Your browser doesn't support javascript.
loading
Profiling microRNAs in uncomplicated pregnancies: Serum vs. plasma.
Parker, Victoria L; Gavriil, Eleftherios; Marshall, Benjamin; Pacey, Allan; Heath, Paul R.
Afiliação
  • Parker VL; Department of Oncology and Metabolism, The University of Sheffield, Sheffield S10 2SF, United Kingdom.
  • Gavriil E; Department of Oncology and Metabolism, The University of Sheffield, Sheffield S10 2SF, United Kingdom.
  • Marshall B; Department of Oncology and Metabolism, The University of Sheffield, Sheffield S10 2SF, United Kingdom.
  • Pacey A; Department of Oncology and Metabolism, The University of Sheffield, Sheffield S10 2SF, United Kingdom.
  • Heath PR; Sheffield Institute of Translational Neuroscience, The University of Sheffield, Sheffield S10 2HQ, United Kingdom.
Biomed Rep ; 14(2): 24, 2021 Feb.
Article em En | MEDLINE | ID: mdl-33408858
Blood-derived microRNAs (miRNAs/miRs) are ideal clinical biomarkers, as they can be relatively non-invasively extracted and are stable across a range of storage conditions. However, the concentration and profile of miRNAs differ between specific patient groups and starting media, which must be a key consideration before embarking upon uses for clinical applications. The optimum blood-derived starting media for biomarker discovery involving pregnant women with an uncomplicated pregnancy has not been determined. Paired serum and plasma samples were collected from 10 pregnant women with uncomplicated low-risk pregnancies at three time points: i) During the second trimester of pregnancy; ii) during the third trimester; and iii) 6 weeks post-partum. Sample miRNA content was assessed using an Agilent Bioanalyzer Small RNA chip and reverse transcription-quantitative (RT-q)PCR using four constitutively expressed miRNAs: hsa-miR-222-3p, hsa-miR-23a, hsa-miR-30e-5p and hsa-miR-451a. Quality control spike-ins measured RNA extraction (UniSp2) and cDNA extraction (cel-miR-39-3p) efficiency. MiRNA concentration and percentage were significantly higher in the serum vs. plasma samples based on data obtained from the Bioanalyzer; however, RT-qPCR failed to replicate these differences in the majority of comparisons using the ΔCq values of the four constitutively expressed miRNAs. Using the standard deviations of the ΔCq values, the consistency of serum and plasma in terms of miRNA expression levels were equivalent. Thus, clinicians and researchers should take into consideration that different miRNA quantification methods can yield contrasting results with regards to the starting media utilized. Based on the equivalent performance of serum and plasma assessed using RT-qPCR, which is less likely to be influenced by the coagulation process or degraded long RNAs, both starting media assessed in the present study are equally suitable for ongoing biomarker discovery studies involving healthy pregnant women at any gestational time point or immediately postpartum.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Biomed Rep Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Biomed Rep Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Reino Unido