Your browser doesn't support javascript.
loading
Alternative antibody for the detection of CA19-9 antigen: a European multicenter study for the evaluation of the analytical and clinical performance of the Access GI Monitor assay on the UniCel Dxl 800 Immunoassay System.
Stieber, Petra; Molina, Rafael; Gion, Massimo; Gressner, Axel; Troalen, Frédéric; Holdenrieder, Stefan; Auge, Jose Maria; Zancan, Matelda; Wycislo, Matthias; Jarrige, Véronique.
Afiliação
  • Stieber P; Institut für Klinische Chemie, Klinikum der Universität Munchen, Munich, Germany. Petra.Stieber@med.uni-muenchen.de
Clin Chem Lab Med ; 46(5): 600-11, 2008.
Article em En | MEDLINE | ID: mdl-18598202
ABSTRACT

BACKGROUND:

Gastrointestinal cancer antigen CA19-9 is known as a valuable marker for the management of patients with pancreatic cancer.

METHODS:

The analytical and clinical performance of the Access GI Monitor assay (Beckman Coulter) was evaluated on the UniCel Dxl 800 Immunoassay System at five different European sites and compared with a reference method, defined as CA19-9 on the Elecsys System (Roche Diagnostics).

RESULTS:

Total imprecision (%CV) of the GI Monitor ranged between 3.4% and 7.7%, and inter-laboratory reproducibility between 3.6% and 4.0%. Linearity upon dilution showed a mean recovery of 97.4% (SD + 7.2%). Endogenous interferents had no influence on GI Monitor levels (mean recoveries hemoglobin 103%, bilirubin 106%, triglycerides 106%). There was no high-dose hook effect up to 115,000 kU/L. Clinical performance investigated in sera from 1811 individuals showed a good correlation between the Access GI Monitor and Elecsys CA19-9 (R = 0.959, slope = 1.004, intercept = +0.17). GI Monitor serum levels were low in healthy individuals (n = 267, median = 6.0 kU/L, 95th percentile=23.1 kU/L), higher in individuals with various benign diseases (n = 550, medians = 5.8-13.4 kU/L, 95th percentiles = 30.1-195.5 kU/L) and even higher in individuals suffering from various cancers (n = 995, medians = 8.4-233.8 kU/L, 95th percentiles = 53.7-13,902 kU/L). Optimal diagnostic accuracy for cancer detection against the relevant benign control group by the GI Monitor was found for pancreatic cancer [area under the curve (AUC) 0.83]. Results for the reference CA19-9 assay were comparable (AUC 0.85).

CONCLUSIONS:

The Access GI Monitor provides very good methodological characteristics and demonstrates an excellent analytical and clinical correlation with the Elecsys CA19-9. The GI Monitor shows the best diagnostic accuracy in pancreatic cancer. Our results also suggest a clinical value of the GI Monitor in other cancers.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Pancreáticas / Imunoensaio / Antígeno CA-19-9 / Anticorpos Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Pancreáticas / Imunoensaio / Antígeno CA-19-9 / Anticorpos Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Alemanha