Your browser doesn't support javascript.
loading
On the Use of Pulsed UV or Visible Light Activated Gas Sensing of Reducing and Oxidising Species with WO3 and WS2 Nanomaterials.
González, Ernesto; Casanova-Chafer, Juan; Alagh, Aanchal; Romero, Alfonso; Vilanova, Xavier; Acosta, Selene; Cossement, Damien; Bittencourt, Carla; Llobet, Eduard.
Afiliação
  • González E; Electronic Engineering, Uiversitat Rovira i Virgili, 43007 Tarragona, Spain.
  • Casanova-Chafer J; Electronic Engineering, Uiversitat Rovira i Virgili, 43007 Tarragona, Spain.
  • Alagh A; Electronic Engineering, Uiversitat Rovira i Virgili, 43007 Tarragona, Spain.
  • Romero A; Electronic Engineering, Uiversitat Rovira i Virgili, 43007 Tarragona, Spain.
  • Vilanova X; Electronic Engineering, Uiversitat Rovira i Virgili, 43007 Tarragona, Spain.
  • Acosta S; Chimie des Interactions Plasma e Surface (ChIPS), Research Institute for Materials Science and Engineering, Université de Mons, 7000 Mons, Belgium.
  • Cossement D; Materia Nova, Parc Initialis, 7000 Mons, Belgium.
  • Bittencourt C; Chimie des Interactions Plasma e Surface (ChIPS), Research Institute for Materials Science and Engineering, Université de Mons, 7000 Mons, Belgium.
  • Llobet E; Electronic Engineering, Uiversitat Rovira i Virgili, 43007 Tarragona, Spain.
Sensors (Basel) ; 21(11)2021 May 27.
Article em En | MEDLINE | ID: mdl-34072115
This paper presents a methodology to quantify oxidizing and reducing gases using n-type and p-type chemiresistive sensors, respectively. Low temperature sensor heating with pulsed UV or visible light modulation is used together with the application of the fast Fourier transform (FFT) to extract sensor response features. These features are further processed via principal component analysis (PCA) and principal component regression (PCR) for achieving gas discrimination and building concentration prediction models with R2 values up to 98% and RMSE values as low as 5% for the total gas concentration range studied. UV and visible light were used to study the influence of the light wavelength in the prediction model performance. We demonstrate that n-type and p-type sensors need to be used together for achieving good quantification of oxidizing and reducing species, respectively, since the semiconductor type defines the prediction model's effectiveness towards an oxidizing or reducing gas. The presented method reduces considerably the total time needed to quantify the gas concentration compared with the results obtained in a previous work. The use of visible light LEDs for performing pulsed light modulation enhances system performance and considerably reduces cost in comparison to previously reported UV light-based approaches.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Espanha