Your browser doesn't support javascript.
loading
The role of epicardial echocardiography in the measurement of transvalvular flow velocities during aortic valve replacement.
Taneja, Ravi; Quaghebeur, Bert; Stitt, Larry W; Quantz, Mackenzie A; Guo, Lin R; Kiaii, Bob; Bainbridge, Daniel T.
Afiliação
  • Taneja R; Department of Anesthesia and Perioperative Medicine, London Health Sciences Centre, University of Western Ontario, London, Ontario, Canada. Ravi.Taneja@lhsc.on.ca
J Cardiothorac Vasc Anesth ; 23(3): 292-7, 2009 Jun.
Article em En | MEDLINE | ID: mdl-19464624
OBJECTIVE: The purpose of this study was to compare transvalvular flow velocities obtained by transesophageal echocardiography and epicardial echocardiography (EE) during aortic valve replacement (AVR). DESIGN: Prospective observational study. SETTING: University hospital. PARTICIPANTS: Patients undergoing AVR for aortic stenosis. INTERVENTIONS: After institutional review board approval, 17 patients undergoing AVR consented. Deep transgastric (deep TG LAX) and transgastric long-axis (TG LAX) views and epicardial aortic valve long-axis views (S8 probe) were obtained on a SONOS 5500 (Phillips Medical Systems, Bothell, WA) before and after AVR. Transvalvular flow velocity and velocity time integral (VTI) were recorded via each technique. Measurements were made offline by 2 independent reviewers. Agreement between measurements made by different views was evaluated by using Bland-Altman analysis. MEASUREMENTS AND MAIN RESULTS: The epicardial probe was well tolerated. Quality images were obtained in all patients with TEE and 30 of 34 studies via epicardial scanning. The mean bias for peak velocities derived through EE and deep TG LAX was 96.3 cm/s (95% confidence interval [CI], 51.1-141.4) before AVR and 58 cm/s (95% CI, 32.4-83.7) after AVR. The mean bias for peak velocities between EE and TG LAX was 70 cm/s (95% CI, 31.1-108.9) before and 84.7 cm/s (95% CI, 55.6-113.7) after AVR. Similar results were obtained for VTI. CONCLUSIONS: Peak transaortic valve velocities and VTI measured with epicardial echocardiography are higher in comparison to measurements via TEE in patients undergoing AVR. The precise role of epicardial echocardiography in the comprehensive echocardiographic examination of patients undergoing aortic valve replacement needs further evaluation.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Pericárdio / Ecocardiografia Transesofagiana / Implante de Prótese de Valva Cardíaca Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiothorac Vasc Anesth Assunto da revista: ANESTESIOLOGIA / CARDIOLOGIA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Pericárdio / Ecocardiografia Transesofagiana / Implante de Prótese de Valva Cardíaca Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiothorac Vasc Anesth Assunto da revista: ANESTESIOLOGIA / CARDIOLOGIA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Canadá