Your browser doesn't support javascript.
loading
Comparison and optimisation of microRNA extraction from the plasma of healthy pregnant women.
Parker, Victoria L; Cushen, Bryony F; Gavriil, Eleftherios; Marshall, Benjamin; Waite, Sarah; Pacey, Allan; Heath, Paul R.
Afiliação
  • Parker VL; Department of Oncology and Metabolism, The University of Sheffield, Sheffield S10 2SF, UK.
  • Cushen BF; Department of Oncology and Metabolism, The University of Sheffield, Sheffield S10 2SF, UK.
  • Gavriil E; Department of Oncology and Metabolism, The University of Sheffield, Sheffield S10 2SF, UK.
  • Marshall B; Department of Oncology and Metabolism, The University of Sheffield, Sheffield S10 2SF, UK.
  • Waite S; Department of Oncology and Metabolism, The University of Sheffield, Sheffield S10 2SF, UK.
  • Pacey A; Department of Oncology and Metabolism, The University of Sheffield, Sheffield S10 2SF, UK.
  • Heath PR; Sheffield Institute of Translational Neuroscience, The University of Sheffield, Sheffield S10 2HQ, UK.
Mol Med Rep ; 23(4): 1, 2021 04.
Article em En | MEDLINE | ID: mdl-33576446
Circulating microRNA (miRNA) biomarkers are implicated in the diagnosis, monitoring and prediction of various disease processes. Before embarking upon biomarker discovery, miRNA extraction techniques must first be optimised in the biofluid and population under study. Using plasma from a healthy pregnant woman, it was attempted to optimise and compare the performance of two commercially available miRNA extraction kits; Qiagen (miRNeasy Serum/Plasma) and Promega (Maxwell® RSC miRNA from Tissue or Plasma or Serum). Sample miRNA content (concentration and percentage) was assessed using Agilent Bioanalyzer Small RNA chips and reverse transcription­quantitative PCR (RT­qPCR) using four constitutively expressed miRNAs (hsa­miR­222­3p, hsa­let­7i­3p, hsa­miR­148­3p and hsa­miR­30e­5p). Quality control spike­ins monitored RNA extraction (UniSp2, 4 and 5) and cDNA synthesis (UniSp6, cel­miR­39­3p) efficiency. Optimisation approaches included: i) Starting volume of plasma; the addition of ii) Proteinase K; iii) a RNA bacteriophage carrier (MS2); and iv) a glycogen carrier. The two kits exhibited equivalence in terms of miRNA recovery based on Bioanalyzer and RT­qPCR ΔΔCq results. Optimisation attempts for both kits failed to improve upon miRNA content compared with standard methodology. Comparing the standard methodology, the Qiagen kit was more consistent (smaller variance of ΔCq values) compared with the Promega kit. The standard methodology of either kit would be suitable for the investigation of miRNA biomarkers in a healthy pregnant population.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Kit de Reagentes para Diagnóstico / Biomarcadores / MicroRNAs / MicroRNA Circulante Tipo de estudo: Prognostic_studies Limite: Female / Humans / Pregnancy Idioma: En Revista: Mol Med Rep Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Kit de Reagentes para Diagnóstico / Biomarcadores / MicroRNAs / MicroRNA Circulante Tipo de estudo: Prognostic_studies Limite: Female / Humans / Pregnancy Idioma: En Revista: Mol Med Rep Ano de publicação: 2021 Tipo de documento: Article