Your browser doesn't support javascript.
loading
Use of Remote Pulmonary Artery Pressure Monitoring (CardioMEMS System) in Total Artificial Heart to Assess Pulmonary Hemodynamics for Heart Transplantation.
Gohar, Salman; Taimeh, Ziad A; Morgan, Jeffrey A; Frazier, O H; A Arabia, Francisco; Civitello, Andrew B; Nair, Ajith P.
Afiliação
  • Gohar S; From the Division of Cardiothoracic Transplant and Assist Devices, Baylor College of Medicine, Houston, TX.
  • Taimeh ZA; Department of Cardiopulmonary Transplantation and the Center for Cardiac Support, Texas Heart Institute, Houston, TX.
  • Morgan JA; From the Division of Cardiothoracic Transplant and Assist Devices, Baylor College of Medicine, Houston, TX.
  • Frazier OH; Department of Cardiopulmonary Transplantation and the Center for Cardiac Support, Texas Heart Institute, Houston, TX.
  • A Arabia F; From the Division of Cardiothoracic Transplant and Assist Devices, Baylor College of Medicine, Houston, TX.
  • Civitello AB; Department of Cardiopulmonary Transplantation and the Center for Cardiac Support, Texas Heart Institute, Houston, TX.
  • Nair AP; From the Division of Cardiothoracic Transplant and Assist Devices, Baylor College of Medicine, Houston, TX.
ASAIO J ; 64(4): e75-e77, 2018.
Article em En | MEDLINE | ID: mdl-29135479
The temporary total artificial heart (TAH-t) has been valuable as a bridge to transplantation in patients with biventricular failure. However, the challenges of accurately assessing pulmonary vascular resistance after TAH-t implantation can preclude these patients from heart transplantation, especially those with pre-existing pulmonary hypertension. The CardioMEMS Heart Failure System (St. Jude's Medical, Little Canada, MN) comprises a wireless pressure sensor that is implanted percutaneously in the pulmonary artery and transmits real-time measurements of pulmonary artery pressures. Systolic and diastolic pulmonary artery (PA) pressures measurements have been well correlated between the CardioMEMS PA Sensor and traditional Swan-Ganz catheter and between the CardioMEMS PA Sensor and standard echocardiography. Here, we report the use of the CardioMEMS device in a patient with severe pulmonary hypertension supported with a SynCardia TAH-t (Tucson, AZ) during assessment for candidacy for transplantation.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transdutores de Pressão / Resistência Vascular / Monitores de Pressão Arterial / Transplante de Coração / Coração Artificial Limite: Adult / Humans / Male Idioma: En Revista: ASAIO J Assunto da revista: TRANSPLANTE Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transdutores de Pressão / Resistência Vascular / Monitores de Pressão Arterial / Transplante de Coração / Coração Artificial Limite: Adult / Humans / Male Idioma: En Revista: ASAIO J Assunto da revista: TRANSPLANTE Ano de publicação: 2018 Tipo de documento: Article