Your browser doesn't support javascript.
loading
Detection and Characterization of Solid Pulmonary Nodules at Digital Chest Tomosynthesis: Data from a Cohort of the Pilot Swedish Cardiopulmonary Bioimage Study.
Meltzer, Carin; Vikgren, Jenny; Bergman, Bengt; Molnar, David; Norrlund, Rauni Rossi; Hassoun, Asmaa; Gottfridsson, Bengt; Båth, Magnus; Johnsson, Åse A.
Afiliação
  • Meltzer C; From the Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sweden (C.M., J.V., D.M., R.R.N., Å.A.J.), Department of Radiology and Nuclear Medicine at Oslo University Hospital, Ullevål, Norway (C.M.), Department of Radiology, Sahlgrenska Univers
  • Vikgren J; From the Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sweden (C.M., J.V., D.M., R.R.N., Å.A.J.), Department of Radiology and Nuclear Medicine at Oslo University Hospital, Ullevål, Norway (C.M.), Department of Radiology, Sahlgrenska Univers
  • Bergman B; From the Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sweden (C.M., J.V., D.M., R.R.N., Å.A.J.), Department of Radiology and Nuclear Medicine at Oslo University Hospital, Ullevål, Norway (C.M.), Department of Radiology, Sahlgrenska Univers
  • Molnar D; From the Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sweden (C.M., J.V., D.M., R.R.N., Å.A.J.), Department of Radiology and Nuclear Medicine at Oslo University Hospital, Ullevål, Norway (C.M.), Department of Radiology, Sahlgrenska Univers
  • Norrlund RR; From the Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sweden (C.M., J.V., D.M., R.R.N., Å.A.J.), Department of Radiology and Nuclear Medicine at Oslo University Hospital, Ullevål, Norway (C.M.), Department of Radiology, Sahlgrenska Univers
  • Hassoun A; From the Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sweden (C.M., J.V., D.M., R.R.N., Å.A.J.), Department of Radiology and Nuclear Medicine at Oslo University Hospital, Ullevål, Norway (C.M.), Department of Radiology, Sahlgrenska Univers
  • Gottfridsson B; From the Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sweden (C.M., J.V., D.M., R.R.N., Å.A.J.), Department of Radiology and Nuclear Medicine at Oslo University Hospital, Ullevål, Norway (C.M.), Department of Radiology, Sahlgrenska Univers
  • Båth M; From the Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sweden (C.M., J.V., D.M., R.R.N., Å.A.J.), Department of Radiology and Nuclear Medicine at Oslo University Hospital, Ullevål, Norway (C.M.), Department of Radiology, Sahlgrenska Univers
  • Johnsson ÅA; From the Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sweden (C.M., J.V., D.M., R.R.N., Å.A.J.), Department of Radiology and Nuclear Medicine at Oslo University Hospital, Ullevål, Norway (C.M.), Department of Radiology, Sahlgrenska Univers
Radiology ; 287(3): 1018-1027, 2018 06.
Article em En | MEDLINE | ID: mdl-29613826
ABSTRACT
Purpose To investigate the performance of digital tomosynthesis (DTS) for detection and characterization of incidental solid lung nodules. Materials and Methods This prospective study was based on a population study with 1111 randomly selected participants (age range, 50-64 years) who underwent a medical evaluation that included chest computed tomography (CT). Among these, 125 participants with incidental nodules 5 mm or larger were included in this study, which added DTS in conjunction with the follow-up CT and was performed between March 2012 and October 2014. DTS images were assessed by four thoracic radiologists blinded to the true number of nodules in two separate sessions according to the 5-mm (125 participants) and 6-mm (55 participants) cut-off for follow-up of incidental nodules. Pulmonary nodules were directly marked on the images by the readers and graded regarding confidence of presence and recommendation for follow-up. Statistical analyses included jackknife free-response receiver operating characteristic, receiver operating characteristic, and Cohen κ coefficient. Results Overall detection rate ranges of CT-proven nodules 5 mm or larger and 6 mm or larger were, respectively, 49%-58% and 48%-62%. Jackknife free-response receiver operating characteristics figure of merit for detection of CT-proven nodules 5 mm or larger and 6 mm or larger was 0.47 and 0.51, respectively, and area under the receiver operating characteristic curve regarding recommendation for follow-up was 0.62 and 0.65, respectively. Conclusion Routine use of DTS would result in lower detection rates and reduced number of small nodules recommended for follow-up. © RSNA, 2018.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Nódulos Pulmonares Múltiplos / Neoplasias Pulmonares Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Radiology Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Nódulos Pulmonares Múltiplos / Neoplasias Pulmonares Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Radiology Ano de publicação: 2018 Tipo de documento: Article