Your browser doesn't support javascript.
loading
Optimal repetition time reduction for single subject event-related functional magnetic resonance imaging.
McDowell, Amy R; Carmichael, David W.
Afiliação
  • McDowell AR; UCL GOS Institute of Child Health, London, UK.
  • Carmichael DW; UCL GOS Institute of Child Health, London, UK.
Magn Reson Med ; 81(3): 1890-1897, 2019 03.
Article em En | MEDLINE | ID: mdl-30230635
ABSTRACT

PURPOSE:

Short TRs are increasingly used for fMRI as fast sequences such as simultaneous multislice excitation become available. These have been associated with apparent sensitivity improvements, although greater temporal autocorrelation at shorter TRs can inflate sensitivity measurements leading to uncertainty regarding the optimal approach.

METHODS:

In volunteers (n = 10), the optimal TR was assessed at the single subject level for event-related designs (visual stimulation) with 4 frequencies of presentation at 4 TR values (412-2550 ms). T-values in the visual cortex localized in each individual were obtained and receiver operating characteristics (ROC) analysis was performed by counting voxels within and outside expected task active regions at different thresholds. This analysis was repeated using 4 different autoregressive (AR) models; SPM AR(1) and SPM AR(fast) which globally estimate autocorrelation, and fMRIstat AR(1) and AR(5) that use a local estimate.

RESULTS:

The use of modest multiband factors of 2 or 3 with a reduction in TR to 1000 ± 200 ms had greater sensitivity and specificity as shown by higher T-values in visual cortex and ROC analysis. At these TRs, the ROC analysis demonstrated that a local AR model fit improved performance while high order AR models were unnecessary.

CONCLUSIONS:

Modest TR reductions (to 1000 ± 200 ms) optimally improved event-related fMRI performance independent of design frequency. Autoregressive models with a local as opposed to global fit performed better, while low order autoregressive models were sufficient at the optimal TR.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Córtex Visual / Processamento de Imagem Assistida por Computador / Mapeamento Encefálico / Imageamento por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Córtex Visual / Processamento de Imagem Assistida por Computador / Mapeamento Encefálico / Imageamento por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Reino Unido