[Effects of posterior chamber phakic intraocular lens on axial length measurements].
Zhonghua Yan Ke Za Zhi ; 51(3): 206-9, 2015 Mar.
Article em Zh | MEDLINE | ID: mdl-26268644
ABSTRACT

OBJECTIVE:

To study the effects of posterior chamber phakic intraocular lens (IOL) on axial length (AL) measurements and whether a correction factor for later IOL power calculation before cataract surgery is necessary.

METHODS:

Twenty-two high myopic patients (39 eyes) with mean spherical equivalent -19.00 +/- 4.03 D received phakic refractive lens (PRL) implantation, and 24 patients (40 eyes) with mean spherical equivalent (-13.10 +/- 2.53) D received implantable Collamer lens (ICL) implantation. Pre-and postoperative AL measurements with the IOLMaster were compared. Results The pre-and postoperative ALs were (30.87 +/- 2.18) mm and (30.94 +/- 2.16) mm, respectively (t = -2.635, P = 0.012) in the PRL group, and (28.35 +/- 1.20) mm and (28.45 +/- 1.22) mm, respectively ( t = -3.97, P < 0.001) in the ICL group. Linear regression analysis showed in the PRL group, preoperative AL = 1.01 x postoperative AL-0.24 (R2 = 0.99, P < 0.001), or postoperative AL--preoperative AL = 0.24-0.0055 x postoperative AL; in the ICL group, preoperative AL = 0.96 x postoperative AL +1.17 (R2 = 0.99, P < 0.001), or postoperative AL--preoperative AL = 0.0154 x postoperative AL -0.3763. The mean differences between pre-and postoperative ALs in the PRL and, ICL groups were 0.075 mm and 0.054 mm, respectively.

CONCLUSIONS:

Based on the SRK formula, a < 0.1 mm AL difference would result in a <0.25 D change in the calculated IOL power, possibly a < 0.20 D change in manifest refraction. Furthermore, for PRL, the longer the AL, the smaller the difference between pre-and postoperative ALs. These differences are so small that it is unnecessary to correct IOL power calculation.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Extração de Catarata / Implante de Lente Intraocular / Olho / Lentes Intraoculares Fácicas / Miopia Tipo de estudo: Prognostic_studies Limite: Humans Idioma: Zh Revista: Zhonghua Yan Ke Za Zhi Ano de publicação: 2015 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Extração de Catarata / Implante de Lente Intraocular / Olho / Lentes Intraoculares Fácicas / Miopia Tipo de estudo: Prognostic_studies Limite: Humans Idioma: Zh Revista: Zhonghua Yan Ke Za Zhi Ano de publicação: 2015 Tipo de documento: Article