Your browser doesn't support javascript.
loading
Angioplastia guiada por ultrassom intracoronariano: metanálise de ensaios clínicos randomizados / Angioplasty guided by intravascular ultrasound: meta-analysis of randomized clinical trials
Figueiredo Neto, José Albuquerque de; Nogueira, Iara Antonia Lustosa; Figueiro, Mabel Fernandes; Buehler, Anna Maria; Berwanger, Otavio.
Afiliação
  • Figueiredo Neto, José Albuquerque de; Universidade Federal do Maranhão. São Luiz. BR
  • Nogueira, Iara Antonia Lustosa; Universidade Federal do Maranhão. São Luiz. BR
  • Figueiro, Mabel Fernandes; Universidade Federal do Maranhão. São Luiz. BR
  • Buehler, Anna Maria; Universidade Federal do Maranhão. São Luiz. BR
  • Berwanger, Otavio; Universidade Federal do Maranhão. São Luiz. BR
Arq. bras. cardiol ; Arq. bras. cardiol;101(2): 106-116, ago. 2013. ilus, tab
Article em Pt | LILACS | ID: lil-685388
Biblioteca responsável: BR1.1
RESUMO
FUNDAMENTO O impacto do uso do ultrassom intracoronariano (USIC) na implantação de stents tem resultados inconclusivos.

OBJETIVO:

Revisão sistemática, com metanálise, do impacto do USIC na implantação de stents quanto à evolução clínica e angiográfica.

MÉTODOS:

Efetuada busca nas bases Medline/Pubmed, CENTRAL, Embase, Lilacs, Scopus e Web of Science. Incluídos estudos clínicos randomizados (ECR) que avaliaram o implante de stents, orientados pela USIC, comparados com aqueles utilizando a angiografia isoladamente (ANGIO). O intervalo mínimo de acompanhamento foi de seis meses, avaliados os desfechos trombose, mortalidade, infarto do miocárdio, revascularização percutânea e cirúrgica, eventos cardiovasculares maiores (ECVM) e reestenose. Os desfechos binários foram apresentados considerando o número de eventos em cada grupo; as estimativas foram geradas por um modelo de efeitos aleatórios, considerando a estatística de Mantel-Haenzel como ponderadora e magnitude de efeito ao risco relativo (RR) com seu respectivo intervalo de confiança de 95% (IC 95%). Para quantificação da consistência entre os resultados de cada estudo, utilizou-se o teste de inconsistência I² de Higgins.

RESULTADOS:

Avaliados 2.689 artigos, incluídos 8 ECR. Houve redução de 27% na reestenose angiográfica (RR 0,73; IC 95% 0,54 - 0,97; I² = 51%) e redução estatisticamente significativa nas taxas de revascularizações percutânea e geral (RR 0,88; IC 95% 0,51 - 1,53; I² = 61% e RR 0,73; IC 95% 0,54 - 0,99; I² = 55%), sem diferença estatística na revascularização cirúrgica (RR 0,95; IC 95% 0,52 - 1,74; I² = 0%) em favor do USIC vs. ANGIO. Não foram observadas diferenças nos demais desfechos na comparação entre as duas estratégias.

CONCLUSÃO:

Angioplastias com implante de stents guiadas por USIC reduzem taxas de reestenose e de revascularizações, não tendo impacto nos desfechos ECVM, infarto agudo do miocárdio, mortalidade ou trombose.
ABSTRACT

BACKGROUND:

The impact of intravascular ultrasound (IVUS) use on stenting has shown inconclusive results.

OBJECTIVE:

Systematic review and meta-analysis of the impact of IVUS on stenting regarding the clinical and angiographic evolution.

METHODS:

A search was performed in Medline/Pubmed, CENTRAL, Embase, Lilacs, Scopus and Web of Science databases. It included randomized clinical trials (RCTs) that evaluated the implantation of stents guided by IVUS, compared with those using angiography alone (ANGIO). The minimum follow-up duration was six months and the following outcomes were assessed thrombosis, mortality, myocardial infarction, percutaneous and surgical revascularization, major adverse cardiovascular events (MACE) and restenosis. The binary outcomes were presented considering the number of events in each group; the estimates were generated by a random effects model, considering Mantel-Haenszel statistics as weighting agent and magnitude of effect for the relative risk (RR) with its respective 95% confidence interval (95%CI). Higgins I² test was used to quantify the consistency between the results of each study.

RESULTS:

A total of 2,689 articles were evaluated, including 8 RCTs. There was a 27% reduction in angiographic restenosis (RR 0.73, 95% CI 0.54-0.97, I² = 51%) and statistically significant reduction in the rates of percutaneous revascularization and overall (RR 0.88; 95% CI 0.51 to 1.53, I² = 61%, RR 0.73, 95% CI 0.54 to 0.99, I² = 55%), with no statistical difference in surgical revascularization (RR 0.95, 95% CI 0.52-1.74, I² = 0%) in favor of IVUS vs. ANGIO. There were no differences regarding the other outcomes in the comparison between the two strategies.

CONCLUSION:

Angioplasty with stenting guided by IVUS decreases the rates of restenosis and revascularization, with no impact on MACE, acute myocardial infarction, mortality or thrombosis outcomes.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: LILACS Assunto principal: Angioplastia Coronária com Balão / Ultrassonografia de Intervenção / Stents Farmacológicos Tipo de estudo: Clinical_trials / Etiology_studies / Prognostic_studies / Risk_factors_studies / Systematic_reviews Limite: Humans Idioma: Pt Revista: Arq. bras. cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Base de dados: LILACS Assunto principal: Angioplastia Coronária com Balão / Ultrassonografia de Intervenção / Stents Farmacológicos Tipo de estudo: Clinical_trials / Etiology_studies / Prognostic_studies / Risk_factors_studies / Systematic_reviews Limite: Humans Idioma: Pt Revista: Arq. bras. cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Brasil