Small balloon strategy associated with low pacemaker implantation rate after self-expanding transcatheter valve implantation.
Zhang, Yuan; Pan, Wen-Zhi; Guan, Li-Hua; Zhang, Xiao-Chun; Chen, Sha-Sha; Yang, Li-Fan; Zhang, Lei; Li, Ming-Fei; Chen, Dan-Dan; Zhou, Da-Xin; Ge, Jun-Bo.
Afiliação
  • Zhang Y; Department of Cardiology, Shanghai Institute of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Pan WZ; Department of Cardiology, Shanghai Institute of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Guan LH; Department of Cardiology, Shanghai Institute of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Zhang XC; Department of Cardiology, Shanghai Institute of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Chen SS; Department of Cardiology, Shanghai Institute of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Yang LF; Department of Cardiology, Shanghai Institute of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Zhang L; Department of Cardiology, Shanghai Institute of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Li MF; Department of Cardiology, Shanghai Institute of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Chen DD; Department of Cardiology, Shanghai Institute of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Zhou DX; Department of Cardiology, Shanghai Institute of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
  • Ge JB; Department of Cardiology, Shanghai Institute of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
World J Emerg Med ; 12(1): 48-53, 2021.
Article em En | MEDLINE | ID: mdl-33505550
ABSTRACT

BACKGROUND:

This study aims to investigate whether small balloon aortic valvuloplasty (BAV) reduces the need for permanent pacemaker implantation (PPMI) after transcatheter aortic valve implantation (TAVI).

METHODS:

This was a retrospective analysis using data from our local TAVI database. Small BAV was defined as a small balloon size (=18 mm) pre-dilatation. Normal BAV was defined as a balloon size >18 mm. The primary endpoint was the incidence of new PPMI.

RESULTS:

Of 99 consecutive TAVI patients, five patients were excluded due to pre-existing permanent pacemaker. Patients in the small BAV group (n=57) had a significantly lower PPMI rate compared with the normal BAV group (n=37) (3.5% vs. 18.9%, P=0.026). Moderate or severe aortic valve regurgitation post-procedure was similar between the small BAV and normal BAV groups (5.3% vs. 8.1%, P=0.480); likewise, the mean aortic gradient post-procedure did not differ significantly (11.5±5.2 mmHg vs. 12.2±7.3 mmHg, 1 mmHg=0.133 kPa, P=0.580) between the groups. Device success rates were also similar (94.7% vs. 91.8%, P=0.680). In multivariable analysis, small BAV (P=0.027), the ratio of prosthesis diameter to annulus diameter (P=0.048), and mean aortic gradient by echo in the basement (P=0.021) were independent predictors of PPMI.

CONCLUSIONS:

The small BAV strategy is associated with a low rate of permanent pacemaker implantation after transcatheter self-expanding valve implantation in this single-center observational study.