Stent graft surface movement after infrarenal abdominal aortic aneurysm repair: comparison of patients with and without a type 2 endoleak.
Nolz, R; Schwartz, E; Langs, G; Loewe, C; Wibmer, A G; Prusa, A M; Teufelsbauer, H; Schoder, M.
Afiliação
  • Nolz R; Department of Biomedical Imaging and Image-guided Therapy, Division of Cardiovascular and Interventional Radiology, Medical University of Vienna, Vienna, Austria. Electronic address: richard.nolz@meduniwien.ac.at.
  • Schwartz E; Department of Biomedical Imaging and Image-guided Therapy, Computational and Imaging Research Laboratory, Medical University of Vienna, Vienna, Austria.
  • Langs G; Department of Biomedical Imaging and Image-guided Therapy, Computational and Imaging Research Laboratory, Medical University of Vienna, Vienna, Austria.
  • Loewe C; Department of Biomedical Imaging and Image-guided Therapy, Division of Cardiovascular and Interventional Radiology, Medical University of Vienna, Vienna, Austria.
  • Wibmer AG; Department of Biomedical Imaging and Image-guided Therapy, Division of Cardiovascular and Interventional Radiology, Medical University of Vienna, Vienna, Austria.
  • Prusa AM; Department of Surgery, Division of Vascular Surgery, Medical University of Vienna, Vienna, Austria.
  • Teufelsbauer H; Department of Surgery, Division of Vascular Surgery, Medical University of Vienna, Vienna, Austria.
  • Schoder M; Department of Biomedical Imaging and Image-guided Therapy, Division of Cardiovascular and Interventional Radiology, Medical University of Vienna, Vienna, Austria.
Eur J Vasc Endovasc Surg ; 50(2): 181-8, 2015 Aug.
Article em En | MEDLINE | ID: mdl-25920628
OBJECTIVES: The aim was to compare multidirectional stent graft movement in patients with and without a type 2 endoleak. METHODS: This was a retrospective case control study of patients being followed up after elective endovascular aneurysm repair of abdominal aortic aneurysms. The post-procedural and final follow up multislice computed tomography (MSCT) of 69 patients with and 74 without a type 2 endoleak were analyzed. Three dimensional (3D) surface models of the stent graft, delimited by landmarks using custom built software, were derived from these MSCT data. The stent graft was segmented in different zones, and the proportion of the total stent graft surface moving >9 mm between the post-procedural and the final follow up MSCT was calculated, given in percentages, and compared between groups. Changes of infrarenal neck, renal artery to stent graft distance, and freedom from stent graft related endoleaks were evaluated. RESULTS: Overall surface movement was higher in the no endoleak (18.8%, IQR 0.1-45.1%) than in the type 2 endoleak group (5.3%, IQR 0-29.7%; p = .06). Furthermore, significantly higher surface movement in the no endoleak group was found in the proximal anchoring zone (p = .04) and the distal left limb (p = .01), which was the modular limb in 81.1% (p < .01). Neck diameter increase (1.0 mm, IQR 0-3.0 mm; p < .01) and renal artery to stent graft distance difference (0 mm, IQR 0-3.3 mm; p < .01) were significantly higher in the no endoleak group. Five patients in the no endoleak and one patient in the type 2 endoleak group suffered from a stent graft related endoleak (p = .27). CONCLUSIONS: The presence of a type 2 endoleak is associated with decreased surface movement of the proximal anchoring zone and the distal modular limb of bifurcated stent grafts.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Prótese Vascular / Stents / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Endoleak / Procedimentos Endovasculares Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Eur J Vasc Endovasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Prótese Vascular / Stents / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Endoleak / Procedimentos Endovasculares Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Eur J Vasc Endovasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2015 Tipo de documento: Article