Your browser doesn't support javascript.
loading
Reliability of the Squat Jump Force-Velocity and Load-Velocity Profiles.
Kotani, Yosuke; Lake, Jason; Guppy, Stuart N; Poon, Wayne; Nosaka, Kazunori; Hori, Naruhiro; Haff, G Gregory.
Afiliação
  • Kotani Y; School of Medical and Health Sciences, Edith Cowan University, Joondalup, Australia.
  • Lake J; School of Medical and Health Sciences, Edith Cowan University, Joondalup, Australia.
  • Guppy SN; Department of Sport and Exercise Sciences, University of Chichester, Chichester, United Kingdom.
  • Poon W; School of Medical and Health Sciences, Edith Cowan University, Joondalup, Australia.
  • Nosaka K; School of Medical and Health Sciences, Edith Cowan University, Joondalup, Australia.
  • Hori N; School of Medical and Health Sciences, Edith Cowan University, Joondalup, Australia.
  • Haff GG; Performance Enhancement Division, Western Australian Institute of Sport, Perth, Australia ; and.
J Strength Cond Res ; 36(11): 3000-3007, 2022 Nov 01.
Article em En | MEDLINE | ID: mdl-33966009
ABSTRACT: Kotani, Y, Lake, J, Guppy, SN, Poon, W, Nosaka, K, Hori, N, and Haff, GG. The reliability of the squat jump force-velocity and load-velocity profiles. J Strength Cond Res 36(11): 3000-3007, 2022-The purpose of this study was to investigate the between-session reliability of the squat jump force-velocity (FV) and load-velocity (LV) profiles. Eighteen subjects (age = 28.1 ± 4.8 years; height = 1.7 ± 9.7; body mass = 74.7 ± 12.8) who could back squat >1.5 times body mass participated in this study. Each subject completed a familiarization session, followed by 2 experimental sessions each separated by 72 hours. Subjects performed a series of squat jumps on a force plate against external loads between 0 and 100% of their body mass in a quasi-randomized block order. Intraclass correlation coefficient (ICC) and coefficient of variation (CV) were used to examine the between-session reliability. Peak velocity (PV) and mean velocity (MV) at each load were highly reliable (ICC >0.80, CV% <7.41, SEM <0.13 m·s -1 , smallest detectable difference [SDD] <0.31 m·s -1 , ES <0.21). Force-velocity profiles created with peak force and relative peak force resulted in poor to excellent reliability (ICC = 0.34-0.92, CV% = 11.9-26.3). When mean and relative mean forces were used to create FV profiles, there was poor to good reliability (ICC = 0.03-0.85, CV% = 18.1-39.4). When the LV profile was calculated with PV (ICC = 0.60-0.90, CV% = 7.9-16.9) or MV (ICC = 0.49-0.91, CV% = 11.1-23.4), there was poor to excellent reliability. There was no time effect found between sessions for both FV and LV profiles. The squat jump FV and LV profiles established with a force plate are not reliable. Therefore, these profiles are not recommended to be used to inform programming decisions.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Postura / Teste de Esforço Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Adult / Humans Idioma: En Revista: J Strength Cond Res Assunto da revista: FISIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Postura / Teste de Esforço Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Adult / Humans Idioma: En Revista: J Strength Cond Res Assunto da revista: FISIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Austrália