Convergence insufficiency in Chinese high school students.
Clin Exp Optom
; 102(2): 166-171, 2019 03.
Article
em En
| MEDLINE
| ID: mdl-30206993
ABSTRACT
BACKGROUND:
The frequency of convergence insufficiency was determined in a sample of Chinese high school students. The associations between the frequency of convergence insufficiency, gender, refractive error and accommodative insufficiency were investigated.METHODS:
This was a single-site, prospective cross-sectional study. In total, 928 eligible teenagers (mean age 15.9 ± 0.8) from a local high school in Guangzhou, Guangdong Province, China participated in this study. Refraction and binocular vision tests were performed on all eligible participants. The following three signs were used to classifyparticipants:
sign 1, exophoria at near at least 4âµ greater than at far; sign 2, receded near point of convergence (≥ 6 cm break point); and sign 3, insufficient near positive fusional vergence (that is, failing Sheard's criterion or ≤ 15âµ break point). Diagnostic groups of convergence insufficiency classification were defined as follows (1) 3-Sign convergence insufficiency (all three signs present); (2) 2-Sign convergence insufficiency (sign 1 plus sign 2 or 3); (3) 1-Sign convergence insufficiency (sign 1 only); and (4) no convergence insufficiency (that is, participants not classified into one of the above groups).RESULTS:
The number and frequency of individuals with 3-Sign, 2-Sign, and 1-Sign convergence insufficiency as well as no convergence insufficiency group were 25 (2.7 per cent), 119 (12.8 per cent), 303 (32.6 per cent) and 481 (51.8 per cent), respectively. Gender (χ2 = 36.6, df = 3, p < 0.001), refractive error grouping (χ2 = 37.7, df = 9, p < 0.001) and accommodative insufficiency (χ2 = 15.4, df = 3, p = 0.002) were all significantly associated with convergence insufficiency. Male gender, hyperopia, or accommodative insufficiency were more likely to be classified with 3-Sign convergence insufficiency. The frequency of accommodative insufficiency was 9.5 per cent (88 of 928 participants).CONCLUSION:
Compared to the data from school- and clinic-based populations in the USA and South Africa, the data from this sample of Chinese high school students showed a lower frequency of 3-Sign convergence insufficiency (2.7 per cent). Convergence insufficiency was associated with refractive error, gender and accommodative insufficiency.Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Instituições Acadêmicas
/
Estudantes
/
Visão Binocular
/
Transtornos da Motilidade Ocular
/
Convergência Ocular
/
Acomodação Ocular
Tipo de estudo:
Incidence_studies
/
Observational_studies
/
Prevalence_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Adolescent
/
Female
/
Humans
/
Male
País/Região como assunto:
Asia
Idioma:
En
Revista:
Clin Exp Optom
Assunto da revista:
OPTOMETRIA
Ano de publicação:
2019
Tipo de documento:
Article
País de afiliação:
China