Paclitaxel-coated peripheral artery devices are not associated with increased mortality.
J Vasc Surg
; 72(3): 968-976, 2020 09.
Article
em En
| MEDLINE
| ID: mdl-31917036
ABSTRACT
OBJECTIVE:
Long-term safety concerns have been raised that the use of paclitaxel-coated balloons and stents is linked to excess mortality. Our objective was to compare outcomes in patients treated with paclitaxel vs uncoated devices and to analyze long-term mortality.METHODS:
We conducted a retrospective single-institution review of 1170 consecutive patients who underwent femoropopliteal percutaneous revascularization by angioplasty, atherectomy, stent placement, or combination between 2011 and 2018. The primary outcome measure was all-cause mortality. Groups were divided into patients who received paclitaxel (n = 652) and those who did not (n = 518). Categorical variables were assessed using χ2 analysis and continuous variables with the Wilcoxon signed rank test. A multivariable analysis was performed using multivariable logistic regression models. Mortality was compared using Kaplan-Meier survival analysis.RESULTS:
Demographics, risk factors, and Rutherford class were similar between the groups, except that the paclitaxel group was more likely to have diabetes (60.9% vs 55.0%; P = .04), was less likely to be on dialysis (10.7% vs 14.9%; P = .04), and had lower average creatinine concentration (1.6 ± 1.8 mg/dL vs 2.0 ± 2.3 mg/dL; P = .003). There were no differences in all-cause mortality through 2 years between paclitaxel and no-paclitaxel cohorts (25.5% vs 30.3%; log-rank, P = .098). At 3 years and 3.5 years, mortality was significantly lower in the paclitaxel group year 3, 32.1% vs 39.4% (log-rank, P = .041); year 3.5, 35.2% vs 43.9% (log-rank, P = .027). Survival rates were not significantly different in examining subgroups by diabetes, chronic kidney disease, presence of chronic limb-threatening ischemia, or paclitaxel-coated balloon manufacturer. Multivariable analysis demonstrated that age, dialysis, chronic limb-threatening ischemia, chronic kidney disease, and congestive heart failure were independent risk factors for mortality, whereas paclitaxel use was associated with lower mortality.CONCLUSIONS:
The use of paclitaxel-coated balloons and stents does not increase mortality compared with uncoated devices out to 3.5 years. Paclitaxel-coated devices can be used with continued caution, especially in patients at increased risk of restenosis. Further long-term studies are needed to determine the risk of late mortality.Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Artéria Poplítea
/
Fármacos Cardiovasculares
/
Paclitaxel
/
Angioplastia com Balão
/
Materiais Revestidos Biocompatíveis
/
Stents Farmacológicos
/
Artéria Femoral
/
Doença Arterial Periférica
Tipo de estudo:
Etiology_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
J Vasc Surg
Assunto da revista:
ANGIOLOGIA
Ano de publicação:
2020
Tipo de documento:
Article