Your browser doesn't support javascript.
loading
Combination of Edman degradation of peptides with liquid chromatography/mass spectrometry workflow for peptide identification in bottom-up proteomics.
Lobas, Anna A; Verenchikov, Anatoly N; Goloborodko, Anton A; Levitsky, Lev I; Gorshkov, Mikhail V.
Afiliação
  • Lobas AA; Institute for Energy Problems of Chemical Physics, Russian Academy of Sciences, Moscow, Russia.
Rapid Commun Mass Spectrom ; 27(3): 391-400, 2013 Feb 15.
Article em En | MEDLINE | ID: mdl-23280970
ABSTRACT
RATIONALE High-throughput methods of proteomics are essential for identification of proteins in a cell or tissue under certain conditions. Most of these methods require tandem mass spectrometry (MS/MS). A multidimensional approach including predictive chromatography and partial chemical degradation could be a valuable alternative and/or addition to MS/MS.

METHODS:

In the proposed strategy peptides are identified in a three-dimensional (3D) search space consisting of retention time (RT), mass, and reduced mass after one-step partial Edman degradation. The strategy was evaluated in silico for two databases baker's yeast and human proteins. Rates of unambiguous identifications were estimated for mass accuracies from 0.001 to 0.05 Da and RT prediction accuracies from 0.1 to 5 min. Rates of Edman reactions were measured for test peptides.

RESULTS:

A 3D description of proteolytic peptides allowing unambiguous identification without employing MS/MS of up to 95% and 80% of tryptic peptides from the yeast and human proteomes, respectively, was considered. Further extension of the search space to a four-dimensional one by incorporating the second N-terminal amino acid residue as the fourth dimension was also considered and was shown to result in up to 90% of human peptides being identified unambiguously.

CONCLUSIONS:

The proposed 3D search space can be a useful alternative to MS/MS-based peptide identification approach. Experimental implementations of the proposed method within the on-line liquid chromatography/mass spectrometry (LC/MS) and off-line matrix-assisted laser desorption/ionization (MALDI) workflows are in progress.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos Organofosforados / Fragmentos de Peptídeos / Cromatografia Líquida de Alta Pressão / Proteômica / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Rapid Commun Mass Spectrom Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Federação Russa

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos Organofosforados / Fragmentos de Peptídeos / Cromatografia Líquida de Alta Pressão / Proteômica / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Rapid Commun Mass Spectrom Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Federação Russa