Your browser doesn't support javascript.
loading
Detection capability of quantitative faecal immunochemical tests for haemoglobin (FIT) and reporting of low faecal haemoglobin concentrations.
Fraser, Callum G; Benton, Sally C.
Afiliação
  • Fraser CG; Centre for Research into Cancer Prevention and Screening, University of Dundee, Ninewells Hospital and Medical School, Dundee DD1 9SY, Scotland, UK.
  • Benton SC; NHS Bowel Cancer Screening Programme, Southern Hub, Royal Surrey County Hospital NHS Foundation Trust, Guildford, Surrey, UK.
Clin Chem Lab Med ; 57(5): 611-616, 2019 04 24.
Article em En | MEDLINE | ID: mdl-29995629
Faecal immunochemical tests for haemoglobin (FIT) are widely used in asymptomatic population screening for colorectal (bowel) cancer. FIT are also used to assist with the assessment of patients presenting with lower abdominal symptoms. Quantitative FIT allow the generation of numerical estimates of faecal haemoglobin (f-Hb) concentrations. There is now great interest in "low" f-Hb concentrations in these clinical settings: in consequence, knowledge of the detection capability is very important for f-Hb concentration examinations. There are a number of current problems associated with the reporting of low f-Hb concentrations and wide misunderstanding of the metrological aspects of examinations of f-Hb at low concentrations. These would be solved if the detectability characteristics of f-Hb concentration examinations, namely, the limit of blank (LoB), limit of detection (LoD) and limit of quantitation (LoQ), were generated, validated and used in reporting systems exactly as recommended in the EP17-A2 guideline of the Clinical Laboratory Standards Institute. LoB and LoD are statistical concepts, but the LoQ depends on definition of analytical performance specifications (APS). In this Opinion Paper proposals for interim APS are made, based on the current state of the art achieved with examinations of faecal samples. It is proposed that LoQ is determined at an examination imprecision of CV≤10% using faecal samples naturally positive for Hb rather than faeces spiked with haemolysate. Detailed proposals for reporting f-Hb data at low concentrations are also made.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Hemoglobinas / Imunoquímica / Fezes Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Hemoglobinas / Imunoquímica / Fezes Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2019 Tipo de documento: Article