turbiedad y E.coli. Métodos Ambos sistemas se operaron durante 6 meses tratando diariamente 7,5 litros de sustrato sintético. La turbiedad del sustrato se ajustó con Caolín y la concentración de E.coli con la réplica de la cepa ATCC 95922. Los resultados obtenidos en términos de remoción de turbiedad y E. coli fueron evaluados con un análisis de varianza (ANOVA) y considerando aspectos operativos y de mantenimiento. Resultados La turbiedad del sustrato sintético presentó un promedio 32,3 ± 2,8 UNT y la concentración de E. coli 3,9 x105 UFC/100mL. Ambos sistemas de filtración disminuyeron la turbiedad a niveles menores de 2 UNT y lograron la inactivación del 100 % de E.coli. Se encontraron diferencias significativas en la remoción de turbiedad siendo más eficiente el FM (99,2 % ± 0,4) que el FOC (97,6 % ± 1.14). Conclusiones Los dos sistemas de filtración son adecuados para el tratamiento del agua a nivel casero, cumpliendo con la reglamentación Colombiana. El FM resultó más eficiente en remoción de turbiedad y tasa de filtración; Sin embargo, cuando se tienen en cuenta aspectos como aceptabilidad social operación, mantenimiento y vida útil, el filtro de olla cerámica parece más apropiado especialmente en áreas rurales.(AU)


Objective To evaluate under laboratory conditions, the removal efficiency of turbidity and E. coli of two household water filters: LifeStraw® family (MF) and ceramic pot filter (CPF). Methods The two systems were operated over 6 months using two identical control units per system, treating 7.5 L/d of a synthetic substrate used as raw water. The turbidity of the substrate was adjusted with Kaolinite and the E. coli concentration, with a replica of the ATCC 95922 strain. The differences of effluent quality of the systems, in terms of turbidity and E. coli, were evaluated with Analysis of Variance (ANOVA). Operative and maintenance aspects, that could limit or enhance the use of the systems, were also considered in the evaluation. Results The water synthetic substrate quality had an average of 32.2 ± 2.8 NTU for turbidity and 3,9x105 UFC/100 mL for E. coli. Both systems reduce the turbidity to values below 2 NTU with an inactivation of 100 % of E. coli. Statistical differences were found between the systems in terms of turbidity removal, MF being more efficient than the CPF (99,2 ± 0.4 % and 97.6 % ± 1.14, respectively). Conclusions Both systems are suitable for household water supply treatment, acheiving the water quality standards established by Colombian regulations. The MF was more efficient for suspended solids removal and filtration rate, but when economic, operative, and maintenance aspects along with social acceptability and lifespan are considered, the CPF seems more suitable, especially in rural areas.(AU)


Assuntos
Humanos , Água Potável/análise , Turbidez da Água/análise , Purificação da Água/normas , Escherichia coli/isolamento & purificação , Filtração/métodos , Colômbia
5.
Rev. panam. salud pública ; 29(2): 120-125, Feb. 2011. mapas, tab
Artigo em Português | LILACS | ID: lil-579017

RESUMO

OBJETIVO: Avaliar a adequação dos níveis de fluoreto nas águas de abastecimento público em Curitiba, Estado do Paraná, Brasil, de acordo com duas técnicas (SPADNS e eletrométrica). MÉTODOS: Foram levantados os dados do heterocontrole na Cidade de Curitiba de janeiro de 2000 a julho de 2008 no banco de dados da Secretaria Municipal da Saúde para cálculo das médias anuais. Na sequência, foram comparadas as concentrações de fluoreto fornecidas pela companhia de saneamento SANEPAR (técnica eletrométrica) com as concentrações obtidas pelo heterocontrole (SPADNS) em 1 470 amostras de água coletadas e analisadas entre 2006 e 2007. Foi calculada a proporção de amostras dentro do padrão ideal de fluoretação para a Cidade (0,8 ppmF), abaixo do ideal e acima do ideal para ambas as metodologias. Foram exploradas diferenças na fluoretação entre distritos sanitários, meses do período dezembro de 2007 a julho de 2008 e estações de tratamento de água (ETA). RESULTADOS: A média geral de flúor entre 2000 a 2008 foi de 0,7 ppmF conforme os dados do heterocontrole. A comparação das técnicas eletrométrica e SPADNS revelou que o valor médio de fluoreto na água é maior quando avaliado pela técnica eletrométrica (0,743 ppmF ± 0,133) quando comparado com a técnica SPADNS (0,637 ppmF ± 0,164). A proporção de amostras dentro do padrão ideal de fluoretação foi de 15,05 por cento para SPADNS e 63,97 por cento para eletrométrica; de 62,03 e 22,85 por cento para amostras abaixo do ideal; e de 21,10 e 13,18 por cento para amostras acima do ideal, respectivamente. Houve diferença estatisticamente significativa na fluoretação entre os distritos sanitários (P < 0,001) e os meses pesquisados. CONCLUSÕES: A escolha da técnica analítica interfere significativamente no processo do heterocontrole. O heterocontrole deve utilizar a mesma técnica de determinação de flúor utilizada pela empresa de tratamento de água. Novos estudos devem definir qual técnica é a mais adequada para medir o teor de flúor.


OBJECTIVE: To evaluate the adequacy of fluoride levels in the public water system in Curitiba, state of Paraná, Brazil, as determined by two techniques (colorimetric and electrometric). METHODS: Data from independent measurements of fluoride in the public water system in Curitiba routinely performed by the city government were obtained for the period between January 2000 and July 2008. Mean levels of fluoride concentration were calculated for each of these years. After that, fluoride concentrations measured in 1 470 samples by the state water utility (SANEPAR) using the electrometric technique in 2006 and 2007 were compared with the corresponding levels measured by the city using the colorimetric method. The rate of samples meeting the standard for the city (0.8 ppmF), and below and above the standard, was calculated for both methods. Fluoride levels were compared between sanitary districts, months for the period between December 2007 and July 2008, and water treatment facilities. RESULTS: The overall mean fluoride level between 2000 and 2008 was 0.7 ppmF based on the independent measurements. The comparison between techniques showed a higher mean fluoride level with the electrometric technique (0.743 ppmF ± 0.133) vs. the colorimetric technique (0.637 ppmF ± 0.164). The rate of samples meeting the ideal standard of 0.8 ppmF was 15.05 percent for the colorimetric and 63.97 percent for the electrometric technique; 62.03 percent and 22.85 percent of the samples were below that standard and 21.10 percent and 13.18 percent were above that standard, respectively. Fluoride levels were statistically significant (P < 0.001) for the comparison between sanitary districts and months. CONCLUSIONS: The choice of technique significantly influences the resulting levels of fluoride. Independent monitoring of fluoride levels should employ the same technique used by the water utility. Further studies should aim at defining which technique is the most adequate to determine fluoride concentration in public water systems.


Assuntos
Colorimetria/métodos , Fluoretos/análise , Potenciometria/métodos , Abastecimento de Água/análise , Brasil , Cloro/análise , Fluoretação/normas , Reprodutibilidade dos Testes , Purificação da Água/métodos , Purificação da Água/normas , Abastecimento de Água/normas
6.
Cad. saúde pública ; 24(9): 2021-2031, set. 2008. graf, mapas, tab
Artigo em Português | LILACS | ID: lil-492644

RESUMO

O objetivo deste estudo foi analisar a concentração de flúor na água de abastecimento público em Chapecó, Santa Catarina, Brasil, no período de 1995 a 2005 e, adicionalmente, avaliar a efetividade de uma intervenção ocorrida em 2003 na qualidade da fluoretação. Foram analisadas 989 amostras de água. Para adequação da concentração de flúor as amostras foram classificadas obedecendo a três critérios utilizados no Brasil. Uma intervenção político-jurídica foi realizada pela municipalidade no ano de 2003. A fim de avaliar a tendência da fluoretação ao longo de todo período e antes e depois da intervenção, utilizou-se o procedimento de Prais-Winsten. Nos dez anos analisados, o sistema de fluoretação de águas apresentou 46 por cento, 32 por cento e 43 por cento de amostras adequadas, dependendo do critério adotado. Previamente à intervenção municipal, a proporção de amostras adequadas foi de 40 por cento, 26 por cento e 36 por cento, aumentando para 63 por cento, 49 por cento e 61 por cento após intervenção, segundo os diferentes critérios de análise. Verificou-se uma melhora na adequação da concentração de flúor após a intervenção municipal. Recomenda-se a continuidade da vigilância da fluoretação de águas, considerando-a processual e de caráter permanente.


This study aimed to analyze fluoride concentration in the public water supply in Chapecó, Santa Catarina State, Brazil, from 1995 to 2005 and to assess the effectiveness of a fluoridation quality intervention in 2003. A total of 989 water samples were analyzed. Fluoride concentrations were classified according to three different criteria used in Brazil. The city conducted a political and legal intervention in 2003. The Prais-Winsten procedure was used to evaluate the fluoride concentrations over time. In the ten years, the water fluoridation system showed 46 percent, 32 percent, and 43 percent of adequate samples, depending on the criterion. Prior to the municipal intervention, the proportion of adequate samples was 40 percent, 26 percent, and 36 percent, increasing to 63 percent, 49 percent, and 61 percent after the intervention, according to the three criteria. Fluoride concentration improved after the municipal intervention. On-going surveillance is recommended, including water fluoridation, dental caries, and dental fluorosis.


Assuntos
Fluoretação , Flúor/química , Purificação da Água/métodos , Brasil , Inquéritos de Saúde Bucal , Cárie Dentária/prevenção & controle , Fluoretação/normas , Fluorose Dentária/prevenção & controle , Controle de Qualidade , Saneamento , Purificação da Água/normas
7.
Rev. invest. clín ; 58(5): 470-474, sep.-oct. 2006. tab
Artigo em Espanhol | LILACS | ID: lil-632415

RESUMO

Objective. To know the quality of the water from hospitals and the risks that poor chlorination implies. Methods. We analyzed 90 water specimens from 15 hospitals (9 from the private and 6 from the public sector). Specimens were obtained from three areas (hospitalization ward, operating room, and kitchen) in two visits. Results. By microbiologic analysis, we found 30 (33.3 %) contaminated specimens. By chemical analysis, we found only 49 (54.5 %) specimens with adequate chlorination (> 1 mg/L). Of the 30 contaminated specimens, only 7 (23.3%) had adequate chlorination. On the other hand, of the 60 specimens without contamination, 42 (79%) had adequate chlorination (x2 - 17.561, p < 0.001). The significant difference was sustained when the criterion for appropriate chlorination was established at > 0.5 mg/L. Conclusions. Hospitals require guidelines for water chlorination and testing to maintain it at > 0.5 mg/L in every point of use.


Objetivo. Conocer la calidad del agua en hospitales y los riesgos de contaminación bacteriana por cloración insuficiente. Material y métodos. Analizamos 90 especímenes de agua de 15 hospitales (nueve del sector privado y seis del público). Los especímenes se obtuvieron de tres áreas (hospitalización, quirófano y cocina) en dos visitas diferentes. Resultados. Por análisis microbiológico, encontramos 30 de los 90 especímenes contaminados (33.3%). Por análisis químico, encontramos que sólo 49 (54.4%) especímenes tuvieron cloración suficiente (> 1 mg/L). De los 30 especímenes contaminados sólo siete (23.3%) tenían cloración suficiente. Por otro lado, de los 60 especímenes sin contaminación, 42 (79%) tenían cloración suficiente (x2 = 17.561, p < 0.001). La significancia se sostuvo al considerar como criterio de cloración suficiente un nivel > 0.5 mg/L. Conclusiones. Todo hospital requiere un manual de cloración del agua y verificar que mantenga niveles mínimos de 0.5 mg/L en todas las áreas.


Assuntos
Cloro , Hospitais/normas , Microbiologia da Água/normas , Purificação da Água/normas
8.
Rev. panam. salud pública ; 14(6): 385-393, dic. 2003. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-355665

RESUMO

OBJETIVO: Avaliar o potencial de contaminaçäo de águas residuárias da suinocultura. MÉTODOS: As águas residuárias da suinocultura foram estocadas em um tanque. Depois de 0, 30, 60, 90 e 120 dias de retençäo hidráulica, foram incorporadas em lisímetros preenchidos com solos argilosos, arenosos e médios. Esses lisímetros foram entäo submetidos à simulaçäo de duas condiçöes climáticas: estaçäo de chuvas e estiagem. O número de unidades formadoras de colônias de coliformes totais, coliformes fecais e estreptococos fecais foi medido nos efluentes do tanque de estocagem (para os diversos períodos de retençäo hidráulica), nos percolados dos lisímetros e nos três tipos de solo. As análises microbiológicas foram realizadas através da técnica de membrana filtrante. As análises de pH foram realizadas potenciometricamente. RESULTADOS: Para os três microrganismos, as reduçöes bacterianas máximas no tanque de estocagem foram obtidas a partir de 90 dias de retençäo. A quantificaçäo bacteriana nos percolados dos três solos foi caracterizada por reduçöes elevadas. Em relaçäo aos três tipos de solo, os maiores valores de reduçäo bacteriana foram verificados nos solos médios, devido à sua acidez (pH < 7,0). Para os coliformes fecais a retençäo hidráulica näo foi suficiente para permitir a adequaçäo sanitária das águas residuárias e sua utilizaçäo na irrigaçäo (valores acima de 1 000 UFC.100 mL-1). Nesse caso, a incorporaçäo desses resíduos nos solos foi caracterizada como uma segunda etapa de tratamento. CONCLUSÖES: A retençäo da água residuária, seguida da aplicaçäo no solo, mostrou-se eficiente na minimizaçäo do efeito contaminante dos resíduos da suinocultura. Recomenda-se uma diminuiçäo no tempo de estocagem das águas residuárias da suinocultura, de 120 para 90 dias


Objective. To assess the potential for contamination of wastewaters from pig farming. Methods. Wastewaters from pig farming were stored in a tank. After 0, 30, 60, 90, and 120 days of hydraulic retention, they were added to lysimeters filled with argillaceous, sandy, or medium soil. Finally, these lysimeters were submitted to simulations of either a rainy season or a dry season. The number of colony-forming units (CFUs) of total coliforms, fecal coliforms, and fecal streptococci was measured in the effluents of the storage tank (for the various periods of hydraulic retention), in the percolate from the lysimeters, and in the three types of soil. The microbiological analyses were carried out using the membrane filter technique. The pH analyses were done potentiometrically. Results. For the three microorganisms, the largest decrease in bacterial counts in the storage tanks occurred with 90 or 120 days of retention. There was a marked decrease in the bacterial count in the percolates of the three soils. For the three soil types the greatest reduction in bacterial counts was found in medium soil, due to its acidity (pH < 7.0). Hydraulic retention was not sufficient to ensure the sanitary adequacy of the wastewaters and their use for irrigation, given that fecal coliform values were above 1 000 CFU per 100 mL. Therefore, adding the residues to the soil was considered a second stage of treatment. Conclusions. The retention of wastewaters followed by adding them to soil was effective in minimizing the contaminating effect of pig farming residues. The storage time for wastewaters from pig farming could be decreased from 120 to 90 days


Assuntos
Animais , Criação de Animais Domésticos , Microbiologia da Água , Purificação da Água/normas , Brasil , Suínos
9.
Artigo em Espanhol | PAHO | ID: pah-34664

RESUMO

A gravity-operated mechanism for measuring fluoride dosage is described. It would be suitable for rural areas and communities which lack the funds to purchase an electric mechanism, or which have not electricity


The fluoridator described has functioned with proved accuracy for the four years of the test, in a community whose aqueduct has a constant flow of 12 liters per second and whose population is 4,500 inhabitants


The cost of the accessories and tanks which make up the fluoridator is only 2,420 Colombian pesos, or US$138.28


The fluoridator parts are simple, easy to obtain, economical and safe. These qualities make it feasible to build and use in any area. Moreover, because of its simplicity, and ordinary workman can operate it with easily understood instructions and with the assurance that there is no risk of any kind(AU)


Assuntos
Purificação da Água/métodos , Purificação da Água/economia , Purificação da Água/normas , Fluoretação/métodos , Fluoretação/economia , Saúde da População Rural , Colômbia
10.
Rev. bras. odontol ; 50(4): 22-30, jul.-ago. 1993. ilus, tab
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: lil-168403

RESUMO

Os autores revisam benefícios e controvérsias sobre o Flúor Tópico e Sistêmico nos programas de abastecimento público de água e bochecho semanal com soluçäo de fluoreto de sódio a 0,2 por cento em escolares de 6 a 12 anos da rede pública de ensino. Apresentam levantamentos epidemiológicos, analisando o percentual da reduçäo de cárie em diversos municípios do Estado do Paraná bem como analisam a implantaçäo e evoluçäo dos programas de prevençäo da cárie dentária no Estado


Assuntos
Humanos , Masculino , Feminino , Criança , Antissépticos Bucais/administração & dosagem , Antissépticos Bucais/análise , Cárie Dentária/epidemiologia , Cárie Dentária/prevenção & controle , Odontologia Comunitária , Halogenação , Fluoretos , Fluoretos Tópicos , Programas Nacionais de Saúde , Fluoreto de Sódio , Odontologia Estatal , Purificação da Água/normas