Your browser doesn't support javascript.
loading
Initial experiences with a novel biodegradable device for percutaneous closure of atrial septal defects: From preclinical study to first-in-human experience.
Li, Yi-Fan; Xie, Yu-Mei; Chen, Jun; Li, Bo-Ning; Xie, Zhao-Feng; Wang, Shu-Shui; Zhang, Zhi-Wei.
Afiliação
  • Li YF; Department of Pediatric Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangzhou, China.
  • Xie YM; Department of Pediatric Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangzhou, China.
  • Chen J; Department of Pediatric Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangzhou, China.
  • Li BN; The Second School of Clinical Medicine, Southern Medical University, Guangzhou, China.
  • Xie ZF; Department of Pediatric Cardiology, Shenzhen Children's Hospital, Shenzhen, China.
  • Wang SS; Department of Pediatric Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangzhou, China.
  • Zhang ZW; Department of Pediatric Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangzhou, China.
Catheter Cardiovasc Interv ; 95(2): 282-293, 2020 02.
Article em En | MEDLINE | ID: mdl-31714687
OBJECTIVE: To evaluate the feasibility, safety, and effectiveness of a novel, absorbable atrial septal defect (ASD) closure device made of poly-l-lactic acid (PLLA) in a swine model of ASD and for the first time in humans. METHODS: A preclinical safety study was conducted using a swine model of ASD. In a clinical setting, five pediatric patients underwent ASD closure with the PLLA device with fluoroscopic and transthoracic echocardiography guidance. The procedural results and clinical outcomes at 1 day, 30 days, 3 months, and 6 months after closure were analyzed. RESULTS: The 24- and 36-month follow-up results of the preclinical study demonstrated that the PLLA device exhibited good endothelialization and degradability in the swine model. In the clinical study, successful device implantation was achieved in all five patients (median age, 3.6 years; range, 3.1-6.5 years). The mean defect size was (13.6 ± 2.7) mm. Follow-up at 30 days, 3 months, and 6 months was completed in all five cases. The complete defect closure rates with no residual shunt at 30 days, 3 months, and 6 months follow-up were 60% (3/5), 80% (4/5), and 80% (4/5), respectively. No device dislodgement, significant aortic valve or mitral valve regurgitation, new onset cardiac arrhythmia, or other adverse events were reported. CONCLUSION: The study results demonstrated that it is feasible to implant the PLLA device for closure of small to medium sized ASDs without significant residual shunts or severe adverse events in humans. The PLLA device exhibited good endothelialization and degradability in the swine model at 24 and 36 months. Further studies to evaluate long-term safety and effectiveness with the device in a large cohort of patients are warranted.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poliésteres / Cateterismo Cardíaco / Implantes Absorvíveis / Comunicação Interatrial Tipo de estudo: Guideline / Prognostic_studies Limite: Animals / Child / Child, preschool / Female / Humans / Male Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poliésteres / Cateterismo Cardíaco / Implantes Absorvíveis / Comunicação Interatrial Tipo de estudo: Guideline / Prognostic_studies Limite: Animals / Child / Child, preschool / Female / Humans / Male Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China