Safe procedures despite ultra low radiation doses during catheter ablations of atrial and ventricular arrhythmias-A multicenter experience.
Attanasio, Philipp; Huemer, Martin; Kaehler, Nora; Keller, Theresa; Schreiber, Tobias; Niehues, Reinhard; Katsani-Potempa, Dimitra; Klein, Rolf Michael; Landmesser, Ulf; Deisenhofer, Isabel; Tutdibi, Osman; Bourier, Felix.
Afiliação
  • Attanasio P; Department of Cardiology, Charité-Universitätsmedizin Berlin, Campus Benjamin Franklin, Berlin, Germany.
  • Huemer M; DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.
  • Kaehler N; Department of Cardiology, Charité-Universitätsmedizin Berlin, Campus Benjamin Franklin, Berlin, Germany.
  • Keller T; DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.
  • Schreiber T; Department of Cardiology, Charité-Universitätsmedizin Berlin, Campus Benjamin Franklin, Berlin, Germany.
  • Niehues R; DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.
  • Katsani-Potempa D; Institute for Biometry and Clinical Epidemiology, Charité - Universitätsmedizin Berlin, Berlin, Germany.
  • Klein RM; Department of Cardiology, Charité-Universitätsmedizin Berlin, Campus Benjamin Franklin, Berlin, Germany.
  • Landmesser U; DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.
  • Deisenhofer I; Augusta Krankenhaus Düsseldorf, Department of Cardiology, Academic Teaching Hospital of the University Faculty of Health, Düsseldorf, Germany.
  • Tutdibi O; Augusta Krankenhaus Düsseldorf, Department of Cardiology, Academic Teaching Hospital of the University Faculty of Health, Düsseldorf, Germany.
  • Bourier F; Augusta Krankenhaus Düsseldorf, Department of Cardiology, Academic Teaching Hospital of the University Faculty of Health, Düsseldorf, Germany.
Pacing Clin Electrophysiol ; 44(5): 807-813, 2021 May.
Article em En | MEDLINE | ID: mdl-33665850
ABSTRACT

INTRODUCTION:

Despite the development of non-fluoroscopic catheter visualization options, fluoroscopy is still used in most ablation procedures. The aim of this multicenter study was to evaluate the safety and efficacy of a new ultra-low dose radiation protocol for EP procedures in a large number of patients. METHODS AND

RESULTS:

A total of 3462 consecutive patients (male 1926 (55.6%), age 64.4 ± 14.0 years, BMI 26.65 ± 4.70) undergoing radiofrequency ablation (left atrial (n = 2316 [66.9%], right atrial (n = 675 [19.5%], or ventricular (n = 471 [13.6%]) in three German centers were included in the analysis. Procedures were performed using a new ultra-low dose protocol operating at 8nGy for fluoroscopy and 36nGy for cine-loops. Additionally a very low framerate (2-3FPS) was used. Using the new protocol very low Air kerma-area product (KAP) values were achieved for left atrial ablations (104.25 ± 84.22 µGym2 ), right atrial ablations (70.98 ± 94.79 µGym2 ) and ablations for ventricular tachycardias or PVCs (78.62 ± 66.59 µGym2 ). Acute procedural success was achieved in 3289/3388 (97.1%) while the rate of major complications was very low compared to previously published studies not using low dose settings (n = 20, 0.6%).

CONCLUSION:

The ultra-low dose, low framerate protocol leads to very low radiation doses for all EP procedures while neither procedural time, fluoroscopy time nor success or complication rates were compromised. When compared to current real-world Air KAP data the new ultra-low dose fluoroscopy protocol reduces radiation exposure by more than 90%.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Proteção Radiológica / Fluoroscopia / Radiografia Intervencionista / Ablação por Cateter Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Proteção Radiológica / Fluoroscopia / Radiografia Intervencionista / Ablação por Cateter Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha